2 3
Digital Door Lock COMMAX
Major Features
Robust & Reliable Product with Korean Quality Certificates
Strict quality & manufacturing system with KS (=Korea Industrial Standard) certificates.
Auto-lock/Reverse-lock/Dual-lock
To provide users with the best convenience and safety.
Password safety with imaginary and security functions
The imaginary and the security function can be used safely when entering the password.
Multi Step Volume Control / Optional Silence Mode
Total 7 different sound volume mode can be selectable.
Button plate with lights for dark plate use.
Once touch the button plate, each buttons light on and make easier to use in the dark.
Emergency Power Supply (9V Alkaline quadrangle battery 1ea)
If batteries are fully discharged, 9V battery can be used for supplying emergency power.
Anti-excessive voltage / fire / hacking system
It’s safe equipped with anti-excessive voltage/hacking system. It also has fire-detection
sensors checking the indoor temperature. If temperature is out of normal and fire might
be occurred, doorlock is automatically unlocked.
Multiple Registration of passwords / smart keys
Different passwords (max. 4ea) or smart keys (max. 30ea) can be registered.
Highly Durable Metal Body
Designed with metal body for highest durability against fire or physical impact from outside.
Safety Caution
Do not install,
disassemble, repair
products at random.
Do not push buttons with
sharp material like pin or
awl etc.
If battery is inserted
adversely, liquid leak or
battery disruption might
be occurred.
(LR6 AA)
When cleaning, use
dried superfine fibers
towel.
This product is
applicable for residential
fire-door only.
Read user guide
carefully before use.
Regular update or
change password is
recommended for safety.
Do not impact product
with excessive force.
Make sure no water
enters into inside of
product.
All 4 new batteries have
to be replaced at once.
Keep product warrantee
card for after sales
service.
Do not use other
purposes besides digital
door lock usage.
Component
Content Specification
4 5
01
Specification
02
Part Name
03
How to Use
Sound Pause
Sound Adjustment
Auto/Manual Lock Setting
Smart key Auto/Manual setting
Multi-touch security setting
08
09
10
10
11
12
12
13
04
Convenient Function
(option)
14
14
15
15
16
05
Emergency Alam
17
17
18
18
19
06
Cause and Solution
20
05
06
01
Register/Change Password
Register/Change Smart Key
How to delete Smart Key
Open door from outside
Close door from outside
Open door from inside
Close door from inside
Compulsive Lock
High Temperature Detection
Intrusion Alam
Wrong input prevention
Mortise trapping Alert
Battery Replacement Alarm
Digital Door Lock COMMAX
Product Specification
Category
Installed at Common Fire Door
Password
Smart Key
Door Open by
Power Source DC 6V
Emergency Power DC 9V
Product Category
Direct Current, Non fire-resistance type, Temperature Sensor,
Non physical-key type, Sub key door lock (D-NF-T-NK-S)
Temperature
Detection
Temperature
Sensor type
72°C ± 5°C (at Lab.)
62°C ± 5°C (at Site)
Materials
Al, Zn, ABS
Al, Zn, ABS
Spec.
RF Spec
Item
RFID
Frequency
13.56Mhz
Channels
1ea
Modulated by
ASK
Electric field strength
93.5dBuV/m@10m
Door Thickness 35mm ~ 50mm
4~12 digits (total 4 passwords registrable)
Less than 30 keys registrable.
LR6 1.5V AA size Alkaline battery (4ea)
Alkaline 9V battery (1ea)
Outdoor Body
Indoor Body
Outdoor Body Indoor Body Striker
Battery (4ea)
Screw
Warning Sticker Installation Guide
User Guide
(inclu. Product Warrantee)
Smart Key (4ea)
Function DescriptionName
Number Plate
Open the door by input the password.
Interface plate when register or change a new password.
Battery Alert
Touch Plate
Smart key interface plate. Unlock the door by touching
smart key. Interfacing plate for registration of new smart key.
Reset Switch If malfunction, product is reset by push this button.
Emergency
Power Outlet
If batteries are fully discharged, touch 9V battery onto this
outlet to supply emergency power.
Alarms-on with emergency sound when extremely low voltage.
6 7
Digital Door Lock COMMAX
Part name
02
Indoor Unit
Dead bolt
Auto door lock sensor
Locking bolt to close the door.
Detecting the status of door open and door close.
Manual Lock
Open/lock Button
AA battery
Password /
Smart key Button
Used to register or change a password or smart key.
Dual lock button
It is safe to lock the door so that you can not open the
door outside at nighttime.
Used to open or close doors manually.
Used to open or close the door indoors.
Power supply battery.
FunctionNameNo
Outdoor unit
9V Emergency Battery
(Prepared by user)
Battery Cover Damage prevention cover for battery, register button etc.
How to Use
03
Register / Change Password
Door MUST BE OPEN during this work.
8 9
Digital Door Lock COMMAX
Open battery cover of inside door body
first. Then the push button of “Register”
until beep sounds ringing.
After checking the light-on the mode of
number plate,
Input new password (4~12 digits of numbers).
Touch [ ] button on number plate,
registration is completed with beep sound.
If new password is not input until 10secs after pushing “Register” button,
Work is canceled. If new registration process is completed, previous
password is automatically deleted.
If additional passwords are registered, (up to 4 different passwords)
Repeat
&
before light-off of number plate.
Go to the outside of door
Stand at the outside of door
Stand at the outside of the door
Register / Change Smart Key
NOTE
CAUTION
CAUTION
When registering or re-registering a smart key,
you must register all the smart keys you have AT ONCE.
CAUTION
Open battery cover of inside door body
first. Then push button of “Register”
until beep sounds ringing.
After checking the light-on mode of
number plate,
Touch smart keys on touch plate one by one.
(Once key is touched & registered,
beep sounds ringing)
After all keys registered,
push [ ] button for completion.
Go to the outside of door
Stand at the outside of door
Stand at theoutside of the door
If smart key is not touched until 10 secs after pushing “Register” button,
work is canceled. If new registration process is completed, previous
smart key is automatically deactivated.
If additional smart keys are registered, (up to 30 keys)
Repeat
before light-off of number plate.
NOTE
CAUTION
10 11
Digital Door Lock COMMAX
How to Delete Smart key
How to Use
03
5 seconds
Open the door outdoors
Touch the plate and then,
enter password.
Open door with password
After touch [ ] button and you
hear sound, the door is open.
Close door
Way 1
Way 2
Way 2
Open door with imaginary function
After touching the license plate, press the imaginary number (any number), then press
the registered password and then press the [ ] button or the registered password,
press the imaginary number (any number) and press the [ ] button, you can open the
door.
When touch security function is set, when random password is input,
3 random number LED turns ON.
Touch the [ ] button to open the door.
If you purchased this product for the first time, the multi-touch
security feature is disabled (see page 16).
When you feel anxiety about password exposure,
you can use imaginary function.
Open door from the outside
Smart phones and transportation cards (T-Money, Cashbee) with a
transportation card function other than the provided smart key can be
opened by touching the outdoor.
Way 1
When setting auto detection
When you touch the registered [Smart Key],
you will open the door.
When setting manual
After touch the plate, and see the lamp.
You put the smart key on the plate and
then you will hear a confirmation tone and
open the door.
Open door with smart key
2 seconds
Open the inside of [Battery cover]
and push the [registration] button
to hear beep sound.
After check outside light on [Keypad],
When touch [ # ] button for 5sec,
registered smart key are deleted
with beep sound.
Go to the outside of door
Stand at the outside of door
NOTE
If you close door, door will be locked
Automatically. (Please refer to P. 15)
In case of setting auto lock function
If you touch [number plate]
door will be locked. (Please refer to P. 15)
In case of locking manually
NOTE
CAUTION
12 13
Digital Door Lock COMMAX
Open the door inside
Door will be locked again if door doesn’t
open within 7seconds.
How to Use
03
You can open the door by button.
Way 1
Open the door by button
Way 2
You can open the door by turning
[manual opening / closing device]
in the [Open] direction.
Open the door by manual
7 sec
Force lock function
External Dual Lock
This function stops the function of the [Open / Lock] button on the indoor side
Internal double lock
A feature that prevents the door from opening with a password or
smart key outside the door.
Set up
Removal
Activating the manual opening / closing device, password, or smart key opens the door
to disable the dual lock setting.
Removal
Opening the door by operating
the [INSTALLATION / OPEN /
LOCK] button on the indoor
side releases the double lock
setting.
Set up
With close the door
If you press the [DOUBLE LOCK] button
of the indoor body for 3 seconds, ‘confirmation
sound' appears and the setting is completed.
With the door
locked,
touch plate.
1
Touch the
registered
password.
2
[ # ] button,
then touch the
[0] button.
3
The [Open / Lock]
button on the indoor
side is disabled
with confirmation
sound.
4
Locking the door indoors
When the door lock is open, pressing
the [Open / Lock] button on the indoor
side locks the door lock.
Way 2
Lock door with button
When you close the door, the door
automatically locks in about 2 seconds.
Way 1
When Auto Lock is On
Way 3
With the door lock open, turning the
[manual opening / closing device] of the
indoor side body in the [lock] direction
locks the door lock.
Manually Locking the Door
2 seconds
CAUTION
14 15
Digital Door Lock COMMAX
Convenient Function (Option)
04
Outside touch plate , press [ # ] button. (without sound)
How to use
Sound pause function
This function is for One time mute to prevent beeping.
How to use
Volume control
This function is to control volume level. (In case door closes)
Because it is a one-time function,
an operation sound is generated at the next use.
On outside number plate, touch [3] button several time, volume
up. touch [6] button several time, volume down. When entering
Stop volume function, keypad Blink.
Press [3] or [6]
on outside
number plate.
4
After touching
outside number
plate
1
Enter [password]
2
press [ # ]button
3
There are 7 levels to control.
How to use password :
After touch password , press [ ] button and then the door
is open (Blinking the lamp)
Smart key use :
When you touch [Smart Key], the door opens
If you purchased the product for the first time, it is set to Auto-Lock.
When the manual lock is set, the door is not locked even when the door
is closed. Press the [Open / Lock] button or touch [Plate] of the outdoor
body to lock the door.
Automatic • Manual lock setting
This is an optional feature that locks doors automatically or manually.
With the door half open
Automatic•Manual lock
Press the [Open /
Lock] button on the
indoor side to release
the Mortis square lock
1
Touch the
outdoor plate.
2
After inputting
the password,
press the [ # ]
button twice.
3
[4] : Auto lock
[7] : anual Lock
Feature settings
4
Smart card automatic • Manual detection settings
This function sets the smart card to be detected automatically or manually.
If you touch the smart key contacts during automatic detection
setup, you can open the door.
When manual detection is set, you can open the door by touching
the license plate and touching the smart key contact.
Touch the outdoor
license plate.
1
Enter password.
2
press [ # ]button
3
[1] buttton:
Auto detection
[3] button:
manual detection
4
NOTE
NOTE
NOTE
NOTE
16 17
Digital Door Lock COMMAX
Convenient Function (Option)
04
Multi-Touch Security function
This is double security function by entering additional password.
It can delete finger print and divulge password.(In case door locks)
After touch plate outside number plate,
Enter password.
Touch [ # ] button.
Touch the button [5] on the license plate
to make a multi-touch security function with
a confirmation tone.
When multi-touch security function is set, repeat the items
①,②,③
and
to disable multi-touch security function.
Emergency Alarm
05
When multi-touch security function is set, when random password is
input, 3 random number LED turns ON. If you touch [ ] button you
can open the door. The imaginary function is turned off when the
multi-touch security function is set, and the imaginary function is turned
on when the multi-touch security function is turned off.
If the indoor body is exposed to direct sunlight for a long time, the
temperature sensor may be activated and a beep sound may be
generated. Internal double lock automatically unlocks the door.
Depending on the installation environment, there may be some
differences. If the room temperature falls below a certain temperature,
the door lock will operate normally.
High temperature detection
If a high enough temperature is detected
(62 ° C ± 5 ° C), a strong warning sound
will be generated and the lock will
automatically be released.
Remove the batteries, or touch [Password] or registered [Smart Key] to cancel.
How to release high temperature alarm and intrusion alarm
Release alarm
Intrusion alarm
If the door is unlocked abnormally (for example, by
opening a door) and a door open condition is detected,
a warning sound of 80 decibel (db) or more will be
generated.
If the temperature inside the room rises abnormally, the temperature sensor detects
it and sounds an alarm.
If you open the door forcibly from outside or inside it is a function that generates.
NOTE
NOTE
CAUTION
CAUTION
18 19
Digital Door Lock COMMAX
Emergency Alert
05
Deadbolt
“BEEP BEEP BEEP BEEP”
?
Prepare 9V
battery.
1
Put 9V battery
into emergency
power outlet.
2
Press [ ]
button.
3
Input
password.
4
Press [ ]
button again
then door is
open.
5
Wrong password prevention and 1 minute freeze function
Keep inputting unregistered password or smart key up to 5
times continuously, product freezes up with alert sound for
1 minute.
Temporary freezing function if wrong password or RF card keeps used from the outside.
5 times of unregistered input
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
Deadbolt malfunction alert
If keep sounding beeps or malfunctioning, the entire position of door lock
has to be adjusted. In this case, please call your local service agency or
installer. (Additional cost might be required.)
If deadbolt of indoor body is not clamped correctly during door open or close,
3 times of beep sound is ringing.
Battery replacement
- All batteries must be replaced with NEW ones all at once.
Do not mix up with used batteries.
- The lifetime of battery might be varied depending on manufacturers,
date of production, operating conditions etc.
- Do not mix up batteries from different manufacturers. If any liquid
leaks out of the body of batteries, it may hurt digital door locks.
Please regularly check it.
- Once battery replacement alarm rings, you can’t do password change
/ RF card registration / set configuration etc unless old batteries are
replaced.
When batteries inside are fully discharged.
Battery Replacement
How to use emergency battery
“BEEPBEEPBEEP”
If battery icon is activated with beep
sound after normal operation, you
must replace batteries with the ALL
NEW ones.
CAUTION
CAUTION
06
20 21
Digital Door Lock COMMAX
Cause and solution MEMO
If the product does not operate normally, check the following check point first.
If problem are still unsolved, please ask service center.
SolutionProblem
No Power
Page 8
Page
8, 11
Page
18, 19
Page 19
- Please check battery status bad or gone power
and check battery input direction.
- Please change new 4 alkaline Battery.
Cannot change
Password
- Please input password short “Beep”sound
one by one.
- Again password register / repeat input.
No open the door
though push
[ ]button
- Please check passwor input correctly
- When input password, keypad light off,
it will be not change password , presss the
[ ] button and check keypad light on,
input password again. (if didnot input password
within 7sec, it will be canceled.)
Password / Smart key
authentication success
but no open the door
- Please try 9V emergency power(square type)
- Lock can may broken. please contact service
center.
keep going alarm
“Beleek x3 ”
warning sound
- Beep indicating the battery replaced.
If you heard this alarm, please replace all new
4pcs battery.
Page
15, 19
Page 19
No enter
Auto Locking
- Please reset auto mode.
- Sound occurs the batteries discharge and does
not work. please change all new battery
ref.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Commax CDL-1AR Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI