LG HMNC126D4A0 Owner's manual

Category
Cookers
Type
Owner's manual

This manual is also suitable for

LG
MPS Multi Air Conditioner
INSTALLATION MANUAL
LG
website http://www.lgservice.com
e-mail http://www.lgeservice.com/techsup.html
IMPORTANT
Please read this instruction sheet completely before
installing the product.
When the power cord is damaged, replacement work shall
be performed by authorized personnel only.
Installation work must be performed in accordance with
the national wiring standards by authorized personnel
only.
ENGLISH
2 MPS Multi Air Conditioner
MPS Multi Air Conditioner Installation Manual
TABLE OF CONTENTS
Safety Precautions...............................3
Introduction...............................................5
Symbols used in this manual..........5
Features .....................................................5
Installation.................................................7
Installation parts....................................7
Installation tools ...................................7
Installation map....................................8
Selecting the best location ............9
Piping length and elevation.........11
Fixing installation plate ..................12
Drilling a hole in the wall ...............15
Flaring work .........................................17
Connecting the piping ..................18
Connecting the cables ..................26
Checking the drainage..................28
Forming the piping..........................30
Air purging............................................31
Test running .........................................33
Combination indoor units.............35
Combination table of Models....36
Four type "A" screws & plastic
anchors
Connecting cable
Installation guide map
Pipes: Gas side
Liquid side
Insulation materials
Additional drain pipe
(Outer diameter ..............15.5mm)
Two type "B" screws
Level gauge
Screw driver
Electric drill
Hole core drill(ø70mm)
Horizontal meter
Flaring tool set
Specied torque wrenches
1.8kg.m, 4.2kg.m, 5.5kg.m,
6.6kg.m
(dierent depending on model No.)
Spanner ........................Half union
A glass of water
Screw driver
Hexagonal wrench(4mm)
Gas-leak detector
Vacuum pump
Gauge manifold
Owner's manual
Thermometer
Remote control holder
Installation
Requirements
Required Parts Required Tools
Installation guide at the seaside...10
Ceiling opening dimensions
and hanging bolt location..............13
installation of decorative panel...23
Installation Manual 3
Safety Precautions
To prevent the injury of the user or other people and property damage, the following instructions
must be followed.
Be sure to read be
fore installing the air conditioner.
Be sure to obse
rve the cautions specified here as they include important items related to safety.
Incorrect ope
ration due to ignoring instruction will cause harm or damage. The seriousness is
classified
by the following indications.
The meanings of the symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Be sure not to do.
Be sure to
follow the instruction.
Safety Precautions
Do not disassemble or repair the product.
Contact your dealer or service center.
Always earth the product.
It will cause fire or electric shock.
Do not handle the flamable gas or explosive
materials near the
product.
Otherwise, it may cause fire or failure of
product.
Do not install where flama
ble gas could
leak.
Otherwise, it may cause esplosion or fire.
Do not install the product on an defected
installation stand.
Otherwise, It may cause injury or accident.
Be cautious when unpa
ck and install the
product.
Sharp edges could cause injury.
For electric work, contact the dealer or
se
rvice center.
Otherwise, It will cause fire or electric shock.
Do not use dam
aged power cable.
It will cause fire or electric shock.
For installation, always contact the dealer or
se
rvice center.
Otherwise, it may cause fire, electric shock,
explosion or injury."
Do not install the
product on an defected
installation stand.
Otherwise, It may cause injury or accident
HS
I
LGN
E
4 MPS Multi Air Conditioner
Safety Precautions
If strange sound, smell or smoke come from
product, turn the breaker off or disconnect
the power supply cable.
Otherwise, it may cause electric shock or re.
Do not put the heater, etc. near the power
cable.
Otherwise, it may cause re and electric shock.
Cover the electric part.
• Otherwise, it may cause re or electric shock.
Do not turn the breaker on/off or
connect/disconnect the power supply plug
during operation.
Otherwise, it may cause re or electric shock.
Do not open the suction inlet of the product
during operation.
• Otherwise, it may cause electric shock or
failure.
Do not touch the metal parts of the product
when removing the air filter.
Otherwise, it may cause personal injury.
Always inspect gas leakage after
installation and repair of product.
Otherwise, it may cause failure of product.
Install the drain hose to ensure that drain
can be securely done.
Otherwise, it may cause water leakage.
Keep the level even in installing the
product.
• Otherwise, it may cause vibration or water
leakage.
Do not install the product where the noise
or hot wind from the outdoor unit could
give any casualty to the neighborhood
• Otherwise, it may cause dispute with the
neighborhoods.
Do not step or put anyting on the product.
• Otherwise, it may cause personal injury and
failure of product.
Always intstall an circuit breaker and main
breaker.
• No installation may cause re and electric
shock.
Do not touch(operate) product with wet
hands.
• Otherwise, it may cause re or electric shock.
Installation Manual 5
Introduction
This symbol alerts you to the risk of electric shock.
This symbol ale
rts you to hazards that may cause harm to
the air conditione
r.
This symbol indicates special notes.
NOTICE
Introduction
Symbols used in this Manual
Features
INDOOR
HS
I
LGN
E
Model : S3,SZ
Model : S4,S5
Air Inlet
Air Filter
Front Panel
Signal Receptor
Model : S7
Front Panel
Air Filter
Triple Deodorizing Filter
Signal Receptor
Power Button
Air Filter
Air Inlet
Air Discharge
Signal receiver
Front panel
Air discharge
ON/OFF button
Air inlet
Air filter
Model : S8
MPS Multi Air Conditioner6
Introduction
Air Outlet
Air Intake
(side, rear)
Connection pipe
Drain hose
Connecting wire
Control cover
Air Intake Vents
Air Outlet Vents
Base Plate
Base Plate
Connection pipe
Drain hose
Connecting wire
Control cover
Outdoor
UE,UE1
UH
TC
Piping side
Decorative panel
fixing screws
(Hexagon M6 screw)
Air conditioner unit
Decorative panel
Cover display
Cover
Push
Control box cover
Decorative panel
fixing screws
(hexagon M6 screws)
Temporarily fitting
at 2 poles
(Tightening about 10mm)
Inlet GrilleInlet Grille
Louver motor
Inlet GrilleInlet GrilleInlet Grille
Key holes
7installation Manual
Installation
Type "A" screw and plastic anchor
Type "B" screw
Remote control holder
Installation plate
Figure FigureName
Screw driver
Electric drill
Measuring tape, Knife
Hole core drill
Spanner
Torque wrench
Ohmmeter
Hexagonal wrench
Ammeter
Gas-leak detector
Thermometer,
Horizontal meter
Flaring tool set
Name
Installation Parts
Installation Tools
S4,S5,S8
S7
SZ,S3
HS
I
LGN
E
MPS Multi Air conditioner8
Installation Map
Installation parts you should purchase.
Vertical Air deflector
Air Discarge
Forced Operation Button
Operation Indication Lamps/
Signal Receptor
Vinyl tape (Wide)
• Apply after carrying out a
drainage test.
• To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.
Saddle
Gas side piping (Optional Parts)
Liquid side piping (Optional Parts)
Additional drain pipe
Vinyl tape (Narrow)
Drain Hose
Base Plate
Connecting cable
(Optional Parts)
Installation plate
Sleeve
Bushing-Sleeve
Putty(Gum Type Sealer)
Bend the pipe as closely
on the wall as possible,
but be careful that it
doesn't break.
NOTICE
Air Outlet Vents
Air Inlet Vents
Installation Map
9Installation Manual
Installation
Indoor unit
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles
in front of the unit.
3. Make sure that condensation drainage can be
conveniently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and
the left (or right) of the unit is more than
50cm. The unit should be installed as high as
possible on the wall, allowing a minimum of
10cm from ceiling.
6. Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
Outdoor unit
1. If an awning is built over the unit to prevent
direct sunlight or rain exposure, make sure
that heat radiation from the condenser is not
restricted.
2. Ensure that the space around the back and
sides is more than 10cm. The front of the unit
should have more than 70cm of space.
3. Do not place animals and plants in the path
of the warm air.
4. Take the weight of the air conditioner into
account and select a place where noise and
vibration are minimum.
5. Select a place where the warm air and noise
from the air conditioner do not disturb
neighbors.
Rooftop Installations:
If the outdoor unit is installed on a roof
structure, be sure to level the unit. Ensure the
roof structure and anchoring method are
adequate for the unit location. Consult local
codes regarding rooftop mounting.
More than 10cm
More than
5cm
More than 2.3m
More than
5cm
Install the indoor unit on the wall where the height
from the floor is more than 2 meters.
more than
70cm
more than
30cm
more than
30cm
more than
20cm
more than
20cm
more than
70cm
Select the best Location
Unit:cm
Ceiling
Ceiling Board
Ceiling Board
20 or more
Above 250
330 or less
100
or more
50 or
more
50 or
more
30 or less
Floor
ENGLISH
Installation guide at the seaside
10 MPS Multi Air Conditioner
Installation
1.
Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are
produced.
2. Do not install the product where it could be exposed to sea wind (salty wind) directly. It can result
corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could
cause product malfunction or inefficient performance.
3.
If outdoor unit is installed close to the seaside, it should avoid direct exposure to the sea wind.
Otherwise it needs additional anticorrosion treatment on the heat exchanger.
1.
If you can’t meet above guide line in the seaside installation, please contact LG Electronics for the additional anticorrosion treatment.
2. Periodic ( more than once/year ) cleaning of the dust or salt particles stuck on the heat exchanger by using water
1) If the outdoor unit is to be installed close to the seaside, direct exposure to the sea wind should be avoided.
Install the outdoor unit on the opposite side of the sea wind direction.
2) In case, to install the outdoor unit on the seaside, set up a windbreak not to be exposed to the sea wind.
3) Select a well-drained place.
• It should be strong enough like concrete to prevent
the sea wind from the sea.
• The height and width should be more than 150% of
the outdoor unit.
• It should be keep more than 70 cm of space
between outdoor unit and the windbreak for easy
air flow.
Sea wind
Windbreak
1. Selecting the location(Outdoor Unit)
Installation Manual 11
HSI
LGN
E
Installation
Multi Piping Type
Piping length and elevation
Capacity(Btu/h)
Max total length
of all pipes
(A+B/A+B+C)
Max length of
each pipe
(A/B/C)
Min length of
each pipe
(A/B/C)
Max
Elevation
bet
ween each
indoor unit and
outdoor unit (h1)
Max el
evation
bet
ween indoor
units (h2)
h2
h2
h1
A
B
B
C
h2
h1
A
B
h1
h1
h1
CAUTION: Capacity is based on standard length and maximum allowance
length is on the basis of reliabilit
y.
9.52mm(3/8") 6.35mm(1/4") 7.5m(25ft) 20g/m
12K/18K 12.7mm(1/2") 6.35mm(1/4") 7.5m(25ft) 30g/m
Gas Liquid Standard Length
Additional
Ref
rigerant
Indoor Capacity
(Btu/h)
Pipe Si
ze
UE/UE1
UH
24K 15.88mm(5/8") 6.35mm(1/4") 7.5m(25ft) 30g/m
18K
45m(100ft)
15m(50ft) 7.5m(25ft) 7.5m(25ft)
3m(10ft)
36K
30m(100ft)
15m(50ft) 7.5m(25ft) 7.5m(25ft)
3m(10ft)
60m(100ft)
15m(50ft) 7.5m(25ft) 7.5m(25ft)
3m(10ft)
21K / 24K
48K
60m(100ft)
15m(50ft) 7.5m(25ft) 7.5m(25ft)
3m(10ft)
9K
12 MPS Multi Air Conditioner
Installation
The wall you select should be strong and solid
enough to pr
event vibration
1. Mount the installation plate on the wall with
type "A" scr
ews. If mounting the unit on a
concrete
wall, use anchor bolts.
Mount the installation plate ho
rizontally by
aligning the cente
rline using a level.
2. Measure the wall and mark the centerline. It
is also impo
rtant to use caution concerning
the location of the installation plate-routing
of the wi
ring to power outlets is through the
walls typically. Drilling the hole through the
wall for piping connections must be done
sa
fely.
Installation Plate
Type "A" screw
Chassis
Hook
A B C D
S4 50 105 59 105
CHASSIS
(G
rade)
Distance(mm)
Fixing Installation Plate
S3
S7
SZ
S4,S5,S8
S3,SZ
Right rear piping
Left rear pipi
ng
A
D
C
B
Ø70mm
Ø70mm
I
n
s
t
a
l
l
a
t
i
o
n
P
l
a
t
ee
t
a
l
P
n
o
i
t
a
l
l
a
t
s
n
I
58
S7
3
3
292
35
33
33
156
30
34
34110
For S3 Chassis, the center of the unit is
different from that of the Installation plate.
S5/S8
Installation plate
Left rear piping Right rear piping
Ø70mm
Ø70mm
D
B
A
C
95
122
122235
Installation
Installation Manual 13
ENGLISH
• Select and mark the position for fixing bolts
and piping hole.
• Decide the position for fixing bolts slightly tilted
to the drain direction after considering the
direction of drain hose.
Drill the hole for anchor bolt on the wall.
CAUTION:
This air-conditioner uses a drain pump.
• Horizontly install the unit using a level
gauge.
During the installation, care should be
taken not to damage electric wires.
Ceiling opening dimensions and hanging bolt location
The dimensions of the paper model for installing are the same as those of the ceiling opening dimensions.
Ceiling board
Level gauge
Ceiling
1,000 (Ceiling opening)
931.6
893.4 (Hanging bolt)
330 (Hanging bolt)
860
390
60
450 (Ceiling opening)
60
Unit:mm
744 Unit size
744 Unit size
658 (Hanging bolt)
6666
790 (Ceiling opening)
790 (Ceiling opening)
572(Hanging bolt)
109
109
Unit:mm
570 Unit size
570 Unit size
450 (Hanging bolt)
75
75
600 (Ceiling opening)
600 (Ceiling opening)
521(Hanging bolt)
39.5
39.5
Unit:mm
840 Unit size
840 Unit size
672 (Hanging bolt)
101.5101.5
875 (Ceiling opening)
875 (Ceiling opening)
785 (Hanging bolt)
45
45
Set screw of
paper model (4 pieces)
Paper model
for installation
Ceiling board
150mm
Adjust the same height
Ceiling board
Ceiling
Flat washer for M10
(accessory)
Keep the length of the bolt
from the bracket to 40mm
Open the ceiling board
along the outer edge of the
paper model
Flat washer for M10
(accessory)
Hanging bolt
(W3/8 or M10)
Nut
(W3/8 or M10)
Nut
(W3/8 or M10)
Spring washer
(M10)
Air Conditioner body
Installation
The Indoor Unit Installation
14 Multi-Type Air Conditioner
2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in
suspension in factories, etc.
3. Avoid places where inflammable gas is generated, flows in, is stored or vented.
4. Avoid places where sulfurous acid gas or corrosive gas is generated.
5. Avoid places near high frequency generators.
Thoroughly study the following installation locations:
1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere
to the turbo fan, the fin of the heat exchanger and the drain pump, resulting in heat exchange
reduction, spraying, dispersing of water drops, drain pump malfunction, etc.
In these cases, take the following actions:
• Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient
capacity so that it draws oily steam which should not flow into the suction of the air
conditioner.
• Make enough distance from a cooking room to install the air conditioner in such a place
where it may not suck in oily steam.
NOTICE
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table
Air conditioner
Take enough
distance
Wall
5~7mm
Indoor Outdoor
Set screw of
paper model (4 pieces)
Paper model
for installation
Ceiling board
90mm
Adjust the same height
Ceiling board
Ceiling
Flat washer for M10
(accessory)
Keep the length of the bolt
from the bracket to 40mm
Open the ceiling board
along the outer edge of the
paper model
Flat washer for M10
(accessory)
Hanging bolt
(W3/8 or M10)
Nut
(W3/8 or M10)
Nut
(W3/8 or M10)
Spring washer
(M10)
Air Conditioner body
Installation Manual 15
ENGLISH
Installation
Remote Controller Installation
• The following parts is option.
Hanging Bolt - W 3/8 or M10
Nut - W 3/8 or M10
Spring Washer - M10
Plate Washer - M10
CAUTION:
Tighten the nut and bolt
to prevent unit falling.
• Drill the piping hole on the wall slightly tilted to the
outdoor side using a Ø 70 hole-core drill.
• Although the room temperature sensor is in the indoor unit, the remote controller should
be installed in such places away from direct sunlight and high humidity.
Installation of the remote controller
Select places that are not splashed with water.
• Select control position after receiving customer approval.
The room temperature sensor is built in the indoor unit.
This remote controller equipped with liquid crystal display. If this position is higher or lower,
display is difficult to see.(The standard height is 1.2 ~ 1.5m high)
Routing of the remote controller cord
• Keep the remote controller cord away from the refrigerant piping and the drain piping.
To protect the remote controller cord from electrical noise, place the cord at least 5cm away
from other power cables (audio equipment, television set, etc.)
• If the remote controller cord is secured to the wall, provide a trap at the top of the cord to
prevent water droplets from running.
Remote control
box body
Cord clamp
(accessory)
Lever carefully
the box open
using a screw
driver, etc.
Front case
The l
o
w
er par
t
Face of wall
Under plate
Screw (accessory)
16 MPS Multi Air Conditioner
Installation
HOW TO MOUNT ONTO A WALL
HOW TO INSERT BATTERIES
Remove the battery cover from the remote
controller.
• Slide the cover according to the arrow
direction.
Insert the two batteries.
• Be sure that the (+) and (-) directions are
correct.
• Be sure that both batteries are new.
Re-attach the cover.
Slide it back into position.
• Fix the under plate on the wall
• Separate the under plate from Remote control box.
• Fix the cord clamps on the wall by
ø 3 tapping screws (accessory).
• Fix the remote control cord.
DISASSEMBLING
ELECTRICAL WIRING
Remote Control Preparation(OPTIONAL)
WIRED REMOTE CONTROL INSTALLATION
Wire and make sure that teminal
numbers are matched on unit side and
remote controller side.
The maximum length of the cord is 100m.
If the length of the cord exceeds 50m,
use a wire size greater than 0.5mm
2
.
Remote controller
(Main board)
CN REMO
• Do not use rechargeable
batteries, such batteries differ
from standard dry cells in
shape, dimensions, and
performance.
• Romove the batteries from the
remote controller if the air
conditioner is not going to be
used for some long time.
Installation Manual 17
Installation
Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the
following procedure.
Cut the pipes and the cable.
1. Use the piping kit accessory or the pipes
purchased locally.
2. Measure the distance between the indoor and
the outdoor unit.
3. Cut the pipes a little longer than measured
distance.
4. Cut the cable 1.5m longer than the pipe length.
Burrs removal
1. Completely remove all burrs from the cut cross
section of pipe/tube.
2. Put the end of the copper tube/pipe in a
downward direction as you remove burrs in
order to avoid dropping burrs into the tubing.
Putting nut on
Remove flare nuts attached to indoor and
outdoor unit, then put them on pipe/tube having
completed burr removal.
(not possible to put them on after flaring work)
Flaring work
1. Firmly hold copper pipe in a die in the dimension
shown in the table below.
2. Carry out flaring work with the flaring tool.
Copper
pipe
90°
Slanted Uneven Rough
Pipe
Reamer
Point down
Flare nut
Copper tube
mm inch mm
Ø 6.35 1/4 0~0.5
Ø 9.52 3/8 0~0.5
Ø 12.7 1/2 0~0.5
Ø 15.88 5/8 0~1.0
Ø 19.05 3/4 1.0~1.3
Outside diameter A
Bar
Copper pipe
Clamp handle
Red arrow mark
Cone
Yoke
Handle
Bar
"
A
"
Flaring Work
H
S
I
LG
N
E
18 MPS Multi Air Conditioner
Installation
Check
1. Compare the flared work with the figure by.
2. If a flared section is defective, cut it off and
do flaring work again.
Indoor
1. Prepare the indoor unit's piping and drain hose
for installation through the wall.
2. Remove the plastic tubing retainer(see the
illustration by) and pull the tubing and drain
hose away from chassis.
3. Replace only the plastic tubing holder 1, not
the holder 2 in the original position.
Inclined
Inside is shiny without scratches
Smooth all round
Even length
all round
Surface
damaged
Cracked Uneven
thickness
= Improper flaring =
For right rear piping
Connecting the Piping - Indoor
Preparing the indoor unit's piping and drain hose for installation through the wall.
1. Route the indoor tubing and the drain hose in the direction of rear left or right
2. Tape the tubing, drain hose and the connecting cable. Be sure that the drain hose is located at
the Lowest side of the bundle.Locating at the upper side can cause drain pan to overow inside the unit
Drain hose
Connecting
pipe
Connecting cable
Tape
Drain hose
Drain hose
Connecting
pipe
Connecting cable
Tape
Drain hose
CAUTION: If the drain hose is routed inside the room, insulate the hose with an insulation
material* so that dripping from “sweating”(condensation) will not damagefurniture or floors.
*Foamed polyethylene or equivalent is recommended
Installation Manual 19
Installation
4. Indoor unit installation
Hook the indoor unit onto the upper portion of
the installation plate.(Engage the two hooks
of the rear top of the indoor unit with the
upper edge of the installation plate.) Ensure
that the hooks are properly seated on the
installation plate by moving it left and right.
Press the lower left and right sides of the unit
against the installation plate until the hooks
engage into their slots(clicking sound).
Connecting the piping to the indoor unit and
drain hose to drain pipe.
1. Align the center of the pipes and sufficiently
tighten the flare nut by hand.
2. Tighten the flare nut with a wrench.
3. When extending the drain hose at the indoor
unit, install the drain pipe.
Wrap the insulation material around the
connecting portion.
1. Overlap the connection pipe insulation
material and the indoor unit pipe insulation
material. Bind them together with vinyl tape
so that there may be no gap.
2. Wrap the area which accommodates the rear
piping housing section with vinyl tape.
3. Bundle the piping and drain hose together by
wrapping them with vinyl tape for enough to
cover where they fit into the rear piping
housing section.
Drain hose
Connecting
cable
Indoor unit tubing Flare nut Pipes
Wrench
Indoor unit tubing
Open-end wrench (fixed)
Connection pipe
Flare nut
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit drain hose
Plastic bands
Insulation material
Vinyl tape(narrow)
Connection pipe
Connecting cable
Vinyl tape (wide)
Wrap with vinyl tape
Indoor unit pipe
Pipe
Wrap with vinyl tape
Drain hose
Pipe
Vinyl tape(wide)
mm inch kg
.
m
Ø6.35 1/4 1.8
Ø9.52 3/8 4.2
Ø12.7 1/2 5.5
Ø15.88 5/8 6.6
Outside diameter Torque
H
S
I
L
G
NE
20 MPS Multi Air Conditioner
Installation
1. Route the indoor tubing and the drain hose to
the required piping hole position.
2. Insert the piping, drain hose, and the
connecting cable into the piping hole.
3.
Insert the connecting cable into the indoor unit.
Don't connect the cable to the indoor unit.
Make a small loop with the cable for easy
connection later.
4. Tape the drain hose and the connecting
cables.
5. Indoor unit installation
Hang the indoor unit from the hooks at the
top of the installation plate.
Insert the spacer etc. between the indoor
unit and the installation plate and separate
the bottom of the indoor unit from the wall.
Connecting the piping to the indoor unit and
the drain hose to drain pipe.
1. Align the center of the pipes and sufficiently
tighten the flare nut by hand.
2. Tighten the flare nut with a wrench.
3. When extending the drain hose at the indoor
unit, install the drain pipe.
For left rear piping
Drain pipe
Connecting
cable
1 2
Installation plate
Spacer
Indoor unit
8cm
Indoor unit tubing Flare nut Pipes
Wrench
Indoor unit tubing
Connection pipe
Flare nut
Open-end wrench (fixed)
Vinyl tape
Adhesive
Drain hose
Indoor unit drain hose
(narrow)
mm inch kg
.
m
Ø6.35 1/4 1.8
Ø9.52 3/8 4.2
Ø12.7 1/2 5.5
Ø15.88 5/8 6.6
Outside diameter Torque
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

LG HMNC126D4A0 Owner's manual

Category
Cookers
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI