FMI BK2-LS Operating instructions

Type
Operating instructions

This manual is also suitable for

INSTALLATION INSTRUCTIONS FOR MODEL BK2 FAN KIT
DUAL FAN BLOWER SYSTEM
Figure 1 - BK2 Dual Fan Assembly
Figure 2 - Removing Glass Doors
Save these instructions for future reference
Figure 3 - Accessing Blower Compartment
Spring Clip
Press Spring
Clip Up to
Release Pivot
Pin
Fold Bi-Fold Door After
Releasing Spring Clip to
Slide Door Out of Upper
Portion
Pivot Hole
Fan
Assembly
Supports
Figure 4 - Mounting Blower
The Model BK2 blower system (see Figure 1) can be install
in any existing circulating model wood-burning or unvented
rebox having a prewired 120 VAC duplex power receptacle.
CAUTION: Turn off gas supply, disconnect electric
circuit and allow the appliance to fully cool down before
performing this installation. Glass and refractory panels
may be heavy for some individuals. Two people may be
required to perform this installation.
ACCESSING BLOWER COMPARTMENT
1. Fold doors (fully open) and press up on the upper door
spring clip until top pin is free of the spring clip. Tip door
toward middle of replace opening and lift door out of
lower pivot hole (see Figure 2).
2. Remove front refractory access panel by lifting up and
angling out through the replace opening (see Figure 3).
3. Remove the control cover panel.
4. Remove lower louver panel (if installed) by gently pushing
out the panel from inside the mounting frame.
5. Remove knockout plug from lower louver panel (see
Figure 3).
6. Place fan assembly with blades pointing towards the rear
of the replace and in between the two leg stands (see
Figure 4).
7. Using screws provided, fasten end anges to supports
with remaining 4 screws (see Figure 4).
Note: The wire assembly must be arranged in front of and
away from fan blades to reach power receptacle plug.
Refractory
Access Panel
Louver
Panel
Control
Cover
Knockout Plug
2
MOUNTING AND CONNECTING SWITCH
1. Remove the 2 connectors from the ON/OFF rocker switch
located on the wiring (see Figure 5).
2. Insert rocker switch into lower louver panel with switch
lever pointing outward.
3. Reconnect previously removed wire connectors into
switch terminals.
4. Insert supply plug into one of the available power recep-
tacles at right of compartment (see Figure 5).
IMPORTANT: Be sure to inspect components and wir-
ing for damage before restoring power to the appliance.
If damaged, contact an authorized dealer for original
replacement parts or call FMI PRODUCTS, LLC at
1-866-328-4537 for referral.
COMPLETE THE INSTALLATION
1. Reinstall the louver panel (if equiped) into the frame
opening of the louvers pointing down.
2. Apply wiring diagram label (see Figure 6) to control cover.
Replace control cover.
3. Reinstall front refractory panel and glass doors in reverse
order in Figure 2, page 1.
4. To operate, turn rocker switch to ON position.
Blower Rocker
Switch
Power
Supply Plug
Power
Receptacle
Wire
Connectors
Figure 5 - Connecting Switch and Supply Plug
Figure 6 - Wiring Diagram
Switch
Black
On/Off
110/115
V.A.C.
Hot
Nuetral
Black
Blower
Motor
No. 1 No. 2
Motor
Blower
118280-01
REV. B
02/11
2701 S. Harbor Blvd.
Santa Ana, CA 92704
1-866-328-4537
www.fmiproducts.com