Fittingofthe3returnairgrilles/filters
Providedthecupboardis540mmwideormore,
thethreegrillescanbeinstalledsidebysidein
theundersideofthecupboard.(Referfig.7)
Inthecaseofpoptopvans,itmaybeconvenient
toinstalloneofthethreethroughthetop. Make
surehowever,thatallthreeareinstalled.
Placethegrillesasfarbackasispossibleto
allowthemostdirectrouteoftheairtothefan
inlet.
Cutoutsizeforeachgrilleis158x232.
Thefollowingdescribestheprocedureforboth a
cupboardwitharemovablefront,andacupboard
withafrontthatisnoteasilydisassembled.
Typicallythelattertypewillhave4to5mmply
whichwillneedreinforcingaroundtheperimeter
ofthecutouta
ndtyingtothemainstructural
membersofthecupboardassy.
Drillholesatthecornersofthecutouttoallow a
jigsawtocutouttheentirecutaway.
Itisimportanttocuttheholeoutaccurately.
Ifthefrontpanelisasolid19mmpanel,the
A/Hwillnotneedadditionalsupport.If
howeverthefrontpanelislightply,thenthis
mustbestrengthenedaftercuttingoutasper
thetemplate.Thisframingshouldbe20mm
thicktoprovidethenecessarysupport,and
shouldtieinwiththemaincupboard
members,tosupporttheweightofthe
Airhandler.
Thefrontpanelcannowbefittedandscrewed
intoplace.
Installationoftherefrigerationpipe
workandcondensatedrain
The9.4mmØandthe6.4Øpipescanenter
eithersideofthecupboard,andbecarefully
manipulatedtomaketheconnectiontothe
Airhandler.The9.4Øpipemustbeinsulated
entirely.
Thecondensatedrainisnormallyrunvertically.
12mmhoseorpolypipeispreferred.Anelbow
isprovidedintheinstallationkittochange
directionfromtheverticalruntothehorizontal
toconnecttheairhandler.Failuretousethis
elbowusuallyresultsinahumpinthedrain
whichmayimpededrainage,orakink.
Figure 7
7
DRAINELBOW
Figure 8
DRAIN HOSEFALLSAWAYCONTINUOUSLY
RETURNAIRGRILLESX 3
Figure 9
Back ofCupboard
90Min.
Drain Connection
ReturnAirGrille (3off)
Front of Cupboard
AIRHANDLER
Make out the cut out as per fig 6a.