Dell EMC OpenManage Plug-in v3.0 for Nagios Core User guide

Type
User guide
Nagios Core์šฉ Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ
๋ฒ„์ „ 3.0
์‚ฌ์šฉ์ž ์„ค๋ช…์„œ
์ฐธ๊ณ , ์ฃผ์˜ ๋ฐ ๊ฒฝ๊ณ 
๋…ธํŠธ: "์ฐธ๊ณ "๋Š” ์ œํ’ˆ์„ ๋ณด๋‹ค ํšจ์œจ์ ์œผ๋กœ ์‚ฌ์šฉํ•˜๋Š” ๋ฐ ๋„์›€์ด ๋˜๋Š” ์ค‘์š” ์ •๋ณด๋ฅผ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค.
์ฃผ์˜: "์ฃผ์˜"๋Š” ํ•˜๋“œ์›จ์–ด ์†์ƒ์ด๋‚˜ ๋ฐ์ดํ„ฐ ์†์‹ค์˜ ๊ฐ€๋Šฅ์„ฑ์„ ์„ค๋ช…ํ•˜๋ฉฐ, ์ด๋Ÿฌํ•œ ๋ฌธ์ œ๋ฅผ ๋ฐฉ์ง€ํ•  ์ˆ˜ ์žˆ๋Š” ๋ฐฉ๋ฒ•์„ ์•Œ๋ ค์ค๋‹ˆ๋‹ค.
๊ฒฝ๊ณ : "๊ฒฝ๊ณ "๋Š” ์žฌ์‚ฐ์ƒ์˜ ํ”ผํ•ด๋‚˜ ์‹ฌ๊ฐํ•œ ๋ถ€์ƒ ๋˜๋Š” ์‚ฌ๋ง์„ ์œ ๋ฐœํ•  ์ˆ˜ ์žˆ๋Š” ์œ„ํ—˜์ด ์žˆ์Œ์„ ์•Œ๋ ค์ค๋‹ˆ๋‹ค.
ยฉ 2015 -2018 Dell Inc. ๋˜๋Š” ์žํšŒ์‚ฌ. ์ €์ž‘๊ถŒ ๋ณธ์‚ฌ ์†Œ์œ . Dell, EMC ๋ฐ ๊ธฐํƒ€ ์ƒํ‘œ๋Š” Dell Inc. ๋˜๋Š” ์žํšŒ์‚ฌ์˜ ์ƒํ‘œ์ž…๋‹ˆ๋‹ค. ๊ธฐํƒ€ ์ƒํ‘œ๋Š” ๊ฐ ์†Œ์œ ์ž์˜ ์ƒํ‘œ์ผ
์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.
2018 - 04
๊ฐœ์ • A00
๋ชฉ์ฐจ
1 Nagios Core์šฉ Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ๋ฒ„์ „ 3.0 ์†Œ๊ฐœ..................................................................... 5
2 Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ๋ฒ„์ „ 3.0์˜ ์ƒˆ๋กœ์šด ๊ธฐ๋Šฅ............................................................................. 6
3 ์ฃผ์š” ํŠน์ง•.......................................................................................................................................................8
4 Support matrix...............................................................................................................................................9
Datacenter Scalable Solutions..........................................................................................................................................9
Hyper-converged Infrastructure (HCI) Platforms..........................................................................................................9
PowerEdge Servers..........................................................................................................................................................10
PowerEdge Chassis..........................................................................................................................................................10
Compellent SC-Series Storage Arrays............................................................................................................................11
EqualLogic PS-Series Storage Arrays............................................................................................................................. 11
PowerVault MD-Series Storage Arrays ..........................................................................................................................11
Dell EMC Network Switches...........................................................................................................................................12
5 ์žฅ์น˜ ๊ฒ€์ƒ‰ ๋ฐ ์ธ๋ฒคํ† ๋ฆฌ..................................................................................................................................13
About device discovery....................................................................................................................................................13
About Dell EMC device discovery utility........................................................................................................................ 14
Dell EMC ์žฅ์น˜ ๊ฒ€์ƒ‰......................................................................................................................................................... 18
์žฅ์น˜ ์ •๋ณด.......................................................................................................................................................................... 19
์žฅ์น˜ ์ •๋ณด.................................................................................................................................................................... 19
์žฅ์น˜ ์ •๋ณด ๋ณด๊ธฐ........................................................................................................................................................... 21
6 Dell EMC ์žฅ์น˜ ๋ชจ๋‹ˆํ„ฐ๋ง.............................................................................................................................. 22
Dell EMC ์žฅ์น˜์˜ ์ „์ฒด ์ƒํƒœ...........................................................................................................................................22
์ƒํƒœ ์ธ์Šคํ„ด์Šค........................................................................................................................................................... 22
์ „์ฒด ์ƒํƒœ ์ •๋ณด.......................................................................................................................................................... 22
์ „์ฒด ์ƒํƒœ ๋ณด๊ธฐ.......................................................................................................................................................... 23
Dell EMC ์žฅ์น˜์˜ ๊ตฌ์„ฑ์š”์†Œ ์ƒํƒœ ๋ชจ๋‹ˆํ„ฐ๋ง.................................................................................................................23
About monitoring component health of Dell EMC devices...................................................................................24
Dell EMC ์žฅ์น˜์˜ ๊ตฌ์„ฑ์š”์†Œ ์ƒํƒœ ๋ชจ๋‹ˆํ„ฐ๋ง............................................................................................................31
Viewing Dell EMC devices in the Nagios Core console..........................................................................................31
SNMP ๊ฒฝ๊ณ  ๋ชจ๋‹ˆํ„ฐ๋ง.....................................................................................................................................................32
SNMP ๊ฒฝ๊ณ  ๋ชจ๋‹ˆํ„ฐ๋ง ์ •๋ณด..................................................................................................................................... 32
SNMP ๊ฒฝ๊ณ  ๋ณด๊ธฐ....................................................................................................................................................... 34
7 Dell EMC ์žฅ์น˜ ํŠน์ • ์ฝ˜์†” ์‹คํ–‰..................................................................................................................... 35
Dell EMC ์žฅ์น˜ ๋ฐ ํ•ด๋‹น ์ฝ˜์†”..........................................................................................................................................35
8 Dell EMC ์žฅ์น˜์— ๋Œ€ํ•œ ๋ณด์ฆ ์ •๋ณด..................................................................................................................36
๋ณด์ฆ ์ •๋ณด ํŠน์„ฑ................................................................................................................................................................ 36
๋ชฉ์ฐจ 3
Dell EMC ๋ณด์ฆ ์ •๋ณด ๋งค๊ฐœ๋ณ€์ˆ˜ ๊ตฌ์„ฑ............................................................................................................................. 36
๋ณด์ฆ ์ •๋ณด ๋ณด๊ธฐ.................................................................................................................................................................37
9 Dell EMC ์žฅ์น˜ ์ œ๊ฑฐ..................................................................................................................................... 38
10 Knowledge Base messages for the generated alerts...................................................................................39
Viewing KB messages..................................................................................................................................................... 39
11 ๋ฌธ์ œ ํ•ด๊ฒฐ.................................................................................................................................................... 40
SNMP ํŠธ๋žฉ์ด Ubuntu ์„ค์ •์šฉ Nagios Core ์ฝ˜์†”์˜ Dell EMC ์žฅ์น˜์—์„œ ์ˆ˜์‹ ๋˜์ง€ ์•Š์Šต๋‹ˆ๋‹ค............................ 40
Nagios ์ฝ˜์†”์ด eqlMemberGatewayIPAddrChanged ํŠธ๋žฉ์„ ๊ฐ€์ ธ์˜ค์ง€ ์•Š์Šต๋‹ˆ๋‹ค................................................. 40
Nagios Core์šฉ Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ์„ค์น˜ ์Šคํฌ๋ฆฝํŠธ์— ์˜ค๋ฅ˜๊ฐ€ ๋ฐœ์ƒํ•ฉ๋‹ˆ๋‹ค................................... 40
Nagios Core์šฉ Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ์ œ๊ฑฐ ์Šคํฌ๋ฆฝํŠธ์— ์˜ค๋ฅ˜๊ฐ€ ๋ฐœ์ƒํ•ฉ๋‹ˆ๋‹ค................................... 40
๊ฒ€์ƒ‰ ์Šคํฌ๋ฆฝํŠธ๋ฅผ ์‹คํ–‰ํ•˜์ง€ ๋ชปํ–ˆ์Šต๋‹ˆ๋‹ค......................................................................................................................40
๊ฒ€์ƒ‰ ์Šคํฌ๋ฆฝํŠธ๊ฐ€ IPv4 ๋˜๋Š” IPv6 ์ฃผ์†Œ ๋˜๋Š” ํ˜ธ์ŠคํŠธ์— ๋Œ€ํ•œ ํ˜ธ์ŠคํŠธ ๋ฐ ์„œ๋น„์Šค ์ •์˜ ํŒŒ์ผ์„ ์ƒ์„ฑํ•˜์ง€ ์•Š
์Šต๋‹ˆ๋‹ค................................................................................................................................................................................41
์žฅ์น˜ ๊ฒ€์ƒ‰ ํ›„์— Dell EMC ์žฅ์น˜์˜ IP ์ฃผ์†Œ ๋˜๋Š” ํ˜ธ์ŠคํŠธ ์ด๋ฆ„์ด ๋ณ€๊ฒฝ๋ฉ๋‹ˆ๋‹ค..........................................................41
Nagios Core ์ฝ˜์†”์— Dell ๊ฒ€์ƒ‰ ์Šคํฌ๋ฆฝํŠธ๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ ๊ฒ€์ƒ‰๋œ Dell EMC ์žฅ์น˜๊ฐ€ ํ‘œ์‹œ๋˜์ง€ ์•Š์Šต๋‹ˆ๋‹ค.................41
Nagios Core ์ฝ˜์†”์— Dell EMC ๊ฒ€์ƒ‰ ์Šคํฌ๋ฆฝํŠธ๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ ๊ฒ€์ƒ‰๋œ Dell EMC ์žฅ์น˜์˜ ํŠธ๋žฉ ์„œ๋น„์Šค๊ฐ€ ํ‘œ์‹œ
๋˜์ง€ ์•Š์Šต๋‹ˆ๋‹ค.................................................................................................................................................................. 41
Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ํŠน์ • ์„œ๋น„์Šค์— "SNMP ์„ธ์…˜์„ ์ƒ์„ฑํ•˜๋Š” ์ค‘ ์˜ค๋ฅ˜ ๋ฐœ์ƒ" ๋ฉ”์‹œ์ง€๊ฐ€ ํ‘œ
์‹œ๋ฉ๋‹ˆ๋‹ค............................................................................................................................................................................41
Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ํŠน์ • ์„œ๋น„์Šค์— "ํ˜ธ์ŠคํŠธ์™€ ํ†ต์‹ ํ•˜๋Š” ์ค‘์— Red๎‚€sh ์˜ค๋ฅ˜๊ฐ€ ๋ฐœ์ƒํ–ˆ์Šต๋‹ˆ
๋‹ค." ๋ฉ”์‹œ์ง€๊ฐ€ ํ‘œ์‹œ๋ฉ๋‹ˆ๋‹ค..............................................................................................................................................42
Nagios Core ์ฝ˜์†”์—์„œ Dell EMC ์žฅ์น˜๊ฐ€ ์ƒ์„ฑํ•œ SNMP ๊ฒฝ๊ณ ๋ฅผ ๋ณผ ์ˆ˜ ์—†์Šต๋‹ˆ๋‹ค................................................. 42
๊ฒ€์ƒ‰ํ•œ Dell EMC ์žฅ์น˜์— ๋Œ€ํ•œ ๋ณด์ฆ ์ •๋ณด๋ฅผ Nagios Core ์ฝ˜์†”์—์„œ ๋ชจ๋‹ˆํ„ฐ๋งํ•  ์ˆ˜ ์—†์Šต๋‹ˆ๋‹ค...........................42
Dell EMC ์žฅ์น˜ ๊ฒฝ๊ณ ๋ฅผ ์ˆ˜์‹ ํ•œ ํ›„์— ์ „์ฒด ์ƒํƒœ๊ฐ€ ์ƒˆ๋กœ ๊ณ ์ณ์ง€์ง€ ์•Š์Šต๋‹ˆ๋‹ค......................................................... 42
Nagios Management Server IP ์ฃผ์†Œ๊ฐ€ ๋ณ€๊ฒฝ๋œ ํ›„ ์žฅ์น˜ ํŠธ๋žฉ์—์„œ KB ์ •๋ณด๋ฅผ ๋ณผ ์ˆ˜ ์—†์Šต๋‹ˆ๋‹ค...........................43
12 FAQ(์ž์ฃผํ•˜๋Š” ์งˆ๋ฌธ)...................................................................................................................................44
๋ถ€๋ก A: ๋ถ€๋ก................................................................................................................................................... 45
iDRAC ์›น ์ฝ˜์†”์„ ์‚ฌ์šฉํ•˜์—ฌ iDRAC์˜ SNMP ๋งค๊ฐœ๋ณ€์ˆ˜ ๊ตฌ์„ฑ...................................................................................45
iDRAC ์›น ์ฝ˜์†”์„ ์‚ฌ์šฉํ•˜์—ฌ iDRAC์˜ SNMP ํŠธ๋žฉ ๋Œ€์ƒ ์ฃผ์†Œ ๊ตฌ์„ฑ........................................................................ 45
4 ๋ชฉ์ฐจ
Nagios Core์šฉ Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ
๋ฒ„์ „ 3.0 ์†Œ๊ฐœ
์ด ์•ˆ๋‚ด์„œ๋Š” Nagios Core์šฉ Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ๋ฒ„์ „ 3.0 ๋ฐ ์ง€์›๋˜๋Š” Dell EMC ์žฅ์น˜ ๊ฒ€์ƒ‰, ๋ชจ๋‹ˆํ„ฐ๋ง, ์ฝ˜์†” ์‹œ์ž‘ ๋ฐ ๋ฌธ์ œ ํ•ด
๊ฒฐ๊ณผ ๊ฐ™์€ ๋‹ค์–‘ํ•œ ๊ธฐ๋Šฅ ์‚ฌ์šฉ์— ๋Œ€ํ•œ ์ •๋ณด๋ฅผ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค. ๋˜ํ•œ ์ง€์›๋˜๋Š” Dell EMC ์žฅ์น˜์˜ ์„ธ๋ถ€ ์ •๋ณด์™€ ๊ณ ๊ฐ FAQ(frequently Asked
Questions)๋ฅผ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค.
์ด ํ”Œ๋Ÿฌ๊ทธ์ธ์€ Nagios Core๊ฐ€ ๊ด€๋ฆฌํ•˜๋Š” ํ™˜๊ฒฝ์—์„œ Dell EMC ์žฅ์น˜๋ฅผ ๋ชจ๋‹ˆํ„ฐ๋งํ•˜๋Š” ๊ธฐ๋Šฅ์„ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค. ์ด ํ”Œ๋Ÿฌ๊ทธ์ธ์€ ์ „์ฒด ๋ฐ ๊ตฌ์„ฑ์š”์†Œ
์ˆ˜์ค€์˜ ์ƒํƒœ ๋ชจ๋‹ˆํ„ฐ๋ง์„ ๋น„๋กฏํ•˜์—ฌ Dell EMC ์žฅ์น˜์— ๋Œ€ํ•œ ์™„์ „ํ•œ ํ•˜๋“œ์›จ์–ด ์ˆ˜์ค€์˜ ๊ฐ€์‹œ์„ฑ์„ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค. ํ”Œ๋Ÿฌ๊ทธ์ธ์€ ๊ธฐ๋ณธ ์ธ๋ฒคํ† ๋ฆฌ ์ •
๋ณด์™€ Dell EMC ์žฅ์น˜์˜ ์ด๋ฒคํŠธ ๋ชจ๋‹ˆํ„ฐ๋ง์„ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค. ํ”Œ๋Ÿฌ๊ทธ์ธ์€ ์ถ”๊ฐ€ ๋ฌธ์ œ ํ•ด๊ฒฐ, ๊ตฌ์„ฑ, ๊ด€๋ฆฌ ํ™œ๋™์„ ์œ„ํ•ด ์ง€์›๋˜๋Š” Dell EMC ์žฅ์น˜์˜
์ผ๋Œ€์ผ ์›น ์ฝ˜์†” ์‹คํ–‰๋„ ์ง€์›ํ•ฉ๋‹ˆ๋‹ค.
์žฅ์น˜ ์ง€์›์— ๋Œ€ํ•œ ์ž์„ธํ•œ ๋‚ด์šฉ์€ "Nagios Core
์šฉ
Dell EMC OpenManage
ํ”Œ๋Ÿฌ๊ทธ์ธ
๋ฒ„์ „
3.0
์‚ฌ์šฉ์ž
๊ฐ€์ด๋“œ
"์˜ ์ง€์› ๋งคํŠธ๋ฆญ์Šค๋ฅผ ์ฐธ์กฐํ•˜
์‹ญ์‹œ์˜ค.
1
Nagios Core์šฉ Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ๋ฒ„์ „ 3.0 ์†Œ๊ฐœ 5
Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ๋ฒ„์ „ 3.0์˜ ์ƒˆ๋กœ
์šด
๊ธฐ๋Šฅ
๋‹ค์Œ ํ‘œ์—๋Š” Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ๋ฒ„์ „ 3.0์˜ ์ƒˆ๋กœ์šด ํŠน์ง• ๋ฐ ๊ธฐ๋Šฅ์ด ๋‚˜์—ด๋˜์–ด ์žˆ์Šต๋‹ˆ๋‹ค.
ํ‘œ 1. ์ƒˆ๋กœ์šด ํŠน์ง• ๋ฐ ๊ธฐ๋Šฅ
์ƒˆ๋กœ์šด ๊ธฐ๋Šฅ ์„ค๋ช…
์ƒˆ๋กœ์šด Dell EMC ์žฅ์น˜ ์ง€์› ์ด ๋ฒ„์ „์œผ๋กœ ๋‹ค์Œ๊ณผ ๊ฐ™์€ ์ƒˆ๋กœ์šด Dell EMC ์žฅ์น˜๋ฅผ ๊ฒ€์ƒ‰ํ•˜๊ณ  ๋ชจ๋‹ˆํ„ฐ๋งํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.
โ€ข iDRAC(Integrated Dell Remote Access Controlle) with LC(Lifecycle Controller)๋ฅผ ํ†ตํ•ด์„œ ์ƒˆ๋กญ๊ฒŒ
์ถœ์‹œ๋œ 14์„ธ๋Œ€ PowerEdge ์„œ๋ฒ„
โ€ข OEM ์„œ๋ฒ„
โ€ข Dell EMC ๋„คํŠธ์›Œํฌ ์Šค์œ„์น˜
์žฅ์น˜ ์ง€์›์— ๋Œ€ํ•œ ์ž์„ธํ•œ ๋‚ด์šฉ์€ "Nagios Core
์šฉ
Dell EMC OpenManage
ํ”Œ๋Ÿฌ๊ทธ์ธ
๋ฒ„์ „
3.0
์‚ฌ์šฉ์ž
๊ฐ€์ด๋“œ
"์˜ ์ง€์› ๋งคํŠธ๋ฆญ์Šค๋ฅผ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.
๊ตฌ์„ฑ์š”์†Œ ์ˆ˜์ค€์„ ํฌํ•จํ•œ ๊ธฐ๋ณธ
์‹œ์Šคํ…œ ์ •๋ณด ๋ชจ๋‹ˆํ„ฐ๋ง
์ด ๋ฒ„์ „์€ ๋‹ค์Œ Dell EMC ์žฅ์น˜์˜ ๊ตฌ์„ฑ์š”์†Œ ์ˆ˜์ค€ ์„ธ๋ถ€์ •๋ณด๋ฅผ ํฌํ•จํ•œ ๊ธฐ๋ณธ ์‹œ์Šคํ…œ ์ •๋ณด๋ฅผ ์ œ๊ณตํ•ฉ๋‹ˆ
๋‹ค.
โ€ข 14์„ธ๋Œ€ PowerEdge ์„œ๋ฒ„
โ€ข OEM ์„œ๋ฒ„
โ€ข Dell EMC ๋„คํŠธ์›Œํฌ ์Šค์œ„์น˜
์ตœ์‹  ํŽŒ์›จ์–ด ๋ฒ„์ „ ์ด ๋ฒ„์ „์€ ๋‹ค์Œ Dell EMC ์žฅ์น˜์˜ ์ตœ์‹  ํŽŒ์›จ์–ด ๋ฒ„์ „์„ ์ง€์›ํ•ฉ๋‹ˆ๋‹ค.
โ€ข 14์„ธ๋Œ€ PowerEdge ์„œ๋ฒ„(iDRAC9)
โ€ข 12์„ธ๋Œ€ ๋ฐ 13์„ธ๋Œ€ PowerEdge ์„œ๋ฒ„(iDRAC7 ๋ฐ iDRAC8)
โ€ข Datacenter Scalable Solutions(DSS)
โ€ข PowerEdge FX2/FX2s ์„€์‹œ
โ€ข PowerEdge VRTX ์„€์‹œ
โ€ข PowerEdge M1000e ์„€์‹œ
โ€ข EqualLogic PS Series ์Šคํ† ๋ฆฌ์ง€ ์–ด๋ ˆ์ด
โ€ข PowerVault MD 34/38 Series ์Šคํ† ๋ฆฌ์ง€ ์–ด๋ ˆ์ด
โ€ข Compellent ์Šคํ† ๋ฆฌ์ง€ ์–ด๋ ˆ์ด
Nagios Core์šฉ Dell EMC
OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ๋ฒ„์ „ 3.0
์œผ๋กœ ์—…๊ทธ๋ ˆ์ด๋“œ
Nagios Core์šฉ Dell OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ๋ฒ„์ „ 1.0 ๋ฐ Nagios Core์šฉ Dell EMC OpenManage ํ”Œ๋Ÿฌ
๊ทธ์ธ ๋ฒ„์ „ 2.1์—์„œ Nagios Core์šฉ Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ๋ฒ„์ „ 3.0์œผ๋กœ ์—…๊ทธ๋ ˆ์ด๋“œํ•  ์ˆ˜
์žˆ์Šต๋‹ˆ๋‹ค.
SNMP ๊ฒฝ๊ณ  ๋ณด๊ธฐ ๋ฐ ๋ชจ๋‹ˆํ„ฐ๋ง ์ง€์›๋˜๋Š” ์žฅ์น˜์—์„œ SNMP ๊ฒฝ๊ณ ๋ฅผ ๋ณด๊ณ  ๋ชจ๋‹ˆํ„ฐ๋งํ•ฉ๋‹ˆ๋‹ค.
ํŠธ๋žฉ ๊ธฐ๋ฐ˜ ์ƒํƒœ ๋ชจ๋‹ˆํ„ฐ๋ง ์ง€์›๋˜๋Š” ์žฅ์น˜์˜ ํŠธ๋žฉ ๊ธฐ๋ฐ˜ ์ƒํƒœ ๋ชจ๋‹ˆํ„ฐ๋ง์ž…๋‹ˆ๋‹ค.
Dell EMC ์žฅ์น˜ ํŠน์ • ์ฝ˜์†” ์‹คํ–‰ ๋‹ค์Œ๊ณผ ๊ฐ™์€ Dell EMC ์ผ๋Œ€์ผ ์ฝ˜์†” ์‹คํ–‰์„ ์ง€์›ํ•˜์—ฌ ์ง€์›๋˜๋Š” Dell EMC ์žฅ์น˜์— ๋Œ€ํ•œ ์ถ”๊ฐ€ ๋ฌธ์ œ ํ•ด
๊ฒฐ, ๊ตฌ์„ฑ ๋˜๋Š” ๊ด€๋ฆฌ ์ž‘์—…์„ ์ˆ˜ํ–‰ํ•ฉ๋‹ˆ๋‹ค.
โ€ข OEM ์„œ๋ฒ„์˜ iDRAC ์ฝ˜์†”
โ€ข HCI ์žฅ์น˜์— ๋Œ€ํ•œ HCI ์ฝ˜์†” ์‹œ์ž‘
2
6 Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ๋ฒ„์ „ 3.0์˜ ์ƒˆ๋กœ์šด ๊ธฐ๋Šฅ
์ƒˆ๋กœ์šด ๊ธฐ๋Šฅ ์„ค๋ช…
โ€ข Dell EMC ๋„คํŠธ์›Œํฌ ์Šค์œ„์น˜
๋ณด์ฆ ์ •๋ณด ๋ณด๊ธฐ ์ด ๊ธฐ๋Šฅ์„ ์‚ฌ์šฉํ•˜๋ฉด OEM ์„œ๋ฒ„ ๋ฐ Dell EMC ๋„คํŠธ์›Œํฌ ์Šค์œ„์น˜์— ๋Œ€ํ•œ ๋ณด์ฆ ์ •๋ณด๋ฅผ ๋ณผ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.
๊ธฐ์ˆ  ๋ฌธ์„œ(KB) ๋ฉ”์‹œ์ง€ ๋ณด๊ธฐ ์ด๋Ÿฌํ•œ ๊ฒฝ๊ณ ์™€ ์—ฐ๊ด€๋œ KB ๋ฌธ์„œ๋ฅผ ํ†ตํ•ด SNMP ๊ฒฝ๊ณ ์— ๋Œ€ํ•œ ์ž์„ธํ•œ ์ •๋ณด๋ฅผ ์–ป์„ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. OEM
์„œ๋ฒ„ ๋ฐ HCI ํ”Œ๋žซํผ์— ๋Œ€ํ•œ KB ๋ฉ”์‹œ์ง€๋ฅผ ๋ณผ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.
Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ๋ฒ„์ „ 3.0์˜ ์ƒˆ๋กœ์šด ๊ธฐ๋Šฅ 7
์ฃผ์š” ํŠน์ง•
Nagios Core์šฉ Dell EMC OpenManage ํ”Œ๋Ÿฌ๊ทธ์ธ ๋ฒ„์ „ 3.0์˜ ์ฃผ์š” ํŠน์ง•์€ ๋‹ค์Œ ํ‘œ์— ์„ค๋ช…๋œ ๋ฐ”์™€ ๊ฐ™์Šต๋‹ˆ๋‹ค.
ํ‘œ 2. ์ฃผ์š” ํŠน์ง•
๊ธฐ๋Šฅ ๊ธฐ๋Šฅ์„ฑ
์žฅ์น˜ ๊ฒ€์ƒ‰
Nagios Core ์ฝ˜์†”์—์„œ ์ง€์›๋˜๋Š” Dell EMC ์žฅ์น˜๋ฅผ ๊ฒ€์ƒ‰ํ•ฉ๋‹ˆ๋‹ค. ๊ฒ€์ƒ‰์ด ์™„๋ฃŒ๋˜๋ฉด ๊ฐ ์žฅ
์น˜์˜ ํ˜ธ์ŠคํŠธ ๋ฐ ์„œ๋น„์Šค ์ •์˜๊ฐ€ ์ƒ์„ฑ๋ฉ๋‹ˆ๋‹ค.
โ€ข SNMP ๋˜๋Š” WSMan ํ”„๋กœํ† ์ฝœ ๋˜๋Š” Red๎‚€sh REST API๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ iDRAC ์žฅ์น˜๋ฅผ ๊ฒ€
์ƒ‰ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.
โ€ข Dell EMC ์Šคํ† ๋ฆฌ์ง€ ๋ฐ Dell EMC Network Switch ๊ฒ€์ƒ‰์€ SNMP ํ”„๋กœํ† ์ฝœ์„ ์‚ฌ์šฉํ•˜
์—ฌ ์ง€์›๋ฉ๋‹ˆ๋‹ค.
โ€ข Dell EMC ์„€์‹œ ๊ฒ€์ƒ‰์€ WSMan ํ”„๋กœํ† ์ฝœ์„ ์‚ฌ์šฉํ•˜์—ฌ ์ง€์›๋ฉ๋‹ˆ๋‹ค.
์žฅ์น˜ ์ •๋ณด
์žฅ์น˜ ๊ฒ€์ƒ‰์— ์„ฑ๊ณตํ•œ ํ›„ ๊ฒ€์ƒ‰๋œ ์žฅ์น˜์— ๋Œ€ํ•œ ์ •๋ณด(์„œ๋น„์Šค ํƒœ๊ทธ, ํŽŒ์›จ์–ด ๋ฒ„์ „, ์žฅ์น˜ ์ด๋ฆ„,
์žฅ์น˜ ๋ชจ๋ธ ๋“ฑ)์™€ ํ•ด๋‹น ๊ตฌ์„ฑ ์š”์†Œ์— ๋Œ€ํ•œ ์ •๋ณด(์‹ค์ œ ๋””์Šคํฌ, ์ „์› ๊ณต๊ธ‰ ์žฅ์น˜, ์˜จ๋„ ํ”„๋กœ
๋ธŒ, ์ „์•• ํ”„๋กœ๋ธŒ๋Š” ๋“ฑ)๋ฅผ ํ‘œ์‹œํ•ฉ๋‹ˆ๋‹ค. Nagios Core ์ฝ˜์†”์˜ ํ˜ธ์ŠคํŠธ ๋˜๋Š” ์„œ๋น„์Šค ๋ณด๊ธฐ์—
์„œ ์ด ์ •๋ณด๋ฅผ ๋ณผ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.
ํ”Œ๋Ÿฌ๊ทธ์ธ์—์„œ ์ œ๊ณตํ•˜๋Š” ์žฅ์น˜ ์ •๋ณด์— ๋Œ€ํ•œ ์ž์„ธํ•œ ๋‚ด์šฉ์€ ์žฅ์น˜ ์ •๋ณด๋ฅผ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.
Dell EMC ์žฅ์น˜์˜ ์ „๋ฐ˜์ ์ธ ์ƒํƒœ ๋ชจ๋‹ˆํ„ฐ๋ง
์˜ˆ์•ฝ๋œ ์ผ์ •์„ ๋”ฐ๋ฅด๊ฑฐ๋‚˜ ์ฃผ๊ธฐ์ ์œผ๋กœ Dell EMC ์žฅ์น˜์˜ ์ „๋ฐ˜์ ์ธ ์ƒํƒœ๋ฅผ ๋ชจ๋‹ˆํ„ฐ๋งํ•ฉ๋‹ˆ
๋‹ค.
Dell EMC ์žฅ์น˜์˜ ๊ตฌ์„ฑ์š”์†Œ ์ˆ˜์ค€ ์ƒํƒœ
์žฅ์น˜ ๊ตฌ์„ฑ์š”์†Œ(์‹ค์ œ ๋””์Šคํฌ, ์ „์› ๊ณต๊ธ‰ ์žฅ์น˜, ์˜จ๋„ ๊ฐ์ง€๊ธฐ, ์ „์•• ๊ฐ์ง€๊ธฐ ๋“ฑ)์˜ ์ƒํƒœ๋ฅผ
๋ชจ๋‹ˆํ„ฐ๋งํ•˜๊ณ  ์˜ˆ์•ฝ๋œ ์‹œ๊ฐ„ ๊ฐ„๊ฒฉ์— ๋งž์ถฐ Dell EMC ์žฅ์น˜ ๊ตฌ์„ฑ์š”์†Œ ์ƒํƒœ์— ๋Œ€ํ•œ ์ •๋ณด๋ฅผ
ํ‘œ์‹œํ•ฉ๋‹ˆ๋‹ค.
SNMP ๊ฒฝ๊ณ  ๋ชจ๋‹ˆํ„ฐ๋ง
Dell EMC ์žฅ์น˜์— ๋Œ€ํ•œ SNMP ๊ฒฝ๊ณ ๋ฅผ ๋ชจ๋‹ˆํ„ฐ๋งํ•ฉ๋‹ˆ๋‹ค. ์ด ๊ธฐ๋Šฅ์€ ๋งˆ์ง€๋ง‰์œผ๋กœ ์ˆ˜์‹ ํ•œ
SNMP ๊ฒฝ๊ณ ๋งŒ ํ‘œ์‹œํ•ฉ๋‹ˆ๋‹ค.
์ˆ˜์‹ ๋œ ๋ชจ๋“  SNMP ๊ฒฝ๊ณ ๋ฅผ ๋ณด๋ ค๋ฉด Nagios Core ์ฝ˜์†”์˜ ๋ณด๊ณ ์„œ > ๊ฒฝ๊ณ  > ๊ธฐ๋ก๋กœ ์ด๋™ํ•˜
์‹ญ์‹œ์˜ค.
๊ฐ ๊ฒฝ๊ณ ์˜ ๋น ๋ฅธ ๋ฌธ์ œ ํ•ด๊ฒฐ์„ ์œ„ํ•ด SNMP ๊ฒฝ๊ณ ์— ํ•ด๋‹นํ•˜๋Š” ์ง€์›๋˜๋Š” Dell EMC ์žฅ์น˜์˜
๊ฒฝ๊ณ  ๊ธฐ์ˆ  ๋ฌธ์„œ(KB) ์ •๋ณด๋ฅผ ๋ณผ ์ˆ˜๋„ ์žˆ์Šต๋‹ˆ๋‹ค.
์ž์„ธํ•œ ๋‚ด์šฉ์€ Nagios Core
์šฉ
Dell EMC OpenManage
ํ”Œ๋Ÿฌ๊ทธ์ธ
๋ฒ„์ „
3.0
์‚ฌ์šฉ์ž
๊ฐ€์ด
๋“œ
์˜ ์ƒ์„ฑ๋œ ๊ฒฝ๊ณ ์— ๋Œ€ํ•œ ๊ธฐ์ˆ  ๋ฌธ์„œ(KB) ๋ฉ”์‹œ์ง€๋ฅผ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.
๋…ธํŠธ: Compellent ์Šคํ† ๋ฆฌ์ง€ ์–ด๋ ˆ์ด, PowerVault MD ์Šคํ† ๋ฆฌ์ง€ ์–ด๋ ˆ์ด ๋ฐ Dell
EMC Networking์— ๋Œ€ํ•œ KB ์ •๋ณด๋Š” ์ œ๊ณต๋˜์ง€ ์•Š์Šต๋‹ˆ๋‹ค.
์žฅ์น˜ ํŠน์ • ์ฝ˜์†” ์‹คํ–‰
๊ฐ Dell EMC ์ผ๋Œ€์ผ ์ฝ˜์†”์„ ์‹คํ–‰ํ•˜์—ฌ ์ง€์›๋˜๋Š” Dell EMC ์žฅ์น˜์˜ ์ถ”๊ฐ€ ๋ฌธ์ œ ํ•ด๊ฒฐ ๋ฐ ๊ด€
๋ฆฌ๋ฅผ ์ˆ˜ํ–‰ํ•ฉ๋‹ˆ๋‹ค. ์ž์„ธํ•œ ๋‚ด์šฉ์€ Dell EMC ์žฅ์น˜ ํŠน์ • ์ฝ˜์†” ์‹คํ–‰์„ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.
๋ณด์ฆ ์ •๋ณด ์ง€์›๋˜๋Š” Dell EMC ์žฅ์น˜์— ๋Œ€ํ•œ ๋ณด์ฆ ์ •๋ณด๋ฅผ ์ฃผ๊ธฐ์ ์œผ๋กœ ๋ชจ๋‹ˆํ„ฐ๋งํ•˜๊ณ  ํ‘œ์‹œํ•˜๋ฉฐ ์ƒํƒœ
๋ฅผ Nagios Core ์ฝ˜์†”์— ํ‘œ์‹œํ•ฉ๋‹ˆ๋‹ค. ์ž์„ธํ•œ ๋‚ด์šฉ์€ Dell EMC ์žฅ์น˜์— ๋Œ€ํ•œ ๋ณด์ฆ ์ •๋ณด๋ฅผ
์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.
3
8 ์ฃผ์š” ํŠน์ง•
Support matrix
Dell EMC OpenManage Plug-in version 3.0 for Nagios Core supports the Dell EMC devices as listed in the following tables.
Datacenter Scalable Solutions
Table 3. Supported Datacenter Scalable Solutions.
Datacenter Scalable Solutions (DSS)
DSS 1500
DSS 1510
DSS 2500
Hyper-converged Infrastructure (HCI) Platforms
Table 4. Supported HCI Platforms
VxRail Devices Nutanix XC Devices
VxRail E460 XC6320-6
VxRail E460F XC430-4 Xpress
VxRail P470 XC430-4
VxRail P470F XC630-10
VxRail V470 XC730xd-24
VxRail V470F XC640-10
VxRail S470 XC740-12
XC740-12C
XC740-12R
XC740-24
XC640-4
XC6420-6
XC-940-24
XC640-4 Xpress
XC730-16G
XC730xd-12
XC730xd-12C
XC730xd-12R
4
Support matrix 9
PowerEdge Servers
Table 5. Supported PowerEdge Servers.
12th generation of PowerEdge servers 13th generation of PowerEdge servers 14th generation of PowerEdge servers
FM120x4 C4130 R640
M420 C6320 R740
M520 FC430 R740xd
M620 FC630 R940
M820 FC830 C6420
R220 M630 M640
R320 M830 FC640
R420 R230 R440
R520 R330 R540
R620 R430 T440
R720xd R530 T640
R820 R530xd R6415
R920 R630 R7415
T320 R730 R7425
T420 R730xd
T620 R830
R720 R930
C6320p T130
T330
T430
T630
PowerEdge Chassis
Table 6. Supported PowerEdge chassis.
PowerEdge FX2
PowerEdge FX2s
PowerEdge VRTX
PowerEdge M1000e
10 Support matrix
Compellent SC-Series Storage Arrays
Table 7. Supported Compellent Storage Arrays.
Compellent Series 40
Compellent SC4020
Compellent SC5020
Compellent SC7020
Compellent SC8000
Compellent SC9000
EqualLogic PS-Series Storage Arrays
Table 8. Supported EqualLogic PS-Series Storage Arrays.
EqualLogic PS4000 EqualLogic PS6000
EqualLogic PS4110 EqualLogic PS6010
EqualLogic PS-M4110 EqualLogic PS6110
EqualLogic PS4210 EqualLogic PS6610
EqualLogic PS4100 EqualLogic PS6100
EqualLogic PSM4110 EqualLogic PS6210
EqualLogic PS6500
EqualLogic PS6510
PowerVault MD-Series Storage Arrays
Table 9. Supported PowerVault MD-Series Storage Arrays.
PowerVault MD3400
PowerVault MD3420
PowerVault MD3460
PowerVault MD3800f
PowerVault MD3800i
PowerVault MD3820f
PowerVault MD3820i
PowerVault MD3860f
PowerVault MD3860i
Support matrix 11
Dell EMC Network Switches
Table 10. Supported Network Switches
S Series Z Series C Series FN Series M Series N Series
S3124 Z9100-ON C9010 PowerEdge FN2210S PowerEdge M I/O
Aggregator
N1124T N4064F
S3124P PowerEdge FN410S Power Edge MXL
10/40GbE
N1124P N4064
S3124F PowerEdge FN410T N1148T N3024
S3148 PowerEdge FN340Q N1148P N3024F
S3148F N1108T N3024P
S3048 N1108P N3048
S4048 N1524 N3048P
S4048-ON N1524P N4032
S5000 N1548 N4032F
S6000 N1548P
S6000-ON N2024
S6010-ON N2024P
S6100-ON N2048
S5048F N2048P
NOTE: All the information of the discovered Dell EMC Network Switch will not be displayed if the ๎‚€rmware version is less than
9.11.2.8. You need to ensure that the ๎‚€rmware version is 9.11.2.8 or above.
12
Support matrix
์žฅ์น˜ ๊ฒ€์ƒ‰ ๋ฐ ์ธ๋ฒคํ† ๋ฆฌ
์ฃผ์ œ:
โ€ข About device discovery
โ€ข About Dell EMC device discovery utility
โ€ข Dell EMC ์žฅ์น˜ ๊ฒ€์ƒ‰
โ€ข ์žฅ์น˜ ์ •๋ณด
About device discovery
You can discover the supported Dell EMC devices with this plug-in in the Nagios Core console. The monitoring protocols for the supported
Dell EMC devices are as follows:
โ€ข Dell EMC Servers are discovered using SNMP or WSMan protocol or Red๎‚€sh REST APIs.
โ€ข Dell EMC Chassis are discovered using WSMan protocol.
โ€ข Dell EMC Storage and Dell EMC Network Switches are discovered using SNMP protocol.
NOTE: For discovery using Red๎‚€sh REST APIs, iDRAC ๎‚€rmware version should be 2.50.50.50 or above.
NOTE: For Dell EMC server discovered through Red๎‚€sh, if the iDRAC ๎‚€rmware version is 2.50.50.50, the attribute values of
OSName, OSVersion, ChassisServiceTag, GroupManager and GroupStatus will be shown as Not available
You must use Dell EMC Discovery Utility to discover Dell EMC devices. If the discovery is successful, then for the discovered devices,
host and service de๎‚€nition ๎‚€les are created. For a device, it is recommended to have a unique host name and IP address. In Nagios Core,
ensure that a host and service de๎‚€nition is not already present for a Dell EMC device that you want to discover.
You can discover devices using any of the following:
โ€ข Device IP address or FQDN
โ€ข Subnet with Mask
โ€ข File Containing a list of device IP addresses or FQDNs or Subnet with Mask
โ€ข
NOTE: At a time you can discover a Dell EMC Server using SNMP or WSMan protocol or Red๎‚€sh REST APIs. To rediscover a
server previously discovered through SNMP protocol with WSMan protocol or Red๎‚€sh REST APIs or vice versa, run the Dell
EMC Discovery Utility option along with the value of the desired protocol.
NOTE: If a server was discovered using SNMP, but you want to discover the same device using WSMan protocol, navigate to
<NAGIOS_HOME>/dell/scripts, and run the following Python commands:
For example:
To discover a SNMP device through WSMan Protocol using Host name details:
python dellemc_nagios_discovery_service_utility.py --host=<host name / IP address> --
prefProtocol=2 --http.user=root --http.password=calvin --output.file=/usr/local/nagios/
dell/config/objects/
<NAGIOS_HOME> is the installed location of Nagios Core and by default, the location of <NAGIOS_HOME> is /usr/local/nagios.
5
์žฅ์น˜ ๊ฒ€์ƒ‰ ๋ฐ ์ธ๋ฒคํ† ๋ฆฌ 13
About Dell EMC device discovery utility
To run the Dell Device Discovery Utility, navigate to <NAGIOS_HOME>/dell/scripts, and run the following Python command:
python dellemc_nagios_discovery_service_utility.py -h
All the available Dell EMC device discovery utility options are displayed.
Table 11. Dell EMC Device Helper Utility options
Options Description
-h
Displays the help message.
--host
Host IP address or HostName to be discovered.
--File
Provides a ๎‚€lename with path containing the IP addresses / Hostname /
Subnet with mask, separated by new line.
--subnet
To get the Subnet with mask.
--all
This option is used to display detailed services.
If --all parameter is added, the result displays all the detailed services. By
default, only basic services are displayed.
--prefProtocol
PrefProtocol used for monitoring. Allowed options are 1 (SNMP), 2 (WSMan)
and 3 (Red๎‚€sh). This value is optional.
NOTE: This parameter is applicable only for Dell EMC servers. By
default, Server will be discovered using WSMan Protocol if the
WSMan parameters are passed. Else the discovery will happen
through SNMP if SNMP parameters are passed.
--output.file
This displays the location where the host ๎‚€le will be created in .cfg format.
--logLoc
This parameter takes the log location from the user.
NOTE: If this attribute is not passed, the logs will be created in the
default location /<NAGIOS_HOME>/var/dell
--snmp.version
Version of SNMP protocol. Allowed options are 1(SNMP v1), 2(SNMP v2c)
--snmp.community
Community string for SNMP communication. Default value is Public.
--snmp.port
For SNMP port value. Allowed value is [1-65535]. Default value is 161.
--snmp.retries
For SNMP retries count. Allowed value is [1-10]. Default value is 1.
--snmp.timeout
SNMP timeout values (in seconds). Allowed values is [1-1440]. Default value is
3.
--http.user
WSMan / REST authentication username.
--http.password
WSMan / REST authentication password.
--http.timeout
WSMan / REST timeout (in seconds). Allowed value is [1-1440]. Default value is
30.
--http.retries
WSMan / REST retries count. Allowed value is [1-10]. Default value is 1.
--http.port
WSMan / REST port details. Allowed value is [1-65535]. Default value is 443.
--enableLog
To enable or disable the logs.
If --enable parameter is passed, the logs are created else the logs are not
created.
14 ์žฅ์น˜ ๊ฒ€์ƒ‰ ๋ฐ ์ธ๋ฒคํ† ๋ฆฌ
Options Description
--force
--force rewrites the con๎‚€g ๎‚€le.
--warranty.criticalDays
Warranty critical days. Allowed value is [1-365]. Default value is 10.
NOTE: The value of Warranty critical days should be less than
Warranty warning days.
--warranty.warningDays
Warranty warning days. Allowed value is [1-365]. Default value is 30.
--nagios.type
Decides the output format of the host ๎‚€le. Allowed options is 0 for .cfg format
and 1 for .xml format.
Default values is 0.
Table 12. Dell EMC Device Helper Utility Mandatory Parameters
--host
These parameters de๎‚€ne the value of the Dell EMC device to be
discovered.
--filename
--subnet
--snmp.version
This parameter is mandatory for a Dell EMC device discovered
through SNMP.
--http.user
This parameter is mandatory for a Dell EMC device discovered
through WSMan / Red๎‚€sh.
--http.password
--output.file
This displays the location where the host ๎‚€le will be created
in .cfg format
Based on the options you selected during discovery, the following services are associated with that host:
โ€ข If you run the Python command python dellemc_nagios_discovery_service_utility.py without the --all option,
then only the basic services are created by default and displayed in the user interface under Services.
NOTE: SNMPTT must be con๎‚€gured for you to be able to receive
traps.
โ€ข If you run python dellemc_nagios_discovery_service_utility.py with the --all option, detailed services are created
as listed in the table below, and are displayed in the Nagios Core console under Services:
Table 13. Default services created for Dell EMC Servers based on the selected protocol
Services SNMP WSMan Protocol Red๎‚€sh Protocol
Basic Services
Dell EMC Server Overall Health
Status
โˆš โˆš โˆš
Dell EMC Server Information โˆš โˆš โˆš
Dell EMC Server Traps โˆš โˆš โˆš
Detailed Services
Dell EMC Memory Status โˆš โˆš X
์žฅ์น˜ ๊ฒ€์ƒ‰ ๋ฐ ์ธ๋ฒคํ† ๋ฆฌ 15
Services SNMP WSMan Protocol Red๎‚€sh Protocol
Dell EMC Server Physical Disk
Status โˆš โˆš X
Dell EMC Server Virtual Disk
Status โˆš โˆš X
Dell EMC Server Fan Status โˆš โˆš โˆš
Dell EMC Server Battery Status โˆš โˆš X
Dell EMC Server Intrusion Status โˆš โˆš X
Dell EMC Server Network Device
Status
โˆš โˆš โˆš
Dell EMC Server Voltage Probe
Status
โˆš โˆš โˆš
Dell EMC Server Controller Status โˆš โˆš โˆš
Dell EMC Server Amperage Probe
Status
โˆš โˆš X
Dell EMC Server CPU Status โˆš โˆš โˆš
Dell EMC Server Power Supply
Status
โˆš โˆš โˆš
Dell EMC Server Temperature
Probe Status
โˆš โˆš โˆš
Dell EMC Server SD Card Status X โˆš X
Dell EMC Server FC NIC Status X โˆš X
Dell EMC Server Warranty
Information
โˆš โˆš โˆš
Table 14. Default services created for all Dell EMC Chassis based on WSMan protocol
Services
Basic Services
Dell EMC Chassis Overall Health Status
Dell EMC Chassis Information
Dell EMC Chassis Traps
Detailed Services
Dell EMC Chassis Fan Status
Dell EMC Chassis Server Slot Information
Dell EMC Chassis Storage Slot Information
Dell EMC Chassis I/O Module Status
Dell EMC Chassis Power Supply Status
Dell EMC Chassis KVM Status
Dell EMC Chassis Warranty Information
Dell EMC Chassis Enclosure Status (This service is applicable to PowerEdge VRTX Chassis only)
Dell EMC Chassis Controller Status (This service is applicable to PowerEdge VRTX Chassis only)
Dell EMC Chassis Physical Disk Status (This service is applicable to PowerEdge VRTX Chassis only)
Dell EMC Chassis Virtual Disk Status (This service is applicable to PowerEdge VRTX Chassis only)
16 ์žฅ์น˜ ๊ฒ€์ƒ‰ ๋ฐ ์ธ๋ฒคํ† ๋ฆฌ
Services
Dell EMC Chassis PCIe Devices Status (This service is applicable to PowerEdge VRTX Chassis and PowerEdge FX2/FX2s Chassis
only)
Table 15. Default services created for all Dell EMC Networking based on SNMP protocol
Basic Services
Dell EMC Network Switch Information
Dell EMC Network Switch Overall Health Status
Dell EMC Network Switch Traps
Detailed Services
Dell EMC Network Switch PowerSupply Status
Dell EMC Network Switch PowerSupplyTray Status
Dell EMC Network Switch Fan Status
Dell EMC Network FanTray Status
Dell EMC Network Switch Processor Status
Dell EMC Network Switch vFlash Status
Dell EMC Network Switch Physical Port Status
Dell EMC Network Switch Warranty Information
NOTE: For M-Series and F-Series Dell EMC Network Switch, Dell EMC Network Switch PowerSupply Status, Dell EMC
Network Switch PowerSupplyTray Status, Dell EMC Switch Network FanTray Status, Dell EMC Network Switch Fan Status
services are not applicable.
Table 16. Default services created for Compellent SC-Series Storage Arrays based on SNMP protocol
Services
Basic Services
Dell EMC Storage SC-Series Overall Health Status
Dell EMC Storage SC-Series Information
Dell EMC Storage SC-Series Management Traps
Dell EMC Storage SC-Series Controller Traps
Dell EMC Storage SC-Series Controller Overall Health Status
Dell EMC Storage SC-Series Controller Information
Detailed Services
Dell EMC Storage SC-Series Physical Disk Status
Dell EMC Storage SC-Series Volume Status
Dell EMC Storage SC-Series Controller Warranty Information
Table 17. Default services created for EqualLogic PS-Series Storage Arrays based on SNMP protocol
Services
Basic Services
Dell EMC Storage PS-Series Member Overall Health Status
Dell EMC Storage PS-Series Member Information
์žฅ์น˜ ๊ฒ€์ƒ‰ ๋ฐ ์ธ๋ฒคํ† ๋ฆฌ 17
Services
Basic Services
Dell EMC Storage PS-Series Group Information
Dell EMC Storage PS-Series Member Traps
Dell EMC Storage PS-Series Member Group Traps
Detailed Services
Dell EMC Storage PS-Series Member Physical Disk Status
Dell EMC Storage PS-Series Group Volume Status
Dell EMC Storage PS-Series Group Storage Pool Status
Dell EMC Storage PS-Series Group Storage Pool Information
Dell EMC Storage PS-Series Member Warranty Information
Table 18. Default services created for PowerVault MD-Series Storage Arrays based on SNMP protocol
Services
Basic Services
Dell EMC Storage MD-Series MD Overall Health Status
Dell EMC Storage MD-Series MD Information
Dell EMC Storage MD-Series MD Traps
Detailed Services
Dell EMC Storage MD-Series Warranty Information
Dell EMC ์žฅ์น˜ ๊ฒ€์ƒ‰
์ด ํ”Œ๋Ÿฌ๊ทธ์ธ์„ ์‚ฌ์šฉํ•˜์—ฌ ์ง€์›๋˜๋Š” ๋ชจ๋“  Dell EMC ์žฅ์น˜๋ฅผ ๊ฒ€์ƒ‰ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.
์‚ฌ์ „ ๊ตฌ์„ฑ ์š”์†Œ:
โ€ข ๊ฒ€์ƒ‰์— SNMP ํ”„๋กœํ† ์ฝœ์„ ์‚ฌ์šฉํ•˜๋Š” ๊ฒฝ์šฐ, SNMP ๋ฒ„์ „ 1 ๋˜๋Š” SNMP ๋ฒ„์ „ 2๊ฐ€ ํ™œ์„ฑํ™”๋˜์–ด ์žˆ๊ณ , Dell EMC ์„œ๋ฒ„ ๋˜๋Š” Dell EMC ์Šคํ† 
๋ฆฌ์ง€ ์žฅ์น˜ ๋ฐ Dell EMC ๋„คํŠธ์›Œํฌ ์Šค์œ„์น˜์˜ ์ปค๋ฎค๋‹ˆํ‹ฐ ๋ฌธ์ž์—ด์ด ์„ค์ • ๋ฐ ๊ตฌ์„ฑ๋˜์–ด ์žˆ๋Š”์ง€ ํ™•์ธํ•˜์‹ญ์‹œ์˜ค. ์ž์„ธํ•œ ๋‚ด์šฉ์€ ๋ถ€๋ก์„ ์ฐธ์กฐ
ํ•˜์‹ญ์‹œ์˜ค.
โ€ข Nagios Core ๋ฐ ์žฅ์น˜ ์‚ฌ์ด์— ๋ณด์•ˆ ๋„คํŠธ์›Œํฌ ์—ฐ๊ฒฐ์ด ์„ค์ •๋ฉ๋‹ˆ๋‹ค.
โ€ข ์žฅ์น˜์— ํ™•์ธ ๊ฐ€๋Šฅํ•œ FQDN์ด ์žˆ๋Š” ๊ฒƒ์ด ์ข‹์Šต๋‹ˆ๋‹ค.
โ€ข Dell EMC ์„€์‹œ ์žฅ์น˜ ๊ฒ€์ƒ‰์„ ์œ„ํ•ด WSMan์ด ํ™œ์„ฑํ™”๋˜๊ณ  ๊ตฌ์„ฑ๋˜์–ด ์žˆ์Šต๋‹ˆ๋‹ค.
โ€ข WSMan์€ WSMan ํ”„๋กœํ† ์ฝœ์„ ์‚ฌ์šฉํ•˜์—ฌ Dell EMC ์„œ๋ฒ„๋ฅผ ๊ฒ€์ƒ‰ํ•  ์ˆ˜ ์žˆ๋„๋ก ์„ค์ • ๋ฐ ๊ตฌ์„ฑ๋˜์–ด ์žˆ์Šต๋‹ˆ๋‹ค.
โ€ข Red๎‚€sh๋Š” Red๎‚€sh REST API๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ Dell EMC ์„œ๋ฒ„๋ฅผ ๊ฒ€์ƒ‰ํ•  ์ˆ˜ ์žˆ๋„๋ก ์„ค์ • ๋ฐ ๊ตฌ์„ฑ๋˜์–ด ์žˆ์Šต๋‹ˆ๋‹ค.
Dell EMC ์žฅ์น˜๋ฅผ ๊ฒ€์ƒ‰ํ•˜๋ ค๋ฉด ๋‹ค์Œ์„ ์ˆ˜ํ–‰ํ•˜์‹ญ์‹œ์˜ค.
1 Nagios ๊ด€๋ฆฌ์ž ๊ถŒํ•œ์„ ์‚ฌ์šฉํ•˜์—ฌ Nagios Core์— ๋กœ๊ทธ์ธํ•ฉ๋‹ˆ๋‹ค.
2 <NAGIOS_HOME>/dell/scripts ๋””๋ ‰ํ„ฐ๋ฆฌ๋กœ ์ด๋™ํ•ฉ๋‹ˆ๋‹ค.
3 ๋‹ค์Œ ์˜ต์…˜์œผ๋กœ Dell ์žฅ์น˜ ๊ฒ€์ƒ‰ ์œ ํ‹ธ๋ฆฌํ‹ฐ๋ฅผ ์‹คํ–‰ํ•ฉ๋‹ˆ๋‹ค. python dellemc_nagios_discovery_service_utility.py
์Šคํฌ๋ฆฝํŠธ ๊ตฌ๋ฌธ ๋ฐ ์˜ต์…˜์— ๋Œ€ํ•œ ์ •๋ณด๊ฐ€ ํ‘œ์‹œ๋ฉ๋‹ˆ๋‹ค. ์ž์„ธํ•œ ๋‚ด์šฉ์€ Dell ๊ฒ€์ƒ‰ ์œ ํ‹ธ๋ฆฌํ‹ฐ ์ •๋ณด๋ฅผ ์ฐธ์กฐํ•˜์‹ญ์‹œ์˜ค.
18 ์žฅ์น˜ ๊ฒ€์ƒ‰ ๋ฐ ์ธ๋ฒคํ† ๋ฆฌ
์š”๊ตฌ์‚ฌํ•ญ์— ๋”ฐ๋ผ ๋‹ค์Œ๊ณผ ๊ฐ™์ด ํ•˜์‹ญ์‹œ์˜ค.
โ€ข ํ˜ธ์ŠคํŠธ IP ์ฃผ์†Œ๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ SNMP ์žฅ์น˜๋ฅผ ๊ฒ€์ƒ‰ํ•˜๋ ค๋ฉด ๋‹ค์Œ์„ ์ˆ˜ํ–‰ํ•˜์‹ญ์‹œ์˜ค.
python dellemc_nagios_discovery_utility.py --host=<host name or IP address> --
snmp.version=2 --output.file=/usr/local/nagios/dell/config/objects/
โ€ข Filepath๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ WSMan ํ”„๋กœํ† ์ฝœ/Red๎‚€sh REST API๋ฅผ ํ†ตํ•ด ๊ฒ€์ƒ‰ํ•˜๋ ค๋ฉด ๋‹ค์Œ์„ ์ˆ˜ํ–‰ํ•˜์‹ญ์‹œ์˜ค.
python dellemc_nagios_discovery_utility.py --file=<absolute file path> --http.user=root --
http.password=calvin --output.file=/usr/local/nagios/dell/config/objects/
โ€ข ์„œ๋ธŒ๋„ท ๋งˆ์Šคํฌ๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ SNMP ๋˜๋Š” WSMan ํ”„๋กœํ† ์ฝœ/Red๎‚€sh REST API๋ฅผ ํ†ตํ•ด ๊ฒ€์ƒ‰ํ•˜๋ ค๋ฉด ๋‹ค์Œ์„ ์ˆ˜ํ–‰ํ•˜์‹ญ์‹œ์˜ค.
python dellemc_nagios_discovery_utility.py --subnet=<subnet with mask> --snmp.version=2 --
http.user=root --http.password=calvin --output.file=/usr/local/nagios/dell/config/objects/
๋…ธํŠธ: ๋‹ค๋ฅธ Dell EMC ๊ฒ€์ƒ‰ ์œ ํ‹ธ๋ฆฌํ‹ฐ ๋งค๊ฐœ๋ณ€์ˆ˜๊ฐ€ ์ „๋‹ฌ๋˜์ง€ ์•Š์œผ๋ฉด ๋ช…๋ น์ด ๊ธฐ๋ณธ๊ฐ’์œผ๋กœ ์‹คํ–‰๋ฉ๋‹ˆ๋‹ค.
๋…ธํŠธ: IP ์ฃผ์†Œ ๋˜๋Š” FQDN์„ ์‚ฌ์šฉํ•˜์—ฌ Dell EMC ์žฅ์น˜๊ฐ€ ๊ฒ€์ƒ‰๋˜๊ณ  ์ง€์ •๋œ ์ธ์Šคํ„ด์Šค์—์„œ ๋‘˜ ๋‹ค ๊ฒ€์ƒ‰๋˜์ง€ ์•Š๋Š”์ง€ ํ™•์ธํ•˜์‹ญ์‹œ
์˜ค.
4 ๊ธฐ๋ณธ์ ์œผ๋กœ Dell EMC ์„œ๋ฒ„๋Š” WSMan ํ”„๋กœํ† ์ฝœ์„ ์‚ฌ์šฉํ•˜์—ฌ ๊ฒ€์ƒ‰๋ฉ๋‹ˆ๋‹ค. WSMan ํ”„๋กœํ† ์ฝœ ๋งค๊ฐœ๋ณ€์ˆ˜๊ฐ€ ๋ช…๋ น์— ์ „๋‹ฌ๋˜์ง€ ์•Š์œผ๋ฉด
SNMP๋ฅผ ํ†ตํ•ด ๊ฒ€์ƒ‰์ด ์ˆ˜ํ–‰๋ฉ๋‹ˆ๋‹ค. ์š”๊ตฌ ์‚ฌํ•ญ์— ๋”ฐ๋ผ --prefProtocol ๊ฐ’์„ ๋ณ€๊ฒฝํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.
Dell EMC ์„œ๋ฒ„๋Š” ๋‹ค์Œ ๋ช…๋ น์„ ์‚ฌ์šฉํ•˜์—ฌ WSMan ๋˜๋Š” Red๎‚€sh ๋˜๋Š” SNMP๋ฅผ ํ†ตํ•ด ๊ฒ€์ƒ‰ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.
โ€ข ํŒŒ์ผ ๊ฒฝ๋กœ๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ WSMan ํ”„๋กœํ† ์ฝœ์„ ํ†ตํ•ด ๊ฒ€์ƒ‰ํ•˜๋ ค๋ฉด ๋‹ค์Œ์„ ์ˆ˜ํ–‰ํ•˜์‹ญ์‹œ์˜ค.
python dellemc_nagios_discovery_utility.py --file=<absolute file path> --prefProtocol=2 --
http.user=root --http.password=calvin --output.file=/usr/local/nagios/dell/config/objects/
โ€ข ํŒŒ์ผ ๊ฒฝ๋กœ๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ Red๎‚€sh REST API๋ฅผ ํ†ตํ•ด ๊ฒ€์ƒ‰ํ•˜๋ ค๋ฉด ๋‹ค์Œ์„ ์ˆ˜ํ–‰ํ•˜์‹ญ์‹œ์˜ค.
python dellemc_nagios_discovery_utility.py --file=<absolute file path> --prefProtocol=3 --
http.user=root --http.password=calvin --output.file=/usr/local/nagios/dell/config/objects/
โ€ข ํŒŒ์ผ ๊ฒฝ๋กœ๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ SNMP๋ฅผ ํ†ตํ•ด ๊ฒ€์ƒ‰ํ•˜๋ ค๋ฉด ๋‹ค์Œ์„ ์ˆ˜ํ–‰ํ•˜์‹ญ์‹œ์˜ค.
python dellemc_nagios_discovery_utility.py --file=<absolute file path> --prefProtocol=1 --
snmp.version=2 --output.file=/usr/local/nagios/dell/config/objects/
5 ๊ฒ€์ƒ‰ ์œ ํ‹ธ๋ฆฌํ‹ฐ ์Šคํฌ๋ฆฝํŠธ๊ฐ€ ์‹คํ–‰๋˜๋ฉด ๋‹ค์Œ ๋ช…๋ น์„ ์‹คํ–‰ํ•˜์—ฌ Nagios ๊ตฌ์„ฑ์„ ํ™•์ธํ•ฉ๋‹ˆ๋‹ค. <NAGIOS_HOME>/bin/nagios -v /
<NAGIOS_HOME>/etc/nagios.cfg
.
๋…ธํŠธ: --enable.log ๋งค๊ฐœ๋ณ€์ˆ˜๊ฐ€ ์ „๋‹ฌ๋˜์ง€ ์•Š์œผ๋ฉด ๋กœ๊ทธ๊ฐ€ ์ž‘์„ฑ๋˜์ง€ ์•Š์Šต๋‹ˆ๋‹ค.
๋…ธํŠธ: --enable.log ๋งค๊ฐœ๋ณ€์ˆ˜๊ฐ€ ์ „๋‹ฌ๋˜์—ˆ์ง€๋งŒ --logLoc ๊ฐ’์ด ์ •์˜๋˜์ง€ ์•Š์€ ๊ฒฝ์šฐ ๋กœ๊ทธ๋Š” ๊ธฐ๋ณธ ์œ„์น˜ <NAGIOS_HOME>/var/
dell์— ์ƒ์„ฑ๋ฉ๋‹ˆ๋‹ค.
6 ์˜ค๋ฅ˜๊ฐ€ ์—†์Œ์„ ํ™•์ธํ•œ ํ›„ service nagios restart ๋ช…๋ น์„ ์‹คํ–‰ํ•˜์—ฌ Nagios Core๋ฅผ ๋‹ค์‹œ ์‹œ์ž‘ํ•ฉ๋‹ˆ๋‹ค.
๊ฒ€์ƒ‰ ์™„๋ฃŒ ํ›„:
โ€ข Nagios ์„œ๋ฒ„์— Dell EMC ์žฅ์น˜ ํ˜ธ์ŠคํŠธ ์ •์˜ ๋ฐ ํ•ด๋‹น ์„œ๋น„์Šค ์ •์˜๊ฐ€ ์ƒ์„ฑ๋˜๋ฉฐ ์ด ์ •์˜๋Š” ์ดํ›„์— Dell EMC ์žฅ์น˜ ๋ชจ๋‹ˆํ„ฐ๋ง์— ์‚ฌ์šฉ๋ฉ๋‹ˆ
๋‹ค.
๊ฒ€์ƒ‰๋œ Dell EMC ์žฅ์น˜์™€ ํ•ด๋‹น ์„œ๋น„์Šค๊ฐ€ Nagios Core ์ฝ˜์†”์˜ ํ˜ธ์ŠคํŠธ ๋ณด๊ธฐ์™€ ์„œ๋น„์Šค ๋ณด๊ธฐ์— ํ‘œ์‹œ๋ฉ๋‹ˆ๋‹ค. ์˜ˆ์•ฝ๋œ ์„œ๋น„์Šค๊ฐ€ ์™„๋ฃŒ๋  ๋•Œ
๊นŒ์ง€ ๊ธฐ๋‹ค๋ ค์•ผ ์„œ๋น„์Šค ์„ธ๋ถ€์ •๋ณด๊ฐ€ ํ‘œ์‹œ๋ฉ๋‹ˆ๋‹ค.
โ€ข ๊ฒ€์ƒ‰๋œ Dell EMC ์žฅ์น˜๊ฐ€ Nagios Core ์ฝ˜์†”์˜ ๋งต ๋ณด๊ธฐ์— ํ‘œ์‹œ๋ฉ๋‹ˆ๋‹ค.
์žฅ์น˜ ์ •๋ณด
์žฅ์น˜ ์ •๋ณด
Dell EMC ์žฅ์น˜ ์ •๋ณด ์„œ๋น„์Šค๋Š” ์‹œ์Šคํ…œ์— ๋Œ€ํ•œ ๊ธฐ๋ณธ ์ •๋ณด๋ฅผ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค. ๊ธฐ๋ณธ์ ์œผ๋กœ ์ด ์„œ๋น„์Šค๋Š” ํ•˜๋ฃจ์— ํ•œ ๋ฒˆ ํด๋ง๋ฉ๋‹ˆ๋‹ค.
์žฅ์น˜ ๊ฒ€์ƒ‰ ๋ฐ ์ธ๋ฒคํ† ๋ฆฌ 19
ํ‘œ 19. ์žฅ์น˜ ์ •๋ณด
์„œ๋น„์Šค ์ƒํƒœ ์„ค๋ช… ํ‘œ์‹œ๋˜๋Š” ํŠน์„ฑ
Dell EMC ์„œ๋ฒ„ ์ •๋ณด ๋‹ค์Œ ์ƒํƒœ๊ฐ€ ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.
โ€ข ํ™•์ธ
โ€ข ์•Œ ์ˆ˜ ์—†์Œ
โ€ข ์œ„ํ—˜
โ€ข ๊ฒฝ๊ณ 
์ด ์„œ๋น„์Šค๋Š” ๊ธฐ๋ณธ ์žฅ์น˜ ์ธ๋ฒคํ† 
๋ฆฌ ์ •๋ณด๋ฅผ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค.
๋…ธํŠธ: ์„€์‹œ ํƒœ๊ทธ๋Š” ๋ชจ๋“ˆ๋Ÿฌ
์„œ๋ฒ„์—๋งŒ ํ•ด๋‹น๋˜๊ณ , ๋…ธ๋“œ
ID๋Š” PowerEdge
FM120x4์—๋งŒ ํ•ด๋‹น๋ฉ๋‹ˆ
๋‹ค.
๋…ธํŠธ: ์‹œ์Šคํ…œ ๊ตฌ์„ฑ ์ž ๊ธˆ
๋ชจ๋“œ, iDRAC ๊ทธ๋ฃน ๊ด€๋ฆฌ์ž
์ƒํƒœ ๋ฐ iDRAC ๊ทธ๋ฃน ์ด๋ฆ„
์€ 14G ์„œ๋ฒ„์—๋งŒ ์ ์šฉ๋ฉ
๋‹ˆ๋‹ค
โ€ข ๋…ธ๋“œ ID
โ€ข ์„€์‹œ ์„œ๋น„์Šค ํƒœ๊ทธ
โ€ข ์‹œ์Šคํ…œ ์„ธ๋Œ€
โ€ข ์„œ๋น„์Šค ํƒœ๊ทธ
โ€ข ๋ชจ๋ธ
โ€ข OS ์ด๋ฆ„
โ€ข OS ๋ฒ„์ „
โ€ข iDRAC URL
โ€ข iDRAC ํŽŒ์›จ์–ด ๋ฒ„์ „
โ€ข ์„œ๋น„์Šค ํ˜ธ์ŠคํŠธ FQDN
โ€ข VMM URL
โ€ข ์‹œ์Šคํ…œ ๊ตฌ์„ฑ ์ž ๊ธˆ ๋ชจ๋“œ
โ€ข iDRAC ๊ทธ๋ฃน ์ด๋ฆ„
โ€ข iDRAC ๊ทธ๋ฃน ๊ด€๋ฆฌ์ž ์ƒํƒœ
Dell EMC ์„€์‹œ ์ •๋ณด ๋‹ค์Œ ์ƒํƒœ๊ฐ€ ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.
โ€ข ํ™•์ธ
โ€ข ์•Œ ์ˆ˜ ์—†์Œ
โ€ข ์œ„ํ—˜
โ€ข ๊ฒฝ๊ณ 
์ด ์„œ๋น„์Šค๋Š” PowerEdge
M1000e, PowerEdge VRTX,
PowerEdge FX2/FX2s ์„€์‹œ์—
๋Œ€ํ•œ ๊ธฐ๋ณธ ์žฅ์น˜ ์ธ๋ฒคํ† ๋ฆฌ ์ •๋ณด
๋ฅผ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค.
โ€ข ์„œ๋น„์Šค ํƒœ๊ทธ
โ€ข ์„€์‹œ ์ด๋ฆ„
โ€ข ๋ชจ๋ธ ์ด๋ฆ„
โ€ข CMC ํŽŒ์›จ์–ด ๋ฒ„์ „
โ€ข CMC URL
Dell EMC Storage SC-Series ์ปจ
ํŠธ๋กค๋Ÿฌ ์ •๋ณด
๋‹ค์Œ ์ƒํƒœ๊ฐ€ ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.
โ€ข ํ™•์ธ
โ€ข ์•Œ ์ˆ˜ ์—†์Œ
โ€ข ์œ„ํ—˜
โ€ข ๊ฒฝ๊ณ 
์ด ์„œ๋น„์Šค๋Š” Compellent ์ปจํŠธ๋กค
๋Ÿฌ IP์— ๋Œ€ํ•œ ๊ธฐ๋ณธ ์žฅ์น˜ ์ธ๋ฒคํ† 
๋ฆฌ ์ •๋ณด๋ฅผ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค.
โ€ข ์ „์ฒด ์ปจํŠธ๋กค๋Ÿฌ
โ€ข ์„œ๋น„์Šค ํƒœ๊ทธ
โ€ข ๊ธฐ๋ณธ ์ปจํŠธ๋กค๋Ÿฌ
โ€ข ์ปจํŠธ๋กค๋Ÿฌ ์ด๋ฆ„
โ€ข ๋ชจ๋ธ ์ด๋ฆ„
โ€ข Compellent URL
Dell EMC Storage SC-Series ์ •
๋ณด
๋‹ค์Œ ์ƒํƒœ๊ฐ€ ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.
โ€ข ํ™•์ธ
โ€ข ์•Œ ์ˆ˜ ์—†์Œ
โ€ข ์œ„ํ—˜
โ€ข ๊ฒฝ๊ณ 
์ด ์„œ๋น„์Šค๋Š” Compellent ๊ด€๋ฆฌ IP
์— ๋Œ€ํ•œ ๊ธฐ๋ณธ ์žฅ์น˜ ์ธ๋ฒคํ† ๋ฆฌ ์ •
๋ณด๋ฅผ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค
โ€ข ์ „์ฒด ์Šคํ† ๋ฆฌ์ง€ ์„ผํ„ฐ
โ€ข ํŽŒ์›จ์–ด ๋ฒ„์ „
โ€ข Compellent URL
โ€ข ์Šคํ† ๋ฆฌ์ง€ ์ด๋ฆ„
โ€ข ๊ธฐ๋ณธ ์ปจํŠธ๋กค๋Ÿฌ ์ด๋ฆ„
โ€ข ๊ธฐ๋ณธ ์ปจํŠธ๋กค๋Ÿฌ ๋ชจ๋ธ
โ€ข ๊ธฐ๋ณธ ์ปจํŠธ๋กค๋Ÿฌ IP ์ฃผ์†Œ
โ€ข ๊ธฐ๋ณธ ์ปจํŠธ๋กค๋Ÿฌ ์„œ๋น„์Šค ํƒœ๊ทธ
โ€ข ๋ณด์กฐ ์ปจํŠธ๋กค๋Ÿฌ ์ด๋ฆ„
โ€ข ๋ณด์กฐ ์ปจํŠธ๋กค๋Ÿฌ ๋ชจ๋ธ
โ€ข ๋ณด์กฐ ์ปจํŠธ๋กค๋Ÿฌ IP ์ฃผ์†Œ
โ€ข ๋ณด์กฐ ์ปจํŠธ๋กค๋Ÿฌ ์„œ๋น„์Šค ํƒœ๊ทธ
Dell EMC Storage PS-Series ๊ตฌ
์„ฑ์› ์ •๋ณด
๋‹ค์Œ ์ƒํƒœ๊ฐ€ ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.
โ€ข ํ™•์ธ
โ€ข ์•Œ ์ˆ˜ ์—†์Œ
์ด ์„œ๋น„์Šค๋Š” EqualLogic ๊ตฌ์„ฑ์›
์— ๋Œ€ํ•œ ๊ธฐ๋ณธ ์žฅ์น˜ ์ธ๋ฒคํ† ๋ฆฌ ์ •
๋ณด๋ฅผ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค.
โ€ข ์ „์ฒด ๊ตฌ์„ฑ์›
โ€ข ๊ตฌ์„ฑ์› ์ด๋ฆ„
โ€ข ์ œํ’ˆ๊ตฐ
20 ์žฅ์น˜ ๊ฒ€์ƒ‰ ๋ฐ ์ธ๋ฒคํ† ๋ฆฌ
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46

Dell EMC OpenManage Plug-in v3.0 for Nagios Core User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI