Rust-Oleum RUST-OLEUM ROC-246 790 Synthetic Roof Coating User manual

Type
User manual

This manual is also suitable for

TECHNICAL DATA
ROC-246
RUST-OLEUM® 790
SYNTHETIC ROOF COATING
1
DESCRIPTION AND USES
Rust-Oleum® 790 Synthetic Silicone Roof Coating is a non-
fibered, semi-gloss, water-based acrylic roof coating which is
specially formulated with a flouro-polymer resin. The 790
coating is VOC compliant as a roof coating and is asbestos
free. 790 Coating is used as a semi-gloss finish coat over
water-based acrylic roof and wall coatings and other
approved coatings and substrates as recommended by
Rust-Oleum, such as granule surfaced modified bitumen
membranes. 790 coating provides long term color-fast
performance under constant solar exposure, such as those
conditions found on roofs and exterior building walls. 790
coating also offers superior resistance to dirt pickup.
790 coating has been tested for reflective properties
according to the standards of the Cool Roof Rating Council
(CRRC) and is listed in the CRRC Rated Products Directory.
For use on metal roofs, concrete, modified bitumen, bulit-up,
and weathered single-ply roofing.
PRODUCT FEATURES
Stays white 3X longer than silicone
88% reflectivity
Resists rain & ponding water in 1 hour
Cool Roof technology
700% elasticity, resists cracking
PRODUCTS
SKU
DESCRIPTION (Bright White)
381787
5 Gallon Pail
381788
1 Gallon
PRODUCT APPLICATION
SURFACE PREPARATION
All surfaces must be clean and free from dirt, grease, oil,
loose granule, loose paint, rust, excess chalk, and other
foreign matter, which could prevent proper adhesion. This is
best accomplished using a high pressure wash of at least
2,000 psi. A surface cleaner shall be used to remove all
grease or oily deposits. Remove all dirt, dust, and other loose
debris from the roof. Area to be coated must be a clean,
sound and dry surface.
WARNING! If you scrape, sand or remove old paint from any
surface, you may release lead paint dust. LEAD IS TOXIC.
EXPOSURE TO LEAD DUST CAN CAUSE SERIOUS
ILLNESS, SUCH AS BRAIN DAMAGE; ESPECIALLY IN
CHILDREN. PREGNANT WOMEN SHOULD ALSO AVOID
EXPOSURE. Wear a NIOSH approved respirator to control
lead exposure. Clean up carefully with a HEPA vacuum and
a wet mop. Before you start, find out how to protect yourself
and your family by contacting the National Lead Information
Hotline at 1-800-424-LEAD or log on to www.epa.gov/lead.
PRODUCT APPLICATION (cont.)
APPLICATION
Adhesion test may be required. Consult with your
Rust-Oleum representative.
Mechanical mixing is recommended. Ensure product is
consistent in appearance and viscosity. Avoid entraining air
when mixing. Install product using one of the approved
application methods evenly at the recommended coverage
rate. Use wet mil gauges to monitor coverage rates
throughout application.
Two coats are recommended. Applying the second coat after
the first coat will support foot traffic without tracking. Avoid
foot traffic on final coat for 24 hours. For best results, apply
the second coat in a direction which is perpendicular to the
first coat. For spray application, take necessary precautions
to avoid overspray. 790 can be spray, roll or brush applied. If
rolling, use medium nap polyester. If brushing, use a bristle,
nylon/polyester or nylon. See below for spray equipment
recommendations.
SPRAY EQUIPMENT RECOMMENDATION
Airless Spray: Pneumatic, hydraulic, or electric pump with a
minimum 2,000 psi material output pressure. Reversible
spray tip with a 0.017’’ to 0.025’’ orifice and a 40° to 60°
spray fan. Material spray lines must be properly rated for the
maximum working pressure of the pump being used.
Fan
Width"
0.39
.043
.047
.051
.055
.059
10-12"
539
543
547
555
547
559
12-14"
639
643
647
651
647
659
14-16"
739
743
747
751
747
---
16-18"
839
843
847
851
847
---
Flow
Rate
1.60
gpm
1.98
gpm
2.37
gpm
2.79
gpm
2.37
gpm
3.74
gpm
DRY & RECOAT TIMES
Dry and recoat times are based on 77°F (25°C) and 50%
relative humidity. Dry times increase at cooler temperatures.
Dries to the touch in 6 hours; allow minimum 24 hours
recoat. Environmental or site specific conditions may
require variations in cure times.
COVERAGE
Apply two coats at 0.75 gal./100 square feet (1.6 m2/L) (12
wet mils) per coat for a total application rate of 1.5 gal./100
square feet (3.2 m2/L).
TECHNICAL DATA
ROC-246
RUST-OLEUM® 790
SYNTHETIC ROOF COATING
2
PRODUCT APPLICATION (cont.)
CLEAN-UP
Soap and water. Wipe up splatters before they dry. Follow
equipment manufacturer’s directions to clean spray
equipment.
LIMITATIONS
Surfaces must be clean and free of dirt, dust, and other
contaminants. Not intended for use in ponded areas. Do not
apply unless temperatures are at least 45°F (7°C) and
rising. Do not apply if temperatures are expected to drop
below 45°F (7°C) within 48 hours of application. Do not
apply to wet surfaces. Do not apply unless the ambient and
surface temperatures are at least 5°F (-15°C) above the
dew point. Do not apply when freezing temperatures are
expected within 48 hours after application. Do not apply if
rain is expected within 12 hours. If temperatures drop below
60°F (15°C), do not apply if rain is expected within 24 hours.
Store container at temperatures above 32°F (0°C). Do not
allow container to freeze. Store container indoors in a
heated area. Do not apply over hot applied asphalt or coal
tar pitch flood or glaze coats.
PERFORMANCE CHARACTERISTICS
ELONGATION
METHOD: ASTM D2370
TYPICAL RESULT: 395%
TENSILE STRENGTH
METHOD: ASTM D370
TYPICAL RESULT: 393 psi
ADHESION
METHOD: ASTM D1876
TYPICAL RESULT:
Granulated Cap Sheet (No primer) 5.20 lbf/in
Granulated Cap Sheet (SP Primer) 6.08 lbf/in
Smooth MB (No Primer) 2.73 lbf/in
Smooth MB (SP Primer) 5.59 lbf/in
DENSITY @77°F (25°C)
METHOD: ASTM D1475
TYPICAL RESULT: 9.4 lbs/gal (1.12 kg/L)
GLOSS @ 60°
METHOD: ASTM D523
TYPICAL RESULT: 60.5
VISCOSITY @ 77°F (25°C)
METHOD: ASTM D2196
TYPICAL RESULT: 15,000 cP (15 Pa•s)
SRI-SOLAR RELECTIVE INDEX
METHOD: ASTM E1980
TYPICAL RESULT: 111 - Initial 102 - 3 Year Aged
TECHNICAL DATA
ROC-246
RUST-OLEUM® 790
SYNTHETIC ROOF COATING
Rust-Oleum Corporation
11 Hawthorn Parkway
Vernon Hills, Illinois 60061
Phone: 8665858430
www.rustoleum.com
Form: ARJ-2370
Rev.: 033022
PHYSICAL PROPERTIES
790 SYNTHETIC ROOF COATING
Resin Type
Acylic, PVC, Fluoropolymer
Pigment Type
Titanium Dioxide
Solvents
Water
Weight
9.4 lbs./gal
Solids
By Weight
48.3%
By Volume
41.9%
Volatile Organic Compounds
<50 g/l
Recommended Dry Film Thickness
(DFT) Per Coat
Varies, substrate dependent
Wet Film to Achieve DFT
(Unthinned Material)
Varies, substrate dependent
Practical Coverage at Recommended
DFT (assumes 15% material loss)
Apply two coats at 0.75 gal./100 square feet (1.6 m2/L) (12 wet mils) per coat for a
total application rate of 1.5 gal./100 square feet (3.2 m2/L).
Dry Times at 77°F
(25ºC) and 50%
Relative Humidity
Touch
6 hours
Recoat
After 24 hours
Shelf Life
12 months in upopened containers when stored properly
WARNING
PROTECT FROM FREEZING
Safety Information
For additional information, see SDS
The technical data and suggestions for use contained herein are correct to the best of our knowledge, and offered in good faith. The
statements of this literature do not constitute a warranty, express, or implied, as to the performance of these products. As conditions and use
of our materials are beyond our control, we can guarantee these products only to conform to our standards of quality, and our liability, if any,
will be limited to replacement of defective materials. All technical information is subject to change without notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3

Rust-Oleum RUST-OLEUM ROC-246 790 Synthetic Roof Coating User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI