NICOR CCW-10-4S-UNV-50K Installation guide

Type
Installation guide
INSTALLATION INSTRUCTIONS
CAUTION:
For
your
safety
and
proper
operation
of
fixture,
read
instructions
carefully before you start. Note and understand all safety information in bold print.
CLOUD
LIGHT
FIXTURE
IMPORTANT
SAFETY
INFORMATION
FOR YOUR PROTECTION, READ CAREFULLY
1) WARNING: RISK OF SHOCK
House electric current can cause painful shock or serious injury unless handled properly.
For your safety, always remember to:
-Turn off the power supply at the fuse or circuit breaker box before you install the fixture.
-Turn off the power supply again when you change lamps or perform other maintenance.
-Ground the fixture to avoid potential electric shocks and to ensure reliable starting.
-Double check all connections to be sure they are all tight and correct.
-Wear rubber-soled shoes and work on a sturdy wooden ladder.
Couper le courant au niveau du disjoncteur avant d’installer la lampe pour éviter tout risque de
secousse électrique.
2) This fixture is designed for use in a circuit protected by a fuse or circuit breaker. It is also
designed to be installed in accordance with local electrical codes. If you are unsure about the
wiring, consult a qualified electrician and check your local electircal code.
Tous les branchements électrique doivent respecter les normes du Code National de l’Électricité.
Si vous ne savez pas comment installer correctement des fils électriques,appelez un électricien
professionnel.
3) WARNING: RISK OF CUTS
Some metal parts in the fixture may have sharp edges. To prevent possible cuts and scrapes,
we suggest gloves to be worn when handling all parts from this fixture.
4) Account for small parts and destroy packing material, as these may be hazardous to children.
5) WARNING: RISK OF FIRE
Most
dwellings
built
before
1985
have
supply
wire
rated
60
°
C.
If
supply
wires
are
located
within 3 inches of the driver, wire must be suitable for at least 90°C ( 194 ˚F ). Consult a
qualified electrician before installing.
Les fils d’alimentation 90 min.
A) LAMP HOUSING 1 UNIT C) WIREWAY COVER 1 UNIT A) PLIERS C) PHILPS SCREWDRIVER
B) LENS 1 UNIT D) WOOD SCREWS 4 UNITS B) HAMMER D) SAFETY CLASSES
E) WIRENUTS 3 UNITS
INSTALLATION
INSTRUCTIONS
WARNING: Before wiring to the power supply, turn off the electricity at fuse or circuit breaker
box. Ensure grounding to avoid potential electrical shock and to ensure reliable lamp starting.
PREPARATION OF LIGHT FIXTURE FOR INSTALLATION
1) Remove the Acrylic lens from the fixture and place aside on a flat surface to avoid damage
to the lens. To remove the lens, release the four "Lens-Locks" located 2 on either side of
the light from the closed position to the open position. Gently lift up the lens one side
first followed by the other side.
2) Squeeze wireway cover at both ends on both sides to release from the fixture housing.
Remove the cover and place aside on a flat surface for later use.
3) Carefully turn the fixture housing over and locate the center knockout on the housing. Make
sure the fixture housing is supported on the underside and then by placing a screwdriver
on the edge of the knockout ( opposite retaining tabs ), strike the screwdriver end by the
use of a hammer ( SAFETY GLOVES AND GLASSES SHOULD BE WORN WHEN
REMOVING ANY KNOCKOUTS ). Grasp the knockout with the use of pliers and flex in
a back and forth motion until the tab breaks off.
4) Coordinate mounting position in the room. Supply wires of house wires will extend from the
" JUNCTION BOX " located in the ceiling. If you not have a " JUNCTION BOX " in the ceiling,
consult a qualified professional electrician.
CAUTION
Check both the fixture and house for loose or damaged wiring. If the wiring is loose or
damaged, it must be repaired prior to the fixture installation. DO NOT PROCEED ON
UNTIL THE WIRING HAS BEEN FIXED OR REPLACED WITH NEW WIRES.
INSTALLATION
INSTRUCTIONS
NOTE: This fixture is designed to be surfaced mounted on a drywall ceiling. Mounting
hardware requirements will depend on mounting method.
MOUNTING OF THE LIGHT FIXTURE
A) For mounting on drywall ceilings:
1) Lift fixture housing to the ceiling, positioning
the center knockout of the housing over
the junction box and parallel to the ceiling.
See Diagram 1.
2) Mark ceiling with a pencil for the drill hole
locations throuth the narrow portion on the 4
keyhole slots. See Diagram 2, 3.
3) Drill 1/8" pilot hole at each location.
4) If drill encounters ceiling joist, use wood
screws ( provided ) & washers ( not
included ) to secure fixture housing to the
ceiling. See diagram 4.
5) If drill DOES NOT ENCOUNTER CEILING
JOIST, use 4 toggle bolts and washers
( both not included ). Enlarge the pilot drill
hole size large enough to accommodate
the toggle bolts tighten and secure fixture
housing to ceiling. See Diagram 5.
SAFETY TIP
6) Reinforce the mounting of the housing to the
ceiling by adding a board between the
expansion part of the toggle bolt and the
ceiling tile. See Diagram 6.
Diagram 3
Diagram
4
Diagram
5
Diagram
6
Diagram
1
Diagram
2
INSTALLATION
INSTRUCTIONS
WARNING: Before wiring to the power supply, turn off the electricity at fuse or circuit
breaker
box. Ensure grounding to avoid potential electrical shock and to ensure reliable lamp starting.
WIRING
OF
THE
LIGHT
FIXTURE
1)
Connect
the
black
supply
(
house
)
wire
to
the
black wire from the light fixture. Secure the
connection by inserting into the wirenut,
then revolving until secure.Diagram 1.
2)
Connect
the
white
supply
(
house
)
wire
to
the
white wire from the light fixture. Secure the
connection by inserting into the wirenut,
then revolving until secure.Diagram 1.
CHECK
TO
MAKE
SURE
NO
BARE
WIRES
ARE EXPOSED OUTSIDE THE WIRENUTS.
3)
To
ground
the
fixture,
connect
the
bare
or
green
supply ( house ) wire to the green wire comes
with the fixture by inserting into the wirenut,
then revolving until secure. Diagram 1.
DIMMING
1)
If
1
-
10
dimming
is
to
be
used,all
incoming
dimming supply leads must be Class 1(300V
minimum).If dimming is not to be used,cap
off fixture Purple and gray leads separately.
2)Connect the supply positive dimming lead to the
Purple lead from the fixture.Diagram 2.
3)Connect the supply negative dimming lead to
the Gray lead from the fixture.Diagram 2.
IF
THE
HOUSE
WIRING
DOES
NOT
HAVE
A GROUND WIRE, CONSULT YOUR LOCAL
ELECTRIC CODE FOR APPROVED METHOD.
Attacher le cable d’alimentation noir au cable noir
de
la
lampe
,et
le
Cable
d
alimentation
blanc
au
cable blanc de la lampe à l’aide des connecteurs,
Raccorder le fil de terre de la lampe au fil de terre
de
l
alimentation
en
utilisant
un
connecteur.
4) Replace the wireway cover by reversing the
steps as described on page 2, point 2. See
Diagram 3,4
THE FIXTURE SHOULD NOT BE OPERATED
WITHOUT THE WIREWAY COVER IN PLACE.
5)
Replace
the
lens
by
reversing
the
steps
as
described on page 2, point #1. See
Diagram 5.
BE
EXTREMELY
CAREFUL
WHEN
REPLACING
THE LENS BACK ON THE LIGHT FIXTURE TO
AVOID POSSIBLE DAMAGE TO THE LENS.
Diagram 3
Diagram 4
Diagram 5
Diagram 1
Diagram 2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

NICOR CCW-10-4S-UNV-50K Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI