PAGE 1 OF 3 0519 RH-8041
H-8041
COMPACT AUTO FLOOR SCRUBBER
QUICK USER'S GUIDE
1-800-295-5510
uline.com
π
NOTE: This guide is intended for quick reference
only, and does not replace the Use and
Maintenance Manual. Before using this machine,
read the Use and Maintenance Manual contained
in the machine packaging, and rigorously inspect
all the instructions.
1. Fill the detergent tank. (See Figure 1)
2. Adjust the slope of the handle by pulling the handle
release lever. (See Figure 2)
3. Lower the squeegee using the lever. (See Figure 3)
4. Open the detergent tank tap. (See Figure 4)
5. Press the On button. (See Figure 5)
6. Press the brush button to activate suction and water
delivery. (See Figure 6)
7. Operate the drive lever. (See Figure 7)
8. Begin working.
9. When you finish cleaning, proceed as follows:
Press the brush button. (See Figure 8)
Turn the machine off by pressing ON button for
at least four seconds.
Raise the squeegee.
Close the detergent tank tap.
If necessary, charge the batteries.
OPERATION
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 7
Figure 8
Figure 6
PAGE 2 OF 3 0519 RH-8041
MAINTENANCE
DAILY MAINTENANCE
1. Empty the dirty water tank. (See Figure 9)
2. Clean the dirty water tank. (See Figure 10)
3. Check the dirty water tank float is undamaged and
clean and moves freely on the pin. (See Figure 11)
4. Clean the brush (See Figure 12)
5. Check the squeegee is clean and the blades are
not damaged. (See Figure 13)
6. Check the battery charge. (See Figure 14)
7. To recharge the batteries, plug in the battery
charger using the electrical cord provided with the
machine. (See Figure 15)
REPLACING THE SQUEEGEE BLADE
Release the clip.
Remove the two blade retainers by pushing them to
the outside of the squeegee then extracting them.
Remove the blade.
Reuse the same blade by reversing the edge in
contact with the floor until all four edges are worn
out, or replace with a new blade, fitting it into the
screws of the body of the squeegee.
Reposition the two blade retainers by centering the
widest part of the slots over the fixing screws on the
squeegee, then pushing the blade retainers inward.
Fasten the clip.
CHECK MOTOR FUSES
1. Drain the recovery tank. Remove the recovery tank
by lifting up. (See Figure 15)
2. Locate fuse. (See Figures 16 -17)
3. Remove the vacuum or brush fuse. (See Figure 18)
Figure 9
Figure 10
Fi g u re 11
Figure 12
Figure 13
Figure 14
Figure 15
Figure 15
Brush motor fuse.
Vacuum motor fuse.
Figure 16
Figure 17
Figure 18
PAGE 3 OF 3 0519 RH-8041
OPERATING ISSUE RECOMMENDATIONS
The machine does not start. Check the battery charge.
The suction motor does not work. Check the dirty water tank is not full.
Check the dirty water tank lever sensor is not blocked/
malfunctioning.
Check vacuum motor fuse. (See Check Motor Fuses on page 2)
The machine leaves the floor wet. Check the squeegee blades are not worn.
Check there is no debris between the squeegee blades.
Check there is no debris in the suction hose.
Check the suction filter is undamaged and clean.
The machine leaves stripes of wet floor. Check the floor has been swept before using the machine.
Check there is no debris between the two squeegee blades.
Check the squeegee blades are not worn.
Check squeegee is correctly adjusted.
Brush motor will not start. Check brush motor fuse. (See Check Motor Fuses on page 2)
The brush motor thermal cutout has
tripped; the motorhead has overheated.
Release the brush lever button (LED off) and leave the machine
to cool down for at least 45 minutes.
TROUBLESHOOTING
MAINTENANCE CONTINUED
π
CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA
1-800-295-5510
uline.com
4. Check the fuse to see if it is blown by looking in the
fuse window. If the metal wire is present and not
broken, the fuse is good. If the metal wire is missing
or broken, the fuse is bad and needs to be replaced
with a new fuse. (See Figures 19-20)
5. Install a new fuse, and reattach the fuse cover.
Replace tank back on and test. (See Figure 20)
AUTOMATIC BRUSH REPLACEMENT
Attaching: insert the brush under the head, activate
the drive lever until it is attached.
Releasing: tilt machine back, activate drive lever
and release
Figure 19
Figure 20
/