Whirlpool AKM 207/IX Program Chart

Category
Cookers
Type
Program Chart

This manual is also suitable for

AKM 207 PRODUCT DESCRIPTION SHEET
NL
5019 319 61351
Operation of burners with
electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame setting .
At the same time, approach a flame to the
relative burner until it ignites.
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
Symbols
Shaded
circle
Tap closed
Large
flame
Maximum opening/delivery
Small
flame
Minimum opening or
reduced delivery
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY I2L
Type of gas used Type of
burner
Injector
marking
Rated heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat
capacity
Pcs-kW
Gas pressure
min. rat. max.
NATURAL GAS
(Methane) G 25
large
medium
small
129
108
78
3.00
1.90
1.00
332 l/h
210 l/h
111 l/h
0.60
0.35
0.35
20 25 30
Type of gas used Appliance model Total rated heat
capacity Pcs-kW
Total rated
consumption
Air required for
burning m
3
/h
G 25 25 mbar 4 gas 7.80 863 l/h 15.6