IKEA HOB 220 AN Program Chart

Type
Program Chart

IKEA HOB 220 AN is a 4-burner gas hob with electric ignition and safety features. It has medium, large, and small burners, each with its own control knob. To light a burner, press the relative knob and turn it anticlockwise to the desired flame setting, then press the button with the star symbol. The safety system prevents gas emission if the flame is accidentally extinguished.

IKEA HOB 220 AN is a 4-burner gas hob with electric ignition and safety features. It has medium, large, and small burners, each with its own control knob. To light a burner, press the relative knob and turn it anticlockwise to the desired flame setting, then press the button with the star symbol. The safety system prevents gas emission if the flame is accidentally extinguished.

HOB 220 PRODUCT DESCRIPTION SHEET
DE AT
5019 619 61711
Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame setting .
At the same time, press the button with the
star .
The spark plug gives out a spark that causes
the burner to ignite.
Once the burner is lit, keep the knob pressed
for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the
operation.
Note:
- Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
- The burner safety system serves to prevent
the emission of gas if the flame should be
extinguished accidentally (draughts,
interruptions in gas supply, dousing with
liquids, etc.).
For Austria only:
ÖVGW Directives G 1 and G 2 and local
building regulations must be complied with.
1. Removable panstand grids
2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
10. Electric ignition button
Symbols
Shaded
circle
Tap closed
Large flame Maximum opening/delivery
Small flame
Minimum opening or
reduced delivery
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
(DE) CATEGORY II2ELL3B/P
INJECTORS TABLE (AT) CATEGORY II2H3B/P
* Not supplied in Austria
Type of gas used Type of
burner
Injector
marking
Rated
heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat
capacity
Pcs-kW
Gas pressure
min. rat. max.
NATURAL GAS
(Methane) G 20
large
medium
small
128
94
76
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17 20 25
NATURAL GAS
(Methane)* G 25
large
medium
small
138
106
83
3.00
1.65
1.00
332 l/h
183 l/h
111 l/h
0.60
0.35
0.30
18 20 25
LIQUID
PETROLEUM GAS
(Cylinder) G 30
large
medium
small
79
58
46
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.85
0.52
0.46
42.5 50 57.5
LIQUID
PETROLEUM GAS
(Cylinder) G 31
large
medium
small
79
58
46
2.62
1.43
0.87
187 g/h
102 g/h
62 g/h
0.85
0.52
0.46
42.5 50 57.5
Type of gas used Appliance model Total rated heat
capacity Pcs-kW
Total rated
consumption
Air required for
burning m
3
/h
G 20 20 mbar 4G 7.30 695 l/h 14.6
G 25 20 mbar 4G 7.30 809 l/h 14.6
G 30 50 mbar 4G 7.30 531 g/h 14.6
G 31 50 mbar 4G 6.35 453 g/h 12.7
  • Page 1 1
  • Page 2 2

IKEA HOB 220 AN Program Chart

Type
Program Chart

IKEA HOB 220 AN is a 4-burner gas hob with electric ignition and safety features. It has medium, large, and small burners, each with its own control knob. To light a burner, press the relative knob and turn it anticlockwise to the desired flame setting, then press the button with the star symbol. The safety system prevents gas emission if the flame is accidentally extinguished.