BUNN
®
practicescontinuousproductresearchandimprovement.Wereservetherighttochangespecicationsandproductdesignwithoutnotice.Such
revisionsdonotentitlethebuyertocorrespondingchanges,improvements,additionsorreplacementsforpreviouslypurchasedequipment.
Alldimensionsshownininches. Bunn Corporation owns all copyrights relating to materials in this publication. Please contact Bunn Corporation to request permission to reproduce any portion of this publication.
Dimensions & Specifications
Bunn-O-MaticCorporationofCanada-280IndustrialPkwy.S.Aurora,OntarioL4G3T9•905-841-2866•Fax905-841-2775•www.bunn.com
CANADA
†
All models can be changed to these electrical configurations.
Model Product Dispense Rate/Sec. Connector Volts Amps Htr Capacity** Cubic Weight Cord
Number 1.8 oz. 2.5 oz.* Type Watts per hour ft
3
/m
3
lbs/kg Attached
Product Ratios
LCR-2C 34400.6044
†
45:1-100:165:1-100:1 Scholle 120 14.2 1500 125cups 10.9/.309 114/51.7 Yes***
LCR-2C 34400.6045
†
25:1-45:125:1-65:1 Scholle 120 14.2 1500 125cups 10.9/.309 114/51.7 Yes***
LCR-2C 34400.6046
†
45:1-100:165:1-100:1 LiquiBoxQC/DII 120 14.2 1500 125cups 10.9/.309 114/51.7 Yes***
LCR-2C 34400.6047
†
25:1-45:125:1-65:1 LiquiBoxQC/DII 120 14.2 1500 125cups 10.9/.309 114/51.7 Yes***
208 25.8 4500 385cups 10.9/.309 114/51.7 No
240 25.8 6000 512cups 10.9/.309 114/51.7 No
LCR-2CPC36500.6044
†
45:1-100:165:1-100:1 Scholle 120 14.2 1500 125cups 10.9/.309 114/51.7 Yes***
LCR-2CPC36500.6045
†
25:1-45:125:1-65:1 Scholle 120 14.2 1500 125cups 10.9/.309 114/51.7 Yes***
LCR-2CPC36500.6046
†
45:1-100:165:1-100:1 LiquiBoxQC/DII 120 14.2 1500 125cups 10.9/.309 114/51.7 Yes***
LCR-2CPC36500.6047
†
25:1-45:125:1-65:1 LiquiBoxQC/DII 120 14.2 1500 125cups 10.9/.309 114/51.7 Yes***
208 25.8 4500 385cups 10.9/.309 114/51.7 No
240 25.8 6000 512cups 10.9/.309 114/51.7 No
*Unit shipped with dispense rate set at 1.8 oz./sec. Dispense rate increases to 2.5 oz./sec. if restrictor plug is removed.
**Capacity measured with a 5 oz. cup. ***Power cord (NEMA 5-20P) 20 Amp-120V machine only.
Electrical: 120Vmodelrequires2-wiresplusgroundservicerated120V,singlephase,60hz.
Plumbing: 20-90psi(138-621kPa)froma
3
⁄
8
"(10mm)orlargersupplyline.Unitrequiresa2.2gpmlineowcapacity.Ashut-off
valveshouldbeinstalledinthelinebeforetheunit.Installaregulatorinlinewhenpressureisgreaterthan90psitore-
ducepressureto50psi.Suppliedwith
3
⁄
8
"(10mm)malearetting.
†
All models can be changed to these electrical configurations.
13.37
24.83
9.74
12.16
7.75
5.29
1.6
29.69
38.00
15.70
19.57
31.32
LCR-2 with portion control.