Dacor ILHSF8 Planning Guides PDF [0.75 MB]

Type
Planning Guides PDF [0.75 MB]
PLANNING
GUIDE
www.Dacor.com Phone: (800) 793-0093
Specications subject to change without notice.
Install all appliances according to accompanying installation instructions.
9.5
In-line Blower
ILHSF8, ILHSF10
ILHS8 OVERALL DIMENSIONS
3/16” (0.5 cm)
(16.5 cm)
6 ½"
(33.6 cm)
13 ¼"
(33.0 cm)
Air Flow
13”
(20.3 cm)
(20.8 cm)
8” REF
8 3/16”
(5.7 cm)
2 1/4”
(20.3 cm)
8” REF
(33.0 cm)
13”
(15.2 cm)
6”
(41.9 cm)
16 ½"
3/16” (0.5 cm)
15 1/4”
(38.7 cm)
19”
(48.3 cm)
16”
(40.6 cm)
8 1/4”
(21.0 cm)
15 3/4”
(40.0 cm)
10 3/4”
(27.3 cm)
2 1/4”
(5.7 cm)
10” REF
(25.4 cm)
10” REF
(25.4 cm)
9 1/8”
(23.2 cm)
Air Flow
ILHSF10 OVERALL DIMENSIONS
All tolerances ±1/16” (±1.6 mm) unless otherwise noted.
WARNING
Observe all governing codes and ordinances •
during planning and installation. Contact your local
building department for further information.
This appliance must be installed in accordance •
with the accompanying installation instructions.
Document # PG09 - 002
Revised 12/09/09 Page 1/2
PLANNING
GUIDE
www.Dacor.com Phone: (800) 793-0093
Specications subject to change without notice.
Install all appliances according to accompanying installation instructions.
9.6
In-line Blowers
ILHSF8, ILHSF10
Model Number Power Requirements* Blower Rating
ILHSF8
120 Vac, 60 Hz.,
3.5 Amp.
600 CFM**
620.7 CFM***
ILHSF10
120 Vac, 60 Hz.,
4.5 Amp.
1100 CFM**
1115.9 CFM***
* In addition to the hood or raised vent
** Nominal at 0 inches static pressure
*** Actual at 0 inches static pressure
Model Number Weight
ILHSF8 22 lbs. (10 kg.)
ILHSF10 31 lbs. (14 kg.)
ELECTRICAL ACCESS KNOCK-OUTS
NOTE:
The above specifications are for reference only. See the 1.
data label on the blower for exact specifications. If the
above specifications vary from the label on the blower,
use the data on the blower label.
Install this blower only with approved Dacor hoods/2.
vents. See the hood/vent installation instructions to
determine suitability.
All models are thermally protected3.
GRN
L1
BLU
BLK
GND
N1
Knock-out
Knock-out
Airflow CFM (Cubic feet/minute)
Static pressure - inches of water
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
200 400 600 800 1000 1200
ILHSF10 Blower Performance
Airflow CFM (Cubic feet/minute)
Static pressure - inches of water
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
200400 600800
ILHSF8 Blower Performance
WARNING
To avoid the risk of fire due to the unit overheating:
DO NOT• install this blower with a hood or raised vent that
has an internal blower.
DO NOT• install more than one blower to increase the length
of the duct run. Even small differences between blower air
flow rates can greatly reduce the air draw by the hood or
raised vent.
Document # PG09 - 002