Panasonic CU-E7GKE Datasheet

Category
Split-system air conditioners
Type
Datasheet
© 2006 Panasonic HA Air-Conditioning (M) Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
Order No. MAC0611054C2
Air Conditioner
CS-E7GKEW CU-E7GKE
CS-E9GKEW CU-E9GKE
CS-E12GKEW CU-E12GKE
TABLE OF CONTENTS
PAGE PAGE
1 Safety Precaution ------------------------------------------------ 2
2 Specifications ----------------------------------------------------- 4
2.1. CS-E7GKEW CU-E7GKE ------------------------------ 4
2.2. CS-E9GKEW CU-E9GKE ------------------------------ 6
2.3. CS-E12GKEW CU-E12GKE--------------------------- 8
3Features------------------------------------------------------------10
4 Location of Controls and Components ------------------11
4.1. Product Overview-----------------------------------------11
5Dimensions--------------------------------------------------------12
5.1. Indoor Unit--------------------------------------------------12
5.2. Outdoor Unit -----------------------------------------------13
6 Refrigeration Cycle Diagram --------------------------------14
7 Block Diagram----------------------------------------------------15
8 Wiring Connection Diagram --------------------------------16
8.1. Indoor Unit--------------------------------------------------16
8.2. Outdoor Unit -----------------------------------------------17
9 Electronic Circuit Diagram -----------------------------------18
9.1. Indoor Unit------------------------------------------------- 18
9.2. Outdoor Unit----------------------------------------------- 19
10 Printed Circuit Board------------------------------------------ 20
10.1. Indoor Unit------------------------------------------------- 20
10.2. Outdoor Unit----------------------------------------------- 22
11 Installation Instruction ----------------------------------------23
11.1. Select The Best Location ------------------------------23
11.2. Indoor/Outdoor Unit Installation Diagram----------23
11.3. Indoor Unit-------------------------------------------------24
11.4. Outdoor Unit-----------------------------------------------27
12 Operation and Control ---------------------------------------- 30
12.1. Basic Function--------------------------------------------30
12.2. Protection Control---------------------------------------- 40
13 Servicing Mode--------------------------------------------------44
13.1. Auto OFF/ON Button------------------------------------44
13.2. Select Remote Control Transmission Code-------44
13.3. Remote Control Button ---------------------------------45
2
14 Troubleshooting Guide----------------------------------------46
14.1. Refrigeration Cycle System ---------------------------46
14.2. Breakdown Self Diagnosis Function ----------------48
14.3. Error Codes Table----------------------------------------49
15 Disassembly and Assembly Instructions---------------50
15.1. Indoor Electronic Controllers, Cross Flow Fan
and Indoor Fan Motor Removal Procedures------50
15.2. Outdoor Electronic Controller Removal
Procedure-------------------------------------------------- 54
16 Technical Data--------------------------------------------------- 55
16.1. Operation Characteristics ----------------------------- 55
16.2. Sensible Capacity Chart ------------------------------- 67
17 Exploded View and Replacement Parts List----------- 68
17.1. Indoor Unit------------------------------------------------- 68
17.2. Outdoor Unit ---------------------------------------------- 70
1 Safety Precaution
Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.
Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and
main circuit for the model installed.
The caution items stated here must be followed because these important contents are related to safety. The meaning of each
indication used is as below. Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage, and
the seriousness is classified by the following indications.
The items to be followed are classified by the symbols:
Carry out test running to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, care and
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties.
This symbol denotes item that is PROHIBITTED from doing.
1. Engage dealer or specialist for installation and servicing. If installation or servicing done by the user is defective, it will cause water
leakage, electrical shock or fire.
2. Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire.
3. Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage,
fire or electrical shock.
4. Install at a strong and firm location which is able to withstand the set's weight. If the strength is not enough or installation is not properly
done, the set will drop and cause injury.
5. For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single
outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
6. Use the specified cable and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no external force will
be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
7. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause
heat-up at connection point of terminal, fire or electrical shock.
8. When connecting the piping, do not allow air or any substances other than the specified refrigerant to enter the refrigeration
cycle. Otherwise, this may lower the capacity, cause abnormally high pressure in the refrigeration cycle, and possibly result in
explosion and injury.
9. Thickness of copper pipes used must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm.
10. It is desirable that the amount of residual oil is less than 40 mg/10 m.
11. Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with other
electrical appliances. Otherwise, it will cause fire or electrical shock.
3
1. The equipment must be earthed. It may cause electrical shock if grounding is not perfect.
2. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of
the unit, it may cause fire.
3. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the
furniture.
4. Pb free solder has a higher melting point than standard solder; typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high
temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).Pb free solder
will tend to splash when heated too high (about 1100°F/600°C).
1. Selection of the installation location. Select an installation location which is rigid and strong enough to support or hold the unit, and select
a location for easy maintenance.
2. Power supply connection to the conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following
methods.
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency.
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
1. Power supply connection to the receptacle using a power plug. Use an approved power plug with earth pin for the connection to the
socket.
2. Power supply connection to a circuit breaker for the permanent connection. Use an approved circuit breaker for the permanent
connection. It must be a double pole switch with a minimum 3.5 mm contact gap.
3. Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigeration parts. Take care of
the liquid refrigerant, it may cause frostbite.
4. Installation work. It may need two people to carry out the installation work.
5. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
4
2 Specifications
2.1. CS-E7GKEW CU-E7GKE
ITEM UNIT INDOOR UNIT OUTDOOR UNIT
Performance Test Condition EUROVENT
C
O
O
L
I
N
G
Capacity
kW 2.05 (0.70 ~ 2.40)
kCal/h 1760 (600 ~ 2060)
EER
W/W 4.27 (4.12 ~ 4.07)
kCal/hW 3.67 (3.53 ~ 3.49)
Noise Level
dB (A) High 37, Low 24 High 45
Power level dB 48 58
H
E
A
T
I
N
G
Capacity
kW 2.80 (0.70 ~ 4.00)
kCal/h 2410 (600 ~ 3440)
COP
W/W 4.31 (4.38 ~ 3.92)
kCal/hW 3.71 (3.75 ~ 3.37)
Noise Level
dB (A) High 38, Low 25 High 46
Power level dB 49 59
Moisture Removal
l/h 1.3
pt/h 2.7
Air Volume
Lo
m
3
/min (ft
3
/min)
Cooling; 6.3 (220)
Heating; 6.5 (230)
Me
m
3
/min (ft
3
/min)
Cooling; 8.0 (280)
Heating; 8.4 (300)
Hi
m
3
/min (ft
3
/min)
Cooling; 9.8 (350)
Cooling; 28.8 (1020)
Heating; 10.3 (360)
SHi
m
3
/min (ft
3
/min)
Cooling; 10.1 (360)
Heating; 10.7 (380)
Refrigeration Control Device Check Valve & Capillary Tube
Refrigeration Oil
cm
3
RB68A or Freol Alpha68M (320)
Refrigerant (R410A) g (oz) 790 (27.9)
Dimension
Height mm (inch) 280 (11-1/32) 540 (21-1/4)
Width mm (inch) 799 (31-15/32) 780 (30-23/32)
Depth mm (inch) 183 (7-7/32) 289 (11-3/8)
Net Weight kg (lbs) 9 (20) 33 (73)
Pipe Diameter
Gas mm (inch) 9.52 (3/8)
Liquid mm (inch) 6.35 (1/4)
Standard Length m (ft) 7.5 (24.6)
Pipe Length Range m (ft) 3 (9.8) ~ 15 (49.2)
Height Difference m (ft) 15 (49.2)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Refrigeration Charge Less m (ft) 7.5 (24.6)
Drain Hose
Inner Diameter mm 16
Length mm 650
Compressor
Type Hermetic Motor
Motor Type Brushless (6-pole)
Rated Output W 650
Fan
Type Cross-Flow Fan Propeller Fan
Material ASG20K1 PP
Motor Type Transistor (8-pole) Induction (6-pole)
Input Power W 62
Output Power W 30 25
Fan Speed
Lo (Cool/Heat) rpm 790 / 820
Me (Cool/Heat) rpm 1010 / 1060
Hi (Cool/Heat) rpm 1230 / 1300 750 / -
SHi (Cool/Heat) rpm 1270 /1340
5
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
Note
Specifications are subject to change without notice for further improvement.
ITEM UNIT INDOOR UNIT OUTDOOR UNIT
Heat Exchanger
Fin Material Aluminium (Pre Coat) Aluminium
Fin Type Slit Fin Corrugated Fin
Row x Stage x FPI 2 x 15 x 19 2 x 24 x 17
Size (W x H x L) mm 610 x 315 x 25.4
36.4 x 504 x 713
684
Air Filter
Material Polypropelene
Type One-Touch
Item Unit
Power Source (Phase, Voltage, Cycle)
ø Single
V 230
Hz 50
Input Power W
Cooling; 480 (170 ~ 590)
Heating; 650 (160 ~ 1020)
Starting Current A 3.1
Running Current A
Cooling; 2.3
Heating; 3.1
Power Factor %
Cooling; 91
Heating; 91
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection A 4.8
Power Cord
Number of core
Length m
Thermostat Electronic Control
Protection Device Electronic Control
6
2.2. CS-E9GKEW CU-E9GKE
ITEM UNIT INDOOR UNIT OUTDOOR UNIT
Performance Test Condition EUROVENT
C
O
O
L
I
N
G
Capacity
kW 2.60 (0.80 ~ 3.00)
kCal/h 2240 (690 ~ 2580)
EER
W/W 4.41 (4.57 ~ 4.00)
kCal/hW 3.80 (3.94 ~ 3.44)
Noise Level
dB (A) High 39, Low 25 High 46
Power level dB 50 59
H
E
A
T
I
N
G
Capacity
kW 3.60 (0.80 ~ 5.00)
kCal/h 3100 (690 ~ 4300)
COP
W/W 4.31 (4.85 ~ 3.73)
kCal/hW 3.71 (4.18 ~ 3.21)
Noise Level
dB (A) High 40, Low 27 High 47
Power level dB 51 60
Moisture Removal
l/h 1.6
pt/h 3.4
Air Volume
Lo
m
3
/min (ft
3
/min)
Cooling; 6.6 (230)
Heating; 7.1 (250)
Me
m
3
/min (ft
3
/min)
Cooling; 8.5 (300)
Heating; 9.1 (320)
Hi
m
3
/min (ft
3
/min)
Cooling; 10.4 (370)
Cooling; 29.8 (1050)
Heating; 11.0 (390)
SHi
m
3
/min (ft
3
/min)
Cooling; 10.7 (380)
Heating; 11.4 (400)
Refrigeration Control Device Check Valve & Capillary Tube
Refrigeration Oil
cm
3
RB68A or Freol Alpha68M (320)
Refrigerant (R410A) g (oz) 965 (34.1)
Dimension
Height mm (inch) 280 (11-1/32) 540 (21-1/4)
Width mm (inch) 799 (31-15/32) 780 (30-23/32)
Depth mm (inch) 183 (7-7/32) 289 (11-3/8)
Net Weight kg (lbs) 9 (20) 34 (75)
Pipe Diameter
Gas mm (inch) 9.52 (3/8)
Liquid mm (inch) 6.35 (1/4)
Standard Length m (ft) 7.5 (24.6)
Pipe Length Range m (ft) 3 (9.8) ~ 15 (49.2)
Height Difference m (ft) 15 (49.2)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Refrigeration Charge Less m (ft) 7.5 (24.6)
Drain Hose
Inner Diameter mm 16
Length mm 650
Compressor
Type Hermetic Motor
Motor Type Brushless (6-pole)
Rated Output W 700
Fan
Type Cross-Flow Fan Propeller Fan
Material ASG20K1 PP
Motor Type Transistor (8-pole) Induction (6-pole)
Input Power W 65
Output Power W 30 25
Fan Speed
Lo (Cool/Heat) rpm 830 / 900
Me (Cool/Heat) rpm 1070 / 1150
Hi (Cool/Heat) rpm 1310 / 1400 770 / -
SHi (Cool/Heat) rpm 1350 / 1440
7
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
Note
Specifications are subject to change without notice for further improvement.
Heat Exchanger
Fin Material Aluminium (Pre Coat) Aluminium
Fin Type Slit Fin Corrugated Fin
Row x Stage x FPI 2 x 15 x 19 2 x 24 x 17
Size (W x H x L) mm 610 x 315 x 25.4
36.4 x 504 x 713
684
Air Filter
Material Polypropelene
Type One-Touch
Item Unit
Power Source (Phase, Voltage, Cycle)
ø Single
V 230
Hz 50
Input Power W
Cooling; 590 (175 ~ 750)
Heating; 835 (165 ~ 1340)
Starting Current A 3.9
Running Current A
Cooling; 2.8
Heating; 3.9
Power Factor %
Cooling; 92
Heating; 93
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection A 5.9
Power Cord
Number of core
Length m
Thermostat Electronic Control
Protection Device Electronic Control
ITEM UNIT INDOOR UNIT OUTDOOR UNIT
8
2.3. CS-E12GKEW CU-E12GKE
ITEM UNIT INDOOR UNIT OUTDOOR UNIT
Performance Test Condition EUROVENT
C
O
O
L
I
N
G
Capacity
kW 3.50 (0.80 ~ 4.00)
kCal/h 3010 (690 ~ 3440)
EER
W/W 3.68 (4.32 ~ 3.33)
kCal/hW 3.17 (3.73 ~ 2.87)
Noise Level
dB (A) High 42, Low 28 High 48
Power level dB 53 61
H
E
A
T
I
N
G
Capacity
kW 4.80 (0.80 ~ 6.50)
kCal/h 4130 (690 ~ 5590)
COP
W/W 3.75 (4.57 ~ 3.40)
kCal/hW 3.23 (3.94 ~ 2.93)
Noise Level
dB (A) High 42, Low 33 High 50
Power level dB 53 63
Moisture Removal
l/h 2.0
pt/h 4.2
Air Volume
Lo
m
3
/min (ft
3
/min)
Cooling; 7.0 (250)
Heating; 8.5 (300)
Me
m
3
/min (ft
3
/min)
Cooling; 9.1 (320)
Heating; 10.1 (360)
Hi
m
3
/min (ft
3
/min)
Cooling; 11.2 (400)
Cooling; 31.0 (1090)
Heating; 11.7 (410)
SHi
m
3
/min (ft
3
/min)
Cooling; 11.5 (410)
Heating; 12.1 (430)
Refrigeration Control Device Check Valve & Capillary Tube
Refrigeration Oil
cm
3
RB68A or Freol Alpha68M (320)
Refrigerant (R410A) g (oz) 980 (34.6)
Dimension
Height mm (inch) 280 (11-1/32) 540 (21-1/4)
Width mm (inch) 799 (31-15/32) 780 (30-23/32)
Depth mm (inch) 183 (7-7/32) 289 (11-3/8)
Net Weight kg (lbs) 9 (20) 35 (77)
Pipe Diameter
Gas mm (inch) 9.52 (3/8)
Liquid mm (inch) 6.35 (1/4)
Standard Length m (ft) 7.5 (24.6)
Pipe Length Range m (ft) 3 (9.8) ~ 15 (49.2)
Height Difference m (ft) 15 (49.2)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Refrigeration Charge Less m (ft) 7.5 (24.6)
Drain Hose
Inner Diameter mm 16
Length mm 650
Compressor
Type Hermetic Motor
Motor Type Brushless (6-pole)
Rated Output W 700
Fan
Type Cross-Flow Fan Propeller Fan
Material ASG20K1 PP
Motor Type Transistor (8-pole) Induction (6-pole)
Input Power W 70
Output Power W 30 30
Fan Speed
Lo (Cool/Heat) rpm 900 / 1080
Me (Cool/Heat) rpm 1165 / 1290
Hi (Cool/Heat) rpm 1430 / 1500 830 / -
SHi (Cool/Heat) rpm 1470 / 1540
9
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
Note
Specifications are subject to change without notice for further improvement.
Heat Exchanger
Fin Material Aluminium (Pre Coat) Aluminium
Fin Type Slit Fin Corrugated Fin
Row x Stage x FPI 2 x 15 x 21 2 x 24 x 17
Size (W x H x L) mm 610 x 315 x 25.4
36.4 x 504 x 713
684
Air Filter
Material Polypropelene
Type One-Touch
Item Unit
Power Source (Phase, Voltage, Cycle)
ø Single
V 230
Hz 50
Input Power W
Cooling; 950 (185 ~ 1200)
Heating; 1280 (175 ~ 1910)
Starting Current A 5.9
Running Current A
Cooling; 4.4
Heating; 5.9
Power Factor %
Cooling; 94
Heating; 94
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection A 8.8
Power Cord
Number of core
Length m
Thermostat Electronic Control
Protection Device Electronic Control
ITEM UNIT INDOOR UNIT OUTDOOR UNIT
10
3Features
Product
- Four modes of operation selection
- Powerful mode to reach the desired room temperature
quickly with full power and a strong airflow
- Quiet mode to provide a quiet environment by reducing
the indoor unit operating airflow sound
- 24-hour ON Timer and OFF Timer setting
- Air swing manual and automatic adjusted by Remote
Control for vertical airflow and the horizontal airflow
direction louvers can be adjusted manually by hand
- Patrol sensor automatically detect the air quality. When
the air quality is unsatisfactory, e-ion operation will start
automatically.
- e-ion Air Purifying System provides clean air by
producing negative ions to attract dust which will then be
captured at the positively charged e-ion filters.
Serviceability Improvement
- Removable and washable Front Panel
- Breakdown Self Diagnosis function
Environmental Protection
- Non-ozone depletion substances refrigerant (R410A)
Operation Improvement
- Random auto restart control after power failure for safety
restart operation
- Advanced inverter technology provides outstanding
energy efficiency and powerful, flexible, comfortable
operation
11
4 Location of Controls and Components
4.1. Product Overview
4.1.1. Indoor Unit
4.1.2. Outdoor Unit
4.1.3. Remote Control
12
5 Dimensions
5.1. Indoor Unit
13
5.2. Outdoor Unit
14
6 Refrigeration Cycle Diagram
If piping length is over common length, additional refrigerant should be added as shown in the table.
Model
Piping size Rated
Length
(m)
Common
Length
(m)
Max.
Elevation
(m)
Max. Piping
Length
(m)
Additional
Refrigerant
(g/m)
Gas Liquid
E7GK, E9GK, E12GK 3/8” 1/4” 7.5 7.5 15 15 20
15
7 Block Diagram
16
8 Wiring Connection Diagram
8.1. Indoor Unit
17
8.2. Outdoor Unit
18
9 Electronic Circuit Diagram
9.1. Indoor Unit
19
9.2. Outdoor Unit
20
10 Printed Circuit Board
10.1. Indoor Unit
10.1.1. Main Printed Circuit Board
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Panasonic CU-E7GKE Datasheet

Category
Split-system air conditioners
Type
Datasheet

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI