Franke Consumer Products FDL 304 W User manual

Category
Cooker hoods
Type
User manual

This manual is also suitable for

EN
2
2
INDEX
WARNINGS AND REQUIREMENTS.....................................................................................................................................3
RECOMMENDATIONS AND SUGGESTIONS......................................................................................................................6
DIMENSIONS and MAIN PARTS...........................................................................................................................................7
INSTALLATION......................................................................................................................................................................8
USE.......................................................................................................................................................................................11
CARE....................................................................................................................................................................................12
EN
3
3
READ AND SAVE THESE INSTRUCTIONS
The Installer must leave these instructions with the homeowner.
The homeowner must keep these instructions for future reference and for local electrical inspec-
tors’ use.
READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD
WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Never leave surface units
unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly
on low or medium setting. Always turn hood ON when cooking at high heat or when flambéing food (i.e.
Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé. Clean ventilating fans frequently. Grease should
not be allowed to accumulate on fan or filter. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE
TOP GREASE FIRE, OBSERVE THE FOLLOWING: SMOTHER FLAMES
with a close-fitting
lid, cookie sheet, or metal tray, then turn off the burner
. BE CAREFUL TO PREVENT BURNS. If
the flames do not go out immediately
EVACUATE AND CALL THE FIRE DEPARTMENT.
NEVER PICK UP A FLAMING PAN -
You may be burned. DO NOT USE WATER, including wet
dishcloths or towels - a violent steam explosion will result. Use an extinguisher ONLY if: 1. You
know you have a Class ABC extinguisher, and you already know how to operate it. 2. The fire is
small and contained in the area where it started. 3. The fire department is being called. 4. You
can fight the fire with your back to an exit
.
ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE
SEALED.
This rangehood requires at least 24" of clearance between the bottom of the rangehood and the
cooking surface or countertop. Consult the cooktop or range installation instructions given by the
manufacturer before making any cutouts. MOBILE HOME INSTALLATION. The installation
of this rangehood must conform to the Manufactured Home Construction and Safety Standards,
Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home Construction and Safety,
Title 24, HUD, Part 280). Four wire power supply must be used and the appliance wiring must be
revised. See Electrical Requirements.
VENTING REQUIREMENTS
CAUTION - To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent ex-
haust air into spaces within walls or ceilings or into attics, crawl spaces, or garages".
Determine which venting method is best for your application. Ductwork can extend either
through the wall or the roof. The length of the ductwork and the number of elbows should be
kept to a minimum to provide efficient performance. The size of the ductwork should be uni-
form. Do not install two elbows together. Use duct tape to seal all joints in the ductwork system.
Use caulking to seal exterior wall or floor opening around the cap.
Flexible ductwork is not recommended. Flexible ductwork creates back pressure and air turbu-
lence that greatly reduces performance.
Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts.
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting
frame must be constructed.
WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.
EN
4
4
W A R N I N G
• Venting system MUST terminate outside the home.
• DO NOT terminate the ductwork in an attic or other enclosed space.
• DO NOT use 4" laundry-type wall caps.
• Flexible-type ductwork is NOT recommended.
• DO NOT obstruct the flow of combustion and ventilation air.
• Failure to follow venting requirements may result in a fire.
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A
timedelay fuse or circuit breaker is recommended. The fuse must be sized per local codes in ac-
cordance with the electrical rating of this unit as specified on the serial/rating plate located inside
the unit near the field wiring compartment. THIS UNIT MUST BE CONNECTED WITH COP-
PER WIRE ONLY. Wire sizes must conform to the requirements of the National Electrical Co-
de, ANSI/NFPA 70 - latest edition, and all local codes and ordinances. Wire size and connections
must conform with the rating of the appliance. Copies of the standard listed above may be obtai-
ned from:
National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
This appliance should be connected directly to the fused disconnect (or circuit breaker) through
flexible, armored or nonmetallic sheathed copper cable. Allow some slack in the cable so the ap-
pliance can be moved if servicing is ever necessary. A UL Listed, 1/2" conduit connector must
be provided at each end of the power supply cable (at the appliance and at the junction box).
When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood
must be sanded until smooth. A hole through metal must have a grommet.
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
do not use this fan with
any solid-state speed control device.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the manufac-
turer. If you have any questions, contact the manufacturer.
Before servicing or cleaning unit, switch power off at service panel and lock the service discon-
necting means to prevent power from being switched on accidentally. When the service discon-
necting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the
service panel.
CAUTION:
For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or Explosive Materials
and Vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING: Installation Work And Electrical Wiring Must Be
Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, In-
EN
5
5
cluding Fire-Rated Construction.
Sufficient air is needed for proper combustion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden
utilities.
Ducted fans must always be vented to the outdoors.
W A R N I N G
Electrical ground is required on this rangehood.
• If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO
NOT use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or ground-
ing circuit could result in electrical shock
• Check with a qualified electrician if you are in doubt as to whether the rangehood is prop-
erly grounded.
• Failure to follow electrical requirements may result in a fire.
EN
6
6
RECOMMENDATIONS AND SUGGESTIONS
The Instructions for Use apply to several versions of this appliance. Accord-
ingly, you may find descriptions of individual features that do not apply to
your specific appliance.
INSTALLATION
The manufacturer will not be held liable for any damages resulting from incor-
rect or improper installation.
Check that the main voltage corresponds to that indicated on the rating plate
fixed to the inside of the hood.
The electrical supply must be properly and sufficiently grounded.
Connect the extractor to the exhaust flue through a pipe of minimum diameter
6”. The route of the flue must be as short as possible.
Do not connect the extractor hood to exhaust ducts carrying combustion fumes
(boilers, fireplaces, etc.).
If the extractor is used in conjunction with non-electrical appliances (e.g. gas
burning appliances), a sufficient degree of aeration must be guaranteed in the
room in order to prevent the backflow of exhaust gas. The kitchen must have
an opening communicating directly with the open air in order to guarantee the
entry of clean air.
USE
The range hood has been designed exclusively for domestic use to eliminate
kitchen odors.
Never use the hood for purposes other than for which it has ben designed.
Never leave high naked flames under the hood when it is in operation.
Adjust the flame intensity to direct it onto the bottom of the pan only, making
sure that it does not engulf the sides.
Deep fat fryers must be continuously monitored during use: overheated oil can
burst into flames.
The hood should not be used by children or persons not instructed in its cor-
rect use.
CARE
Switch off or unplug the appliance from the main supply before carrying out
any maintenance work.
Clean and/or replace the Filters after the specified time period.
Clean the hood using a damp cloth and a neutral liquid detergent..
EN
7
7
DIMENSIONS and MAIN PARTS
Dimensions
-
Components
Ref. Q.ty Product Components
1 1 Hood Body, complete with: Controls, Light, Blower,
Filters
2 1 Telescopic Chimney comprising:
2.1 1 Upper Section
2.2 1 Lower Section
10 1 Damper
15 1 Air Outlet Connection
Ref. Q.ty Installation Components
7.1 2 Hood Body Fixing Brackets
7.2.1 1 Upper Chimney Section Fixing Brackets
7.3 1 Air Outlet Connection Support
11 8 Wall Plugs (if supplied)
12a 8 Screws 3/16” x 1” 3/4
12c 6 Screws 1/8” x 3/8”
12d 2 Screws 3/16” x 1”
12e 2 Screws 1/8” x 1/2“
Q.ty Documentation
1 Instruction Manual
7.2.1
1
7.3
12a
11
12e
15
12c
12c
12c
2.1
2.2
2
10
7.1
12a 11
12d
EN
8
8
INSTALLATION
Wall drilling and bracket fixing
Wall marking:
Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the
center of the area in which the hood will be installed.
Draw a horizontal line at 24” above the hob for installation without the back panel, or at
height H (height of the visible part of the panel) for installation with the back panel.
• Place bracket 7.3 on the wall as shown about 1/16” from the ceiling or upper limit, aligning
the center (notch) with the vertical reference line.
Mark the wall at the centers of the holes in the bracket.
Place bracket 7.2.1 on the wall as shown at X” below the first bracket (X = height of the up-
per chimney section supplied), aligning the center (notch) with the vertical line.
Mark the wall at the centers of the holes in the bracket.
• Place bracket 7.1 as shown 4” 5/16 from the vertical reference line and 7” 1/2 above the
horizontal reference line.
Mark the centres of the holes in the bracket.
Repeat this operation on the other side.
REAR PANEL (OPTIONAL)
The Rear Panel must be fitted before fixing the hood body and, if it is to be fixed at both top
and bottom, must be fitted at the correct height prior to installing the bases. As this operation is
rather complex, it should be carried out either by the kitchen installer or a qualified person
who knows the final dimensions of the units.
For fixing at the top only, proceed as follows:
Rest the back panel on the base, inserting the lower plate between the upper surface and the
wall, centring it on the vertical reference line.
Mark the centres of the two holes in the upper plate.
Drill ø 5/16” holes at all the centre points marked.
Insert the wall plugs 11 in the holes.
Fix the brackets using the 12a screws supplied.
Fix the back panel (where present) using the 12a screws supplied.
H
X
7.2.1
7.1
7.3
÷1/16"
7"1/2
24"
4" 5/16
4" 5/16
EN
9
9
Mounting the hood body
Screw the two screws 12d supplied onto the brackets 7.1.
Hook the hood body onto the bracket 7.1, centring it around
the vertical line.
Use the adjusting screws 12d underneath the hood to level the
hood body.
Note: The Hood body should be secured to wall studs. If neces-
sary, install a wood support behind the dry wall, flush mounted
between 2 studs. This will provide the necessary structure and
support for mounting.
12.d
7.1
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using a rigid 6” duct.
• Install the damper 10 ø 6”.
Fix the duct in position using sufficient pipe clamps (not sup-
plied).
10
DUCTLESS VERSION AIR OUTLET
• Put connection 15 into the connection support 7.3.
Fix to the support using the 2 screws 12e supplied
Connect the air outlet connection 15 to the hood body outlet
using either a rigid ø 6” pipe(not supplied).
Ensure that the activated charcoal filters have been inserted.
15
12e
EN
1
0
10
ELECTRICAL CONNECTION
Remove the cover from the Field Wiring Compartment with a
phillips screwdriver.
Feed the Power Supply Cable through the electrical knockout.
Connect the Power Supply Cable to the range- hood cable. At-
tach the Power Supply Cable grounding lead to the green screw
provided. Attach the White lead of the power supply to the
White lead of the rangehood with a twist-on type wire connec-
tor. Attach the Black lead of the power supply to the Black
lead of the rangehood with a twist-on type wire connector.
Replace the cover.
Chimney assembly
Upper exhaust Chimney
Slightly widen the two sides of the upper flue and hook them
behind the brackets 7.3 and 7.2.1, making sure that they are
well seated.
Secure the sides to the brackets using the 4 screws 12c sup-
plied.
Make sure that the air outlet connection is aligned with the
chimney outlets.
Lower exhaust Chimney
Slightly widen the two sides of the chimney and hook them
between the upper chimney and the wall, making sure that they
are well seated.
Fix the lower part laterally to the hood body using the 2 screws
12c supplied.
12c
12c
12c
2.1
2.2
2
Power supply cable
Green
Ground
screw
Ground wire
EN
1
1
11
USE
S
V1V1V1V1V1V1V1V1V1V1V1V1V1V1V1V1V1V1
V2
V3
L
Control board
L Light Switches the lighting system on and off.
S Led Motor running led.
V1 Motor Switches the extractor motor on and off at low speed. Used to provide a
contin-uos and silent air change in the presence of light cooking vapours.
V2 Speed Medium speed, suitable for most operating conditions given the optimum
treated air flox/noise level ratio.
V3 Intensive Maximum speed, used for eliminating the highest cooking vapour emission,
including long periods.
EN
1
2
12
CARE
Metal Grease filters
CLEANING METAL SELF- SUPPORTING GREASE FILTERS
The filters must be cleaned every 2 months of operation, or
more frequently for particularly heavy usage, and can be
washed in a dishwasher.
Remove the filters one by one by pushing them backwards and
pulling them down contemporaneously.
Wash the filters. Pay attention not to bend them. Make sure
that filters are completely dry before putting them into their
seat. (a possible modification of the filter surface doesn’t influ-
ence its efficiency).
Place the filters again into their seats and make sure that the
handle of the filter remain outside.
Activated charcoal filter (Ductless version)
These filters are not washable and cannot be regenerated, and
must be replaced approximately every 4 months of operation, or
more frequently with heavy usage.
REPLACING THE ACTIVATED CHARCOAL FILTER
Remove the metal grease filters
Remove the saturated activated charcoal filter as shown (A).
Fit the new filters (B).
Replace the metal grease filters.
A
B
Lighting
LIGHT REPLACEMENT
20 W halogen light.
Remove the 2 screws fixing the Lighting support, and pull it
out of from the Hood.
Extract the lamp from the Support.
Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
• Replace the Support, fixing it in place with the two screws re-
moved as above.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Franke Consumer Products FDL 304 W User manual

Category
Cooker hoods
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI