Dormakaba RCI 972 All-in-One Illuminated Installation guide

  • Hello! I've reviewed the installation instructions for the dormakaba RCI 972TD Illuminated Pushbutton. This document provides detailed guidance on setting up the device, including wiring, changing the LED, and replacing the message tag. The device features an integrated timer and can operate with 12 or 24 VDC power. I'm here to help if you have any questions about this product.
  • What kind of back box is required for installation?
    What voltage is required for operation?
    How can I change the message tag?
    Is the timer constantly powered?
INSTALLATION
RCI 972TD
ILLUMINATED PUSHBUTTONS WITH INTEGRATED TIMER
© 2018 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: [email protected]IS972TD
PCN18041
R11-18TG
Switch Rating
Cycle Rating: 10,000
Contacts Rated 16 amps @ 125VAC
LAMP HOLDER NC Connection
NOT Required
NO TERMINAL
(WHITE)
COM TERMINAL
(WHITE)
LAMP TERMINAL
EACH SIDE
(RED + and Black –)
LED CLUSTER
BUTTON HOUSING
LENS CAP 2" LENS CAP
MESSAGE – 2" SQUARE TAG
Instruction
A 2-1/4” (57mm) deep back box is required. Match your message color with lens cap color and snap into the housing.
Timer and pushbutton connections are already wired as shown.
To change the LED voltage, slightly turn the white lamp holder in a counterclockwise direction to release from the black
housing and pull it out. Change LED cluster as desired and re-turn the lamp holder back into place.
NOTE: If LED doesn’t light, reverse bulb in socket.
Connect appropriate 12 or 24 VDC supply voltage to the red (+) and black (–) harness leads.
NOTE: Overheated / melted components caused by incorrect input voltage will not be covered under warranty.
To change the message tag, remove the lamp holder as described above and then pinch the white tabs to release the
lens cap. Be careful not to lose the spring. Insert your thumbnail between the corner of the lens cap and white
extension and then slide it along the edge to separate the cap. Tap the cap to remove the message tag.
Power Requirements
Bulb Voltage LED Current Draw
LED 12VDC 20mA
LED 24VDC 10mA
© 2018 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: [email protected]
Typical Installation for 972-TD30A ADJUSTABLE RELOCK TIMER with Fail Secure Strikes
The intergrated timer is adjustable from 0.1 - 30 seconds
Typical Installation for 972-TD30 FIXED RELOCK TIMER with Electromagnetic Lock
for Access Controlled Egress Doors with 30 Second Minimum Unlock Requirement
Both timers are powered continuously
Voltage for both timers is 12 to 24 VDC
Each push on exit button will restart the delay period.
The trigger is connected to a N/O push button
Double sided tape is provided to position the timer
inside the switch junction box.
Timer SPDT relay rating 2Amp@30VDC
12 or 24 VDC INPUT
Light -
Light +
Red +DC
Black -DC
White Trigger
White
TD-30
Brown N/O
C
12 or 24 VDC Input
N/C+
Yellow N/C
COM
Blue COM
N/C
N/O
12 or 24 VDC INPUT
Red +DC FACTORY WIRED
FACTORY WIRED
FIELD WIRING
FIELD WIRING
Black -DC
TD-30A
Blue
COM
Brown N/O
Yellow N/C
N/O
N/C
COM
White Trigger
White
Light +
Light -
NOTE: Both timers are powered continuously.
The trigger is connected to a N/O push button.
Voltage for both timers is 12 to 24 VDC.
Double sided tape is provided to position the timer inside the switch junction box.
Each push on exit button will restart the delay period.
PUSH
TO
EXIT
PUSH
TO
EXIT
with Fire Panel
connection as
required by code
Access
Control Relay
(ie. Keypad)
12 or 24 VDC INPUT
Light -
Light +
Red +DC
Black -DC
White Trigger
White
TD-30
Brown N/O
C
12 or 24 VDC Input
N/C+
Yellow N/C
COM
Blue COM
N/C
N/O
12 or 24 VDC INPUT
Red +DC FACTORY WIRED
FACTORY WIRED
FIELD WIRING
FIELD WIRING
Black -DC
TD-30A
Blue
COM
Brown N/O
Yellow N/C
N/O
N/C
COM
White Trigger
White
Light +
Light -
NOTE: Both timers are powered continuously.
The trigger is connected to a N/O push button.
Voltage for both timers is 12 to 24 VDC.
Double sided tape is provided to position the timer inside the switch junction box.
Each push on exit button will restart the delay period.
PUSH
TO
EXIT
PUSH
TO
EXIT
with Fire Panel
connection as
required by code
Access
Control Relay
(ie. Keypad)
NOTE: Connect to + and – per electromagnetic lock instructions
+ Power For Strike
/