LIST OF FIGURES
FIGURE TITLE PAGE
vi BOP 2X-DG SERIES 090123
1-1 BOP 2X-DG Series 200W, 400W Dual Channel Power Supply.................................................................... x
1-2 BOP Channel Output Characteristic........................................................................................................... 1-9
1-3 BOP Output WaveForms with Phase Shift................................................................................................. 1-9
1-4 Mechanical Outline Drawing, (BOP 2X-DG Series Models)....................................................................... 2-17
2-1 BOP 2X-DG Controls and Indicators, Front Panel ..................................................................................... 2-2
2-2 BOP 2X-DG Terminations and Controls, Rear Panel................................................................................. 2-3
2-3 A-C Source Voltage Selection, Each Channel........................................................................................... 2-3
2-4 Setting the GPIB Address .......................................................................................................................... 2-5
2-5 Slide Installation on BOP 2X-DG Units ...................................................................................................... 2-9
2-6 Load Connection (Channel 1, Typ.) Using Local Sensing.......................................................................... 2-12
2-7 Load Connection Using Remote Sensing .................................................................................................. 2-12
3-1 BOP Basic Voltage Control Loop (Local Sensing) ..................................................................................... 3-5
3-2 BOP Basic (±) Current Limiting Circuit (Local Sensing)............................................................................. 3-5
3-3 BOP BASIC Current Control (Local Sensing) ............................................................................................ 3-6
3-4 BOP BASIC (±) Voltage Limiting Circuit (Local Sensing)........................................................................... 3-6
3-5 Remote Potentiometer Control of D-C Output Voltage .............................................................................. 3-7
3-6 Remote D-C Output Voltage Control Using Two-Terminal Resistance (Decade)...................................... 3-8
3-7 External Digital Control of the D-C Output Voltage.................................................................................... 3-9
3-8 D-C Output Voltage Control with Non-inverting Configuration and High Impedance ±1V Signal Source .. 3-10
3-9 Graphs Of Possible Input/output Waveshapes .......................................................................................... 3-11
3-10 Basic Programming Circuit for Use of BOP as Bipolar Amplifier (Voltage Mode)...................................... 3-12
3-11 Programming Circuit for Driving Output Voltage with ±1V Input Programming Voltage............................. 3-13
3-12 Symmetrical Remote Control of the Current Limits.................................................................................... 3-14
3-13 Independent Remote Control of + IO and – IO Limits................................................................................. 3-14
3-14 Remote Potentiometer Control of the BOP Output Current ....................................................................... 3-15
3-15 Remote D-C Output Current Control Using Two-Terminal Resistance (Decade) ...................................... 3-16
3-16 Digital Control of Output Current................................................................................................................ 3-17
3-17 BOP Output Current Control with Non-inverting Configuration
and High Impedance (±)1 Volt Signal Source ........................................................................................ 3-17
3-18 Basic Programming Circuit for BOP as Bipolar Current-stabilized Amplifier.............................................. 3-18
3-19 Programming Circuit for Driving Output Current with ±1V Input Programming Voltage............................. 3-18
3-20 Programming Circuit for Driving Output Current with a High Impedance Source ...................................... 3-19
3-21 Symmetrical Remote Control of Voltage Limit............................................................................................ 3-20
3-22 Independent Remote Control of +EO and –EO Voltage Limit..................................................................... 3-20
3-23 Programming Example to Verify Previous Command has Completed....................................................... 3-24
3-24 RS 232 Implementation.............................................................................................................................. 3-28
3-25 Tree Diagram of SCPI Commands Used with BIT 4886 Interface Card .................................................... 3-32
3-26 Message Structure..................................................................................................................................... 3-34
3-27 Typical Example of Interface Card Program Using SCPI Commands ....................................................... 3-39
3-28 Series Connection, Voltage Mode (shown), Master/Slave with Digital Control
of Master, Remote Error Sensing, Slave BIT CARD Disabled ................................................................ 3-50
3-29 Circuit Breaker Control Circuit, Simplified Diagram.................................................................................... 3-52
3-30 Parallel Connection, Voltage Mode (shown) Master/Slave with Digital
Control of Master, Remote Error Sensing, Slave BIT CARD Disabled.................................................... 3-54
3-31 Simplified Schematic Diagram, Channel 1 or 2, BOP 2X SERIES............................................................. 3-55
3-32 PC 15/PC 12 Rear Programming Connector Interconnections.................................................................. 3-57
4-1 Locations of Adjustment and Calibration Controls ..................................................................................... 4-2
4-2 Current Shunt Connections........................................................................................................................ 4-3
4-3 BOP 2X-DG Power Supply, Top View, Cover Removed, R316 Location .................................................. 4-8
4-4 Manual Calibration Controls (Top View)..................................................................................................... 4-13
4-5 Input VISA Resource Descriptor ................................................................................................................ 4-17
4-6 Main Control Panel, Typical for BOP 2X20-10DG, Channel 2................................................................... 4-17
4-7 Calibration Controls.................................................................................................................................... 4-18
4-8 Password Entry.......................................................................................................................................... 4-19
4-9 Voltage Calibration..................................................................................................................................... 4-19
A-1 IEEE 488 Commands................................................................................................................................. A-3
B-1 Using Calibration Commands and Queries................................................................................................ B-3