  • Hello! I am an AI chatbot trained to assist you with the AEC ILLUMINAZIONE ITALO 2 URBAN TP Mounting And Maintenance Instruction. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ITALO 2_URBAN_TP_IM_ENG - Rev.04 of 27/10/14 Page 1 of 4
MOUNTING AND MAINTENANCE
INSTRUCTION
MOUNTING AND MAINTENANCE
TP mounting
ITALO 2 URBAN TP is provided with post-top attachment for
tenon with diameter of 60mm / 2-3/8" (Pic. 1).
Mount the fixture as indicated on Pic. 1.
M8 / 5/16 set screws
Hex key: 4mm / 5/32"
Twisting moment: 8Nm
Pic. 6
A
Electrical parts
Remove the cover as per instructions on Pic. 2 to Pic. 5.
To gain access to the electrical components, release the latch (A – Pic.
6) and lift the upper frame until the hinge is locked (Pic. 7).
Pic. 1
Pic. 2
Release the set screw of
the bracket
Pic. 3
Remove the
cover
Pic. 5
Put the cover back on and
fasten by set screw
(B).
Hinge
Pic. 7
Pic. 4
Pass the cable through the bracket, and
then through the cable gland or the
membrane.
B
ITALO 2_URBAN_TP_IM_ENG - Rev.04 of 27/10/14 Page 2 of 4
MOUNTING AND MAINTENANCE
INSTRUCTION
Pic. 8 Pic. 9
Tighten the screws until the cable is
firmly secured
Plastic M20 cable gland
Adjustable wrench: 24mm
Twisting moment: 3.5Nm
-------------------------------------------------
Plastic M25 cable gland
Adjustable wrench: 30mm
Twisting moment: 5Nm
CABLE GLAND MEMBRANE
Electrical line connection
- Luminaire with cable gland: follow the instr
uctions as per Pic. 8. You must secure the external cable by tightening
plastic holder on the "on-load switch".
- Luminaire with membrane: follow the instructions
as per Pic. 9. You must secure the external cable by tightening
plastic holder on the "on-load switch".
In c
ase the luminaire is equipped with PLM device, before closing the luminaire, annotate the serial number of the device.
C
C
CLASS I
CLASS II
C
A
B
A
B
C
D
D
Cable gland Membrane
A
6 ÷7 mm / 1/4"
6 ÷7 mm / 1/4"
B
< 25m / 1" < 25mm / 1"
C
M20: 8 ÷12mm / .31"÷.47"
M25: 10 ÷ 17mm / .39"÷.67"
8 ÷ 12mm / .31"÷.47"
D
2.5mmq / 12AWG
2.5mmq / 12AWG
ITALO 2_URBAN_TP_IM_ENG - Rev.04 of 27/10/14 Page 3 of 4
MOUNTING AND MAINTENANCE
INSTRUCTION
Luminaire closure
To c
lose the luminaire, follow the instructions from Pic. 10 to Pic. 12.
Pic. 10 Pic. 11 Pic. 12
Lift the upper frame
Unlock the hinge and move down the
upper frame
Locked position
LED module removal
1) Disconnect the LED
connector (C);
2) Loosen the screws (E);
3)
Remove th
e LED
module.
LED module
repositioning
1)
Pu
t the LED modules
back to the original
position
2) Tighten the sc
rews (E);
3) Connect the LED
connector (C).
Gear tray removal
1)
Disconnect the main
feed connector (B);
2) Disconnect the LED
connector (C);
3) Loosen the screws (D);
4)
Remove the gear tray.
Gear tray repositioning
1) Replace in
the original
position the gear tray
;
2) Tighten the screws (D);
3)
Connect the LED connector
(C);
4) Connect the
main feed
connector (B).
C
E
D B
SPD MAINTENANCE
The protection device is equipped with system that excludes power supply at the end of life of the luminaire.
If the luminair
es switches-off when the system is still fed, the activity of the protection device should be checked looking at signaling
LED.
To check this, use the appropriate tool and ask the manufacturer for instructions
LED ON _ Right functioning of the SPD LED OFF _ End of life SPD, replace the SPD
ITALO 2_URBAN_TP_IM_ENG - Rev.04 of 27/10/14 Page 4 of 4
MOUNTING AND MAINTENANCE
INSTRUCTION
NOTE
a) The luminaire can be installed close to flammable surfaces.
b) Class II luminaires must be installed in such a way that it is impossible for any exposed metal part to come in contact with electrical
components.
c)
The device has developed in compliance with the current standards; it is necessary that the installation is done properly, according with the
instructions supplied.
d)
The present instruction paper has to be kept for any future maintenance operation on the luminaire. Non compliance with the above will
automatically release AEC Illumination from any responsibility and the warranty will be voided
ITALO 2 URBAN
luminaire is classified
under “EXEMPT
GROUP” according
to photobiologycal
safety standard
IEC/EN 62471.
NO RISK
for the operators and
end users.
The crossed-out wastebasket symbol on the appliance means that at the end of its useful lifespan, the product must be disposed of separately
from ordinary household wastes. The user
is responsible for delivering the appliance to an appropriate collection facility at the end of its useful
lifespan. Appropriate separate collection to permit recycling, treatment and environmentally compatible disposal helps prevent negative impact
on the environment and human health and promotes recycling of the materials making up the product. For more information on available
collection facilities, contact your local waste collection service.
F
Fuse 11
0Vac 10A (provide the fuse externally if not supplied with the luminaire)
PD
Protection device
CN
Connector
PSU
Power Supply
S
On-load switch
CD
Control device
ITALO 2 URBAN 1-2M
1
0.1 ÷ 10.7kg / 23.6 Lbs
ITALO 2 URBAN 3-4M
1
0.5 ÷ 11.1kg / 24.5 Lbs
ITALO 2 URBAN 5M-8M 11.0 ÷ 11.5kg / 25.4 Lb
s
Protection grounding
(only in class I)
L
N
LED
modules
CN2
PSU
WIRING SCHEME
S1
PD
F1
(
o
p
tion
)
L
N
PLM WIRING SCHEME
Protection grounding
(only in class I)
CN1
LED
modules
CN2
PSU
S1
PD
F1
(
o
p
tion
)
CN1
CD
Side area: 0.64 Sq.f / 0.06m
2
Base area: 2.69
Sq.f / 0.25m
2
Form factor:
1.2
Ta 35°C / 95F
Use
Indoor / Outdoor
Max height
of installation: 15
m / 50'F
/