ENFORCER ST-LA108-TPQ Owner's manual

Category
Power adapters & inverters
Type
Owner's manual

This manual is also suitable for

ENFORCER Power Converters
4 SECO-LARM U.S.A., Inc.
Specifications:
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
PITSW1
Order part # 764-509%
MiST-LA1xx-TxQ_1405.docx
NOTICE:
The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to
change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in
part, without the written permission of SECO-LARM.
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited
to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect,
repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that
such equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at
SECO-LARM option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal
or property damages of any kind to the purchaser or anyone else.
WARNING:
Incorrect installation which leads to exposure to rain or moisture inside the enclosure could cause a dangerous
electric shock, damage the device, and void the warranty,
Website: www.seco-larm.com
E-mail: sales@seco-larm.com
Model ST-LA108-TPQ ST-LA115-TPQ ST-LA130-TTQ
Input
connector
Terminal block
Output
connector
2.1mm DC Plug Terminal block
Input
voltage
16~28 VAC/VDC 18~28 VAC/VDC
18~24 VAC/VDC for 12VDC
24~28 VAC or 26~28VDC for 24VDC
Output
voltage
12VDC
12/24 VDC
Output
current
0.8A 1.5A
3A@12VDC
1.5A@24VDC
LED
Indicators
Green: Power input
Green: Power input
Red: 12VDC Power output
Blue: 24VDC Power output
Current
protection
Built-in 3A PTC Fuse
Overheat
protection
Built-in
Overload
protection
Built-in
Dimensions
1
15
/
16
”x1
7
/
16
”x
15
/
16
(50x37x24 mm)
2
1
/
2
”x1
7
/
8
”x
15
/
16
(64x48x24 mm)
Model
S
Input
voltage
Output
voltage
Output
current
P
o
In
s
S
T-LA108-TPQ
16~28 VAC/VDC
12V
D
0.8A
ST-LA108-T
P
ST-LA115-T
P
wer Co
tallation
ST-LA115-TPQ
18~28 VAC/VDC
D
C
1.5A
P
Q
P
Q
n
verters
Manual
ST-LA1
18~24 VAC/V
D
24~28 VAC or 26~
2
12/24
3A
@
1
1.5A
@2
ST-LA13
30-TTQ
D
C for 12VDC
2
8 VDC for 24VDC
VDC
2VDC
2
4VDC
0-TTQ
ENFORCER
P
2
Three models
Built-in overlo
a
Re
g
ulated an
d
Green LED in
d
Red and Blue
L
ST-LA108-TP
Q
quick installati
o
Introductio
n
Dimension
s
The ENFORCE
R
converters, conv
e
useful for DC C
C
low-voltage DC
o
Features:
Overview:
With cover
S
T
-LA10
8
-TP
Q
a
1
7
/
16
(37mm
)
Cable length (i
n
S
T
-LA10
8
-TP
Q
a
Front
Mounting
tabs
ower Converter
available, providin
a
d protection
d
filtered output
d
icates power input
EDs indicate powe
Q
and ST-LA115-T
P
o
ns
n
:
s
:
Power Converter s
e
rtin
g
low-volta
g
e A
C
TV cameras, acces
o
utput is required.
Without cover
2.1mm
DC Plug
(Output)
Te
a
nd S
T
-LA115-TP
Q
1
15
/
16
(50mm)
)
cluding DC plug): 4” (10
15
/
16
(24mm
)
a
n
d
S
T
-LA115-TP
Q
Side
s
v
ar
y
in
g
de
g
rees of l
o
r
output
(
ST-LA130-
T
P
Q Onl
y
: 2.1mm DC
ries is a famil
of lo
or DC into re
ulate
controls, and man
Wi
t
rminal block
(Input)
Input LED
2
mm)
)
S
T
-
S
T
-
SECO
o
w-volta
g
e DC outpu
t
T
TQ onl
y)
Plu
with pi
tail for
w
-voltage step-down
DC outputs. Thes
other applications w
t
h cover
W
Output
termi
n
block (blac
k
In
p
(bl
u
Output
LED
2
(6
4
1
7
/
8
(48mm)
T
-
LA13
0
-TT
Q
-
LA13
0
-TT
Q
Front
-LARM U.S.A., I
n
t
s
imple and
power
e
converters are
h
ere regulated
W
ithout cover
n
al
k
)
p
ut terminal block
u
e, non-polarized)
Potentiometer
Mini jum
2
1
/
2
4
mm)
15
/
16
(24mm)
Side
Input
LED
n
c.
per
ENFORCER Power Converters
SECO-LARM U.S.A., Inc. 3
1. Remove the cover by removing the screws on the back of the unit with a screwdriver
(not included).
2. Set the desired voltage output via the on-board mini jumper, see illustration below.
3. Connect the power supply to the blue input terminal block. Polarity is not important.
For 12VDC output, connect an 18~24 VAC/VDC power supply.
For 24VDC output, connect a 24~28 VAC or 26~28 VDC power supply.
Note: Do not turn on the power supply until ready to test.
Note: Use between 16AWG and 22AWG wire for the input.
4. Turn the power supply on. The ST-LA130-TTQ’s green LED should turn on to indicate input
power. The red LED should light to indicate 12VDC power output while the blue LED should light
to indicate 24VDC power output.
5. Test the output.
Use a voltage meter to measure the output from the black output terminal
block to make sure it is correct.
Note: The output voltage can be adjusted by about 10% by turning the on-board potentiometer.
Turn clockwise to increase the voltage, turn counterclockwise to decrease the voltage.
Range: 12~13.3 VDC at 12VDC output, 24~26.8 VDC at 24VDC output.
6. Connect the device requiring power to the black output terminal block. Observe correct polarity.
7. Test the device to ensure proper operation.
8. Replace the plastic cover on the voltage converter and secure it in the desired location.
Installation
1. Remove the cover by simultaneously pressing the two indented slots located on both sides
of the unit.
2. Connect power to the input side terminal block. Polarity is not important.
For the ST-LA108-TPQ, connect a 16~24 VAC/VDC power supply.
For the ST-LA115-TPQ, connect an 18~24 VAC/VDC power supply.
Note: Do not turn on the power supply until ready to test.
Note: Use between 16AWG and 22AWG wire for the input.
3. Turn the power supply on. The power converter’s green LED should turn on to indicate
input power.
4. Test the output.
Use a voltage meter to measure the output from the DC plug to make
sure it is correct.
5. Connect the device requiring power to the DC plug.
6. Test the device to ensure proper operation.
7. Replace the plastic cover on the voltage converter and secure it in the desired location.
S
T
-LA10
8
-TP
Q
and S
T
-LA115-TP
Q
S
T
-LA13
0
-TT
Q
24V 12
V
Mini jumper voltage selector
24V 12
V
12VDC or 24VDC
  • Page 1 1
  • Page 2 2

ENFORCER ST-LA108-TPQ Owner's manual

Category
Power adapters & inverters
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI