Samsung AC140NN4SEC User manual

Type
User manual

This manual is also suitable for

Air conditioner
User&Installation manual
AC∗∗∗NN4SEC
Thank you for purchasing this Samsung air conditioner.
Before operating this unit, please read this manual carefully and retain it for future reference.
DB68-07418A-01
AA
2
English
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset,
USB cable) should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle
them responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of
where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic
accessories should not be mixed with other commercial wastes for disposal.
Safety precautions ............................................................ 3
Checking before use ........................................................ 8
Viewing the parts ........................................................... 10
Cleaning and maintaining the air conditioner .......... 11
Troubleshooting .............................................................. 14
Cool Summer Offer
On those hot sweltering summer days and long restless
nights, there is no better escape from the heat than
the cool comforts of home. Your new air conditioner
brings an end to exhausting hot summer days and lets
you rest.
This summer, beat the heat with your own air
conditioner.
Look for Everywhere
The elegant and harmonious design gives priority to
the aesthetics of your space and complements any
of your existing interior decor. With its soft color and
rounded-edge shape, the new air conditioner adds class
to any room. Enjoy what your air conditioner offers both
functionally and esthetically.
Compact and easy-to-use cassette type
Designed to be installed into most types of suspended
ceiling, the cassette type air conditioner is ideal for
business and commercial accommodations.
Fresh cool/warm air can be provided through the
controllable 1, 2 or 4 sides of the unit.
All functions of the air conditioner will be controlled
easily via a remote control.
Features of your new air conditioner
Contents
Safety precautions .......................................................... 15
Preparation for installation .......................................... 17
Deciding on where to install the indoor unit ...........18
Indoor unit installation ..................................................21
Purging the unit ..............................................................22
Connecting the refrigerant pipe ................................ 22
Cutting/Flaring the pipes ............................................ 23
Performing leak test & insulation ............................. 24
Drainpipe and drain hose installation ...................... 26
Connecting the connection cord ................................ 28
Extending the power cable .......................................... 29
Setting an indoor unit address and installation option ...31
Troubleshooting ............................................................. 37
USING PARTS
INSTALLATION PARTS
AA
ENGLISH
3
English
Safety precautions
USING PARTS
Before using your new air conditioner, please read this manual thoroughly to ensure that you know
how to safely and efciently operate the extensive features and functions of your new appliance.
Because the following operating instructions cover various models, the characteristics of your air
conditioner may differ slightly from those described in this manual. If you have any questions, call
your nearest contact center or nd help and information online at www.samsung.com.
Important safety symbols and precautions:
WARNING
Hazards or unsafe practices that may result in severe personal injury or
death.
CAUTION
Hazards or unsafe practices that may result in minor personal injury or
property damage.
Follow directions.
Do NOT attempt.
Make sure the machine is grounded to prevent electric shock.
Unplug the power plug from the wall socket.
Do NOT disassemble.
FOR INSTALLATION
WARNING
Use the power line with the power specications of the product or higher and use the power
line for this appliance only. In addition, do not use an extension line.
Extending the power line may result in electric shock or re.
Do not use an electric transformer. It may result in electric shock or re.
If the voltage/frequency/rated current condition is different, it may cause re.
The installation of this appliance must be performed by a qualied technician or service
company.
Failing to do so may result in electric shock, re, explosion, problems with the product, or
injury.
Install a switch and circuit breaker dedicated to the air conditioner.
Failing to do so may result in electric shock or re.
Fix the outdoor unit rmly so that the electric part of the outdoor unit is not exposed.
Failing to do so may result in electric shock or re.
Do not install this appliance near a heater, inammable material. Do not install this
appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water
(rain drops). Do not install this appliance in a location where gas may leak.
This may result in electric shock or re.
Never install the outdoor unit in a location such as on a high external wall where it could fall.
If the outdoor unit falls, it may result in injury, death or property damage.
AA
4
English
Safety precautions
This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic
water pipe, or telephone line.
Failure to do so may result in electric shock, re, an explosion, or other problems with the
product.
Never plug the power cord into a socket that is not grounded correctly and make sure that
it is in accordance with local and national codes.
FOR INSTALLATION
CAUTION
Install your appliance on a level and hard oor that can support its weight.
Failing to do so may result in abnormal vibrations, noise, or problems with the product.
FOR POWER SUPPLY
WARNING
When the circuit breaker is damaged, contact your nearest service center.
Do not pull or excessively bend the power line. Do not twist or tie the power line. Do not hook
the power line over a metal object, place a heavy object on the power line, insert the power
line between objects, or push the power line into the space behind the appliance.
This may result in electric shock or re.
FOR POWER SUPPLY
CAUTION
When not using the air conditioner for a long period of time or during a thunder/lightning
storm, cut the power at the circuit breaker.
Failing to do so may result in electric shock or re.
FOR USING
WARNING
If the appliance is ooded, please contact your nearest service center.
Failing to do so may result in electric shock or re.
If the appliance generates a strange noise, a burning smell or smoke, unplug the power plug
immediately and contact your nearest service center.
Failing to do so may result in electric shock or re.
In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate immediately without
touching the power line.
Do not touch the appliance or power line.
Do not use a ventilating fan.
A spark may result in an explosion or re.
ENGLISH
5
English
To reinstall the air conditioner, please contact your nearest service center.
Failing to do so may result in problems with the product, water leakage, electric shock, or
re.
A delivery service for the product is not provided. If you reinstall the product in another
location, additional construction expenses and an installation fee will be charged.
Especially, when you wish to install the product in an unusual location such as in an
industrial area or near the seaside where it is exposed to the salt in the air, please contact
your nearest service center.
Do not touch the circuit breaker with wet hands.
This may result in electric shock.
Do not strike or pull the air conditioner with excessive force.
This may result in re, injury, or problems with the product.
Do not place an object near the outdoor unit that allows children to climb onto the machine.
This may result in children seriously injuring themselves.
Do not turn the air conditioner off with the circuit breaker while it is operating.
Turning the air conditioner off and then on again with the circuit breaker may cause a spark
and result in electric shock or re.
After unpacking the air conditioner, keep all packaging materials well out of the reach of
children, as packaging materials can be dangerous to children.
If a child places a bag over its head, it may result in suffocation.
Do not insert your ngers or foreign substances into the outlet when the air conditioner is
operating or the front panel is closing.
Take special care that children do not injure themselves by inserting their ngers into the
product.
Do not touch the front panel with your hands or ngers during the heating operation.
This may result in electric shock or burns.
Do not insert your ngers or foreign substances into the air inlet/outlet of the air conditioner.
Take special care that children do not injure themselves by inserting their ngers into the
product.
Do not use this air conditioner for long periods of time in badly ventilated locations or near
inrm people.
Since this may be dangerous due to a lack of oxygen, open a window at least once an hour.
AA
6
English
Safety precautions
If any foreign substance such as water has entered the appliance, cut the power by
unplugging the power plug and turning the circuit breaker off and then contact your nearest
service center.
Failing to do so may result in electric shock or re.
Do not attempt to repair, disassemble, or modify the appliance yourself.
Do not use any fuse (such as cooper, steel wire, etc.)other than the standard fuse.
Failing to do so may result in electric shock, re, problems with the product, or injury.
FOR USING
CAUTION
Do not place objects or devices under the indoor unit.
Water dripping from the indoor unit may result in re or property damage.
Check that the installation frame of the outdoor unit is not broken at least once a year.
Failing to do so may result in injury, death or property damage.
Max current is measured according to IEC standard for safety and current is measured
according to ISO standard for energy efciency.
Do not stand on top of the appliance or place objects (such as laundry, lighted candles,
lighted cigarettes, dishes, chemicals, metal objects, etc.) on the appliance.
This may result in electric shock, re, problems with the product, or injury.
Do not operate the appliance with wet hands.
This may result in electric shock.
Do not spray volatile material such as insecticide onto the surface of the appliance.
As well as being harmful to humans, it may also result in electric shock, re or problems
with the product.
Do not drink the water from the air conditioner.
The water may be harmful to humans.
Do not apply a strong impact to the remote controller and do not disassemble the remote
controller.
Do not touch the pipes connected with the product.
This may result in burns or injury.
Do not use this air conditioner to preserve precision equipment, food, animals, plants or
cosmetics, or for any other unusual purposes.
This may result in property damage.
ENGLISH
7
English
Avoid directly exposing humans, animals or plants from the air ow from the air conditioner
for long periods of time.
This may result in harm to humans, animals or plants.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible
for their safety. Children should be supervised to ensure that they do not play with the
appliance.
FOR CLEANING
WARNING
Do not clean the appliance by spraying water directly onto it. Do not use benzene, thinner or
alcohol to clean the appliance.
This may result in discoloration, deformation, damage, electric shock or re.
Before cleaning or performing maintenance, unplug the air conditioner from the wall socket
and wait until the fan stops.
Failing to do so may result in electric shock or re.
FOR CLEANING
CAUTION
Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has
sharp edges.
To avoid cutting your ngers, wear thick cotton gloves when cleaning it.
Do not clean the inside of the air conditioner by yourself.
For cleaning inside the appliance, contact your nearest service center.
When cleaning the internal lter, refer to the descriptions in the ‘Cleaning and maintaining
the air conditioner section.
Failure to do may result in damage, electric shock or re.
AA
8
English
Checking before use
Operation ranges
The table below indicates the temperature and humidity ranges the air conditioner can be operated within.
Refer to the table for efcient use.
MODE
OPERATIONAL TEMPERATURE
INDOOR HUMIDITY IF OUT OF CONDITIONS
INDOOR OUTDOOR
COOLING   80% or less
Condensation may occur on the
indoor unit with risk to have either
water blow off or drops on the

DRYING   -
Maintaining your air conditioner
Internal protections via the unit control system
This internal protection operates if an internal fault occurs in the air conditioner.
Type Description
Anti-protection of
internal battery
The compressor will be off to protect internal battery when the air conditioner
operates in Cool mode.
Protect compressor
The air conditioner does not start operating immediately to protect the compressor
of the outdoor unit after it has been started.
NOTE
If the cooling operation is used at over 32˚C (indoor temperature), it does not cool at its full capacity.
ENGLISH
9
English
Tips on using air conditioner
Here are some tips that you would follow when using your air conditioner.
TOPIC RECOMMENDATION
Cooling  
may take time to bring the inner temperature to the desired coolness.
 
cool faster.
Power failure  
immediately stops and unit will be off. When power returns, the air conditioner will run
automatically.
Protection
mechanism
 
cool/warm air does not come out for 3 minutes to protect the compressor of the outdoor
unit.
Automatic air ow
blade control
 
conditioner with windows open or when small capacity indoor unit is installed and
operating in a room that is too large) indoor can become very humid when the angle of the


to make sure that performance of the product is stable.
AA
10
English
Viewing the parts
Main parts
Display


Air intake
Indicator
Remote control sensor
Timer indicator
Removing frost indicator
On/Off operation indicator
Filter reset indicator
NOTE
Your air conditioner and display may look slightly different from the illustration shown above depending on
your model.
AA
ENGLISH
11
English
Cleaning the exterior
Wipe the surface of the unit with a slightly wet or dry cloth when
needed. Wipe off dirt of odd-shaped area by using a soft brush.
Cleaning and maintaining the air conditioner
CAUTION

They may damage the surface of the air conditioner and

AA
12
English
Pull out the Air filter.
Detach the front grille.
Remove the safety clip first and then remove the
hinge. Pull the green switch on the hinge part
down and then press and pull the hinge part to
remove the grille. (There are two hinges on the
grille and you must apply this step on both of
them to remove the grille.)
If you want to clean the filter only, you do not have to
detach the grille. Follow step 4 and 5
Open the front grille.
Open the blades on the left and right side of the
Samsung logo. Press both of the levers and pull the
grille downward. Two safety clips are mounted to the
front grille to prevent it from dropping.
Insert the Air filter back in its original position.
You will hear a click sound when the Air filter is
properly placed.
Attach the front grille.
Reverse the above steps to attach the front grille.
Clean the grille and Air filter with a vacuum cleaner
or soft brush. If dust is too heavy, then rinse it with
running water and dry it in a ventilated area.
For best conditions, repeat every two weeks.
If the Air filter dries in a confined (or humid) area,
odors may generate. If it occurs, re-clean and dry it
in a well-ventilated area.
Cleaning air lter and grille
Cleaning and maintaining the air conditioner
NOTE
 
 Filter Reset
schedule. Filter sign indicator will be on for cleaning time.
 
maintenance, you must turn off the circuit breaker and turn it on again before using the air conditioner.
Otherwise, angles of the each angle can be different or some of the blade may not close when the product is off.
ENGLISH
13
English
If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best
condition.
Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug.
There may be internal damage if moisture is left in components.
Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode
for 3 to 4 hours. This helps remove odors which may have generated from dampness.
Periodical checks
Refer to the following chart to maintain the air conditioner properly.
Type Description Monthly
Every 4
months
Once a year
Indoor unit

Clean the condensate drain pan (2)
Thoroughly clean the heat exchanger (2)
Clean the condensate drain pipe (2)
Replace the remote control batteries (1)
Outdoor unit
Clean the heat exchanger on the outside of the unit (2)
Clean the heat exchanger on the inside of the unit (2)
Clean the electric components with jets of air (2)

Clean the fan (2)

Clean the condensate drain pan (2)
: This check mark requires checking the indoor/outdoor unit periodically, following to the description to maintain the
air conditioner properly.
NOTE
(1) The described operations should be performed more frequently if the area of installation is very dusty.

installation part in the manual.
AA
14
English
Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.
PROBLEM SOLUTION
The air conditioner does
not operate immediately
after it has been restarted.
 
immediately to keep the unit from overloading.
The air conditioner will start in 3 minutes.
The air conditioner does
not work at all.
 
socket correctly.
 
 
 
The temperature does not
change.
 
Press the Mode button on the remote control to select another mode.
The cool air does not come
out of the air conditioner.
 
the Temperature button on the remote control to change the set temperature. Press
the Temperature button to decrease or increase the temperature.
 
 
does not come out to protect the compressor of the outdoor unit.
 

 
 
 
 
The fan speed does not
change.
 
The air conditioner automatically adjusts the fan speed to Auto in Auto/Dry mode.
Timer function does not set.  Power button on the remote control after you have set the time.
Odors permeate in the
room during operation.
 
outside. Operate the air conditioner in Fan mode or open the windows to air out the
room.
The air conditioner makes a
bubbling sound.
 
compressor. Let the air conditioner operate in a selected mode.
 Power button on the remote control, noise may be heard from
the drain pump inside the air conditioner.
Water is dripping from the
air ow blades.
 

difference in temperature.
Remote control is not
working.
 
 
 
 

The air conditioner does
not turn on or off with the
wired remote control.
 
The wired remote control
does not operate.
 
unit and switch off the circuit breaker. Call your nearest contact center.
The indicators of the digital
display ashes.
 Power button on the remote control to turn the unit off and switch the
circuit breaker off. Then, switch it on again.
Troubleshooting
AA
ENGLISH
15
English
Safety precautions
INSTALLATION PARTS
Carefully follow the precautions listed below because they are essential to guarantee the safety of
the equipment.
Always disconnect the air conditioner from the power supply before
servicing it or accessing its internal components.
Verify that installation and testing operations are performed by qualified
personnel.
Verify that the air conditioner is not installed in an easily accessible area.
General information

Carefully read the content of this manual before installing the air conditioner and store the
manual in a safe place in order to be able to use it as reference after installation.
For maximum safety, installers should always carefully read the following warnings.
Store the operation and installation manual in a safe location and remember to hand it over to
the new owner if the air conditioner is sold or transferred.
This manual explains how to install an indoor unit with a split system with two SAMSUNG
units. The use of other types of units with different control systems may damage the units
and invalidate the warranty. The manufacturer shall not be responsible for damages arising
from the use of non compliant units.
The manufacturer shall not be responsible for damage originating from unauthorized
changes or the improper connection of electric and requirements set forth in the “Operating
limits table, included in the manual, shall immediately invalidate the warranty.
The air conditioner should be used only for the applications for which it has been designed:
the indoor unit is not suitable to be installed in areas used for laundry.
Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from
the power supply.
In order to prevent electric shocks, res or injuries, always stop the unit, disable the protection
switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power
cable is hot or damaged or if the unit is very noisy.
Always remember to inspect the unit, electric connections, refrigerant tubes and protections
regularly. These operations should be performed by qualied personnel only.
The unit contains moving parts, which should always be kept out of the reach of children.
Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized
personnel, these operations may cause electric shocks or res.
Do not place containers with liquids or other objects on the unit.
All the materials used for the manufacture and packaging of the air conditioner are
recyclable.
The packing material and exhaust batteries of the remote controller(optional) must be
disposed of in accordance with current laws.
The air conditioner contains a refrigerant that has to be disposed of as special waste. At the
end of its life cycle, the air conditioner must be disposed of in authorized centers or returned
to the retailer so that it can be disposed of correctly and safely.
WARNING
AA
16
English
Installing the unit
IMPORTANT: When installing the unit, always remember to connect rst the refrigerant tubes, then
the electrical lines.
Always disassemble the electric lines before the refrigerant tubes.

Upon receipt, inspect the product to verify that it has not been damaged during transport. If
the product appears damaged, DO NOT INSTALL it and immediately report the damage to the
carrier or retailer (if the installer or the authorized technician has collected the material from
the retailer.)

After completing the installation, always carry out a functional test and provide the
instructions on how to operate the air conditioner to the user.

Do not use the air conditioner in environments with hazardous substances or close to
equipment that release free ames to avoid the occurrence of res, explosions or injuries.

Our units should be installed in compliance with the spaces shown in the installation
manual, to ensure accessibility from both sides and allow repairs or maintenance operations
to be carried out. The unit’s components should be accessible and easy to disassemble
without endangering people and objects.
For this reason, when provisions of the installation manual are not complied with, the cost
required to access and repair the units (in SAFETY CONDITIONS, as set out in prevailing
regulations) with harnesses, ladders, scaffolding or any other elevation system will NOT be
considered part of the warranty and will be charged to the end customer.
Power supply line, fuse or circuit breaker

Always make sure that the power supply is compliant with current safety standards. Always
install the air conditioner in compliance with current local safety standards.

Always verify that a suitable grounding connection is available.
Verify that the voltage and frequency of the power supply comply with the specications and
that the installed power is sufcient to ensure the operation of any other domestic appliance
connected to the same electric lines.
Always verify that the cut-off and protection switches are suitably dimensioned.
Verify that the air conditioner is connected to the power supply in accordance with the
instructions provided in the wiring diagram included in the manual.
Always verify that electric connections (cable entry, section of leads, protections…) are
compliant with the electric specications and with the instructions provided in the wiring
scheme. Always verify that all connections comply with the standards applicable to the
installation of air conditioners.
Devices disconnected from the power supply should be completely disconnected in the
condition of overvoltage category.
Be sure not to perform power cable modication,extension wiring, and multiple wire
connection.
- It may cause electric shock or re due to poor connection, poor insulation, or current limit
override.
- When extension wiring is required due to power line damage, refer to: Extending the power
cable" in the installation manual.
Safety precautions
ENGLISH
17
English
When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into
account.
Do NOT install the air conditioner in a location where it will come into contact with the following elements :
Combustible gases
Saline air

Sulphide gas
Special environmental conditions

Avoid installing the air conditioner :
In areas where it is exposed to direct sunlight. Close to heat sources.
In damp areas or locations where it could come into contact with water. (for example rooms used for laundry)
In areas where curtains and furniture could affect the supply and discharge of air.
Without leaving the required minimum space around the unit. (as shown in the drawing)
In scarcely ventilated areas.
On surfaces that are unable to support the weight of the unit without deforming, breaking or causing
vibrations during the use of the air conditioner.
In a position that does not enable the condensate drainage pipe to be correctly installed. (at the end of the

General
Preparation for installation
CAUTION
Make sure that you earth the cables.
- Do not connect the earth wire to the gas pipe, water pipe, lighting rod or telephone wire. If
earthing is not complete, electric shock or re may occur.
Install the circuit breaker.
- If the circuit breaker is not installed, electric shock or re may occur.
Make sure that the condensed water dripping from the drain hose runs out properly and safely.
Install the power cable and communication cable of the indoor and outdoor unit at least 1m away
from the electric appliance.
Install the indoor unit away from lighting apparatus using the ballast.
- If you use the wireless remote control, reception error may occur due to the ballast of the
lighting apparatus.
Do not install the air conditioner in following places.
- Place where there is mineral oil or arsenic acid. Resin parts ame and the accessories may drop
or water may leak. The capacity of the heat exchanger may reduce or the air conditioner may be
out of order.
- The place where corrosive gas such as sulfurous acid gas generates from the vent pipe or air outlet.
The copper pipe or connection pipe may corrode and refrigerant may leak.
- The place where there is a machine that generates electromagnetic waves. The air conditioner
may not operate normally due to control system.
- The place where there is a danger of existing combustible gas, carbon ber or ammable dust.
The place where thinner or gasoline is handled. Gas may leak and it may cause re.
AA
18
English
The following accessories are supplied with the indoor unit.

Accessories
Pattern sheet Insulation cover
pipe A
Insulation cover
pipe B
Insulation drain Flexible hose clamp
Flexible hose Cable-tie user & installation
manual
Preparation for installation
Indoor unit
Space requirements for indoor unit
There must be no obstacles near the air inlet and outlet.
Install the indoor unit on a ceiling that can support its weight.


The indoor unit must be installed in this way, that they are out of public access. (Not touchable by the users)
1500mm or more
1500mm or more
1500mm or more
1500mm or more
CAUTION
 
27°C or humidity over 80%,you must apply extra 10mm of polyethylene foam or other
insulation with similar material on the body of the indoor unit.
Deciding on where to install the indoor unit
ENGLISH
19
English
Required space for an indoor unit installation
Obstruction
20mm
17mm
1500mm
or more
‘C’ mm
2500mm or more
Thickness: more than 10mm
Insulate the end of the pipe and some curved area by using separate insulator.
Insulate the discharge and suction part at the same time when you insulate connection duct.

∗∗052/071∗∗ ∗∗090/100/120/140∗∗
C mm 251 335
Net
dimension
mm 840x204x840 840×288×840
Indoor Unit A B C D E
∗∗052/071∗∗ 435x140
530x
140
530x
140
580x
140 830x830
∗∗090/100/120/140∗∗ 435x224
530x
224
530x
224
580x
224 830x830

from each side, either to guarantee correct operation of maintenance or repairing products.
The units parts must be reachable and removable completely under safety condition (for
people or things).
The appearance of the unit maybe different from the picture depending on the model.

You must hold the hanger plate on the corner and carry the indoor unit.
CAUTION
A C
BD
E
AA
20
English
Deciding on where to install the indoor unit
Drawing of the indoor unit
Unit : mm
Sub duct connection

∗∗052∗∗ ∗∗071∗∗ ∗∗090/100/120/140∗∗
A mm 204 288
B mm 253 337
Net dimension mm 840×204×840 840×288×840
Net weight kg 15.0 18.0
Liquid pipe connection 1/4"(6.35) 3/8"(9.52)
Gas pipe connection 1/2"(12.70) 5/8"(15.88) 5/8"(15.88)
Drain Hose connection mm 
890~910 (Celling opening)
950
735 (Suspension position)
890~910 (Celling opening)
735 (Suspension position)
55 55840
370
346
185
96
950
120
45
86
164
216
55 55840
330 240
270
300
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Samsung AC140NN4SEC User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI