Symmons 9602-P-2.0 Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

Origins
-1.5 1.5 gpm (5.7 L/min) flow restrictor
-2.0 2.0 gpm (7.6 L/min) flow restrictor
-231 Super showerhead in place of Clear-Flo
-295 Institutional showerhead in place of
Clear-Flo
-SS Slip spout on any tub/shower unit
-X Integral service stops
-CHKS Integral check stops
-IPS 1/2” female IPS connections
-REV Reverse coring for back to back
installations
-B Chrome brass escutcheon
-D Chrome brass dome cover
-VP Vandal proof escutcheon screws
-OP 13” oval plate
-L/HD Less showerhead
-TRM Trim only, valve not included
Model Numbers
Operation & Maintenance Manual
9600-P, 9601-P, 9602-P
Specification
Warranty
Limited Lifetime - to the original end purchaser in
consumer/residential installations.
5 Years - for industrial/commercial installations.
Refer to www.symmons.com/warranty for complete
warranty information.
Compliance
Certied by
CSA Group
Modifications
Note: Append appropriate -sufx to model number.
-ASME A112.18.1/CSA B125.1
-WaterSense 1.5 gpm (5.7 L/min)
2.0 gpm (7.6 L/min)
9600-P
Origins Shower Valve
9601-P
Origins Shower System
9602-P
Origins Tub/Shower System
9600-P/9601-P
Shower system powered by the Temptrol
®
Pressure
Balancing valve. Features adjustable stop screw to limit
handle turn, 1 mode showerhead with easy to clean
rubber nozzles and standard 2.5 gpm (9.5 L/min) ow
restrictor. Components made from metal and nonmetallic
materials plated in standard polished chrome nish.
9602-P
Tub/shower system powered by the Temptrol
®
Pressure
Balancing valve. Features adjustable stop screw to limit
handle turn, diverter tub spout, 1 mode showerhead with
easy to clean rubber nozzles and standard 2.5 gpm
(9.5 L/min) ow restrictor. Components made from metal
and nonmetallic materials plated in standard polished
chrome nish.
For California Residents
WARNING: This product contains chemicals known to
the State of California to cause cancer, birth defects, or
other reproductive harm.
2
Dimensions
Measurements
A 6 3/8”, 162 mm
B 3 1/2”, 89 mm
C 2 7/8”, 73 mm
D
Shower Valve Hole Size
Min. Ø 3”, 76 mm
Max. Ø 4”, 102 mm
E Ref. 77”, 1956 mm
F
Rough-in
2 3/8” ± 1/2”, 60 mm ± 13 mm
G
Ref. 32”, 813 mm
(9602-P)
Ref. 42”, 1067 mm
(9601-P, 9600-P)
H
Male 1/2” NPT tting must
protrude 4” from
nished wall
I 5 1/4”, 133 mm
J Ø 2 1/2”, 64 mm
K Ø 2 3/4”, 70 mm
L 2 1/8”, 54 mm
M Ø 5 3/4”, 146 mm
N Ø 2 1/2”, 64 mm
FLOORFLOOR
EE
GG
AA JJ
KK
CC
BB
HH
II
FF
MM
LL
DD
NN
Notes:
1) All dimensions measured from nominal rough-in (see F as reference).
2) Dimensions subject to change without notice.
3
Replacement Parts
Item Description Part Number
A Showerhead 4-141
B
C
Shower Arm &
Flange
300S
D
H
I
Handle
Assembly
RTS-061
E Dome Cover T-19
F
G
Shower
Escutcheon Kit
9600-P-ESC
J Tub Spout 054
Parts Breakdown
HOT
Water Supply
E
F
F
G
J
COLD
Water Supply
A
B
C
D
I
H
Notes:
1) Apply a bead of silicone around the perimeter of all shower
trim installed ush to the nished wall. Leave opening on
bottom of escutcheon for weep hole.
2) Apply plumber tape to all threaded connections.
3) Escutcheon artwork is dependent on handle style.
Tools Required
Adjustable wrench
Allen wrench (1/8”)
Phillips head
screwdriver
Plumber tape
Silicone
4
1
G
F
2
2) Install dome cover (E) to valve by
turning clockwise.
E
1
2
1) Install shower escutcheon (G) to
shower valve. Secure with two
screws (F).
3) Install handle (D) to valve and
secure with set screw (H). Install
plug button (I).
1
H
I
D
2
4) Install tub spout (J) to pipe tting.
Turn clockwise to secure.
1
J
2
5) Attach shower arm (B) and
ange (C) to vertical shower pipe.
Turn clockwise to tighten.
B
1
2
C
Installation
Note:
For valve body installation, please
see valve body manual.
Note:
Handle should be facing the 12
o’clock position.
6) Install showerhead (A) to shower
arm (B). Turn clockwise to tighten.
B
1
2
A
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2015 Symmons Industries, Inc. www.symmons.com [email protected] ZV-3132 REV A 110515
1) Turn shower handle counterclock-
wise approximately 1/4 turn to put
valve in cold position.
Operation (Temperature Control)
2) Turn shower handle counterclock-
wise approximately 1/2 turn to put
valve in warm position.
3) Turn shower handle counterclock-
wise approximately 3/4 turn to put
valve in hot position.
Operation (Diverter Control)
1) Diverter lever in down position for tub spout operation. 2) Diverter lever in up position for shower operation.
Troubleshooting Chart
Problem Cause Solution
Finish is spotting.
Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

Symmons 9602-P-2.0 Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI