Fujitsu AOTG30KMTC Installation guide

Type
Installation guide
En-1
1. SAFETY PRECAUTIONS
• Besuretoreadthismanualcarefullybeforeinstallation.
• Thewarningsandprecautionsindicatedinthismanualcontainimportantinformation
pertainingtoyoursafety.Besuretoobservethem.
• Handthismanual,togetherwiththeoperatingmanual,tothecustomer.Requestthe
customertokeepthemonhandforfutureuse,suchasforrelocatingorrepairingthe
unit.
WARNING
Indicatesapotentiallyorimminentlyhazardoussituationwhich,
ifnotavoided,couldresultindeathorseriousinjury.
CAUTION
Indicatesapotentiallyhazardoussituationthatmayresultin
minorormoderateinjuryordamagetoproperty.
WARNING
Toavoidgettinganelectricshock,nevertouchtheelectricalcomponentssoonafterthe
powersupplyhasbeenturnedoff.Afterturningoffthepower,alwayswait10minutesor
morebeforeyoutouchtheelectricalcomponents.
Installationofthisproductmustbedonebyexperiencedservicetechniciansor
professionalinstallersonlyinaccordancewiththismanual.Installationby
non-professionalorimproperinstallationoftheproductmaycauseseriousaccidents
suchasinjury,waterleakage,electricshock,orre.Iftheproductisinstalledin
disregardoftheinstructionsinthismanual,itwillvoidthemanufacturer’swarranty.
Donotturnonthepoweruntilallworkhasbeencompleted.Turningonthepowerbefore
theworkiscompletedcancauseseriousaccidentssuchasanelectricshockorre.
Ifrefrigerantleakswhenyouareworking,ventilatethearea.Iftheleakingrefrigerantis
exposedtoadirectame,itmayproduceatoxicgas.
Installationmustbeperformedinaccordancewithregulations,codes,orstandardsfor
electricalwiringandequipmentineachcountry,region,ortheinstallingplace.
Donotusethisequipmentwithairoranyotherunspeciedrefrigerantintherefrigerant
lines.Excesspressurecancausearupture.
Duringinstallation,makesurethattherefrigerantpipeisattachedrmlybeforeyourun
thecompressor.
Donotoperatethecompressorundertheconditionofrefrigerantpipingnotattached
properlywith3-wayvalveopen.Thismaycauseabnormalpressureintherefrigeration
cyclethatleadstobreakageandeveninjury.
Wheninstallingandrelocatingtheairconditioner,donotmixgasesotherthanthe
speciedrefrigerant(R32)toentertherefrigerantcycle.
Ifairorothergasenterstherefrigerantcycle,thepressureinsidethecyclewillriseto
anabnormallyhighvalueandcausebreakage,injury,etc.
Donotremovetheconnectionpipewhilethecompressorisinoperationwith3-way
valveopen.
Thismaycauseabnormalpressureintherefrigerationcyclethatleadstobreakageand
eveninjury.
Toconnecttheindoorandoutdoorunit,useairconditionerpipingandcablesavailable
locallyasstandardparts.Thismanualdescribesproperconnectionsusingsuch
installationset.
Donotmodifypowercable,useextensioncableorbranchwiring.Improperusemay
causeelectricshockorrebypoorconnection,insufcientinsulationorovercurrent.
Donotpurgetheairwithrefrigerantsbutuseavacuumpumptovacuumtheinstallation.
Thereisnoextrarefrigerantintheoutdoorunitforairpurging.
UseavacuumpumpforR32orR410Aexclusively.
Usingthesamevacuumpumpfordifferentrefrigerantsmaydamagethevacuumpump
ortheunit.
UseacleangaugemanifoldandcharginghoseforR32orR410Aexclusively.
Donotusemeanstoacceleratethedefrostingprocessortoclean,otherthanthose
recommendedbythemanufacturer.
Theapplianceshallbestoredinaroomwithoutcontinuouslyoperatingignitionsources
(forexample:openames,anoperatinggasapplianceoranoperatingelectricheater.
Donotpierceorburn.
Beawarethatrefrigerantsmaynotcontainanodour.
Donotmodifythisunit,suchasopeningaholeinthecabinet.
Duringthepump-downoperation,makesurethatthecompressoristurnedoffbefore
youremovetherefrigerantpiping.
Donotremovetheconnectionpipewhilethecompressorisinoperationwith3-way
valveopen.
Thismaycauseabnormalpressureintherefrigerationcyclethatleadstobreakageand
eveninjury.
Thisapplianceisnotintendedforusebypersons(includingchildren)withreduced
physical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unless
theyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebya
personresponsiblefortheirsafety.Childrenshouldbesupervisedtoensurethatthey
donotplaywiththeappliance.
Contents
1. SAFETYPRECAUTIONS............................................................................................1
2. PRODUCTSPECIFICATION....................................................................................... 4
2.1. Installationtools.................................................................................................4
2.2. Accessories........................................................................................................4
2.3. Piperequirements..............................................................................................4
2.4. Electricalrequirements.......................................................................................5
2.5. Additionalchargeamount..................................................................................5
2.6. Operatingrange.................................................................................................5
3. INSTALLATIONWORK............................................................................................... 5
3.1. Installationdimensions.......................................................................................6
3.2. Transportingtheunit..........................................................................................6
3.3. Mountingtheunit................................................................................................7
3.4. Draininstallation.................................................................................................7
3.5. Pipeinstallation..................................................................................................7
3.6. Sealingtest........................................................................................................8
3.7. Vacuumprocessanddryingprocess.................................................................8
3.8. Additionalcharging.............................................................................................9
3.9. Electricalwiring..................................................................................................9
3.10.Demandcontrol................................................................................................10
3.11.Protectionfortheintrusionofsmallanimals....................................................11
4. TESTRUN.................................................................................................................12
5. FINISHING.................................................................................................................12
5.1. Installinginsulation...........................................................................................12
6. PUMPDOWN............................................................................................................12
AIRCONDITIONER
OutdoorUnit
INSTALLATION MANUAL
PARTNo.9374995639-02
Forauthorizedservicepersonnelonly.
R32
R32.
9374995639-02_IM.indd 1 7/8/2019 08:56:56
En-2
2-2.Work
• Priortobeginningworkonsystemscontainingammablerefrigerants,safety
checksarenecessarytoensurethattheriskofignitionisminimised.Forrepairto
therefrigeratingsystem,theprecautionsin2-2to2-8shallbecompliedwithpriorto
conductingworkonthesystem.
• Workshallbeundertakenunderacontrolledproceduresoastominimizetheriskof
aammablegasorvapourbeingpresentwhiletheworkisbeingperformed.
• Allmaintenancestaffandothersworkinginthelocalareashallbeinstructedonthe
natureofworkbeingcarriedout.
• Workinconnedspacesshallbeavoided.
• Theareaaroundtheworkspaceshallbesectionedoff.
• Ensurethattheconditionswithintheareahavebeenmadesafebycontrolofam-
mablematerial.
2-3.Checkingforpresenceofrefrigerant
• Theareashallbecheckedwithanappropriaterefrigerantdetectorpriortoanddur-
ingwork,toensurethetechnicianisawareofpotentiallyammableatmospheres.
• Ensurethattheleakdetectionequipmentbeingusedissuitableforusewitham-
mablerefrigerants,i.e.nonsparking,adequatelysealedorintrinsicallysafe.
2-4.Presenceofreextinguisher
• Ifanyhotworkistobeconductedontherefrigerationequipmentoranyassociated
parts,appropriatereextinguishingequipmentshallbeavailableathand.
• HaveadrypowderorCO
2
reextinguisheradjacenttothechargingarea.
2-5.Noignitionsources
• Nopersoncarryingoutworkinrelationtoarefrigerationsystemwhichinvolves
exposinganypipeworkthatcontainsorhascontainedammablerefrigerantshall
useanysourcesofignitioninsuchamannerthatitmayleadtotheriskofreor
explosion.
• Allpossibleignitionsources,includingcigarettesmoking,shouldbekeptsufciently
farawayfromthesiteofinstallation,repairing,removinganddisposal,duringwhich
ammablerefrigerantcanpossiblybereleasedtothesurroundingspace.
• Priortoworktakingplace,theareaaroundtheequipmentistobesurveyedtomake
surethattherearenoammablehazardsorignitionrisks.“NoSmoking”signsshall
bedisplayed.
2-6.Ventilatedarea
• Ensurethattheareaisintheopenorthatitisadequatelyventilatedbeforebreaking
intothesystemorconductinganyhotwork.
• Adegreeofventilationshallcontinueduringtheperiodthattheworkiscarriedout.
• Theventilationshouldsafelydisperseanyreleasedrefrigerantandpreferablyexpel
itexternallyintotheatmosphere.
2-7.Checkstotherefrigerationequipment
• Whereelectricalcomponentsarebeingchanged,theyshallbetforthepurpose
andtothecorrectspecication.
• Atalltimesthemanufacturer’smaintenanceandserviceguidelinesshallbefollowed.
• Ifindoubtconsultthemanufacturer’stechnicaldepartmentforassistance.
• Thefollowingchecksshallbeappliedtoinstallationsusingammablerefrigerants.
-Thechargesizeisinaccordancewiththeroomsizewithinwhichtherefrigerant
containingpartsareinstalled.
-Theventilationmachineryandoutletsareoperatingadequatelyandarenot
obstructed.
-Ifanindirectrefrigeratingcircuitisbeingused,thesecondarycircuitshallbe
checkedforthepresenceofrefrigerant.
-Markingtotheequipmentcontinuestobevisibleandlegible.Markingsandsigns
thatareillegibleshallbecorrected.
-Refrigerationpipeorcomponentsareinstalledinapositionwheretheyare
unlikelytobeexposedtoanysubstancewhichmaycorroderefrigerantcontain-
ingcomponents,unlessthecomponentsareconstructedofmaterialswhichare
inherentlyresistanttobeingcorrodedoraresuitablyprotectedagainstbeingso
corroded.
2-8.Checkstoelectricaldevices
• Repairandmaintenancetoelectricalcomponentsshallincludeinitialsafetychecks
andcomponentinspectionprocedures.
• Ifafaultexiststhatcouldcompromisesafety,thennoelectricalsupplyshallbecon-
nectedtothecircuituntilitissatisfactorilydealtwith.
• Ifthefaultcannotbecorrectedimmediatelybutitisnecessarytocontinueopera-
tion,anadequatetemporarysolutionshallbeused.
• Thisshallbereportedtotheowneroftheequipmentsoallpartiesareadvised.
• Initialsafetychecksshallinclude.
-Thatcapacitorsaredischarged:thisshallbedoneinasafemannertoavoidpos-
sibilityofsparking.
-Thattherenoliveelectricalcomponentsandwiringareexposedwhilecharging,
recoveringorpurgingthesystem.
-Thatthereiscontinuityofearthbonding.
CAUTION
Fortheairconditionertoworkappropriately,installitaswritteninthismanual.
Thisunitmustbeinstalledbyqualiedpersonnelwithacapacitycerticationofhandling
refrigerantuids.Refertoregulationandlawsinuseoninstallationplace.
Installtheunitbyfollowinglocalcodesandregulationsinforceintheplaceof
installation,andtheinstructionsprovidedbymanufacturer.
Thisunitispartofasetconstitutinganairconditioner.Theunitmustnotbeinstalled
aloneorbeinstalledwithdevicenotauthorizedbythemanufacturer.
Wheninstallingpipesshorterthan5m,soundoftheoutdoorunitmaybetransferredto
theindoorunit,whichmaycauselargeoperatingorabnormalsound.
Alwaysuseaseparatepowersupplylineprotectedbyacircuitbreakeroperatingonall
wireswithadistancebetweencontactof3mmforthisunit.
Toprotectthepersons,earth(ground)theunitcorrectly,andusethepowercable
combinedwithanEarthLeakageCircuitBreaker(ELCB).
Theunitsarenotexplosionproofandthereforeshouldnotbeinstalledinexplosive
atmosphere.
Thisunitcontainsnouser-serviceableparts.Alwaysconsultauthorizedservice
personneltorepairs.
Whenmovingorrelocatingtheairconditioner,consultexperiencedservicetechnicians
fordisconnectionandreinstallationoftheunit.
Childrenshouldbemonitoredtoensuretheydonotplaywiththedevice.
Donottouchthealuminumnsofheatexchangerbuilt-intheindoororoutdoorunitto
avoidpersonalinjurywhenyouinstallormaintaintheunit.
Donotplaceanyotherelectricalproductsorhouseholdbelongingsunderindoorunitor
outdoorunit.Drippingcondensationfromtheunitmightgetthemwet,andmaycause
damageormalfunctionofyourproperty.
Precautions for using R32 refrigerant
Thebasicinstallationworkproceduresarethesameasconventionalrefrigerant(R410A,
R22)models.
However,paycarefulattentiontothefollowingpoints:
WARNING
Sincetheworkingpressureis1.6timeshigherthanthatofrefrigerantR22models,
someofthepipingandinstallationandservicetoolsarespecial.(See“2.1.Installation
tools”.)
Especially,whenreplacingarefrigerantR22modelwithanewrefrigerantR32model,
alwaysreplacetheconventionalpipingandarenutswiththeR32andR410Apiping
andarenutsontheoutdoorunitside.
ForR32andR410A,thesamearenutontheoutdoorunitsideandpipecanbeused.
ModelsthatuserefrigerantR32andR410Ahaveadifferentchargingportthreaddiam-
etertopreventerroneouschargingwithrefrigerantR22andforsafety.Therefore,check
beforehand.[ThechargingportthreaddiameterforR32andR410Ais1/2inch.]
BemorecarefulthanR22sothatforeignmatter(oil,water,etc.)doesnotenterthepiping.
Also,whenstoringthepiping,securelysealtheopeningbypinching,taping,etc.(Han-
dlingofR32issimilartoR410A.)
CAUTION
1.Installation(Space)
• Thattheinstallationofpipe-workshallbekepttoaminimum.
• Thatpipe-workshallbeprotectedfromphysicaldamage.
• Thatcompliancewithnationalgasregulationsshallbeobserved.
• Thatmechanicalconnectionsshallbeaccessibleformaintenancepurposes.
• Incasesthatrequiremechanicalventilation,ventilationopeningsshallbekeptclear
ofobstruction.
• Whendisposingoftheproductisused,bebasedonnationalregulations,properly
processed.
2.Servicing
2-1.Servicepersonnel
• Anypersonwhoisinvolvedwithworkingonorbreakingintoarefrigerantcircuit
shouldholdacurrentvalidcerticatefromanindustry-accreditedassessment
authority,whichauthorizestheircompetencetohandlerefrigerantssafelyinaccord-
ancewithanindustryrecognisedassessmentspecication.
• Servicingshallonlybeperformedasrecommendedbytheequipmentmanufacturer.
Maintenanceandrepairrequiringtheassistanceofotherskilledpersonnelshallbe
carriedoutunderthesupervisionofthepersoncompetentintheuseofammable
refrigerants.
• Servicingshallbeperformedonlyasrecommendedbythemanufacturer.
9374995639-02_IM.indd 2 7/8/2019 08:56:57
En-3
3.Repairstosealedcomponents
• Duringrepairstosealedcomponents,allelectricalsuppliesshallbedisconnected
fromtheequipmentbeingworkeduponpriortoanyremovalofsealedcovers,etc.
• Ifitisabsolutelynecessarytohaveanelectricalsupplytoequipmentduringservic-
ing,thenapermanentlyoperatingformofleakdetectionshallbelocatedatthemost
criticalpointtowarnofapotentiallyhazardoussituation.
• Particularattentionshallbepaidtothefollowingtoensurethatbyworkingonelec-
tricalcomponents,thecasingisnotalteredinsuchawaythatthelevelofprotection
isaffected.
• Thisshallincludedamagetocables,excessivenumberofconnections,terminals
notmadetooriginalspecication,damagetoseals,incorrectttingofglands,etc.
• Ensurethatapparatusismountedsecurely.
• Ensurethatsealsorsealingmaterialshavenotdegradedsuchthattheynolonger
servethepurposeofpreventingtheingressofammableatmospheres.
• Replacementpartsshallbeinaccordancewiththemanufacturer’sspecications.
NOTE:Theuseofsiliconsealantmayinhibittheeffectivenessofsometypesofleak
detectionequipment.
Intrinsicallysafecomponentsdonothavetobeisolatedpriortoworkingonthem.
4.Repairtointrinsicallysafecomponents
• Donotapplyanypermanentinductiveorcapacitanceloadstothecircuitwithout
ensuringthatthiswillnotexceedthepermissiblevoltageandcurrentpermittedfor
theequipmentinuse.
• Intrinsicallysafecomponentsaretheonlytypesthatcanbeworkedonwhilelivein
thepresenceofaammableatmosphere.
• Thetestapparatusshallbeatthecorrectrating.
• Replacecomponentsonlywithpartsspeciedbythemanufacturer.
• Otherpartsmayresultintheignitionofrefrigerantintheatmospherefromaleak.
5.Cabling
• Checkthatcablingwillnotbesubjecttowear,corrosion,excessivepressure,vibra-
tion,sharpedgesoranyotheradverseenvironmentaleffects.
• Thecheckshallalsotakeintoaccounttheeffectsofagingorcontinualvibration
fromsourcessuchascompressorsorfans.
6.Detectionofammablerefrigerants
• Undernocircumstancesshallpotentialsourcesofignitionbeusedinthesearching
forordetectionofrefrigerantleaks.
• Ahalidetorch(oranyotherdetectorusinganakedame)shallnotbeused.
7.Leakdetectionmethods
• Electronicleakdetectorsshallbeusedtodetectammablerefrigerants,butthe
sensitivitymaynotbeadequate,ormayneedre-calibration.(Detectionequipment
shallbecalibratedinarefrigerant-freearea.)
• Ensurethatthedetectorisnotapotentialsourceofignitionandissuitableforthe
refrigerantused.
• LeakdetectionequipmentshallbesetatapercentageoftheLFLoftherefrigerant
andshallbecalibratedtotherefrigerantemployedandtheappropriatepercentage
ofgas(25%maximum)isconrmed.
• Leakdetectionuidsaresuitableforusewithmostrefrigerantsbuttheuseof
detergentscontainingchlorineshallbeavoidedasthechlorinemayreactwiththe
refrigerantandcorrodethecopperpipe-work.
• Ifaleakissuspected,allnakedamesshallberemoved/extinguished.
• Ifaleakageofrefrigerantisfoundwhichrequiresbrazing,alloftherefrigerantshall
berecoveredfromthesystem,orisolated(bymeansofshutoffvalves)inapartof
thesystemremotefromtheleak.
Oxygenfreenitrogen(OFN)shallthenbepurgedthroughthesystembothbefore
andduringthebrazingprocess.
8.Removalandevacuation
• Whenbreakingintotherefrigerantcircuittomakerepairs–orforanyother
purpose–conventionalproceduresshallbeused.
However,itisimportantthatbestpracticeisfollowedsinceammabilityisaconsid-
eration.
Thefollowingprocedureshallbeadheredto:
• removerefrigerant
• purgethecircuitwithinertgas
• evacuate
• purgeagainwithinertgas
• openthecircuitbycuttingorbrazing
• Therefrigerantchargeshallberecoveredintothecorrectrecoverycylinders.
• Thesystemshallbe“ushed”withOFNtorendertheunitsafe.
• Thisprocessmayneedtoberepeatedseveraltimes.
• Compressedairoroxygenshallnotbeusedforthistask.
• FlushingshallbeachievedbybreakingthevacuuminthesystemwithOFNand
continuingtolluntiltheworkingpressureisachieved,thenventingtoatmosphere,
andnallypullingdowntoavacuum.
• Thisprocessshallberepeateduntilnorefrigerantiswithinthesystem.
• WhenthenalOFNchargeisused,thesystemshallbeventeddowntoatmos-
phericpressuretoenableworktotakeplace.
• Thisoperationisabsolutelyvitalifbrazingoperationsonthepipeworkaretotakeplace.
• Ensurethattheoutletforthevacuumpumpisnotclosetoanyignitionsourcesand
thereisventilationavailable.
9.Chargingprocedures
• Inadditiontoconventionalchargingprocedures,thefollowingrequirementsshallbe
followed.
-Ensurethatcontaminationofdifferentrefrigerantsdoesnotoccurwhenusing
chargingequipment.
-Hosesorlinesshallbeasshortaspossibletominimizetheamountofrefrigerant
containedinthem.
-Cylindersshallbekeptupright.
-Ensurethattherefrigerationsystemisearthedpriortochargingthesystemwith
refrigerant.
-Labelthesystemwhenchargingiscomplete(ifnotalready).
-Extremecareshallbetakennottooverlltherefrigerationsystem.
• PriortorechargingthesystemitshallbepressuretestedwithOFN.
• Thesystemshallbeleaktestedoncompletionofchargingbutpriortocommissioning.
• Afollowupleaktestshallbecarriedoutpriortoleavingthesite.
10.Decommissioning
• Beforecarryingoutthisprocedure,itisessentialthatthetechnicianiscompletely
familiarwiththeequipmentandallitsdetails.
• Itisrecommendedgoodpracticethatallrefrigerantsarerecoveredsafely.
• Priortothetaskbeingcarriedout,anoilandrefrigerantsampleshallbetakenin
caseanalysisisrequiredpriortore-useofreclaimedrefrigerant.
• Itisessentialthatelectricalpowerisavailablebeforethetaskiscommenced.
a)Becomefamiliarwiththeequipmentanditsoperation.
b)Isolatesystemelectrically.
c)Beforeattemptingtheprocedureensurethat:
• mechanicalhandlingequipmentisavailable,ifrequired,forhandlingrefriger-
antcylinders;
• allpersonalprotectiveequipmentisavailableandbeingusedcorrectly;
• therecoveryprocessissupervisedatalltimesbyacompetentperson;
• recoveryequipmentandcylindersconformtotheappropriatestandards.
d)Pumpdownrefrigerantsystem,ifpossible.
e)Ifavacuumisnotpossible,makeamanifoldsothatrefrigerantcanberemoved
fromvariouspartsofthesystem.
f)Makesurethatcylinderissituatedonthescalesbeforerecoverytakesplace.
g)Starttherecoverymachineandoperateinaccordancewithmanufacturer’s
instructions.
h)Donotoverllcylinders.(Nomorethan80%volumeliquidcharge).
i)Donotexceedthemaximumworkingpressureofthecylinder,eventemporarily.
j)Whenthecylindershavebeenlledcorrectlyandtheprocesscompleted,make
surethatthecylindersandtheequipmentareremovedfromsitepromptlyand
allisolationvalvesontheequipmentareclosedoff.
k)Recoveredrefrigerantshallnotbechargedintoanotherrefrigerationsystem
unlessithasbeencleanedandchecked.
11.Labelling
• Equipmentshallbelabelledstatingthatithasbeende-commissionedandemptied
ofrefrigerant.
• Thelabelshallbedatedandsigned.
• Ensurethattherearelabelsontheequipmentstatingtheequipmentcontainsam-
mablerefrigerant.
12.Recovery
• Whenremovingrefrigerantfromasystem,eitherforservicingordecommissioning,
itisrecommendedgoodpracticethatallrefrigerantsareremovedsafely.
• Whentransferringrefrigerantintocylinders,ensurethatonlyappropriaterefrigerant
recoverycylindersareemployed.
• Ensurethatthecorrectnumberofcylindersforholdingthetotalsystemchargeare
available.
• Allcylinderstobeusedaredesignatedfortherecoveredrefrigerantandlabelledfor
thatrefrigerant(i.e.specialcylindersfortherecoveryofrefrigerant).
• Cylindersshallbecompletewithpressurereliefvalveandassociatedshut-offvalves
ingoodworkingorder.
• Emptyrecoverycylindersareevacuatedand,ifpossible,cooledbeforerecovery
occurs.
• Therecoveryequipmentshallbeingoodworkingorderwithasetofinstructions
concerningtheequipmentthatisathandandshallbesuitablefortherecoveryof
ammablerefrigerants.
• Inaddition,asetofcalibratedweighingscalesshallbeavailableandingoodwork-
ingorder.
• Hosesshallbecompletewithleak-freedisconnectcouplingsandingoodcondition.
• Beforeusingtherecoverymachine,checkthatitisinsatisfactoryworkingorder,has
beenproperlymaintainedandthatanyassociatedelectricalcomponentsaresealed
topreventignitionintheeventofarefrigerantrelease.
Consultmanufacturerifindoubt.
• Therecoveredrefrigerantshallbereturnedtotherefrigerantsupplierinthecorrect
recoverycylinder,andtherelevantWasteTransferNotearranged.
• Donotmixrefrigerantsinrecoveryunitsandespeciallynotincylinders.
• Ifcompressorsorcompressoroilsaretoberemoved,ensurethattheyhavebeen
evacuatedtoanacceptableleveltomakecertainthatammablerefrigerantdoes
notremainwithinthelubricant.
• Theevacuationprocessshallbecarriedoutpriortoreturningthecompressortothe
suppliers.
• Onlyelectricheatingtothecompressorbodyshallbeemployedtoacceleratethis
process.
• Whenoilisdrainedfromasystem,itshallbecarriedoutsafely.
9374995639-02_IM.indd 3 7/8/2019 08:56:57
En-4
Explanationofsymbolsdisplayedontheindoorunitoroutdoorunit.
WARNING
Thissymbolshowsthatthisequipmentusesaammable
refrigerant.
Iftherefrigerantisleaked,togetherwithanexternaligni-
tionsource,thereisapossibilityofignition.
CAUTION
ThissymbolshowsthattheOperationManualshouldbe
readcarefully.
CAUTION
Thissymbolshowsthataservicepersonnelshouldbe
handlingthisequipmentwithreferencetotheInstallation
Manual.
CAUTION
Thissymbolshowsthatthereisinformationincludedinthe
OperationManualand/orInstallationManual.
2. PRODUCT SPECIFICATION
2.1. Installation tools
WARNING
ToinstallaunitthatusesR32refrigerant,usededicatedtoolsandpipingmaterialsthat
havebeenmanufacturedspecicallyforR32(R410A)use.BecausethepressureofR32
refrigerantisapproximately1.6timeshigherthanR22,failuretousededicatedpiping
materialorimproperinstallationcancauseruptureorinjury.Furthermore,itcancause
seriousaccidentssuchaswaterleakage,electricshock,orre.
Donotuseavacuumpumporrefrigerantrecoverytoolswithaseriesmotor,sinceit
mayignite.
Tool name Change from R22 to R32(R410A)
Gaugemanifold Pressureishighandcannotbemeasuredwithaconventional
(R22)gauge.Topreventerroneousmixingofotherrefrigerants,
thediameterofeachporthasbeenchanged.
Itisrecommendedthegaugewithseals–0.1to5.3MPa(-1to
53bar)forhighpressure.–0.1to3.8MPa(-1to38bar)forlow
pressure.
Charginghose Toincreasepressureresistance,thehosematerialandbase
sizewerechanged.(R32/R410A)
Vacuumpump Aconventionalvacuumpumpcanbeusedbyinstallinga
vacuumpumpadapter.
(Useofavacuumpumpwithaseriesmotorisprohibited.)
Gasleakagedetector SpecialgasleakagedetectorforHFCrefrigerantR410A.
Copper pipes
Itisnecessarytouseseamlesscopperpipesanditisdesirablethattheamountofresidual
oilislessthan40mg/10m.Donotusecopperpipeshavingacollapsed,deformedor
discoloredportion(especiallyontheinteriorsurface).Otherwise,theexpansionvalveor
capillarytubemaybecomeblockedwithcontaminants.
AsanairconditionerusingR32(R410A)incurspressurehigherthanwhenusing
conventionalrefrigerant,itisnecessarytochooseadequatematerials.
ThicknessesofcopperpipesusedwithR32(R410A)areasshowninthetable.Neveruse
copperpipesthinnerthanthatinthetableevenwhenitisavailableonthemarket.
Thicknesses of Annealed Copper Pipes
Pipe outside diameter [mm (in.)] Thickness [mm]
9.52(3/8) 0.80
15.88(5/8) 1.00
2.2. Accessories
WARNING
Forinstallationpurposes,besuretousethepartssuppliedbythemanufacturerorother
prescribedparts.Theuseofnon-prescribedpartscancauseseriousaccidentssuchas
theunitfalling,waterleakage,electricshock,orre.
Followinginstallationpartsaresupplied.Usethemasrequired.
Keepthismanualinasafeplace,anddonotdiscardanyotheraccessoriesuntilthe
installationworkhasbeencompleted.
Name and shape Q’ty Description
Installation
manual
1
Thismanual
Drainpipe
1
Foroutdoorunitdrainpipingwork
(Maynotbesupplied,dependingon
themodel.)
Draincap
2
PartslistfordemandcontrolPCBkit
Name and shape Q’ty Description
Cabletiewithclips
1
Forxingthesignaltransmission
cable.
Cabletie(small)
1
ForxingtheEMIcoreandthesignal
transmissioncable.
EMIcore
1
Attachedtothesignaltransmission
cable.
Insulation
2 ForattachingtheEMIcore.
2.3. Pipe requirements
Selecting the pipe material
CAUTION
Donotuseexistingpipes.
Usepipesthathavecleanexternalandinternalsideswithoutanycontaminationwhich
maycausetroubleduringuse,suchassulfur,oxide,dust,cuttingwaste,oil,orwater.
Itisnecessarytouseseamlesscopperpipes.
Material:Phosphordeoxidizedseamlesscopperpipes.
Itisdesirablethattheamountofresidualoilislessthan40mg/10m.
Donotusecopperpipesthathaveacollapsed,deformed,ordiscoloredportion
(especiallyontheinteriorsurface).Otherwise,theexpansionvalveorcapillarytubemay
becomeblockedwithcontaminants.
Improperpipeselectionwilldegradeperformance.Asanairconditionerusing
R32(R410A)incurspressurehigherthanwhenusingconventionalrefrigerant,itis
necessarytochooseadequatematerials.
NOTE:
ThicknessesofcopperpipesusedwithR32(R410A)areasshowninthetable.
Neverusecopperpipesthinnerthanthoseindicatedinthetableeveniftheyareavailable
onthemarket.
Thicknesses of Annealed Copper Pipes
Pipe outside diameter [mm (in.)]
Thickness
[mm]
9.52(3/8) 0.80
15.88(5/8) 1.00
Protection of pipes
Protectthepipestopreventtheentryofmoistureanddust.
Especially,payattentionwhenpassingthepipesthroughaholeorconnectingtheendof
apipetotheoutdoorunit.
Location Working period Protection method
Outdoor
1monthormore Pinchpipes
Lessthan1month Pinchortapepipes
Indoor - Pinchortapepipes
Refrigerant pipe size and allowable piping length
CAUTION
Keepthepipinglengthbetweentheindoorunitandoutdoorunitwithintheallowable
tolerance.
Themaximumlengthsofthisproductareshowninthetable.Iftheunitsarefurtherapart
thanthis,correctoperationcannotbeguaranteed.
Pipediameter<Liquid/Gas>[mm(in.)] 9.52(3/8)/15.88(5/8)
Max.pipinglength(L)[m] 75
*1
Max.heightdifference(H)
<Indoorunittooutdoorunit>[m]
30
View(Example)
H
L
*1:Forthestandardpipediameter.
9374995639-02_IM.indd 4 7/8/2019 08:57:01
En-5
2.4. Electrical requirements
CAUTION
Besuretoinstallabreakerwithspeciedcapacity.
Beforetheelectricalworking,conrmelectricalstandardsandregulationsineachcountry,
region,orinstallingplace.Thenselectappropriatecablesandbreakersthatcomplywiththem.
Voltage rating 1Φ240V(50Hz)
Operating range 198to264V
Cable Conductorsize[mm
2
]
*1
Type Remarks
PowerSupplyCable 2.5-4.0 Type60245IEC66
2Cable+Earth(Ground)
1Φ240V
ConnectionCable 1.5-2.5 Type60245IEC57
3Cable+Earth(Ground)
1Φ240V
Demandcontrol
signaltransmission
cable
0.5-1.5 AS/NZS5000.2
Doubleinsulated
(Max.length:30m)
*1
Selectedsample:Selectthecorrectcabletypeandsizeaccordingtothecountryor
region’sregulations.
Max.wirelength:Setalengthsothatthevoltagedropislessthan2%.Increasethewire
diameterwhenthewirelengthislong.
Breaker Specication
*2
Circuitbreaker(overcurrent) Current:20(A)
Earthleakagebreaker Leakagecurrent:30mA0.1secorless
*3
*2
Selecttheappropriatebreakerofthedescribedspecicationaccordingtothenationalor
regionalstandards.
*3
Selectthebreakerthatenoughloadcurrentcanpassthroughit.
• Beforestartingworkcheckthatpowerisnotbeingsuppliedtoallpolesoftheindoor
unitandoutdoorunit.
• Installallelectricalworksinaccordancetostandard.
• Installthedisconnectdevicewithacontactgapofatleast3mminallpolesnearbythe
units.(Bothindoorunitandoutdoorunit)
• Wiringsizemustcomplywiththeapplicablelocalandnationalcode.
2.5. Additional charge amount
For Pre-charge lengths
Piping length (L) *Pre-Charge [m]
20
If additional refrigerant is required
• WhenthepipingislongerthanPre-chargelength,additionalchargingisnecessary.
• Fortheadditionalamount,seethetablebelow.
Additional charging amount
Refrigerant pipe size
[mm (in.)]
Piping length (L)*
~20m
30m 40m 50m 60m 70m 75m g/m
Liquid 9.52(3/8)
None 400g 800g
1,200g 1,600g 2,000g 2,200g
40g/m
Gas 15.88(5/8)
*Referto“Refrigerantpipesizeandallowablepipinglength”.
Maximum amount of refrigerant charge
3850g(1650g+2200g)
2.6. Operating range
Coolingmode
Drymode
Heatingmode
[Reversecyclemodelonly]
Outdoor
temperature
-10to46˚C
-15 to 24 ˚C
• Ifthisunitisoperatedoutsidetheoperatingtemperature,theprotectioncircuitsmaybe
activatedtostoptheunit.
3. INSTALLATION WORK
Makesuretoobtainthecustomer’sapprovalforselectingandinstallingtheoutdoorunit.
WARNING
Securelyinstalltheoutdoorunitatalocationthatcanwithstandtheweightoftheunit.
Otherwise,theoutdoorunitmayfallandcauseinjury.
Besuretoinstalltheoutdoorunitasprescribed,sothatitcanwithstandearthquakes
andtyphoonsorotherstrongwinds.Improperinstallationcancausetheunittotoppleor
fall,orotheraccidents.
Donotinstalltheoutdoorunitneartheedgeofabalcony.Otherwise,childrenmayclimb
ontotheoutdoorunitandfalloffofthebalcony.
CAUTION
Donotinstalltheoutdoorunitinthefollowingareas:
• Areawithhighsaltcontent,suchasattheseaside.Itwilldeterioratemetalparts,
causingthepartstofailortheunittoleakwater.
• Arealledwithmineraloilorcontainingalargeamountofsplashedoilorsteam,suchas
akitchen.Itwilldeteriorateplasticparts,causingthepartstofailortheunittoleakwater.
• Areathatgeneratessubstancesthatadverselyaffecttheequipment,suchassulfuric
gas,chlorinegas,acid,oralkali.Itwillcausethecopperpipesandbrazedjointsto
corrode,whichcancauserefrigerantleakage.
• Areacontainingequipmentthatgenerateselectromagneticinterference.Itwillcause
thecontrolsystemtomalfunction,preventingtheunitfromoperatingnormally.
• Areathatcancausecombustiblegastoleak,containssuspendedcarbonbersor
ammabledust,orvolatileinammablessuchaspaintthinnerorgasoline.Ifgas
leaksandsettlesaroundtheunit,itcancauseare.
• Areawheresmallanimalsmaylive.Itmaycausefailure,smokeorreifsmall
animalsenterandtouchinternalelectricalparts.
• Areawhereanimalsmayurinateontheunitorammoniamaybegenerated.
• Areathathasheatsources,vapors,ortheriskofleakageoraccumulationof
ammablegas.
Donottilttheoutdoorunitmorethan3degrees.
Installtheoutdoorunitinawell-ventilatedlocationawayfromrainordirectsunlight.
Iftheoutdoorunitmustbeinstalledinanareawithineasyreachofthegeneralpublic,
installasnecessaryaprotectivefenceortheliketopreventtheiraccess.
Installtheoutdoorunitinalocationthatwouldnotinconvenienceyourneighbors,as
theycouldbeaffectedbytheairowcomingoutfromtheoutlet,noise,orvibration.Ifit
mustbeinstalledinproximitytoyourneighbors,besuretoobtaintheirapproval.
Iftheoutdoorunitisinstalledinacoldregionthatisaffectedbysnowaccumulation,
snowfall,orfreezing,takeappropriatemeasurestoprotectitfromthoseelements.
Toensureastableoperation,installinletandoutletducts.
Installtheoutdoorunitinalocationthatisawayfromexhaustortheventportsthat
dischargevapor,soot,dust,ordebris.
Installtheindoorunit,outdoorunit,powersupplycable,connectioncable,andremote
controlcableatleast1mawayfromatelevisionorradioreceivers.Thepurposeofthis
istopreventTVreceptioninterferenceorradionoise.(Eveniftheyareinstalledmore
than1mapart,youcouldstillreceivenoiseundersomesignalconditions.)
Ifchildrenunder10yearsoldmayapproachtheunit,takepreventivemeasuressothat
theycannotreachtheunit.
Keepthelengthofthepipingoftheindoorandoutdoorunitswithintheallowablerange.
Formaintenancepurposes,donotburythepiping.
9374995639-02_IM.indd 5 7/8/2019 08:57:01
En-6
3.1. Installation dimensions
3.1.1. Outdoor unit installation
When the upper space is open: (Unit:mm)
(1)Obstaclesatrearonly
100ormore
(2)Obstaclesatrearandsides
250ormore
300ormore
100ormore
(3)Obstaclesatfront
600ormore
(4)Obstaclesatfrontandrear
600ormore
100ormore
When an obstruction in the upper space: (Unit:mm)
(1)Obstaclesatrearandabove
300ormore
Max.500
600or
more
(2)Obstaclesattherear,sides,andabove
1,000or
more
100ormore
250ormore
500ormore
Max.500
3.1.2. Multiple outdoor unit installation
• Provideatleast250mmofspacebetweentheoutdoorunitsifmultipleunitsare
installed.
• Whenroutingthepipingfromthesideofanoutdoorunit,providespaceforthepiping.
When the upper space is open: (Unit:mm)
(1)Obstaclesattherearonly
300or
more
250ormore
(2)Obstaclesatthefrontonly
1,500ormore
250ormore
(3)Obstaclesatthefrontandrear
500ormore
1,500ormore
250ormore
When an obstruction in the upper space: (Unit:mm)
(1)Obstaclesattherearandabove
• Upto3unitscanbeinstalledsidebyside.
• When4unitsormorearearrangedinaline,providethespaceasshownbelow.
1,500ormore
500ormore
250ormore
250ormore
Max.300
1,500ormore
3.1.3. Outdoor units installation multi-row (Unit:mm)
(1)Singleparallelunitarrangement
150ormore
600ormore
1,000ormore
2,000ormore
(2)Multipleparallelunitarrangement
500ormore
600ormore
1,500ormore
250ormore
3,000ormore
250ormore
1,500ormore
500ormore
250ormore
CAUTION
Donotinstalltheoutdoorunitintwo-stagewherethedrainwatercouldfreeze.
Otherwisethedrainagefromtheupperunitmayformiceandcauseamalfunctionofthe
lowerunit.
NOTES:
• Ifthespaceislargerthanstatedabove,theconditionwillbethesameaswhenthereis
noobstacle.
• Heightabovetheoorlevelshouldbe2in(50mm)ormore.
• Wheninstallingtheoutdoorunit,besuretoopenthefrontandleftsidetoobtainbetter
operationefciency.
3.2. Transporting the unit
WARNING
Donottouchthens.
Otherwise,personalinjurycouldresult.
CAUTION
Whencarryingtheunit,holdthehandlesontherightandleftsidesandbecareful.
Iftheoutdoorunitiscarriedfromthebottom,handsorngersmaybepinched.
9374995639-02_IM.indd 6 7/8/2019 08:57:06
En-7
• Besuretoholdthehandlesonthesidesoftheunit.Otherwise,thesuctiongrilleson
thesidesoftheunitmaybedeformed.
Handle
3.3. Mounting the unit
(Unit:mm)
132
AIR
650 119
50 50
16
363
4-Φ12Hole
• Install4anchorboltsatthelocationsindicatedwitharrowsintheabovegure.
• Toreducevibration,donotinstalltheunitdirectlyontheground.Installitonasecure
base(suchasconcreteblocks).
• Thefoundationshallsupportthelegsoftheunitandhaveawidthof50mmormore.
• Dependingontheinstallationconditions,theoutdoorunitmayspreaditsvibration
duringoperation,whichmaycausenoiseandvibration.Therefore,attachdamping
materials(suchasdampingpads)totheoutdoorunitduringinstallation.
• Installthefoundation,makingsurethatthereisenoughspaceforinstallingthe
connectionpipes.
• Securetheunittoasolidblockusingfoundationbolts.(Use4setsofcommercially
availableM10bolts,nuts,andwashers.)
• Theboltsshouldprotrude20mm.
(Refertothegurebelow.)
• Ifoverturningpreventionisrequired,purchasethenecessarycommerciallyavailable
items.
Bolt
20mm
Nut
Base
Fixsecurelywithboltsonasolidblock.(Use4setsofcommerciallyavailableM10bolt,
nutandwasher.)
•Donotinstalldirectlyontheground,thismayresultinequipmentfailure.
•Thedrainwaterisdischargedfromthebottomoftheequipment.Constructadrainditch
aroundthebaseanddischargethedrainwaterproperly.
•Provideamplespaceforicebuildupfromcondensatebetweenthebottomoftheunitand
theflatsurfaceonwhichitismounted.Otherwise,thereisriskthatthedrainagewater
willfreezebetweenthedeviceandthesurface,disablingdrainage.
50mmormore
CAUTION
Iftheunitisinstalledinaregionthatisexposed
tohighwinds,freezingconditions,freezingrain,
snowfallorheavysnowaccumulation,take
appropriatemeasurestoprotectitfromthose
elements.
Toensurestableoperation,theoutdoorunitmust
beinstalledonaraisedstandorrack,atorabove
theanticipatedsnowdepthfortheregion.
Theinstallationofsnowhoodsanddriftprevention
fencingisrecommendedwhenblowinganddrifting
snowiscommontotheregion.
3.4. Drain installation
CAUTION
PerformdrainworkinaccordancewiththisManual,andensurethatthedrainwateris
properlydrained.Ifthedrainworkisnotcarriedoutcorrectly,watermaydripdownfrom
theunit,wettingthefurniture.
Whentheoutdoortemperatureis0°Corless,donotusetheaccessorydrainpipe
anddraincap.Ifthedrainpipeanddraincapareused,thedrainwaterinthepipemay
freezeinextremelycoldweather.(Reversecyclemodelonly)
• Ifyouareinstallingthedrainpipe,pleaseprovide
aworkingspaceunderthebaseoftheoutdoorunit.
• Asthedrainwaterowsoutoftheoutdoorunit
duringheatingoperation,installthedrainpipeand
connectittoacommercial16mmhose.(Reverse
cyclemodelonly)
• Wheninstallingthedrainpipe,plugalltheholes
otherthanthedrainpipemountingholeinthe
bottomoftheoutdoorunitwithputtysothereisno
waterleakage.(Reversecyclemodelonly)
(Unit:mm)
Draincapmountinghole
AIR
Drainpipemountinghole
302
265
188
51
439
623
3.5. Pipe installation
CAUTION
Donotusemineraloilonaaredpart.Preventmineraloilfromgettingintothesystem
asthiswouldreducethelifetimeoftheunits.
Whileweldingthepipes,besuretoblowdrynitrogengasthroughthem.
Flaring
(1) Cuttheconnectionpipetothenecessarylengthwithapipecutter.
(2) Holdthe pipe downward so thatcuttings will not enter the pipe and remove the
burrs.
(3) Insertthearenutontothepipeandarethepipewithaaringtool.
Insertthe flare nut (always use the flare nutattached to the indoor and outdoor units
respectively)ontothepipeandperformtheareprocessingwithaaretool.
UsethespecialR32(R410A)aretool,ortheconventional(forR22)aretool.
Whenusingtheconventionalaretool,always use an allowance adjustment gaugeand
securetheAdimensionshowninthefollowingtable.
Checkif[L]isareduniformlyand
isnotcrackedorscratched.
Die
A
Pipe
Pipeoutside
diameter
A(mm)
Flaringtoolfor
R32orR410A,clutchtype
Conventional(R22)Flaringtool
Clutchtype Wingnuttype
ø9.52mm(3/8") 0to0.5 1.0to1.5 1.5to2.0
ø15.88mm(5/8") 0to0.5 1.0to1.5 1.5to2.0
Baseoftheoutdoorunit
Drainpipe
Drainpipemountinghole
9374995639-02_IM.indd 7 7/8/2019 08:57:11
En-8
CAUTION
Donotblockthewallsandtheceilinguntilthesealingtestandthechargingofthe
refrigerantgashavebeencompleted.
Formaintenancepurposes,donotburythepipingoftheoutdoorunit.
• Afterconnectingthepipes,performasealingtest.
• Makesurethatthe3-wayvalvesareclosedbeforeperformingasealingtest.
• Pressurizenitrogengasto4.15MPatoperformthesealingtest.
• Addnitrogengastoboththeliquidpipesandthegaspipes.
• Checkallareconnectionsandwelds.Then,checkthatthepressurehasnot
decreased.
• Comparethepressuresafterpressurizingandlettingitstandfor24hours,andcheck
thatthepressurehasnotdecreased.
*Whentheoutdoorairtemperaturechanges5°C,thetestpressurechanges
0.05MPa.Ifthepressurehasdropped,thepipejointsmaybeleaking.
• Ifaleakisfound,immediatelyrepairitandperformthesealingtestagain.
• Aftercompletingthesealingtest,releasethenitrogengasfrombothvalves.
• Releasethenitrogengasslowly.
3.7. Vacuum process and drying process
CAUTION
Performarefrigerantleakagetest(airtightnesstest)tocheckforleaksusingnitrogen
gaswhileallvalvesintheoutdoorunitareclosed.(Usethetestpressureindicatedon
thenameplate.)
Besuretoevacuatetherefrigerantsystemusingavacuumpump.
Therefrigerantpressuremaysometimesnotrisewhenaclosedvalveisopenedafter
thesystemisevacuatedusingavacuumpump.Thisiscausedbytheclosureofthe
refrigerantsystemoftheoutdoorunitbytheelectronicexpansionvalve.Thiswillnot
affecttheoperationoftheunit.
Ifthesystemisnotevacuatedsufciently,itsperformancewilldrop.
Useacleangaugemanifoldandcharginghosethatweredesignedspecicallyforuse
withR32(R410A).Usingthesamevacuumequipmentfordifferentrefrigerantsmay
damagethevacuumpumportheunit.
Donotpurgetheairwithrefrigerants,butuseavacuumpumptoevacuatethesystem.
Always use a vacuum pump to purge the air.
Refrigerant for purging the air is not charged in the outdoor unit at the factory.
(1) Removethecap,andconnectthegaugemanifold andthevacuumpumptothe
chargingvalvebytheservicehoses.
(2) Vacuumtheindoorunitandtheconnectingpipesuntilthepressuregaugeindicates
-0.1MPa(-76cmHg).[Forvacuumgauge:65Pa(500microns)]
(3) When -0.1 MPa (-76 cmHg) [For vacuum gauge: 65 Pa (500 microns)] is reached,
operatethevacuumpumpforatleast60minutes.
(4) Disconnecttheservicehosesandtthecaptothechargingvalvetothespeciedtorque.
(5) Remove theblank caps,andfully openthespindles ofthe3-way valveswitha
hexagonwrench[Torque:6~7N·m(60to70kgf·cm)].
(6) Tightentheblankcapsofthe2-wayvalveand3-wayvalvetothespeciedtorque.
Tightening torque
Blank cap
9.52mm(3/8in.) 20to25N·m(200to250kgf·cm)
15.88mm(5/8in.) 30to35N·m(300to350kgf·cm)
Charging port cap 12.5to16N·m(125to160kgf·cm)
Outdoorunit
Connectingpipe
Blankcap
Hexagonwrench
3-wayvalve(Gas)
Chargingport
Cap
Servicehose
withvalvecore
Usea4mm
hexagonwrench.
Lo
Hi
Gaugemanifold
Vacuumpump
Servicehose
Bending pipes
(1) Whenbendingthepipe,becarefulnottocrushit.
(2) Topreventbreakingofthepipe,avoidsharpbends.
Bendthepipewitharadiusofcurvatureof70mmorover.
(3) Ifthecopperpipeisbendthepipeorpulledtooften,itwillbecomestiff.Do not
bendthepipesmorethanthreetimesatoneplace.
Connection pipes
Outdoor unit
(1) Detachthecapsandplugsfromthepipes.
CAUTION
Besuretoapplythepipeagainsttheportontheindoorunitandtheoutdoorunitcor-
rectly.Ifthecenteringisimproper,thearenutcannotbetightenedsmoothly.Iftheare
nutisforcedtoturn,thethreadswillbedamaged.
Donotremovethearenutfromtheindoorunitpipeuntilimmediatelybeforeconnect-
ingtheconnectionpipe.
(2) Centeringthepipeagainstportontheoutdoorunit,turnthearenutwithyourhand.
Topreventgasleakage,
coatthearesurfacewith
alkylbenzeneoil(HAB).
Donotusemineraloil.
(3) Tightenthearenutoftheconnectionpipeattheoutdoorunitvalveconnector.
3-wayvalve
(Liquid)
3-wayvalve
(Gas)
Connectionpipe
(Gas)
Connection
pipe(Liquid)
Flarenut
Flarenut
(4) Whenthearenutistightenedproperlybyyourhand,useatorquewrenchtonally
tightenit.
90°
Holding
wrench
Torque wrench
Flare nut
Flare nut
Connection pipe
(liquid)
Connection pipe
CAUTION
Holdthetorquewrenchatitsgrip,keepingitintherightanglewiththepipe,inorderto
tightenthearenutcorrectly.
Flare nut Tightening torque
9.52mm(3/8in.)dia. 32to42N·m(320to420kgf·cm)
15.88mm(5/8in.)dia. 63to75N·m(630to750kgf·cm)
CAUTION
Fastenaarenutwithatorquewrenchasinstructedinthismanual.Iffastenedtoo
tight,thearenutmaybebrokenafteralongperiodoftimeandcausealeakageof
refrigerant.
Duringinstallation,makesurethattherefrigerantpipeisattachedrmlybeforeyourun
thecompressor.Donotoperatethecompressorundertheconditionofrefrigerantpiping
notattachedproperlywith3-wayvalvesopen.Thismaycauseabnormalpressureinthe
refrigerationcyclethatleadstobreakageandeveninjury.
3.6. Sealing test
WARNING
Beforeoperatingthecompressor,installthepipesandsecurelyconnectthem.
Otherwise,ifthepipesarenotinstalledandifthevalvesareopenwhenthecompressor
operates,aircouldentertherefrigerationcycle.Ifthishappens,thepressureinthe
refrigerationcyclewillbecomeabnormallyhighandcausedamageorinjury.
Aftertheinstallation,makesurethereisnorefrigerantleakage.Iftherefrigerantleaks
intotheroomandbecomesexposedtoasourceofresuchasafanheater,stove,or
burner,itproducesatoxicgas.
Donotsubjectthepipestostrongshocksduringthesealingtest.Itcanrupturethe
pipesandcauseseriousinjury.
9374995639-02_IM.indd 8 7/8/2019 08:57:12
En-9
CAUTION
Installinsulationaroundboththegasandliquidpipes.Failuretodosomaycausewater
leaks.
Useinsulationwithheatresistanceabove120°C.(Reversecyclemodelonly)
Inaddition,ifthehumiditylevelattheinstallationlocationoftherefrigerantpipingis
expectedtoexceed70%,installinsulationaroundtherefrigerantpiping.Iftheexpected
humiditylevelis70-80%,useinsulationthatis15mmorthicker,andiftheexpected
humiditylevelexceeds80%,useinsulationthatis20mmorthicker.
Ifinsulationisusedthatisnotasthickasspecied,condensationmayformonthe
surfaceoftheinsulation.
Inaddition,useinsulationwithheatconductivityof0.045W/(m·K)orless(at20°C).
3.8. Additional charging
WARNING
Whenmovingandinstallingtheairconditioner,donotmixgasotherthanthespecied
refrigerantR32insidetherefrigerantcycle.
Ifairorothergasenterstherefrigerantcycle,thepressureinsidethecyclewillrisetoan
abnormallyhighvalueandcausebreakage,injury,etc.
CAUTION
Aftervacuumingthesystem,addrefrigerant.
Donotreuserecoveredrefrigerant.
WhenchargingtherefrigerantR32,alwaysuseanelectronicscalesforrefrigerant
charging(tomeasuretherefrigerantbyweight).Addingmorerefrigerantthanthe
speciedamountwillcauseamalfunction.
Whenchargingtherefrigerant,takeintoaccounttheslightchangeinthecomposition
ofthegasandliquidphases,andalwayschargefromtheliquidphasesidewhose
compositionisstable.
Checkifthesteelcylinderhasasiphoninstalledornotbeforelling.(Thereisan
indication“withsiphonforllingliquid”onthesteelcylinder.)
Filling method for cylinder with siphon
R32
Gas
Liquid
Setthecylinderverticalandllwiththeliquid.
(Liquidcanbelledwithoutturningbottomupwiththe
siphoninside.)
Filling method for other cylinders
R32
Gas
Liquid
Turnbottomupandllwithliquid.
(Becarefultoavoidturningoverthecylinder.)
BesuretousethespecialtoolsforR32(R410A)forpressureresistanceandtoavoid
mixingofimpuresubstances.
Iftheunitsarefurtherapartthanthemaximumpipelength,correctoperationcannotbe
guaranteed.
Makesuretobackclosingvalveafterrefrigerantcharging.Otherwise,thecompressor
mayfail.
Minimizerefrigerantreleasetotheair.ExcessivereleaseisprohibitedundertheFreon
CollectionandDestructionLaw.
3.9. Electrical wiring
WARNING
Wiringconnectionsmustbeperformedbyaqualiedpersoninaccordancewiththe
specications.Thevoltageratingforthisproductis220-240Vat50Hz.Itshouldbe
operatedwithintherangeof198to264V.
Beforeconnectingthewires,makesurethepowersupplyisOFF.
Useadedicatedpowersupplycircuit.Insufcientpowercapacityintheelectricalcircuit
orimproperwiringmaycauseelectricshockorre.
Installabreakeratthepowersupplyforeachoutdoorunit.Improperbreakerselection
cancauseelectricshockorre.
Installaleakagecircuitbreakerinaccordancewiththerelatedlawsandregulations.An
improperlyinstalledelectricalboxcovercancauseseriousaccidentssuchaselectric
shockorrethroughexposuretodustorwater.
Acircuitbreakerisinstalledinthepermanentwiring.Alwaysuseacircuitthatcantrip
allthepolesofthewiringandhasanisolationdistanceofatleast3mmbetweenthe
contactsofeachpole.
Usedesignatedcablesandpowercables.Improperusemaycauseelectricshockorre
bypoorconnection,insufcientinsulation,orovercurrent.
Donotmodifypowercable,useextensioncableorbranchwiring.Improperusemay
causeelectricshockorrebypoorconnection,insufcientinsulationorovercurrent.
Connecttheconnectorcablesecurelytotheterminal.Checknomechanicalforcebears
onthecablesconnectedtotheterminals.Faultyinstallationcancauseare.
Useringterminalsandtightentheterminalscrewstothespeciedtorques,otherwise,
abnormaloverheatingmaybeproducedandpossiblycauseseriousdamageinsidethe
unit.
Makesuretosecuretheinsulationportionoftheconnectorcablewiththecableclamp.
Damagedinsulationcancauseashortcircuit.
Fixcablessothatcablesdonotmakecontactwiththepipes(especiallyonhigh
pressureside).Donotmakepowersupplycableandtransmissioncablecomein
contactwithvalves(Gas).
Neverinstallapowerfactorimprovementcondenser.Insteadofimprovingthepower
factor,thecondensermayoverheat.
Besuretoperformtheearthing(grounding)work.
Donotconnectearthing(grounding)wirestoagaspipe,waterpipe,lightningrodor
earthing(grounding)wireforatelephone.
• Connectiontoagaspipemaycauseareorexplosionifgasleaks.
• Connectiontoawaterpipeisnotaneffectiveearthing(grounding)methodifPVC
pipeisused.
• Connectiontotheearthing(grounding)wireofatelephoneortoalightningrodmay
causeadangerouslyabnormalriseintheelectricalpotentialiflightningstrikes.
Improperearthing(grounding)workcancauseelectricshocks.
Securelyinstalltheelectricalboxcoverontheunit.Animproperlyinstalledservicepanel
cancauseseriousaccidentssuchaselectricshockorrethroughexposuretodustor
water.
CAUTION
Theprimarypowersupplycapacityisfortheairconditioneritself,anddoesnotinclude
theconcurrentuseofotherdevices.
Donotstartoperationuntiltherefrigerantischargedcompletely.Thecompressorwill
failifitisoperatedbeforetherefrigerantpipingchargingiscomplete.
Transmissioncablebetweenindoorunitandoutdoorunitis240V.
Besurenottoremovethermistorsensoretc.frompowerwiringandconnectionwiring.
Compressormayfailifoperatedwhileremoved.
Startwiringworkafterclosingbranchswitchandovercurrentbreaker.
Useanearthleakagebreakerthatiscapableofhandlinghighfrequencies.Becausethe
outdoorunitisinvertercontrolled,ahigh-frequencyearthleakagebreakerisnecessary
topreventamalfunctionofthebreakeritself.
Whenusinganearthleakagebreakerthathasbeendesignedsolelyforearth(ground)
faultprotection,besuretoinstallafuse-equippedswitchorcircuitbreaker.
DonotconnecttheACpowersupplytothetransmissionlineterminalboard.Improper
wiringcandamagetheentiresystem.
Donotusecrossoverpowersupplywiringfortheoutdoorunit.
Ifthetemperaturesurroundingthebreakeristoohigh,theamperageatwhichthe
breakercutsoutmaydecrease.
Becarefulnottogenerateasparkasfollowsforusingaammablerefrigerant.
• Donotremovethefusewhilepowerison.
• Donotdisconnectplugfromthewalloutletandthewiringwhilethepowerison.
• Itisrecommendedtopositiontheoutletconnectioninahighposition.Placethe
cordssothattheydonotgettangled.
Conrmtheindoorunitmodelnamebeforeconnecting.
IftheindoorunitisnotR32compatible,errorsignalwillbedisplayed,andtheunitwillbe
inoperable.
How to connect wiring to the terminal
Cautionwhenwiringcable
Whenstrippingoffthecoatingofaleadwire,alwaysuseaspecialtoolsuchasawire
stripper.Ifthereisnospecialtoolavailable,carefullystripthecoatingwithaknifeetc.
(1) Useringterminalswithinsulatingsleevesasshowninthegurebelowtoconnect
totheterminalblock.
(2) Securelyclamptheringterminalstothewiresusinganappropriatetoolsothatthe
wiresdonotcomeloose.
Sleeve
Strip:10mm
Ringterminal
(3) Usethespeciedwires,connectthemsecurely,andfastenthemsothatthereisno
stressplacedontheterminals.
(4) Useanappropriatescrewdrivertotightentheterminalscrews.Donotusea
screwdriverthatistoosmall,otherwise,thescrewheadsmaybedamagedand
preventthescrewsfrombeingproperlytightened.
(5) Donottightentheterminalscrewstoomuch,otherwise,thescrewsmaybreak.
Wire
Screwwithspecialwasher
Ringterminal
Terminalblocks

Screwwith
specialwasher
Wire
Ringterminal
(6) Seethetablebelowfortheterminalscrewtighteningtorques.
Tightening torque
[N·m (kgf·cm)]
M4screw 1.2to1.8(12to18)
M5screw 2.0to3.0(20to30)
9374995639-02_IM.indd 9 7/8/2019 08:57:13
En-10
Connection diagrams
EARTH
(GROUND)
N
L
3
3
2
2
1
1
POWERSUPPLY
Indoorunit
sideterminal
Outdoorunit
sideterminal
(GROUND)
EARTH
EARTH
(GROUND)
Earthing(Grounding)line
Powerline
Controlline
Connection cable preparation
Keeptheearth(ground)wirelongerthantheotherwires.
Earth(Ground)wire
20mm
Powersupplycableor
Transmissioncable
30mmormore
Wiring procedure
(1) Servicecoverremoval
Removethetwomountingscrews.
Removetheservicecoverbypushingdownwards.
Directionofthe
servicecover
removal
Hook(3places)
Servicecover
(2) Valvecoverremoval.
•Removetheonemountingscrew.
•Removethevalvecoverbyslidingupward.
Hook(4places)
Valvecover
(3) Connectthepowersupplycableandtheconnectioncabletoterminal.
(4) Fastenthepowersupplycableandconnectioncablewithcableclamp.
NL321
Terminalblocks
Firmlysecure
cableclampso
wireterminations
willnotreceive
externalstress.
Usethespecied
wiretypeand
connectitsecurely.
Cableclamp
Cableclamp
Controlbox
Connectioncable
Powersupplycable
Terminalblocks
Indoor
unit
EARTH
3.10. Demand control
WARNING
DonotturnONthepoweruntilallworkhasbeencompleted.TurningONthepower
beforetheworkiscompletedcancauseseriousaccidentssuchaselectricshockorre.
Ensurethatanyelectricalinstallationiscompletedbyaqualiedperson.
EnsuretheelectricalinstallationisinstalledinaccordancewithAS/NZS3000.
(1)Removetheservicepanelandvalvecoveroftheoutdoorunit.
Valvecover
Servicepanel
(2)Passthesignaltransmissioncableasshowninthegure.
Signaltransmissioncable
(3)Connectthesignal transmissioncable(eld-supplied)tothe demandcontrolsignal
terminalblock.
1:DRM1
2:DRM2
3:DRM3
C:COMMON
20
15
(mm)
㪈㪉㪊㪚
NOTE:Conrmthateachwiresofthesignal
transmissioncablearermlyconnectedto
correspondingterminaloftheterminalblock
tothedemandcontrolsignalterminalblock.
9374995639-02_IM.indd 10 7/8/2019 08:57:16
En-11
(4)Putthecabletiewithclipintotheholesonthespacer.
Cabletiewithclip
(5)Fixthesignaltransmissioncablewiththecabletie(withclip).
Thencutofftheredundantendofthecabletie(withclip).
㪈㪉㪊㪚
(6)SecuretheEMIcoretothesignaltransmissioncablebyusingthecabletie(small).
EMIcore
Cable-tie(small)
0-10
(mm)
(7)AttachtheInsulationtotheEMIcore.
Insulation
(8)Reinstalltheservicepanelandvalvecover.
NOTE: Donotpinchthesignaltransmissioncablewiththevalvecover.
CAUTION
Routethesignaltransmissioncableawayfromthepowersupplycable.
Adjacentwiringofthosecablesmayleadtheproductmalfunctionscausedbygenerated
noise.
• Whentestingtheoperationofthedemandcontrolmodes,ensuretheairconditioner
anddemandcontrolPCBhasbeeninstalledinaccordancewiththeprovided
installationmanuals.
• EnquirieswhentestingtheoperationofthedemandcontrolPCB:
ConsultFujitsuCustomerServiceandyourenergyproviderifyouhaveanyoperational
issuesorerrorsarecaused.
3.11. Protection for the intrusion of small animals
WARNING
Removethegapofthepowersupplycableandconnectioncableinlet.Ifsmallanimals
suchasinsectsentertheexternalunit,ashortcircuitmaybecausednearelectrical
componentsintheservicepanel.
1.Removethecoverplate.
Coverplate
Insulation(seal)
2. Fixthepowersupplycableandconnectioncablewiththecableclipofthebaseofthe
valves.
Powersupplycableand
connectioncable
Cableclip
3.Attachthecoverplate.
Coverplate
CAUTION
Fixcablessothatcablesdonotmakecontactwiththepipes(especiallyonhigh
pressureside).
Donotmakepowersupplycableandconnectioncablecomeincontactwithvalve
(Gas).
Powersupplycable
andconnectioncable
Valve
(Gas)
Gap
9374995639-02_IM.indd 11 7/8/2019 08:57:24
En-12
4. TEST RUN
CAUTION
Alwaysturnonthepower12hourspriortothestartoftheoperationinorderto
ensurecompressorprotection.
MakeaTESTRUNinaccordancewiththeinstallationinstructionsheetfortheindoorunit.
5. FINISHING
WARNING
Installtheinsulatedpipessothattheydonottouchthecompressor.
5.1. Installing insulation
• DeterminethethicknessoftheinsulationmaterialbyreferringtoTableA.
Table A, Selection of insulation
(for using an insulation material with equal heat transmission rate or below
0.040 W/(m·k))
Relative humidity
[mm (in.)]
Insulation material
Minimum thickness [mm]
70%
or more
75%
or more
80%
or more
85%
or more
Pipe
diameter
9.52(3/8) 9 11 14 18
15.88(5/8) 10 12 16 20
Iftheambienttemperatureandrelativehumidityexceed32°C,increasethelevelofheat
insulationfortherefrigerantpipes.
6. PUMP DOWN
PUMP DOWN (Refrigerant collecting operation)
Performthefollowingprocedurestocollecttherefrigerantwhenmovingtheindoorunitor
theoutdoorunit.
(1) Closethe3-wayvalve(Liquid).
(2) Pressthepush-buttonswitchonthecircuitboardonce.
TheLEDonthecircuitboardstartslighting.ThisindicatesthestartofPUMPDOWN
operation.
(3) PUMPDOWNoperationcontinuesforabout1minute.
Thenclosethe3-wayvalve(Gas)immediately.
Thecompressorstopsautomatically.
(4)Turnthepoweroff.
PUMPDOWNSW
WARNING
Thispart(Chokecoil)generateshighvoltages.Nevertouchthispart.
Nevertouchelectricalcomponentssuchastheterminalblocksexceptthebuttonon
thedisplayboard.Itmaycauseaseriousaccidentsuchaselectricshock.
Duringthepump-downoperation,makesurethatthecompressoristurnedoff
beforeyouremovetherefrigerantpiping.
Donotremovetheconnectionpipewhilethecompressorisinoperationwith3-way
valveopen.Thismaycauseabnormalpressureintherefrigerationcyclethatleads
tobreakageandeveninjury.
CAUTION
Performthepumpdownoperationbeforedisconnectinganyrefrigerantpipeor
electriccable.
Collectrefrigerantfromtheserviceportorthe3-wayvalveifpumpdowncannotbe
performed.
Incaseofgroupcontrolsysteminstallation,disconnectallremotecontrollercables
beforestartingthepumpdownoperation.
(Groupcontrolsysteminstallationisdescribedin“SPECIALINSTALLATION
METHODS”intheinstallationmanualoftheindoorunit.)
Pleasechecktherefrigerantcircuitforanyleaksbeforestartingthepumpdown
operation.
Donotproceedwiththepumpdownoperationifthereisnorefrigerantleftinthe
circuitduetobentorbrokenpiping.
9374995639-02_IM.indd 12 7/8/2019 08:57:32
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Fujitsu AOTG30KMTC Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI