ADTRAN Total Access 908e Installation guide

Category
Gateways/controllers
Type
Installation guide

ADTRAN Total Access 908e is a powerful networking device that offers a wide range of features for businesses of all sizes. With its intuitive web-based GUI and comprehensive CLI, the 908e is easy to configure and manage. It supports both traditional analog phone lines (FXO) and digital T1/PRI connections, making it ideal for businesses that need to connect to a variety of devices. The 908e also includes advanced features such as IP routing, firewall protection, and VPN support, making it a versatile solution for businesses of all sizes.

ADTRAN Total Access 908e is a powerful networking device that offers a wide range of features for businesses of all sizes. With its intuitive web-based GUI and comprehensive CLI, the 908e is easy to configure and manage. It supports both traditional analog phone lines (FXO) and digital T1/PRI connections, making it ideal for businesses that need to connect to a variety of devices. The 908e also includes advanced features such as IP routing, firewall protection, and VPN support, making it a versatile solution for businesses of all sizes.

Quick Start Guide, 64240916L1-13B, November 2006 Copyright © 2006 ADTRAN, All Rights Reserved
For more detailed documentation, visit us online at www.adtran.com.
Quick Start Guide
®
Total Access 900e Series P/N 4240908L1, 4240916L1, 4240924L1, 4240924L2
GETTING STARTED
Two configuration methods are available for your Total Access 900e Series unit:
Web-based GUI
AOS Command Line Interface (CLI)
The GUI lets you configure the main unit settings and provides online guidance and
explanations for each setting. However, using the AOS CLI may be necessary for more
advanced configurations.
ACCESS THE GUI
You may access the web-based GUI from any web browser on your network by following these
steps:
1. Connect the unit to your PC using the ETH 0/1 port on the rear panel of the unit.
2. Set your PC to a fixed IP address of 10.10.10.2. If you cannot change the PC’s IP address,
you will need to change the unit’s IP address using the CLI. (Refer to the next two sections
for instructions.)
3. Enter the unit’s IP address in your browser address line. The default IP address is
10.10.10.1.
4. You will then be prompted for the username and password (the default settings are admin
and password).
5. The initial GUI screen appears.
ACCESS THE CLI
Access the AOS CLI via the CRAFT port or a Telnet session. To establish a connection to the
Total Access unit CRAFT port, you need the following items:
VT100 terminal or PC (with VT100 terminal emulation software)
Straight-through serial cable with a DB-9 (male) connector on one end and the appropriate
interface for your terminal or PC communication port on the other end
1. Connect the DB-9 (male) connector of your serial cable to the CRAFT port on the rear
panel of the unit.
2. Connect the other end of the serial cable to the terminal or PC.
3. Insert the connector of the provided power cord into the power interface on the rear panel
of the unit, and plug the cord into a standard electrical outlet.
4. Once the unit is powered up, open a VT100 terminal session using the following settings:
9600 baud, 8 data bits, no parity bits, and 1 stop bit. Press <Enter> to activate the AOS
CLI.
5. Enter enable at the > prompt.Enter the enable password when prompted. The default
password is password.
CONFIGURE THE UNITS IP ADDRESS
The following steps create and IP address and subnet mask for the ETH 0/1. If you are not sure what IP
address to assign, please contact your network administrator.
1. At the # prompt, enter config terminal.
2. At the (config)# prompt, enter interface eth 0/1 to access the configuration parameters for the
ETH 0/1 Ethernet port located on the rear of the unit.
3. Enter ip address 10.26.12.12
255.255.255.0 to assign an IP address to the Ethernet port using a
24-bit subnet mask.
4. Enter no shutdown to activate the interface to pass data.
5. Enter exit to exit the interface commands and return to the Global configuration mode.
ENABLE TELNET ACCESS
The following steps create a password of adtran for Telnet access. By default, Telnet access is enabled
with a password of password.
1. Verify that the prompt of your unit displays (config)#.
2. Enter line telnet 0 4 to change the configuration parameters for the Telnet sessions.
3. Enter login to initiate Telnet access.
4. Enter password adtran
to change the login password for the Telnet sessions.
5. Enter exit to return to the Global Configuration mode.
6. Verify that the prompt of your unit displays (config)#.
7. Enter do write memory to save the current configuration.
The configuration parameters used in the examples outlined in this
document are for instructional purposes only. Please replace all
underlined entries (
example) with your specific parameters to configure
your application.
Depending on your configuration, you may need to set a default gateway as well
as using the (config)#ip default gateway command. If IP routing is enabled on
the unit, do NOT set a default gateway.
Quick Start Guide, 64240916L1-13B, November 2006 Copyright © 2006 ADTRAN, All Rights Reserved
For more detailed documentation, visit us online at www.adtran.com.
Quick Start Guide
®
Total Access 900e Series P/N 4240908L1, 4240916L1, 4240924L1, 4240924L2
NET 1 (T1 0/1) THROUGH NET 4 (T1 0/4) PINOUTS
10/100BASET (ETH 0/1, ETH 0/2) PINOUTS
FXO CONNECTOR (FXO 0/0) PINOUTS
Pin Name Description
1 R1 Receive data from the network (Ring 1)
2 T1 Receive data from the network (Tip 1)
3 Unused
4 R Transmit data toward the network (Ring)
5 T Transmit data toward the network (Tip)
6-8 Unused
Pin Name Description
1 TX1 Transmit Positive
2 TX2 Transmit Negative
3 RX1 Receive Positive
4, 5 Unused
6 RX2 Receive Negative
7, 8 Unused
Pin Name Description
1-3 Unused
4 Ring Ring lead of the 2-wire interface
5 Tip Tip lead of the 2-wire interface
6-8 Unused
CRAFT PINOUTS
VOICE CONNECTION
A single 50-pin female amphenol connector provides the interconnect wiring for the analog circuits
(FXS or FXO). Refer to the Total Access 900e Series Hardware Installation Guide on the ADTRAN
OS System Documentation CD for pinout details.
BATTERY BACKUP CONNECTION
An optional battery backup system (P/N 1175044L1/L2) is available for the Total Access 900e
Series. for more information on this connection for your specific battery backup unit, refer to the
documentation provided on the ADTRAN OS System Documentation CD included in your shipment.
CONFIGURE YOUR APPLICATION
More detailed documentation for configuring your ADTRAN unit is provided on the ADTRAN OS
System Documentation CD included in your shipment. For more detail on hardware setup, refer to
the appropriate Hardware Installation Guide. For more detail on configuring your system, refer to the
ADTRAN Operating System (AOS) Command Reference Guide, configuration guides, and technical
support notes.
Pin Name Description
1 DCD Data Carrier Detect (output)
2 RD Receive Data (output)
3 TD Transmitted Data (input)
4 DTR Data Terminal Ready (input)
5 GND Ground - connected to unit chassis
6 DSR Data Set Ready (output)
7 RTS Request To Send - flow control (input)
8 CTS Clear To Send - flow control (output)
9 RI Ring Indicate (output)
Important: For additional details on product features, specifications,
installation, and safety, refer to the appropriate Hardware Installation
Guide on the ADTRAN OS System Documentation CD shipped with the
base unit and available online at www.adtran.com.
  • Page 1 1
  • Page 2 2

ADTRAN Total Access 908e Installation guide

Category
Gateways/controllers
Type
Installation guide

ADTRAN Total Access 908e is a powerful networking device that offers a wide range of features for businesses of all sizes. With its intuitive web-based GUI and comprehensive CLI, the 908e is easy to configure and manage. It supports both traditional analog phone lines (FXO) and digital T1/PRI connections, making it ideal for businesses that need to connect to a variety of devices. The 908e also includes advanced features such as IP routing, firewall protection, and VPN support, making it a versatile solution for businesses of all sizes.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI