Saba SBB-24-72B User manual

Type
User manual
TABLE OF CONTENTS
Safety
Electrical
Disposal
Installation
Sealing Cabinet to Floor
Start Up
Cleaning the Condenser Coil
Maintenance & Cleaning
Stainless Steel Care & Cleaning
Introduction
SAFETY
When using electrical appliances basic safety precautions should be followed:
• This cooler must be properly installed and located in accordance with the Installation
service representative.
• Do not allow children to climb, stand or hang on the shelves in the cooler. They could
damage the unit and seriously injure themselves.
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
• Unplug the unit from the electrical outlet before cleaning or making repairs.
• Setting the temperature controls to the 0 (zero) position does not remove power to the
light circuit, perimeter heaters or evaporator fans.
NOTE: It is strongly recommended that any servicing be performed by an authorized
instructions before it is used.
PROPER DISPOSAL OF EQUIPMENT
Child entrapment and suffocation are not problems of the past. Junked or
DANGER! RISK OF CHILD ENTRAPMENT
abandoned refrigerators are still dangerous . . . even if they will sit for
“just a few days.” If you are getting rid of an old refrigerator, please follow
the below instructions to help prevent a terrible accident.
• Remove the doors
• Leave shelves in place to prevent children from easily climbing inside.
REFRIGERANT DISPOSAL
Your old refrigerator may have a cooling system that used “ozone depleting”
chemicals. If you are throwing away your old refrigerator, be sure the
refrigerant is removed for proper disposal by a qualified service technician.
If you intentionally release any refrigerants you can be subject to fines and
imprisonment under the provisions of the environmental regulations.
INSTALLATION
Removing bracket from skid Removing bracket from cabinet
Tools required: Phillips screw driver.
• Use a phillips screw driver to remove the four (4) screws from the L-bracket connecting
the unit to the wood skid (see image 1). Then remove the L-bracket from the unit (see
image 2).
Image 1
Image 2
• Remove skid by unscrewing all base rail anchor brackets. Place skid to the side.
• Carefully upright cabinet.
When lifting unit do not use the countertop as a lifting point.
Also remember to leave cabinet upright for 24-hours before plugging into power source.
• Set unit in its final location. Make sure there is adequate ventilation in this location.
Under extreme heat conditions (+100°F / +38°C) an exhaust fan may be necessary.
• Proper leveling of the unit is critical to operating success (for non-mobile models).
Effective condensate removal and door operation will be affected by leveling.
• The cooler should be leveled front to back and side to side with a level.
Warning: Installation without proper ventilation will void the manufacturer’s warranty.
ELECTRICAL
Do not under any circumstances cut or remove the grounding prong from the power
• The power cord of this cooler is equipped with a grounding plug which mates with a
service representative.
• If the outlet is a standard 2-prong outlet, it must be replaced with the properly
grounded wall outlet.
• Have the wall outlet and circuit checked by a qualified electrician to make sure the
outlet is properly grounded. Check the incoming voltage with a voltmeter. If the
• DO NOT USE EXTENSION CORDS. The use of extension cords to connect the
• The cooler should always be plugged into its own dedicated circuit with a voltage
rating that matches the rating plate. This provides the best performance and also
It is strongly recommended that any servicing be performed by an authorized
standard grounding wall outlet to minimize the possibility of electric shock hazard.
cord. For safety this appliance must be properly grounded at all times.
NEVER USE AN ADAPTER PLUG!
prevents overloading wiring circuits which could become a fire hazard from over-
heated wires.
cooler will void the Metalfrio warranty. The unit must be close enough to the
• Never unplug your cooler by pulling on the power cord. Always grip the plug firmly
and pull straight out from the outlet.
• Repair or replace immediately all power cords that have become frayed or otherwise
damaged. Do not use a power cord that has cracks or abrasion damage along its
length or at either of its ends.
• When removing the cooler away from the wall be careful not to run over or damage
the power cord.
results are anything less than 100% of the rated voltage for operation is noted,
it must be corrected immediately.
WARNING: Compressor warranties are voided if compressor burns out due to
low voltage.
NOTE: Wiring diagram can be referenced by removing the front louvered grill,
and looking on the inside cabinet wall.
electrical supply so that extension cords are never used.
SEALING CABINET TO FLOOR
Step 1 - Position Cabinet
A Postion level in the inside floor of the unit near the door. Level should be parallel
to cabinet front.
• Draw an outline on the base of the floor.
Allow one (1) inch between the wall and rear of the refrigerated bar equipment to
• Raise and block the rear of the cabinet.
• Examine to see that the cabinet is sealed to floor around entire perimeter.
assure proper ventilation.
Step 2 - Level Cabinet
Cabinet should be level side to side and front to back. Place a carpenter’s level in
the interior cabinet floor in four places:
B Postion level at the inside rear of cabinet. Level should be placed parallel to
cabinet back.
C Perform similar procedures to steps A and B by placing the level on inside floor
left and right sides parallel to the depth of the cooler. Level cabinet.
Step 3 - Applying Sealant
• Raise and block the front side of the cabinet.
Apply a bead of NSF Approved Sealant (see list below) to floor half an inch inside
the outline drawn. The bead must be heavy enough to seal the entire cabinet
surface when it set down on the sealant.
Apply sealant on floor as outlined above on other 3 sides.
NSF APPROVED SEALANTS:
Minnesota Mining #ECU800 Caulk
Minnesota Mining #ECU2185 Caulk
Minnesota Mining #ECU1055 Bead
Minnesota Mining #ECU1202 Bead
Armstrong Cork - Rubber Caulk
Products Research Co #5000 Rubber Caulk
GE Silicone Sealer
Dow Corning Silicone Sealer
NOTE:
Asphalt floors are very susceptible to chemical attack. A layer of tape on
the floor prior to applying the sealant will protect the floor.
START UP
• Temperature control set at #4 position gives the cooler an approximate temperature
of 35°F. Allow unit to function several hours, completely cooling cabinet before
Plug in the cooler and the compressor is ready to operate.
changing the control setting
• Excessive tampering with the control could lead to service difficulties. Should it
ever become necessary to replace the temperature control it should be ordered
from your dealer or recommended service agent.
• Good air flow in your cooler is critical. Be careful to load product so that it neither
presses against the back wall nor comes within four (4) inches of the evaporator
housing. Refrigerated air off the coil must circulate down the back wall.
LIGHT SWITCH LOCATION:
The switch is located on the front of the evaporator housing toward the right of the
cabinet. Open the front door
NOTE:
If the unit is disconnected or shut off, wait five (5) minutes before re-starting unit.
RECOMMENDATION
Before loading product the unit should be run for 2 to 3 days. This allows confirmation
that the electrical wiring and installation are correct and no shipping damage has
occurred. Remember that the factory warranty does not cover product loss.
REPLACEMENT PARTS
We maintains a record of the cabinet model number and serial number
for your cooler. If at any time during the life of your cooler a replacement part is
needed, call the factory office with the model number and serial number of your unit
to place an order for the part.
MAINTENANCE AND CLEANING
Condensers accumulate dirt and dust and require cleaning every 30 days.
Dirty condensers result in compressor failure, product loss, and lost sales --
which are not covered by warranty.
If you keep the condenser clean you will minimize your service expense and lower
your electrical costs. The condenser requires scheduled cleaning every days or as
needed. A dirty condenser can result in non-warranted part and compressor
Air is pulled through the condenser continuously along with dust, lint, grease, etc.
failures and product loss.
or vacuuming the condenser with a shop vac or using Co2, nitrogen or pressurized air.
If you cannot remove the debris adequately please call you refrigeration service
company.
Proper cleaning involves removing debris from the condenser by using a soft brush
On most of the reach-in units the condenser is accessible at the rear of the unit. You
must remove the cabinet grill to expose the condenser. The condenser looks like a
group of vertical fins. You need to be able to see through the condenser for the unit
to function at maximum capacity. Do not place filter material in front of condensing coil.
This material blocks air flow to the coil which is similar to having a dirty coil.
CLEANING THE CONDENSER COIL
Required Tools
• Phillips screwdriver
• Stiff bristle brush
Adjustable wrench
When using electrical appliances basic safety precautions should be followed.
• Disconnect power to unit.
• Take off lower grill assembly by removing all screws.
• Remove bolts anchoring compressor assembly to frame rails and carefully slide out --
tube connections are flexible.
• Clean off accumulated dirt from condensing coil with the stiff bristle brush.
• Lift cardboard cover above fan at plastic plugs and carefully clean condenser coil
and fan blades.
After brushing condenser coil, vacuum dirt from coil and interior floor.
• Replace cardboard cover, carefully slide compressor assembly back into position
and replace bolts.
• Reinstall louver assembly onto unit with appropriate fasteners and clips. Tighten
all screws.
• Connect unit to power and check to see if condenser is running.
STAINLESS STEEL CARE AND CLEANING
CAUTION: Do not use any steel wool, abrasive or chlorine based products to
clean stainless steel surfaces.
Stainless Steel Enemies
and allow corrosion to occur.
There are three basic items that can break down stainless steel’s passivity layer
8 Steps that can help prevent rust on stainless steel
• Clean along the polish lines. Polish lines or grain are visible on some stainless steel.
• Water treatment. To reduce deposits, use soft water whenever possible. Installation
• Maintain cleanliness of food equipment. Use cleaners at recommended strength
(alkaline, alkaline chlorinated or non-chloride). Avoid buildup of hard stains by
• Hydrochloric acid (muriatic acid) should never be used on stainless steel.
• Regularly restore/passivate stainless steel.
• Scratches from wire brushes, metal scrapers and steel pads are just a few examples
of items that can be abrasive to stainless steel’s surface.
• Deposits left on stainless steel can leave spots. Hard water can leave spots. Hard
water that is heated can leave deposits if left to sit for too long. These deposits can
cause the passive layer to break down and rust stainless steel. All deposits left
from food prep or service should be removed as quickly as possible.
• Chlorides are present in table salt, food and water. Household and industrial
cleaners are the worst type of chlorides to use.
• Use the correct cleaning tools. Use non-abrasive tools when cleaning your stainless
steel products. The stainless steel’s passive layer will not be harmed by soft cloths
and plastic scouring pads.
Always scrub parallel to visible lines. Use a plastic scouring pad or soft cloth when
grain is not visible.
• Use alkaline, alkaline chlorinated or non-chloride containing cleaners. While many
traditional cleaners are loaded with chlorides, the industry is providing an ever
increasing choice of non-chloride cleaners. If unsure of chloride content contact the
cleaner supplier. If present cleaner contains chlorides, ask for an alternative. Avoid
cleaners containing quaternary salts as they can attack stainless steel causing
pitting and rusting.
of certain filters can be an advantage. Contact a treatment specialist about proper
water treatment.
cleaning frequently
• When using chlorinated cleaners you must rinse and wipe dry immediately. It is
better to wipe standing cleaning agents and water as soon as possible. All stainless
steel equipment to air dry. Oxygen helps maintain the passivity film on stainless steel.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Saba SBB-24-72B User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI