Table of Contents
v
[us] | 08/2020 | 5100059253 | E3000 | Operator’s manual
6.5 Setting and Checking the Electrodes................................................................................................... 53
6.6 Replacing the Burner Nozzle ............................................................................................................... 55
6.7 Setting the "Z" Distance ....................................................................................................................... 57
6.8 Adjusting the Air Settings..................................................................................................................... 58
6.9 Adjusting the Fuel Pressure................................................................................................................. 59
6.10 Factory Settings—Gas......................................................................................................................... 60
6.11 Restrictions for Connecting the Gas Supply ........................................................................................ 60
6.12 Setting Up the Burner—Gas ................................................................................................................ 61
6.13 Removing the Combustion Head......................................................................................................... 63
6.14 Adjusting the Ionization Probe and the Electrode................................................................................ 65
6.15 Changing the Burner Orifice ................................................................................................................ 66
6.16 Changing the Burner Diaphragm ......................................................................................................... 66
6.17 Checking the Burner Air Damper Setting............................................................................................. 68
6.18 Adjusting the Head Setting .................................................................................................................. 68
6.19 Checking the Supply Gas Pressure..................................................................................................... 70
6.20 Checking and Adjusting the Burner Gas Pressure .............................................................................. 71
7 Operation
7.1 External Components .......................................................................................................................... 73
7.2 Internal Components ........................................................................................................................... 74
7.3 Rear Components................................................................................................................................ 75
7.4 Pumps, Gauges, and Valves ............................................................................................................... 76
7.5 Control Panel ....................................................................................................................................... 77
7.6 Control Panel Components.................................................................................................................. 77
7.7 Breaking in the Generator.................................................................................................................... 78
7.8 Checking the Heat Transfer Fluid (HTF) Level .................................................................................... 78
7.9 Recommended Fuels and Fuel Blending Guide .................................................................................. 79
7.10 Before Starting Checks........................................................................................................................ 80
7.11 Starting, Operating, Stopping the Machine—Kohler............................................................................ 82
7.12 Preheating the Heat Transfer Fluid (HTF) ........................................................................................... 84
7.13 Initiating Heat Transfer Fluid (HTF) Flow............................................................................................. 85
7.14 Setting the Operating Temperature ..................................................................................................... 87
7.15 Unwinding and Positioning the Hoses ................................................................................................. 87
7.16 Hose Spacing Guidelines .................................................................................................................... 88
7.17 Monitoring the Operating Parameters.................................................................................................. 89
7.18 Rewinding the Hoses........................................................................................................................... 90
7.19 Resetting a Low HTF Fault .................................................................................................................. 92
7.20 Using the Quick-Connect Coupling...................................................................................................... 96
7.21 Operating States of the Beckett Burner Controller .............................................................................. 97
8 Accessories
8.1 Available Accessories........................................................................................................................ 101