Blaze King Clarity 2118 SP Owner's manual

Category
Stoves
Type
Owner's manual
180-CL2118.SP.1 v1.00 June 30, 2020
CLARITY CL2118.SP.1
DIRECT VENT GAS ROOM HEATER
with 7 Day Shuto Standing Pilot (SP)
For use with natural gas (NG) or propane (LPG)
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Pour la version française de nos manuels S.V.P. vous référez à notre site web: www.blazeking.com
Date Installed: ____________
Serial No.: _____________
OPERATION &
INSTALLATION
MANUAL
WARNING: If the information in these
instructions are not followed exactly, a re
or explosion may result causing property
damage, personal injury or loss of life.
PFS Report #
F19-559
180-CL2118.SP.1 v1.00 June 30, 2020
Page 2
CL2118.SP.1
SAFETY PRECAUTIONS _________________________________________________________________ 4
GENERAL .................................................................................................................................................................... 4
YOUR SAFETY .......................................................................................................................................................... 5
INSTALLATION ..........................................................................................................................................................5
GENERAL INFORMATION ________________________________________________________________ 6
APPLIANCE CERTIFICATION ..............................................................................................................................6
INSTALLATION CODES .........................................................................................................................................6
SPECIFICATIONS.....................................................................................................................................................6
HIGH ALTITUDE INSTALLATION .....................................................................................................................6
CERTIFICATION LABEL __________________________________________________________________ 7
DIMENSIONS _____________________________________________________________________________ 8
CLEARANCE TO COMBUSTIBLES ...................................................................................................................8
LIGHTING INSTRUCTIONS _______________________________________________________________ 9
820 NOVA VALVE_________________________________________________________________________ 10
OPERATING INSTRUCTIONS ____________________________________________________________ 11
PILOT LIGHT ..............................................................................................................................................................11
LIGHTING THE BURNER ......................................................................................................................................11
OPTIONAL BLOWER...............................................................................................................................................11
MAINTENANCE and SERVICE____________________________________________________________ 12
ROUTINE MAINTENANCE .................................................................................................................................... 12
CLEANING SURFACES .........................................................................................................................................12
CLEANING THE GLASS .........................................................................................................................................12
GLASS DOOR REMOVAL .....................................................................................................................................13
GLASS DOOR REPLACEMENT ..........................................................................................................................14
BURNER REMOVAL ................................................................................................................................................ 14
SAFETY SCREEN REPLACEMENT ..................................................................................................................15
FUEL CONVERSION ...............................................................................................................................................16
INSTALLATION PLANNING _______________________________________________________________ 18
PRECAUTIONS .........................................................................................................................................................18
FRAMING - ROUGH OPENING ........................................................................................................................... 18
FRAMING - CORNER INSTALLTION .................................................................................................................19
WALL FINISH..............................................................................................................................................................20
CRACKING WALL FINISHES ...............................................................................................................................21
INSTALLATION ___________________________________________________________________________ 22
HARDWIRING FOR OPTIONAL BLOWER ......................................................................................................22
OPTIONAL BLOWER INSTALLATION FOR EXISTING CL2118 INSTALLATION ...............................23
INITIAL SETUP ..........................................................................................................................................................24
VENT TERMINATION LOCATION .......................................................................................................................25
REAR VENT INSTALLATION ................................................................................................................................ 26
CONVERSION TO REAR VENT .......................................................................................................................... 26
GAS CONNECTIONS .............................................................................................................................................. 29
VENTING .....................................................................................................................................................................31
TYPICAL VENTING EXAMPLES .........................................................................................................................32
VERTICAL VENT INSTALLATION ....................................................................................................................... 33
TABLE OF CONTENTS
180-CL2118.SP.1 v1.00 June 30, 2020
Page 3
CL2118.SP.1
Manufactured By
Valley Comfort Systems Inc.
1290 Commercial Way
Penticton, BC V2A 3H5
CANADA
Phone: 250-493-7444
Fax: 250-493-5833
Blaze King Industries
146 A Street
Walla Walla, WA 99362
U.S.A.
Phone: (509) 522-2730
Fax: (509) 522-9803
SAFETY PRECAUTIONS
VENT TERMINATION RESTRICTIONS ............................................................................................................35
VENT RESTRICTOR ...............................................................................................................................................37
AIR SHUTTER ADJUSTMENT ............................................................................................................................. 38
BURNER FLAME APPEARANCE .......................................................................................................................38
MOBILE HOME INSTALLATION .......................................................................................................................... 39
ELECTRICAL REQUIREMENTS: ........................................................................................................................39
RIGID VENTING PARTS LIST _____________________________________________________________ 42
VALVE REMOVAL & INSTALLATION _____________________________________________________ 49
PARTS LIST ______________________________________________________________________________ 50
TROUBLESHOOTING ____________________________________________________________________ 51
WARRANTY ______________________________________________________________________________ 52
NOTES ___________________________________________________________________________________ 56
180-CL2118.SP.1 v1.00 June 30, 2020
Page 4
CL2118.SP.1
SAFETY PRECAUTIONS
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings
exactly could result in serious injury,
death, or property damage.
Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Leave the premises.
Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call
the re department.
Installation and service must be
performed by a qualied installer, service
agency or the gas supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certied
kit is used.
A safety screen designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed for the protection of
children and other at-risk individuals. If the safety
screen becomes damaged, the safety screen shall be
replaced with the manufacturer’s safety screen for this
appliance.
NOTE: Failure to follow these instructions could cause a malfunction of the replace, which could result in death, serious bodily injury, and/or
property damage.
GENERAL
Installation and repair should be done by a qualied service person. The appliance should be inspected before the rst use and, at least,
annually by a qualied service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.
It is imperative the control compartments, burners and circulating air passageways of the appliance be kept clean.
If the CLARITY CL2118 is pulled out of its installation, and the vent-air intake pipes is disconnected for any reason, ensure that the vent-air
intake pipes are reconnected and re-sealed in accordance to the instructions noted in INSTALLATION - VERTICAL VENT INSTALLATION
or REAR VENT INSTALLATION.
Due to high temperatures, the appliance should be located out of high trac areas and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface
temperatures and should stay away to avoid burn or clothing ignition.
Young children should be carefully supervised when in the same room as the appliance. Toddlers, young children and others may be
susceptible to accidental contact burns. A physical barrier (safety screen) is required if there are at risk individuals in the house. To restrict
access to a replace or stove install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room
and away from hot surfaces. Any safety screen, guard, or barrier removed for servicing an appliance must be replaced prior to operating
the appliance.
Clothing or other ammable materials should not be placed on or near the appliance.
CALIFORNIA PROPOSITION 65
WARNING: This product can expose you to chemicals including
benzene, which is known to the State of California to cause cancer and birth
defects or other reproductive harm. For more information:
www.P65Warnings.ca.gov
180-CL2118.SP.1 v1.00 June 30, 2020
Page 5
CL2118.SP.1
SAFETY PRECAUTIONS
YOUR SAFETY
Have the venting system inspected annually by a qualied installer for blockage and signs of deterioration.
To prevent injury, do not allow anyone who is unfamiliar with the stove to operate it.
To prevent injury, if the pilot or pilot and burners have gone out on their own, open the glass door and wait 5
minutes to air out before attempting to relight the stove.
Always keep the area around these appliances clear of combustible material, gasoline and other ammable
liquids and vapors.
These appliances should not be used as a drying rack for clothing or for hanging Christmas stockings/
decorations.
Due to the paint curing on the stove, a faint odor and slight smoking will likely be noticed when the stove is
rst used. Open a window until the smoking stops.
Do not use this appliance if any part has been under water. Immediately call a qualied service technician
to inspect the appliance and to replace any part of the control system and any gas control which has been
under water.
Do not abuse the glass by striking it or slamming the door shut.
INSTALLATION
Installation and service must be performed by a qualied installer, service agency or gas supplier
Only doors certied with the appliance shall be used. (see door part numbers in “PARTS LIST”)
This installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 / NFPA 54 in the US, or the Natural Gas and Propane Installation Code, CSA B149.1 in
Canada.
A manufactured home (USA only) or mobile home OEM installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not
applicable, the Standard for Manufactured Home Installations, ANSI / NCSBCS A225.1, or Standard for Gas
Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
Always connect this gas appliance to a vent system and vent to the outside of the building envelope. Never
vent to another room or inside the building. Make sure the specied vent pipe is used, properly sized and of
adequate height to provide sucient draft.
The ow of combustion and ventilation air must not be obstructed .
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
This gas appliance must not be connected to a chimney ue serving a separate solid-fuel burning appliance.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI / NFPA 70, in the US, or the Canadian
Electrical Code, CSA C22.1, in Canada.
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing.
FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THE DIAGRAMS IN THIS BOOKLET,
OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE, MAY
RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY.
DO NOT OPERATE WITH THE GLASS FRONT REMOVED, CRACKED OR BROKEN. REPLACEMENT
OF THE GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON.
180-CL2118.SP.1 v1.00 June 30, 2020
Page 6
CL2118.SP.1
SPECIFICATIONS
MODEL
CL2118.SP
Natural Gas (NG) Propane (LPG)
Manifold Pressure 3.8” w.c. (0.95kPa) 10.6” w.c. (2.64 kPa)
Min. Supply Pressure for
Purpose of Input Adjustment
7” w.c. (1.74 kPa) 11.0” w.c. (2.74 kPa)
Orice Size DMS #39 DMS #1.5 mm
Nominal Input Rating 27,300 BTU/hr 26,200 BTU/hr
Minimum Input Rating 14,838 BTU/hr 14,120 BTU/hr
Altitude 0 - 4,500 ft. (0 - 1372 m) 0 - 4,500 ft. (0 - 1372 m)
Primary Air Opening 50% (Minimum) open
Electrical Rating 120 V.A.C. System 120 V.A.C. System
HIGH ALTITUDE INSTALLATION
When installing this appliance beyond 4500 ft. (1372 m) above sea level, the appliance must be properly de-
rated and installed according to local codes, in the absence of local codes, with the current National Fuel Gas
Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code, CSA-B149.1, in Canada.
GENERAL INFORMATION
INSTALLATION CODES
This appliance must be installed by a qualied gas
appliance installer. This appliance is certied for installation
in a bedroom or a bedsitting room. This appliance is only
for use with the type of gas indicated on the rating plate and
may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by
local codes. This appliance is not convertible for use with
other gases, unless a certied kit is used. Only for direct
discharge without duct connection. This appliance must
be direct vented using listed and approved Simpson Dura-
Vent, Selkirk, Security or American Metal Products vent
components.
We recommend
that our gas hearth
products be installed
and serviced by
professionals who are
certied in the U.S. by
the National Fireplace
Institute (NFI) as NFI
Gas Specialists.
APPLIANCE CERTIFICATION
This appliance is tested and certied to the following US and Canadian gas appliance standards:
ANSI Z21.88-2017 / CSA 2.33-2017 - Vented Gas Fireplace Heaters
CAN/CSA 2.17-2017 - Gas-Fired Appliance for Use at High Altitudes
CSA P.4.1-15 - Testing Method for Measuring Annual Fireplace Eciency
STEADY STATE EFFICIENCY
Steady State Eciency - High Ey
SS,H
71.01%
Fireplace Eciency FE 60.72%
180-CL2118.SP.1 v1.00 June 30, 2020
Page 7
CL2118.SP.1
CERTIFICATION LABEL
Model: Clarity CL2118 top vent appliance
Modèle: Clarity CL2118 appareil de ventilation vers le haut
oNATURAL GAS oLP GAS
Orice (DMS) 0-1372 m 39 1.5 mm
Input rating / Puissance d’entrée (BTU/hr / Kw ) 0-1370m 0-4,500 ft Alt.
Minimum Input / Entrée Minimum (BTU/hr / Kw)
Manifold Pressure High setting / Manifold Pression réglé à High (In w.c. / kPa)
Manifold Pressure Low setting / Manifold Pression réglé à Low (In w.c. / kPa)
Minimum Inlet Pressure / Pression minimum d'admission (In w.c. / kPa)
27,300 / 8.00
14,838 / 4.35
3.8 / 0.95
1.0 / 0.25
7.0 / 1.74
26,200 / 7.68
14,120 / 4.14
10.6 / 2.64
2.9 /0.72
11.0 / 2.74
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1 / NFPA 54, or the Natural
Gas and Propane Installation Code, CSA B149.1.
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage Refer to the owner's manual
provided with this appliance. For assistance or additional information consult a qualied installer, service agency, or the gas supplier.
Hot while in operation. Do not touch. Keep children, clothing, furniture, gasoline and other liquids having ammable vapors away. Keep burner and
control compartment clean. See installation and operating instructions accompanying appliance. VENTED GAS FIREPLACE HEATER —NOT FOR
USE WITH SOLID FUEL. For use with glass doors certied with the appliance only. Do not operate this appliance with glass removed, cracked or
broken. Replacement of the panel(s) should only be done by a qualied person. For use only with barrier Part No. 645.1821. Also for use in OEM /
mobile(manufactured) homes after home is on site. Convertible for use with natural gas or propane as follows: For natural gas when equipped with
orice #39; For propane when equipped with orice 1.5 mm. May be installed in a bedroom or sitting room when installed with a listed thermostat control
in Canada.
CLARITY CL2118.SP o CLARITY CL2118.IPI o
Listed vented gas replace heater / Poêle certié au gaz avec évacuation
MODEL / MODÈLE: Clarity CL2118 top venting appliance / Clarity CL2118 appareil ventilé vers le haut
This stove is factory equipped for 0-1372 m (0-4500 ft) / Ce poêle est manufacturé et équipé pour 0-1372 m (0-4500 pied)
UNITED STATES AND CANADA / ÉTATS-UNIS ET LE CANADA: Conforms to ANSI Z21.88-2017; Certied to CSA 2.33-2017 - Vented Gas
Fireplace Heater ,CSA 2.17-2017 - Gas-Fired Appliance For Use At High Altitudes. Conforme à ANSI Z21.88-2017; Certié CSA 2.33-2017 -
Poêle au gaz avec évent et CSA 2.17-2017 - Appareils de chauage au gaz utilisés en hautes altitudes.
SN - 26.
Cet appareil doit être installé selon les codes locaux, s’il y en a: sinon suivez l’actuel ANSI Z223.1 / NFPA 54 ou Gaz Naturel et Propane Codes, CSA
B149.1.
MISE EN GARDE: Une mauvaise installation, un ajustement, une altération, service ou entretien peuvent causer des blessures ou des dommages à la
propriété. Consultez le manuel du propriétaire fourni avec cet appareil. Pour assistance ou information additionnelle, consultez un installateur qualié,
agence de service ou votre fournisseur de gaz. Chaud lorsque l’appareil fonctionne. Ne pas toucher. Tenir loin des enfants, vêtements, meubles, essence
et autres liquides ayant des vapeurs inammables. Tenir le compartiment du brûleur et de contrôle propre. Voir les instructions de l’installation et du
fonctionnement accompagnant cet appareil. FOYER AU GAZ AVEC ÉVENT —NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE. Utiliser seulement
avec des portes vitrées certiées pour cet appareil. Ne pas opérer cet appareil, si la vitre est manquante, craquée, ou brisée. Le remplacement des
panneaux de verre seulement être fait par une personne qualiée. À utiliser uniquement avec le numéro de pièce de barrière 645.1821. Aussi pour l'usage
dans les maisons mobiles (manufacturées) après que la maison soit installée sur le site. Pouvant être converti pour usage avec le gaz naturel ou le
propane comme suit: Pour le gaz naturel une fois équipé d'un orice # 39.; Pour le propane une fois équipé de l'orice # 1.5 mm. Peut être installé dans
une chambre à coucher ou un salon une fois installé avec un thermostat approuvé au Canada.
MINIMUM CLEARANCES TO COMBUSTIBLES /
DÉGAGEMENTS MINIMUM REQUIS ENTRE L’APPAREIL ET DES MATÉRIAUX COMBUSTIBLES
Unit to sidewall / de l’unité au mur latéral 4” (102 mm)
Unit to back wall / de l’unité au mur arrière 4” (102 mm)
Unit corner to sidewall / du coin de l’unité au mur latéral 4” (102 mm)
Unit to ceiling (top vent & rear vent with snorkel) /
de l’unité jusqu’en haut (évacuation sur le dessus et par l’arrière avec ens, périscopique (snorkel))
32” (813 mm )
Unit to ceiling (2' up & out vent) / unité jusqu’en haut (2’ au- dessus et au- dessous de l’évacuation) 45” (1143 mm )
Vertical Vent / verticale évacuation murale extérieure
1” (25 mm) from outside surface / de la surface
extérieure
Horizontal Vent / horizontal évacuation murale extérieure
13" (330 mm) above / au dessus
2.5" (64 mm) beside / à côté de
1" (26 mm) below / au dessous de
Floor clearance / Dégagements pour la surface de plancher 0" (0 mm)
NOTE: CHECK LOCAL CODES FOR FLOOR REQUIREMENTS. THIS FIREPLACE IS SUITABLE FOR INSTALLATION ON A COMBUSTIBLE SURFACE.
VÉRIFIER LES CODES LOCAUX POUR ÉQUIPEMENT DE SURFACE DE PLANCHER, CET APPAREIL PEUT ÊTRE INSTALLÉ SUR UNE SURFACE COMBUSTIBLE
PFS Report#
F19-559
Electrical Rating: 115 Volts, 0.7 Amp, 60 Hz
DANGER: Risk of electrical shock. Disconnect power before servicing unit. Do not route power cord beneath heater. This appliance must be installed
in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title
24CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI / NCSBCSA 225.1 / NFPA501A, Manufactured Home Installations
Standard. This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,
manufactured(mobile) home where not prohibited by local codes. See owners manual for details. This appliance is not convertible for use with other
gases unless a certied kit is used. This vented gas replace is not for use with air lters.
Caractéristiques électriques: 115 Volts, 0.7 Amp, 60 Hz
DANGER: Risque d’électrocution. Débrancher le courant avant de réparer l’unité. Ne pas mettre le cordon d’alimentation en dessous de l’appareil de
chauage. Cet appareil doit être installé selon les codes CAN/CSA Z240 MH, maisons mobiles (manufacturées), au Canada, sinon applicable, utilisez ANSI
/ NCSBCS A225.1/NFPA 501 A, Installation d’une maison mobile standard.
Cet appareil peut être utilisé seulement avec le type de gaz indiqué sur la plaque de contrôle et peut être installé dans un marché des accessoires, maison
(mobile) de manière permanente placée et manufacturée où ils ne sont pas interdit par des codes. Voir le manuel d’installation pour des détails. Cet
appareil ne peut pas être converti pour l'usage avec d'autres gaz à moins qu'un kit de conversion certié soit employé. Ce foyer au gaz à évacuation ne
pas être utilisé avec des ltres à air.
MANUFACTURED IN:
o USA: Blaze King Industries 146A Street, Walla Walla, WA. 99362
o CANADA: Valley Comfort Systems 1290 Commercial Way, Penticton, B.C. V2A 3H5
CSA P.4.1-15 Fireplace Eciency (FE) / Ecacité énergetique des foyer (EEF) CSA P.4.1-15:
CL2118.IPI Natural Gas / Gaz naturel: 62.04%
CL2118.SP Natural Gas / Gaz naturel: 60.72%
MANUFACTURE DATE
JAN o FEB o MAR o APR o MAY o JUN o
JUL o AUG o SEP o OCT o NOV o DEC o
2020 o 2021 o 2022 o 2023 o 2024 o 2025 o
170-0250 [01 20]
180-CL2118.SP.1 v1.00 June 30, 2020
Page 8
CL2118.SP.1
29
1
2
"
27
1
8
"
18
3
4
"
16
3
8
"
28
1
4
"
17
1
4
"
3
7
8
"
16
3
4
"
13"
1
2
"
FRONT FACING OFFSETS
16
3
8
"
15
3
4
"
7
8
"
1
1
2
"
25
1
2
"
VERT
VENT
8
1
2
"
2"
21
7
8
"
REAR
VENT
GAS
INLET
OPTIONAL
ELECTRICAL
ACCESS
26
3
8
"
8
1
2
"
2"
13"
3
7
8
"
OPTIONAL
GAS INLET
OPENING
ELECTRICAL
ACCESS
NOTE: TURNING ON YOUR APPLIANCE WHEN IT HAS BEEN OFF FOR AWHILE MAY CAUSE CONDENSATION
TO APPEAR ON THE GLASS. THIS IS A NORMAL OCCURRENCE AS YOUR APPLIANCE HEATS UP.
CLEARANCE TO COMBUSTIBLES
Side of unit to sidewall 4” (102 mm)
Back of unit to back wall 4” (102 mm)
Corner of unit to sidewall 4” (102 mm)
Top of unit to ceiling (top vent & rear vent with snorkel) 32” (813 mm)
Top of unit to ceiling (2’0” up and out vent) 45” (1143 mm)
Vertical Vent 1” (25 mm) from outside surface
Horizontal Vent
13” (330 mm) above / au dessus
2.5” (64 mm) beside / à côté de
1” (26 mm) below / au dessous de
Floor clearance 0” (0 mm)
DIMENSIONS
180-CL2118.SP.1 v1.00 June 30, 2020
Page 9
CL2118.SP.1
WARNING: If you do not follow these instructions exactly, a  re or explosion may result
causing property damage, personal injury or loss of life.
FOR YOUR SAFETY, READ BEFORE LIGHTING
A. This appliance has a pilot which is lit with a push button piezo lighter. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the  oor
because some gas is heavier than air and will settle on the  oor.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the  re department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or
turn by hand, don’t try to repair it, call a quali ed service technician. Force or attempted repair may result
in a  re or explosion.
D Do not use this appliance if any part has been under water. Immediately call a quali ed service technician
to inspect the appliance and to replace any part of the control system and any gas control which has been
under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Set the thermostat to the lowest setting.
3. Valve controls are accessed by lowering the hinged panel that is below the  rebox.
4. Set the manual burner switch to the “OFF” position.
5. Push in gas control knob slightly and turn clockwise
to “OFF”.
6. Wait  ve (5) minutes to clear out any gas. Then smell for gas, including near the  oor. If you smell gas,
STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.
7. Turn control knob counterclockwise
to “PILOT” position.
8. Depress control knob and push in Piezo ignitor button. Once pilot ignites, continue to hold the control
knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up.
Pilot should remain lit. If it goes out, repeat steps 6 through 8.
If knob does not pop up when released, stop and immediately call your service technician or gas
supplier.
If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service
technician or gas supplier.
9. Turn gas control knob counter clockwise
to “ON”. Turn on all electric power to the appliance. Set
thermostat to the desired setting or set the manual burner switch to the “ON” position.
TO TURN OFF GAS TO THE APPLIANCE
1. Set the thermostat to the lowest setting.
2. Turn o all electric power to the appliance if service is to be performed.
3. Push in gas control knob slightly and turn clockwise
to “OFF”. Do not force.
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause injury
or property damage. Refer to the owner’s
information manual provided with this appliance.
For assistance or additional information, consult
a quali ed installer, service agency or your gas
supplier.
170-0360 [03 18]
LIGHTING INSTRUCTIONS
180-CL2118.SP.1 v1.00 June 30, 2020
Page 10
CL2118.SP.1
820 NOVA VALVE
AE
P
I
L
O
T
TP TH
TP
TH
1
5
15
6
7
8
2
3
4
9
10
11
13
14
12
820 NOVA VALVE
1 ON/PILOT/OFF Knob
2 Manual HI-LO adjustment or pressure regulator adjustment
3 Pilot adjustment
4 Thermocouple connection
5 Mounting for piezo & bracket
6 Inlet pressure test point
7 Outlet pressure test point
8 Main operator
9 Pilot outlet
10 Main gas outlet
11 Flange mounting screw holes
12 Additional valve mounting holes
13 Alternative TC connection point
14 Thermoelectric unit
15 Inlet
180-CL2118.SP.1 v1.00 June 30, 2020
Page 11
CL2118.SP.1
OPERATING INSTRUCTIONS
PILOT LIGHT
Refer to the lighting instruction label on how to light
the pilot. Check that the pilot has fully engulfed the
thermocouple assembly (Fig.1).
LIGHTING THE BURNER
Standing Pilot (SP)
The CLARITY CL2118 SP controls are located behind
the hinged ap beneath the rebox.(Fig.2) To light
the burner follow the steps below:
1. Make sure the pilot is lit (see “LIGHTING
INSTRUCTIONS Standing Pilot”)
2. Turn the “Valve Control” knob counterclockwise
to ON.
3. Flip the ame ON/OFF switch, located beside the
igniter to ON.(Fig.3)
4. Turn the “Flame Height” knob to the desired
ame height.(Fig.2)
5. Turn on all electrical power to the unit.
6. NOTE: Burn the appliance on high, with the
optional blower OFF, for the rst two to three
hours. This will cure all the paint, gasket, and
seals. It is advised to open a door or window
as the unit will smoke and give o odors as it is
curing.
OPTIONAL BLOWER
An optional blower is available for the CLARITY
CL2118 SP and CLARITY CL2118 IPI, the S.Z5277.
SP and S.Z5277.IPI blower kits respectively. For
installation refer to the installation instructions
provided with the kit.
Turn the blower on by turning the “Fan speed
knob clockwise .(Fig.2) The blower will only
come on when the replace is up to temperature
(approximately 10-15 minutes). Fan speed control
sequence is o, then maximum to minimum. The
speed of the fan can be decreased by turning the
knob clockwise . The speed of the fan can be
increased by turning the knob counterclockwise
. The blower will continue to operate after the burner
is turned o (approximately 15-20 minutes). To turn
the blower o manually, turn the fan control knob
counterclockwise until it “clicks”.
Fig.2
Fig.3
Fig.1
180-CL2118.SP.1 v1.00 June 30, 2020
Page 12
CL2118.SP.1
MAINTENANCE and SERVICE
ROUTINE MAINTENANCE
Regularly:
Clean and remove any lint accumulations or debris from the grills and combustion or convection air
passage ways.
Keep the appliance area free from combustible materials, such as paper, wood, clothing, gasoline,
ammable solids, liquids and vapors.
Visually check the height and color of the burner and pilot ames. The pilot ame should be blue with
little or no yellow on the tips.
Check for unusual noises or odors during operation of the appliance.
Check the vent terminal for any damage, or obstruction by plants or debris accumulation.
It is recommended to periodically have your appliance serviced by a qualied service technician:
1. Remove the glass door (see “GLASS DOOR REMOVAL” on next page) and clean the inside of the
glass with a soft, non-abrasive cloth and water or a suitable, mild, non-abrasive cleaner.
2. Remove and clean the glass oor panel and set aside.
3. Remove and clean the oor panel assembly, check the burner to see if all the ports are clear and clean.
Check the pilot assembly to make sure it is not blocked by anything. Use a vacuum to clear out any
debris around the burner and valve.
4. Completely inspect the appliance and the venting system.
5. Check the safety system of the gas valve.
CLEANING SURFACES
Painted, powder coated, or porcelain enameled surfaces should be wiped with a damp cloth periodically.
Ensure the appliance has cooled down completely before any cleaning. Do not use other cleaners as they
may leave a residue which can become permanently etched into the surface.
CLEANING THE GLASS
DO NOT TO CLEAN THE GLASS WHILE IT IS HOT
One of the by-products of combustion and moisture in the rebox is a white lm which can show up on the
glass of the viewing door. Initial curing of the appliance can also leave a slight lm on the glass, which is a
temporary problem.
1. Turn o the appliance and allow it to cool down completely.
2. Remove the glass door from the rebox (see “GLASS DOOR REMOVAL” on next page)
3. Check the gasket material on the back of the glass. Ensure that it is attached and intact.
4. Clean the glass with a mild glass cleaner and a soft cloth (see below). Abrasive cleaners will damage
the glass
Slight soiling of SCHOTT ROBAX® panels can be removed using conventional glass cleaning products,
provided they are used according to instructions of use, which means cleaning on cold surfaces. The residues
should be removed since chemical attack is possible on exposure to temperature. The coated ROBAX®
Mirror, ROBAX® TrueView, ROBAX® IR Max and ROBAX® Energy Plus can be cleaned with a soft cloth.
NOTE: IT IS NOT RECOMMENDED TO USE SCOURING PADS, ABRASIVE CLEANSERS OR SCOURING
AGENTS, AS MAY CAUSE DAMAGE TO THE GLASS SURFACE. THE SCHOTT-RECOMMENDED DRY
WIPER IS SUITABLE FOR USE ONLY ON UNCOATED FIRE VIEWING PANELS.
180-CL2118.SP.1 v1.00 June 30, 2020
Page 13
CL2118.SP.1
MAINTENANCE and SERVICE
GLASS DOOR REMOVAL
For installation, cleaning, and burner removal the
glass door must be removed.
1. Turn o the appliance and allow it to cool
down completely.
2. Lift the face trim up and out, away from the
appliance, and set it aside.(Fig.4)
3. Lift the safety screen up and out, away
from the appliance, and set it aside. (Fig.5)
4. There are two door latch mechanisms on
top of the glass door.(Fig.6) Pull the tabs
forward and up o the door tabs.
Fig.4
Fig.5
Fig.6
180-CL2118.SP.1 v1.00 June 30, 2020
Page 14
CL2118.SP.1
5. Carefully slide the door glass assembly up
and out of the unit.(Fig.7)
GLASS DOOR REPLACEMENT
This glass in this appliance is a 5 mm high
temperature ceramic glass that will easily
withstand the heat that is produced. In the event
the glass breaks or cracks, contact your dealer
to arrange for your glass door replaced with a
factory replacement (see “PARTS LIST”). Do
not operate this appliance with the glass front
removed, cracked, or broken. Removal and
replacement of the glass from the door must be
done by a qualied service technician. The glass
door must be purchased from a Blaze King dealer.
No substitute materials are allowed.
BURNER REMOVAL
1. Turn o the appliance and allow it to cool down
completely.
2. Remove the face trim, safety screen, and glass
door. (see “GLASS DOOR REMOVAL” on
previoius page)
3. Remove the glass oor plate and set it aside.
(Fig.8)
4. Remove the oor plate assembly and set it
aside.(Fig.8)
5. Remove the screw from the left hand side of
the burner assembly.(Fig.9)
6. Move the burner to the right, up, and out.
To re-install the burner follow steps 1 to 7 in
reverse. Ensure the burner is centered in the
curved burner slot of the oor plate.
Fig.7
Fig.8
GLASS FLOOR PLATE
FLOOR PLATE
Fig.9
SCREW
BURNER
MAINTENANCE and SERVICE
180-CL2118.SP.1 v1.00 June 30, 2020
Page 15
CL2118.SP.1
MAINTENANCE and SERVICE
SAFETY SCREEN REPLACEMENT
The CLARITY CL2118 is supplied with a safety
screen pre-installed inside the door trim. If the
safety screen becomes damaged it must be
replaced with part #645.1821
1. Turn o the appliance and allow it to cool down
completely.
2. Remove the face trim and safety screen
by lifting up and out. (see “GLASS DOOR
REMOVAL”)
3. Slide the safety screen out of the frame, the
tabs may have to be adjusted. (Fig.10)
4. Slide the new safety screen in between the
frame face and the tabs. Ensure screen mesh
faces out, furthest from glass. (see image
below)
5. Hang the safety screen back into position.
6. Hang the face trim back into position.
SCREEN
MESH TO
THIS
SIDE
Fig.10
180-CL2118.SP.1 v1.00 June 30, 2020
Page 16
CL2118.SP.1
FUEL CONVERSION
THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN
ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS AND ALL APPLICABLE CODES AND
REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION. IF THE INFORMATION IN THESE
INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE, EXPLOSION OR PRODUCTION OF CARBON
MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF
LIFE. THE QUALIFIED SERVICE AGENCY IS RESPONSIBLE FOR THE PROPER INSTALLATION OF
THE KIT. THE INSTALLATION IS NOT COMPLETE UNTIL THE OPERATION OF THE CONVERTED
APPLIANCE IS CHECKED AS SPECIFIED IN THE INSTRUCTION MANUAL SUPPLIED WITH THE
KIT. BEFORE PERFORMING THIS OR ANY SERVICE PROCEDURE, MAKE SURE THAT THE GAS
SUPPLY TO THE UNIT AND THE ELECTRICAL SUPPLY ARE SHUT OFF.
CONVERSION KIT CONTENTS
The conversion kit contains the following parts:
S.Z0760 (LPG)> #635.OR1.5 (1.5 mm orice) and LPG regulator.
S.Z0761 (NG)> #635.OR39 (#39 orice) and NG regulator.
Conversion Kit labels.
To convert from NG to LPG or reverse:
1. Turn o the appliance and allow it to cool down completely
2. Remove burner (see “BURNER REMOVAL” on previous page)
3. Replace main orice
4. Convert pilot fuel (see below)
5. Replace regulator (see next page)
How to convert CLARITY CL2118 SP Pilot orice:
1. Use a 7/16” wrench to loosen the pilot hood.
2. Push the little tab in and the little tab with hole should pop out. The hole stamp tab (LP) out is used for
Propane. The stamped tab (NA) out is for Natural Gas.
3. Re-tighten the pilot hood.
4. Fill out the fuel conversion label and ax between the two labels on the control panel door.
All valves have been pre-set and certied for installation at elevations from 0 – 4500 feet (1 – 1372m) above
sea level.
HIGH ELEVATIONS
When installing this unit at higher elevations, it is necessary to decrease the input rating by replacing the
existing burner orice with a smaller size for installations over 4500 feet (1370 m). Above 4500 ft, the
appliance input should be reduced 4% for each additional 1000 feet (305m). For the USA, derate the unit
according to the gas installation code.
MAINTENANCE and SERVICE
180-CL2118.SP.1 v1.00 June 30, 2020
Page 17
CL2118.SP.1
820 NOVA
installationi
i
n
n
s
s
t
t
r
r
u
u
c
c
t
t
i
i
o
o
n
n
s
s
HI/LO Conversion Kit
WARNING!
The installation of this conversion kit must only be undertaken by a
qualified and certified gas appliance installer.
WARNING!
This HI-LO conversion kit must ONLY be applied as part of a conversion kit
supplied by the APPLIANCE MANUFACTURER for the specific appliance, and
type of gas, being converted.
INSTALLER NOTICE. These instructions must be left with appliance.
1
2
3
4
5
6
7
This installation or replacement instruction refer to HI-LO pressure
regulator kit to be used to convert the 820 Nova Combination Gas Control
with adjustable pressure regulator into manual HI-LO. The same kit can
also be used for the conversion from LP to Natural Gas and vice versa of
the 820 Nova with manual HI-LO.
7.252.021 001
Turn control knob to the OFF position,
and shut off the gas supply to the
valve.
Using a Torx T20, or slotted screwdriver,
remove and discard the three pressure
regulator mounting screws (A), pressure
regulator tower (B), and the spring and
diaphragm assembly (C).
Ensure the rubber gasket (D), which is
prefitted as part of assembly (E), is
properly positioned and install the new
HI/LO pressure regulator assemble
using the supplied screws (F).
Tighten screws securely.
(Reference torque = 25 lb·in).
Install the enclosed identification label
(G) to the valve body where it can be
easily seen.
Apply gas to system and re-light
appliance according to manufacturers
instructions.
With the main burner “ON”, test the
new pressure regulator assembly for
leaks using a soap solution.
Relight the main burner in both the HI,
and LO positions, and verify proper
burner ignition and operation.
T
T
L
L
O
O
I
I
P
P
O
O
T
T
0
0
N
N
L
L
0
0
F
F
P
P
I
I
F
F
C
C
B
B
A
A
HI
HI
LO
LO
P
P
I
I
O
O
L
L
T
T
T
T
O
O
N
N
0
0
P
P
F
F
I
I
F
F
0
0
L
L
A
A
C
C
B
B
G
G
P
P
I
I
L
L
O
O
T
T
0
0
N
N
I
I
L
L
O
O
T
T
0
0
F
F
F
F
P
P
D
D
E
E
F
F
F
F
HI
HI
LO
LO
MAINTENANCE and SERVICE
180-CL2118.SP.1 v1.00 June 30, 2020
Page 18
CL2118.SP.1
INSTALLATION PLANNING
*
20" to 21"
(based on front
facing offsets)
28
1
4
"
26
1
2
"
METAL STUDS
* CLEARANCE TO COMBUSTIBLES
For a 2’0” vertical and 6” out vent conguration the ceiling clearance to combustibles is 71 3/8”
For a vertical vent conguration the ceiling clearance to combustibles is 58 3/8”
For a 9” horizontal to snorkel vent conguration the ceiling clearance to combustibles is 58 3/8”
FRAMING - ROUGH OPENING
The CL2118 appliance can be raised,
placed at oor level, or installed in a
corner. Please see specic framing
measurements for each situation
on the following pages. The basic
rough opening should have the
dimensions shown in Fig.11. Any
framing within specied combustion
clearances must be non-combustible
metal studs. Ensure the replace
has a strong and level surface to be
placed on. It can be made of wood
or a non-combustible material. Any
material such as studs must be non-
combustible if they are within the
clearances specied.
The gas line should be run to the
right side of the appliance, it is also
possible to run it to the left side if
needed. See “DIMENSIONS” for
gas inlet locations.
Fig.11
This section of the owner’s manual is for the use of qualied service technicians only. Fireplace placement,
hearths, and venting terminations will be covered, as well as the gas and electrical systems. Please read
SAFETY PRECAUTIONS” at the front of this manual.
PRECAUTIONS
The installation must conform to the installation codes.
This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate
ventilation air. Provide adequate clearance around air openings of the appliance. Never obstruct front
openings.
Provide adequate clearances for proper operation and servicing of the appliance.
This appliance must be properly connected to a venting system.
The venting of this appliance must be installed in a location that is free of plumbing, electrical wiring and
heating or air conditioning ducts.
Select a location that is accessible for venting.(see “ALLOWABLE TERMINATION LOCATIONS”)
180-CL2118.SP.1 v1.00 June 30, 2020
Page 19
CL2118.SP.1
INSTALLATION PLANNING
4"
102mm
4"
102mm
43
3
4
"
1112mm
43
3
4
"
1112mm
62
7
8
"
1598mm
28
1
4
"
718mm
min. to metal studs
36
1
2
"
927mm
min. to wood studs
CLEARANCE TO
COMBUSTIBLES
FRAMING - CORNER INSTALLTION
The dimensions for installing the CL2118 appliance in a corner is shown in Fig.12. Do not interfere with
the structural integrity of the walls. Shown below are minimum clearances; increasing these dimensions is
allowable as long as vent length remains in the allowable range.
Fig.12
180-CL2118.SP.1 v1.00 June 30, 2020
Page 20
CL2118.SP.1
INSTALLATION PLANNING
WALL FINISH
Non-combustible cement board. The CL2118 appliance requires a 1/2” (13 mm) thick non-combustible
cement board to be used as a wall surface immediately surrounding the unit on each side (see Fig13. below)
for minimum coverage. Extending the cement board well beyond the minimum shown will help avoid cracking
due to dierential expansion of materials. Pre-drill cement board with oversized holes and do not over-tighten
screws to avoid cracking due to heat expansion. Standard gypsum wall board may be used beyond the
perimeter of the cement board.
Non-combustible nishing over cement board. Additional non-combustible material such as tile, etc., may
be applied over top of the cement board or you may choose to leave it nished clean with no tile—see next
page. Be aware that a trim is always required and the trims will accept tile, etc. behind them up to 1” thick,
depending on appliance side ange position. Additional non-combustible nishes, if desired, may be butted up
to the trims. Finish should not cover the trims as they need to remain removable.
58 3/8" or 71 3/8"
1483 mm or 1813 mm
Min. (see FRAMING
- ROUGH OPENING)
Min.
36
1
2
"
927mm
26
1
2
"
673mm
28
1
2
"
724mm
1
2
"
13mm
thick non-combustible
cement board
32" or 45"
813 mm or 1143 mm
(see CLEARANCE
TO COMBUSTIBLES)
BOARD FLUSH WITH BOTTOM
OF APPLIANCE; ADD EXTRA
IF OVERLAPPING FRAMING
GYPSUM
BOARD UP TO
PERIMETER OF
CEMENT BOARD
CEMENT BOARD
Fig.13
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Blaze King Clarity 2118 SP Owner's manual

Category
Stoves
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI