Lovibond Single Method 56I701200 - Isothiazoline User manual

Type
User manual

Lovibond Single Method 56I701200 - Isothiazoline is a compact and portable device designed to measure Isothiazolinone in industrial water systems. It's suitable for use in open evaporative cooling systems containing various treatment chemicals and has been evaluated on water samples from such systems. The test method employed by the device has been proven to be reliable and accurate, with no significant interferences found during the evaluation process.

Here are some additional notable features and use cases of the Lovibond Single Method 56I701200 - Isothiazoline:

  • Quick and easy to use: The device utilizes a simple and straightforward testing procedure, making it accessible to users with varying levels of expertise.

Lovibond Single Method 56I701200 - Isothiazoline is a compact and portable device designed to measure Isothiazolinone in industrial water systems. It's suitable for use in open evaporative cooling systems containing various treatment chemicals and has been evaluated on water samples from such systems. The test method employed by the device has been proven to be reliable and accurate, with no significant interferences found during the evaluation process.

Here are some additional notable features and use cases of the Lovibond Single Method 56I701200 - Isothiazoline:

  • Quick and easy to use: The device utilizes a simple and straightforward testing procedure, making it accessible to users with varying levels of expertise.
Isothiazoline / 56I701200
ENMethod Reference Book1.02
Isothiazoline 56I701200
0 - 7.5 mg/L
Material
Reagents Packaging Unit Part Number
Isothiazolinone Reagent DK1 65 mL 56L046165
Isothiazolinone Reagent DK2 65 mL 56L046265
Isothiazolinone Reagent DK3 65 mL 56L046365
Isothiazolinone Reagent DK4 65 mL 56L714465
Isothiazolinone Reagent DK5 65 mL 56L046565
The following accessories are required.
Accessories Packaging Unit Part Number
Test Tube 5/10 mL + Cap 1 pc. 56A600401
Syringe, plastic, 20 mL 1 pc. 56A006501
Colour disc Isothiazolone 1 pc. AS-K31022
Application List
Cooling Water
Disinfection Control
Notes
This test is suitable for the determination of Isothiazolinone in industrial water systems.
Isothiazolinone is used as a non-oxidising biocide to control bacteria in open systems,
often in combination with a second biocide. This test has been evaluated on water
samples taken from open evaporative cooling systems containing a wide range of treat-
ment chemicals. No significant interferences were found. There are however a few points
to note when performing the analysis:
1. Coloured or turbid samples can mask the colour generated in the test. In this
instance, filter the sample using a 0.45u filter membrane to remove any suspended
material.
2. To achieve best test performance it is important to store the test reagents in a cool
place, away from direct sunlight, if possible refrigerate at + 4°C. If reagent DK5 has
been exposed to temperatures in excess of 25°C for a sustained period of time this
may cause a false positive result in the test. It is possible to check the performance
of reagent DK5 by carrying out a reagent blank. The result of which can be deducted
from the test result.
Isothiazoline / 56I701200
ENMethod Reference Book1.0 3
3. To perform the reagent blank, carry out the teston SAMPLE WATER (not tap water
or another reagent blank).The result of this test will give a true reagent blank that
can be deducted from the normal test result. Performing the reagent blank in this
way will also compensate for any interferences(should there be any) from any other
chemical in the sample. It is good analytical practice to perform a reagent blank on
any new system tested and also check reagent DK5 periodically.
4. This test will measure active Isothiazolinone. To convert this result into concentration
of dosed product, simply multiply by the appropriate factor, taking into account the
concentration of active isothiazolinone in the product.
Isothiazoline / 56I701200
ENMethod Reference Book1.04
Performing a test with the sample.
4
Add 4 drops Isothiazoli-
none DK1.
Fill up test tube with
sample to the 10 mL
mark.
Close test tube(s).
15
Mix the contents by
shaking.
Open the test tube(s). Add 15 drops Isothiazoli-
none DK2.
9
4
5
6
7
8
10
11 12
1
2
3
1 min
Close test tube(s). Invert several times to mix
the contents.
Wait for 1 minute(s) reac-
tion time.
Isothiazoline / 56I701200
ENMethod Reference Book1.0 5
17
Open the test tube(s). Add 17 drops Isothiazoli-
none DK3.
Close test tube(s).
9
4
5
6
7
8
10
11 12
1
2
3
1 min
Invert several times to mix
the contents.
Wait for 1 minute(s) reac-
tion time.
Open the test tube(s).
15
9
4
5
6
7
8
10
11 12
1
2
3
1.5 min
Add 15 drops Isothiazoli-
none DK4.
Wait for 1.5 minute(s)
reaction time.
Open the test tube(s).
3
Add 3 drops Isothiazoli-
none dK5.
Close test tube(s). Invert several times to mix
the contents.
Isothiazoline / 56I701200
ENMethod Reference Book1.06
9
4
5
6
7
8
10
11 12
1
2
3
10 sec
Wait for 10 second(s)
reaction time.
Open the test tube(s). Look down through the tube,
compare the colour produced
in the tube to the colour stan-
dards printed on the compar-
ison chart. Match to the
nearest standard and read of
the corresponding concentra-
tion value as Isothiazolinone
in mg/l (ppm).
Isothiazoline / 56I701200
ENMethod Reference Book1.0 7
Performing a reagent blank with the sample.
4
Add 4 drops Isothiazoli-
none DK1.
Fill up test tube with
sample to the 10 mL
mark.
Close test tube(s).
15
Mix the contents by
shaking.
Open the test tube(s). Add 15 drops Isothiazoli-
none DK2.
9
4
5
6
7
8
10
11 12
1
2
3
1 min
Close test tube(s). Invert several times to mix
the contents.
Wait for 1 minute(s) reac-
tion time.
Isothiazoline / 56I701200
ENMethod Reference Book1.08
17
Open the test tube(s). Add 17 drops Isothiazoli-
none DK3.
Close test tube(s).
9
4
5
6
7
8
10
11 12
1
2
3
1 min
Invert several times to mix
the contents.
Wait for 1 minute(s) reac-
tion time.
Open the test tube(s).
3
Add 3 drops Isothiazoli-
none dK5.
Close test tube(s). Invert several times to mix
the contents.
15
9
4
5
6
7
8
10
11 12
1
2
3
1.5 min
Open the test tube(s). Add 15 drops Isothiazoli-
none DK4.
Wait for 1.5 minute(s) reac-
tion time.
Isothiazoline / 56I701200
ENMethod Reference Book1.0 9
Open the test tube(s). Look down through the
tube, compare the colour
produced in the tube to the
colour standards printed
on the comparison chart.
Match to the nearest stan-
dard and read of the corre-
sponding concentration
value as Isothiazolinone in
mg/l (ppm).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Lovibond Single Method 56I701200 - Isothiazoline User manual

Type
User manual

Lovibond Single Method 56I701200 - Isothiazoline is a compact and portable device designed to measure Isothiazolinone in industrial water systems. It's suitable for use in open evaporative cooling systems containing various treatment chemicals and has been evaluated on water samples from such systems. The test method employed by the device has been proven to be reliable and accurate, with no significant interferences found during the evaluation process.

Here are some additional notable features and use cases of the Lovibond Single Method 56I701200 - Isothiazoline:

  • Quick and easy to use: The device utilizes a simple and straightforward testing procedure, making it accessible to users with varying levels of expertise.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI