Cauti on
Danger
Danger
Cauti on
Digital Color CCD Camera
Operation Manual
This Operation Manual covers safety, camera functions, installation
and the correct operating procedure for the WAT-230 VIVID. First, we
ask you to read this Operation Manual thoroughly, then install and
operate the WAT-230 VIVID as advised. In addition, for future reference,
we also advise safe keeping of this manual.
Please contact the distributor or dealer from which the WAT-230 VIVID
was purchased, if you do not understand the installation, operation
or safety instructions laid out in this manual. Not understanding the
contents of the Operation Manual sufficiently may cause damage to the
camera.
Cautions for safety
The WAT-230 VIVID is designed to be used safely; however, electrical
goods may lead to physical accident caused by fire and electric shock
if not used correctly. Therefore, please keep and read the “Cautions
for safety” for protection against accidents.
Do not disassemble and/or modify the WAT-230 VIVID.
Do not operate the WAT-230 VIVID with wet hands.
Use only the AD-603 or equivalent power adaptor for the
WAT-230 VIVID.
The recommended voltage is DC+6V±10%
Do not expose the WAT-230 VIVID to wetness or high
moisture conditions.
The WAT-230 VIVID is designed and approved for indoor use
only. The WAT-230 VIVID is not water-resistance or
waterproof. If the location of the camera is outdoors or
in an outdoor like environment, we recommend that you use
an outdoor camera housing
Protect the WAT-230 VIVID from condensation.
Keep the WAT-230 VIVID dry at all times, during storage
and operation.
Should the camera not work properly, switch off the power
immediately. Please check the camera according to the
“Trouble shooting” section.
Avoid the striking of hard objects or dropping the
WAT-230 VIVID.
The WAT-230 VIVID uses high quality electrical parts and
precision components.
Do not connect any power supply directly to the Video out
terminal of the unit.
Do not connect the WAT-230 VIVID with any monitor using
a video/power single transmission terminal. The WAT-230
VIVID is not designed for use with this type of equipment.
We also advise you to read the operation manual of the
monitor you plan to use, before any connections are made.
Do not install the WAT-230 VIVID in a position subject
to direct sunlight.
Sunlight shinning directly onto the WAT-230 VIVID lens can
cause damage to the CCD.
Select a stable place for installation of the WAT-230
VIVID.
Use a support of durable strength around an installation
position on a ceiling or wall when a camera stand or tripod
is used.
Do not move the WAT-230 VIVID with the cables connected.
Before moving the WAT-230 VIVID, always remove the video
cable and power cable from the rear of the camera first.
Avoid using the WAT-230 VIVID near any strong
electromagnetic field.
Avoid emission sources of electromagnetic waves when the
WAT-230 VIVID is installed into main equipment.
Guide to the safety symbols
The meanings of the symbols used in this operation manual are:
When you do not adhere to or take notice of the “Danger”
sign, it may lead to serious accident such as death or injury
caused by fire or electric shock.
When you do not adhere to or take notice of the “Warning”
sign, it may cause severe damage such as a physical injury.
When you do not adhere to or take notice of the “Caution”
sign, it may incur injury and cause damage to peripheral
objects in the immediate surroundings.
About EMC
The WAT-230 VIVID is in conformity with EMC test standards carried out
by authorized organizations in Japan.
NTSC FCC Part15 class B
P A L EN61000-6-3 /EN50130-4
Do not modify the WAT-230 VIVID. Modification to the camera is
dangerous and in addition, the camera will not conform to EMC test
standards.
Contents
Check to make sure all parts are present before use.
WAT-230 VIVID Connector with cables
Wiring (Video)
Make sure the power supply to the system is turned off before
installation of the WAT-230 VIVID, and then connect the power source
and video output as shown in the following diagram
【Diagram of power and video cables】
・Use only the AD-603 or equivalent power adaptor. (See specification)
・For the video output, use a coaxial cable with an impedance of 75Ω
such as an RG-59U or an RG-11U.
Check that the cables are connected correctly and then move
on to the next procedure.
War ni n g
War ni n g
To 75Ω coax. cable
for monitor
To power supply(DC+6V)
To power supply(GND)
Black: Common GND
Black: Common GND
Blue: Video out
Red: DC+6V
Danger
Danger
Dents for
lens focus
adjustment
B001
Operation and adjustments
① Connect the power supply using the correct procedure.
If there is a problem, refer to the “Trouble shooting” section.
② Make sure that a picture can be seen on the monitor.
③ To focus, turn the lens clockwise or counterclockwise while
observing the picture on the monitor.
Pinhole lenses
Focusing of the pinhole lens (type:
P3.7) can be done by turning the lens
clockwise or counterclockwise while
placing a pair of tweezers in the
focusing adjustment dents as shown
in the figure on the right.
Take care when focusing not to scratch
or damage the lens.
Trouble shooting
If any of the following, problems occur when using the
WAT-230 VIVID,
An optimal picture cannot be obtained, after checking that all the
cables and connections are correctly in place.
Smoke or any unusual odor emerges from the WAT-230 VIVID.
An object becomes embedded or enters into the camera housing or a
quantity of liquid seeps into the camera housing.
More than the recommended voltage or/and amperage has been applied
to the WAT-230 VIVID by mistake.
Anything unusual occurring to any equipment connected to the WAT-230
VIVID.
disconnect the camera immediately according to the following
procedures:
Switch off the main power supply to the camera, or remove the power
adaptor from the socket.
② Remove the power and video cables connected to the WAT-230 VIVID.
③ Contact the distributor or dealer from which the WAT-230 VIVID was
purchased.
Option 1Active Visual Mate(Parameter controller)
Selection of the functional parameters can be set as desired by using
the remote controller as follows:
Shutter speed: EI / ES
Gain: AGC / Manual
BLC: 5 selectable area settings
White balance: Fixed / Precise control
Outline enhancer: 4 steps
Gamma: 0.45 / 1.0
Video level: 75 IRE / 100 IRE
Other: Mirror image, Setup level control, Color/Monochrome
picture, and Data save/delete
The rear of the WAT-230 VIVID has a cover
protecting the connection terminal for
the Active Visual Mate (see the figure on the
right).
Do not open the cover unless using the Active Visual
mate. Damage may occur if tampered with.
Option 2【B001】(Mounting bracket)
B001 is used for mounting the WAT-230 VIVID to
stands and surfaces. The base has a
U1/4”thread for mounting on stands, and
through holes on both sides.
【Mounting】
The WAT-230 VIVID has two bosses on both
sides featuring M2×2 thread and screws.
Use these if the camera is to be mounted
to the B001 bracket.
To purchase these options and others, please contact the distributor
or dealer from which you purchased the WAT-230 VIVID.
Specifications
WAT-230 VIVID
NTSC PAL
Pick-up element 1/4 inch interline transfer CCD image sensor
Number of total pixels 768(H)×494(V) 752(H)×582(V)
Color filter Cy, Ye, Mg, G complementary color filter
Scanning system 2:1 interlaced
Horizontal scanning
frequency 15.734kHz 15.625kHz
Vertical scanning
frequency 60Hz 50Hz
Synchronizing system Internal
Video output Composite video, 1.0V(p-p), 75Ω(Unbalanced)
White balance ATW
ATW range 2500K-9500K
AGC range 24dB (6-30dB)
AES range 1/60-1/100,000 sec. 1/50-1/100,000 sec.
Resolution (H) 450TVL (Center)
S/N ratio More than 50dB (AGC OFF, γ OFF)
Minimum illumination 1.6 lx. (F2.0)
Gamma characteristics γ≒0.45
Back light compensation ON
Power supply DC+6V (5.0-7.6V)
Electric power 1.08W (typ.)
Operating temperature -10℃ - +40℃
Operating humidity Less than 95% RH (Without condensation)
Storage temperature -30℃ - +70℃
Storage humidity Less than 95% RH (Without condensation)
Size (W×H×L)
(Excluding protrusions)
G3.8 30×30×29(mm)
P3.7 30×30×13(mm)
Standard lenses G3.8 or P3.7
Cable length 300mm
Weight 35g
Design and specifications are subject to change without notice.
Watec is not responsible for any inconvenience or the attendant
damages to the video and monitoring recording equipment caused by
misuse, miss operation or improper wiring of our equipment.
If for any reason the WAT-230 VIVID does not work properly, or if
you have any questions regarding installation or operation, please
contact the distributor or dealer from which it was purchased.
Contact information
Watec Co., Ltd.
Add.: 254-2 Nihonkoku, Daihoji, Tsuruoka- Shi,
Yamagata-Ken, 997-0017 Japan
TEL: +81-235-23-4400 FAX: +81-235-23-4409
Email: info-o@watec.co.jp
URL: http://www.watec.net
M2 bosses with
thread and screw
  • Page 1 1
  • Page 2 2

Watec WAT-230 VIVID Operating instructions

Category
Security camera accessories
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI