Amana 4KAED4900BW1 Installation guide

Category
Electric laundry dryers
Type
Installation guide
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
WARNING - ...i.kofFi,o..
- Clothes dryer installation must be performed by a qualified installer.
- install the clothes dryer according to the manufacturer's instructions and local codes.
- Do not install a clothes dryer with flexible plastic venting materials or flexible metal
(foil type) duct. if flexible metal duct is installed, it must be of a specific type identified
by the appliance manufacturer as suitable for use with clothes dryers, Flexible venting
materials are known to collapse, be easily crushed, and trap lint. These conditions will
obstruct clothes dryer airflow and increase the risk of fire,
= To reduce the risk of severe injury or death, follow all installation instructions.
- Save these instructions.
FOR YOUR SAFETY
1. Do not use or store gasoline or other flammable materials in this appliance or near this appliance.
2. Do not spray aerosols in the vicinity of this appliance while it is in operation.
3. Do not modify this appliance.
2
IM PORTANT SAFETY INSTRUCTIONS
WARNING." To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic
precautions, including the following:
[] Read all instructions before using the dryer. _J_
[] Keep a minimum clearance of 100 mm (4 in.) between the
rear of the dryer and any wall.
[] The operation of this appliance may affect the operation of
other types of appliances which take their air supply for safe
combustion from the same room. There has to be adequate
ventilation to replace exhausted air and thus avoid the
back-flow of gases into the room from appliances burning
other fuels, including open fires, when operating the tumble
dryer. If in doubt, consult the appliance manufacturers.
[] Do not obstruct the air supply to the dryer (see Installation
Instructions for minimum clearances).
[] Do not place items exposed to cooking oils in your dryer.
Oil-affected items can ignite spontaneously, especially when
exposed to heat sources such as in a tumble dryer. The
items become warm causing an oxidation reaction in the oil.
Oxidation creates heat. If the heat cannot escape, the items
can become hot enough to catch fire. Piling, stacking or
storing oil-affected items can prevent heat from escaping
and so create a fire hazard.
[] If it is unavoidable to dry in the dryer items that have been
soiled with substances such as cooking oil, acetone, alcohol,
petrol, kerosene, spot removers, turpentine, waxes and wax
removers, or that have been contaminated by hair care
products, should be washed in hot water with an extra
amount of detergent before being dried in the dryer. These
items may give off vapours that could ignite or explode. Such
washing will reduce, but not eliminate, the hazard.
[] This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instructions concerning
use of the appliance by persons responsible for their safety.
[] Children should be supervised to ensure that they do not
play with the appliance.
[] The dryer should not be used if industrial chemicals have
been used for cleaning.
[] Before the dryer is removed from service or discarded,
remove the doors to the drying compartment.
[] Do not reach into the dryer if the drum is moving. A door
switch is fitted for your safety.
[] Do not install or store the dryer where it will be exposed
to the weather.
[] Do not tamper with controls.
[] Do not continue to use this appliance if it appears to be
faulty.
[] Do not repair or replace any part of the dryer or attempt
any maintenance unless specifically recommended in this
Use and Care Guide. Repairs and servicing should only
be carried out by competent service personnel.
[] Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric
softener or product. Follow their instructions.
[] Clean dryer lint screen before or after each load. Do not
operate dryer without lint screen in place.
[] Keep area around the exhaust and inlet openings and
adjacent surrounding areas free from the accumulation of
lint, dust, and dirt.
[] The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[] See Installation Instructions for earthing instructions.
[] Do not dry unwashed items in this dryer.
[] The final part of a tumble dryer cycle occurs without heat
(cool down cycle) to ensure that the items are left at a
temperature that ensures the items will not be damaged.
[] kems such as foam rubber (latex foam), shower caps,
waterproof textiles, rubber backed articles and clothes or
pillows fitted with foam rubber pads must only be dried
on a clothesline.
[] If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid a hazard.
WARNING: Never stop a tumble dryer cycle before the
end of the drying cycle unless all items are quickly removed
and spread out so that the heat is dissipated.
SAVE THESE INSTRUCTIONS
INSTALLATIONREQUIREMENTS
Tools and Parts:
Gather required tools and parts before starting installation.
@
Flat-blade screwdriver
#2 Phillips screwdriver
6,2 mm (1/4") nut driver Adjustable wrench that
opens to 25 mm (1") or a
hex-head socket
Utilityknife Tapemeasure
Pliers
Level
Caulkinggunandcompound
forinstallingnewexhaustvent
Wirestripper
(directwireinstallations)
Tinsnips
(newventinstallations)
Parts supplied (all models):
Leveling legs (4)
Parts package is located in dryer drum. Check that all parts
are included.
Parts needed: (not supplied with dryer)
[] Electric Cord and Plug
[] Vent clamps
[] Vent elbows and ductwork
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with dryers.
The kit should contain:
[] A UL listed 30-amp power supply cord, rated 240 volt
minimum. The cord should be type SRD or SRDT and be at
least 4 ft (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or spade terminals with upturned
ends.
[] A UL listed strain relief.
Additional parts may be required, depending on your installation.
Check local codes. Check existing electrical supply and venting.
Read "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
LOCATION REQUIREMENTS
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 460 mm (18 inches) above the floor
for a garage installation.
Failure to do so can result in death, explosion,
or fire.
Select proper location for your dryer to improve performance
and minimize noise. Check code requirements. Some codes limit,
or do not permit, installation of the dryer in garages, closets,
mobile homes, or sleeping quarters. Contact your local building
inspector.
You will need:
[] A location that allows for proper exhaust installation. The
dryer must be exhausted to the outdoors. See "Venting
Requirements."
[] A floor that will support the dryer and a total weight (dryer
and load) of 90,7 kg (200 Ibs). The combined weight of a
companion appliance should also be considered.
[] A level floor with maximum slope of 25 mm (1") under entire
dryer. If slope is greater than 25 mm (1"), install Extended
Dryer Feet Kit. Clothes may not tumble properly and models
with automatic sensor cycles may not operate correctly if
dryer is not level.
[] It is important to make sure the room has an adequate air
supply for drying operation. The operation of this appliance
may affect the operation of other appliances which take their
air supply for safe combustion from the same room.
[] Adequate ventilation must be provided to avoid a backflow
of gases into the room from appliances burning other
fuels, including open fires. If in doubt consult the appliance
manufacturers.
iMPORTANT: The dryer must not be installed or stored in an
area where it will be exposed to water and/or weather. Do not
operate your dryer at temperatures below 7°C (45°F). At lower
temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended. Check code
requirements. Some codes limit, or do not permit, installation of
the dryer in garages, closets, or sleeping quarters. Contact your
local building inspector.
Proper installation is your responsibility.
4
Installation clearances:
For each arrangement, consider allowing more space for ease of
installation and servicing; spacing for companion appliances and
clearances for walls, doors, and floor moldings. Space must be
large enough to allow door to fully open. Add spacing on all sides
of dryer to reduce noise transfer. If a closet door or Iouvered door
is installed, top and bottom air openings in door are required.
Dryer Dimensions
Front View:
_686 mm_
(27)
1095 mm
(431/8"}
_578 mm_
(22 3/4"}
489 mm
(191/o"}
Side View:
m
_743 rnm_
356 mm _- (29 1/4 ) r
(14")
Side View of Side Swing Door:
{101/4")
_578 mm_
(22 3/4")
_743 mm_
(29 1/4")
?-
260 mm4_
(101/4")
108 mm
(41/4'')
108 mm
(41/4 ")
Back View:
t
972 mm
{381/4'')
279 mm
,", IT
t
i
359 mm
(141/8"}
100 mm
(4"}
Recessed Area and Closet Installation
This dryer may be installed in a recessed area or closet. If
a closet door or Iouvered door is installed, the minimum
unobstructed air openings in the top and bottom of the door are
required. For recessed area and closet installations, minimum
clearances can be found on the serial tag on the dryer.
356 mm _----_1
(14"} max [........ !.....
r- ........ j .....
102mm I_%'.....
(4"} \ ""%.
f (1")
mm
"}
J
,..25mm
(1"}
76
(:
76
5 ram1
[] Dimensions shown are minimum spacings required. Consider
allowing more space for ease of installation, servicing, and
compliance with local codes and ordinances.
[] Additional spacing for companion appliances and clearances
for walls, doors, and floor moldings should also be
considered. Add spacing of 25 mm (1") on all sides of dryer
to reduce noise transfer.
[] This dryer must not be installed behind a Iockable door,
a sliding door or a door with a hinge on the opposite side
to that of the dryer.
[] The dryer must be exhausted outdoors.
[] No other fuel-burning appliance may be installed in the same
closet as the dryer.
ELECTRICAL REQUIREMENTS
ENectricaNShock Hazard
ENectrically ground this appliance.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
This dryer is supplied without an electric cord and plug.
It is your responsibility:
[] To contact a qualified electrical installer.
[] To be sure that the electrical connection is adequate and in
conformance with all local codes and ordinances.
[] To supply the required single phase, 240 volt, 60 Hz, AC
only electrical supply on a separate 30-amp circuit fused on
both sides of the line. A time-delay fuse or circuit breaker is
recommended. Connect to an individual branch circuit. Do
not have a fuse in the neutral or grounding circuit.
[] Do not use an extension cord.
[] If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Electrical Connection
To properly installyour dryer, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
if using a power supply cord:
[] If the supply cord is damaged, it must be replaced by the
manufacturer, a qualified service agent, or other qualified
person to avoid a hazard.
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
[] A UL listed 30-amp power supply cord, rated 240 volt
minimum. The cord should be type SRD or SRDT and be at
least 4 ft (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or spade terminals with upturned
ends.
[] A UL listed strain relief.
Connecting by direct wire:
Power supply cable must match power supply and be:
[] Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), covered with flexible metallic conduit. All
current-carrying wires must be insulated.
[] 10-gauge solid copper wire (do not use aluminum).
[] At least 5 ft (1.52 m) long.
[] Disconnection must be incorporated in the fixed wiring in
accordance to the wiring rules for your region.
Recommended Grounding Method
[] It is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformance with all local codes and ordinances.
GROUNDING INSTRUCTIONS
m=For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.
WARNING: improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE INSTRUCTIONS
INSTALL LEVELING LEGS
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. Prepare dryer for leveling legs
To avoid damaging floor, use a large flat piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.
6
2, Screw in leveling legs
diamond
marking
Examine leveling legs, find diamond marking. Screw legs into
leg holes by hand, use a wrench to finish turning legs until
diamond marking is no longer visible.
Now stand the dryer on its feet. Slide the dryer until it is
close to its final location. Leave enough room for electrical
connection and to connect the exhaust vent.
VENTING REQUIREMENTS
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent,
Failure to follow these instructions can result in death
or fire,
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or flexible metal vent shall be used for
exhausting.
(4")
[] Only a 102 mm (4") heavy metal exhaust vent and clamps
may be used. Do not install metal vent that is smaller than
102 mm (4")in diameter.
[] Do not use plastic, non-metal, or metal foil vent.
Rigid metal vent
[] Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
[] Must be fully extended and supported in final dryer location.
[] Remove excess flexible metal vent to avoid sagging
and kinking that may result in reduced airflow and poor
performance.
[] Do not install in enclosed walls, ceilings, or floors.
[] The total length should not exceed 2.4 m (73Aft.).
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not
plugged with lint. Replace plastic or metal foil vents with rigid
metal or flexible metal vents. Review "Vent System Chart" and
if necessary, modify existing vent system to achieve best drying
performance.
Exhaust hoods:
[] Must be at least 305 mm (12")from ground or any object that
may obstruct exhaust (such asflowers, rocks, bushes, or
snow).
Recommended Styles:
Louvered Hood
Acceptable Style:
Box Hood
Angled Hood
Elbows:
[] 45° elbows provide better airflow than 90° elbows.
Bet
Clamps:
[] Use clamps to seal all joints.
[] Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
Vent products can be purchased from your dealer. For more
information, see "Assistance or Service" section in your "Use
and Care Guide."
improper venting can cause moisture and lint to collect
indoors, which may result in:
[] Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
[] Housecleaning problems and health problems.
PLAN VENT SYSTEM
The design of the flue system should ensure that any condensate
formed when operating the appliance from cold, is either retained
and subsequently evaporated or discharged. Following these
installation instructions should adequately meet this requirement.
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
A--
B
G
E. Clamps
E Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer's instructions.
Over-The-Top installation (also available with one offset elbow)
Periscope installation
If you prefer, dryer may be converted to exhaust out right side,
left side, or through bottom. You must contact your local dealer
to have dryer converted.
Determine vent path:
[] Select route that will provide straightest and most direct
path outdoors.
[] Plan installation to use fewest number of elbows and turns.
[] When using elbows or making turns, allow as much room
as possible.
[] Bend vent gradually to avoid kinking.
[] Use as few 90° turns as possible.
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
Determine vent length and elbows needed for best
drying performance:
[] Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
f
NOTE: Do not use vent runs longer than those specified
in Vent System Chart. Exhaust systems longer than those
specified will:
[] Shorten life of dryer.
[]
Reduce performance, resulting in longer drying times
and increased energy usage.
Number of
90 °turns
or elbows
2
3
4
Vent System Chart
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/Iouvered Angled
hoods hoods
15,8 m (52 ft.) 13,4 m (44 ft.)
13,4 m (44 ft.) 11,0 m (36 ft.)
11,0 m (36 ft.) 18,5 m (28 ft.)
8,2 m (27 ft.) 6,4 m (21 ft.)
6,1 m (20 ft.) 4,3 m (14 ft.
The Vent System Chart provides venting requirements that
will help achieve best drying performance.
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add
one 90° turn to the chart.
8
The maximum length using a 51 mm x 152 mm (2"x 6")
rectangular vent with 2 elbows and a 64 mm (2-1/2") exhaust
hood is 2,4 m (8 ft).
For exhaust systems not covered by the Vent System Chart (such
as multiple unit hookups, plenums, and power-assist fans), see
Service Manual. (To purchase the Service Manual, contact your
local authorized service dealer.)
INSTALLVENT SYSTEM
1, Install exhaust hood
305 rnm
(12"rain,)
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
, Connect vent to exhaust hood
I
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 102 mm (4") clamp. Run vent to dryer location
using straightest path possible. Avoid 90° turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.
CONNECT VENT
Using a 102 mm (4") clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 102 mm (4") clamp.
2, Move dryer to final location
Move dryer to final location. Avoid crushing or kinking vent.
After dryer is in place, remove corner posts and cardboard
from under the dryer.
LEVEL DRYER
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1, Level Dryer
Check levelness of dryer from side to side. Repeat from
front to back.
NOTE: The dryer must be level to reduce noise and assure
proper performance.
If legs are not long enough to level dryer, order Extended Dryer
Feet kit (sold two legs per kit), from your dealer.
Not Level LEVEL Not Level
2, Tighten and adjust leveling legs
If dryer is not level, prop up using a wood block, use wrench
to adjust legs up or down, and check again for levelness.
Once legs are level, make sure all four legs are snug against
the ground.
COMPLETE INSTALLATION
CHECKLIST
[_ Check that all parts are now installed. Ifthere is an extra
part, go back through steps to see what was skipped.
[_ Check that you have all of your tools.
[_ Dispose of/recycle all packaging materials.
[_ Check dryer's final location. Be sure vent is not crushed
or kinked.
[_ For power supply cord installation, plug into an outlet.
For direct wire installation, turn on power.
[_ Check that dryer is level. See "Level Dryer".
[_ Remove film on console and any tape remaining on dryer.
[_ Wipe dryer drum interior thoroughly with a damp cloth
to remove any dust.
[_ Read "Dryer Use" in your "Use and Care Guide."
[_ Set the dryer on a full heat cycle (not an air cycle) for
20 minutes and start the dryer.
If the dryer will not start, check the following:
[] Controls are set in a running or "On" position.
[] Start button has been pushed firmly.
[] Dryer is plugged into an outlet and/or electrical supply
is on.
[] Household fuse is intact and tight, or circuit breaker has
not tripped.
[] Dryer door is closed.
[_ When the dryer has been running for 5 minutes, open the
dryer door and feel for heat. If you feel heat, cancel cycle and
close the door.
If you do not feel heat, turn off dryer, and check the
following:
[] There may be 2 household fuses or circuit breakers for
the dryer. Check that both fuses are intact and tight,
or that both circuit breakers have not tripped. If there
is still no heat, contact a qualified technician.
NOTE: You may notice an odor when the dryer is first heated.
This odor is common when the heating element is first used.
The odor will go away.
10
REVERSE DOOR SWING (OPTIONAL)
(MODELS WITH SIDE SWINGS DOORS ONLY)
27" Wide Model Side-Swing Door
1, Place towel on dryer
Place towel on top of dryer to avoid damaging the surface.
Remove bottom screws
Open dryer door. Remove bottom screws from dryer cabinet
side of hinges. Loosen (do not remove) top screws from dryer
cabinet side of hinges.
Lift door off top screws
4, Remove screws from hinges
Remove screws attaching hinges to door.
5. Remove screws from door
\
\
\
\
Remove screws at top, bottom, and side of door (6 screws).
Keep door screws separate from hinge screws as they are
different sizes. Holding door over towel on dryer, grasp sides
of outer door and lift to separate it from inner door.
NOTE: Do not pry apart with putty knife or screwdriver.
Do not pull on door seal or plastic door catches.
6, Rotate outer door
Rotate outer door 180° and set it back down on inner door.
Be certain to keep cardboard spacer centered between
doors. Reattach outer door panel to inner door panel so
handle is on the side where hinges were just removed. Insert
6 door screws.
Lift door until top screws in dryer cabinet are in large part of
hinge slot. Pull door forward off screws. Set door (handle side
up) on top of dryer. Remove top screws from dryer cabinet.
11
7, Flip door over
Flip door over so handle side is down.
8, Attach door hinges
Reattach door hinges to dryer door so that the larger hole is
at the bottom of the hinge.
dryer cabinet
NOTE: 2 people may be needed to reinstall door.
Insert screws into the bottom holes on left side of dryer
cabinet. Tighten screws halfway. Position door so large end of
door hinge slot is over screws. Slide door up so screws are in
bottom of slots. Tighten screws. Insert and tighten top screws
in hinges.
fll, Check door strike alignment
Close door and check that door strike aligns with door catch.
If it is needed, slide door catch left or right within slot to
adjust alignment.
TROUBLESHOOTING
See the "Use and Care Guide" to possibly avoid the cost of a
service call.
Remove the 4 screws that attach 2 plugs on the left side.
Transfer plugs to opposite side using the same 4 screws.
12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Amana 4KAED4900BW1 Installation guide

Category
Electric laundry dryers
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI