Escapade

Zodiac Escapade, MX 8, MX8 Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Zodiac Escapade Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Page 2
ENGLISH
Zodiac
®
MX8
Pool Cleaner
|
Owner’s Manual
To ensure prompt warranty service, should it be required, please:
• CompleteandreturntheZodiacWarrantyCard.
• Recordyourpurchaseinformation.
• Attachacopyofyourpurchasereceipttothisdocument.
DateofPurchase:___________PurchasedFrom:__________________________________
SerialNumber(locatedunderthehood)___________________________________
Ifserviceisrequired,simplypresentyourmanualwiththeattachedreceiptatanyZodiacwarantycenter.
Forcustomerserviceorsupport:
Zodiac Pool Systems, Inc. 2620CommerceWay,Vista,CA92081-8438 1-800-822-7933
Zodiac Pool Systems Canada, Inc.
2115SouthServiceRoadWest,Unit3,OakvilleONL6L5W2Canada 1-888-647-4004
Important Information
Notice for Vinyl Liner Pools:Beforeinstallingyourpoolcleaner,examinetheinteriorofyourpoolcarefully.Ifthevinyl
linerisbrittleorhasstones,wrinkles,rootsormetalcorrosionincontactwiththeundersideoftheliner,orhasdamagetothe
basematerialorsupportingwalls,donotinstallthecleanerbeforehavingaqualifiedprofessionalperformthenecessaryrepairs
orlinerreplacement. Zodiac Pool Systems, Inc. (Zodiac) will not be responsible for liner damage caused by a cleaner
which is in disrepair, pattern removal from a vinyl liner, or a cleaner used in a pool having an aged or deteriorated liner.
PleaseseeLimitedWarranty.
• Tohelppreventsuctionentrapmentaccidents,wallvacuumfittingsshouldhaveasafetyvaclockinstalled.
Contactyourbuilderorretailpoolprofessionalfordetails.
• Cleantheskimmerbasket,pumpbasketandpoolfilterbeforeinstallingthecleanerandonaregularbasis
thereafter.
• Alwaysdisconnectthecleanerfromthepoolwallorskimmerbeforecleaningorbackwashingthepool
filter.Aftercleaningorbackwashing,letthefiltrationsystemrunforatleastfive(5)minutesbeforere-con-
nectingthecleaner.
• Removethecleanerfromthepoolbeforechemicalorshocktreatments.Waitaminimumoffour(4)hours
aftersuperchlorinationbeforere-installingthecleaner.
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED CAN RESULT IN SERIOUS
INJURY OR DEATH. Ensure that your vacuum suction fittings installed in your pool for connection of your suction-side pool
cleaner are certified as being compliant with applicable safety standards such as IAPMO SPS 4. Do not block the suction fittings with
any part or your body. Do not expose your hair, loose clothing, jewelry, etc. to any suction outlet fittings in the pool/spa.
Read owner’s manual completely before operating the cleaner.
Remove cleaner before entering the pool.
Do not operate outside of the pool.
Do not let children play with cleaner.
Page 3
ENGLISH
Owner’s Manual
|
Zodiac
®
MX8
Pool Cleaner
CongratulationsonthepurchaseofyournewMX8automaticpoolcleaner.Builtwithproventechnology,the
MX8isdesignedandmanufacturedforeasyinstallationandyearsofcarefreeoperation.Beforeinstallingthe
cleaner,pleasetakeafewmomentstobecomefamiliarwithitscomponentsandtoreviewtheitemslistedunder
Important Information.
Likemostmechanicaldevices,theMX8requiresperiodicadjustments,routinemaintenance,andthe
replacementofcertainhardworkingparts.BesuretohavetheMX8checkedoccasionallybyyourlocaldealeror
servicecenter.
AlwaysinsistongenuineZodiacreplacementparts.Non-Zodiacpartsarenotmadetoourspecifications.They
mayhaveanadverseeffectontheoperationofyourMX8ormayevendamageit.
MX8 Components (Figure 1)
a. CleanerBody
b. Flowkeeper™Valve
c. ValveCuff
d. Twist-Lock45DegreeElbow,Extended
f. Twist-Lock45DegreeElbow
Introduction
g. FlowRegulatorValve
h. LeaderHoseSectionwithHoseFloat
j. Twist-LockHoseSection(x11)
a
b
c
d
f
g
j
h
x 11
Figure 1
Page 4
ENGLISH
Zodiac
®
MX8
Pool Cleaner
|
Owner’s Manual
Installation
Prepare the Pool
1. Turnoffthepoolfilterpump.
2. Manuallyvacuumthepool,andmakesurethepoolfilterandpumpbasketareclean.
3. Closethepoolmaindrainline.
4. Aimthereturnlinefittingsdown.
Assemble and Connect the Hose
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED CAN RESULT IN SERIOUS INJURY
OR DEATH.
Ensurethatyourvacuumsuctionttingsinstalledinyourpoolforconnectionofyoursuction-side
poolcleanerarecertiedasbeingcompliantwithapplicablesafetystandardssuchasIAPMOSPS4.Donot
blockthesuctionttingswithanypartoryourbody.Donotexposeyourhair,looseclothing,jewelry,etc.toany
suctionoutletttingsorhoseendsinthepool/spa.
Assemble hose sections:
Pushandtwisttheconnectoroneachhosesectionuntiltheylockintopositionwithclickingsound.Hose
cuffshavethree(3)connectionpositions.Anyofthethree(3)positionsaresufficientforanair-tightseal.
x 11
Figure 2
Page 5
ENGLISH
Owner’s Manual
|
Zodiac
®
MX8
Pool Cleaner
Connect to a skimmer:
The FlowKeeper valve must always be used in single skimmer
installations.Thevalveregulatesflowtoensurethepoolpumpand
cleanerrunproperly.
Ifthepoolhasmorethanoneskimmer,connectthehoseto
theoneclosesttothepump.
The parts used to connect the hose and the sequence in which they are
installeddependsonthetypeofskimmer(Figure3).
1. Removetheskimmerbasket.
2. Connectthevalvecuff,FlowKeepervalveandthe45degree
elbowtogether.
3. Twistlockthemaleendofthehoseintotheendofthe45degree
elbow.
4. Inserttheskimmerpipewitharrowpointingdown.
Connect to a dedicated suction line:
1. Twistlockthemaleendofthehoseintothelargeend
oftheextended45°elbow.
2. ConnectelbowtotheinstalledSafetyVac
wallfitting(soldseparately).
3. Angletheelbowupwardtowardsthewatersurface
(Figure4).
Figure 3
Figure 4
Determine correct hose length for your pool:
1. Measureenoughhosetoreachthefarthestpointofthepoolfromtheskimmer
ordedicatedsuctionline.Removeanyadditionalhosesections,asnecessary.
See(a)inFigure5,below.
2. Nextattachtheleaderhoseattotheendwherethecleanerheadwillbe
connected.See(b)inFigure5,below.Theextralengthallowsthecleanerto
reachthefarpointinthepoolifaloopformswhileinoperation.
Leader Hose (b)
Skimmer or dedicated suction line
Farthest distance across pool (a)
Total Hose Length Required =
Farthest distance across pool
+ one hose (Leader Hose)
Figure 5
Page 6
ENGLISH
Zodiac
®
MX8
Pool Cleaner
|
Owner’s Manual
Test for Proper Flow
WARNING
To avoid serious injury, make sure to turn off the suction pump that is responsible for the pool cleaner
operation.Donotexposeyourhair,looseclothing,jewelry,etc.totheopenendofthehose.
Theflowregulatorvalveisdesignedtoconsistentlylimithighflowofwaterthroughthecleaner.Whenflowis
correct,thecleanercomponentsarelesssusceptibletodamageandthelifeofthecleanercanbeextended.
Wheelrotationspeedisagoodindicatorofhowwaterisflowingthroughthecleaner.Bycheckingforproper
wheelrotationtiming,youcanverifytheMX8isoperatingatmaximumefficiency.
Time wheel rotations:
1. Turnonthepoolfilterpump.
2. Obtainastopwatchortimer.
3. Leavingthepumponandwaterflowingthroughthe
cleaner,bringtheMX8tothesurfaceofthewaterand
holditfullysubmergedjustbelowthewaterline.
4. Locatetheyellowwheelspeedindicatoronthe
rearrightwheel(Figure8).
Connect the Cleaner
1. Attachtheflowregulatorvalvetotheleaderhose.
Leaderhoseisthehosesectionwithfoamfloat
pre-attached(Figure6).
2. Submergethecleanerandflooditwith
water.
3. Whenbubblesstopcomingfromthecleaner,
connectthehosebypushingtheflowregulator
valveontothecleaner(Figure7).
4. Allowthecleanertosinktothebottomofthepool.
5. Temporarilydisconnectthehosefromtheskimmer
ordedicatedvacuumline.
6. Turnonthepoolfilterpump.
7. Floodthehosewithwaterbyplacingtheendin
frontofoneofthepoolwaterreturninlets.
8. Turnoffthepoolfilterpump.
9. Reconnectthehosetotheskimmerordedicated
vacuumline.
Figure 6
Figure 7
Figure 8
Page 7
ENGLISH
Owner’s Manual
|
Zodiac
®
MX8
Pool Cleaner
5. Waitforthewheelstochangedirection,then
starttiminghowlongittakesforthewheelsto
rotate10times.Ifthewheelreversesduring
timing,startover.
6. Notehowmanysecondsfor10rotations.If
thecountiswithin20-25seconds,flowto
thecleanerisadequateandnoadjustmentis
necessary.
Adjust flow if necessary:
1. Determineiftheflowtothecleanerisadequate
orshouldbeadjusted.Ifthecountis:
•26-50seconds---IncreaseFlow(+)
•10-19seconds---DecreaseFlow(–)
2. UsetheFlowKeeper™valvesettingupordown,
oradjustthevalvesattheequipmentpadto
increaseordecreaseflowtothecleaneras
necessary(Figure9).
Increase Flow
Decrease Flow
Figure9
+
_
Page 8
ENGLISH
Zodiac
®
MX8
Pool Cleaner
|
Owner’s Manual
Operation and Routine Maintenance
TheMX8cycleson/offwiththepoolfiltrationpump,vacuumingandcleaningallsurfacesrandomlythroughout
thepool.Theclimbingabilityofthecleanerisdependentonthepool’sshapeandavailablewaterflow.IfMX8is
notclimbingyourwalls,ensuretheflowiscorrectbycheckingthewheelspeed.Also,ensurethepoolssurfaceis
notcoveredinalgaeasthisslipperysurfacewillaffectthecleaner’straction.
Duringeachcoveragepatterncycle,thecleanertravelsbothforwardandbackwards,andpivotstotherightand
left.Thepowerscrubbersunderneaththecleanercreatedownforceforclimbingandstabilityaswellasdirecting
debrisintothecleanermouth.
Empty the pump basket:
FortheMX8tooperateatoptimumefficiency,emptythepumpbasketregularly.Themoredebrisinthepool,the
moreoftenthepumpbasketshouldbecleared.Zodiac
®
offersanin-lineleafcanisterwhichwilltrapsolid debris
before it enters the pump basket. See your Zodiac dealer for details.
Backwash the pool filter:
AlwaysdisconnecttheMX8fromthepoolwallbeforecleaningorbackwashingthepoolfilter.Aftercleaning
orbackwashing,letthefiltrationsystemrunforatleastfive(5)minutestoflushoutthesuctionlinesbefore
re-connectingthecleaner.
Add chemicals to the pool:
Removethecleanerfromthepoolforatleastfour(4)hourswhenaddingchemicals.
Storage and winterizing:
NeverstoretheMX8indirectsunlight.Whenstoringforthewinter,drainoutallthewater(freezedamageis
notcoveredbythewarranty).Removeallconnectorsandadaptersfromthededicatedsuctionlineorskimmer.
Whenstoringthecleaner,evenforshorttimes,donotcoilthehoseasthehosemaydevelopamemorywhich
canaffectcleanerperformance.Disassemblethehosesandlayoutflat.
Page 9
ENGLISH
Owner’s Manual
|
Zodiac
®
MX8
Pool Cleaner
Remove Debris from Engine
WARNING
To avoid serious injury, make sure that the cleaner is disconnected from the hose and the suction pump used for the cleaner is turned
off prior to starting this operation.
1. Pushthelatchreleasebuttononthetopofthecleaner(Figure10).
2. Rotatethetopassemblybackuntilitclicksintoanupwardposition.
3. Lookintoengineandremovedebristhatispresent.
4. Ifneeded,slowlypushenginepaddlesforwardand/orbackwardstomovestuckdebristoanaccessible
positionthenremoveit.Whenmovingtheenginepaddles,makesurethecleanertracksareallowedtomove
freelyastheywillturnastheenginepaddlesrotate.
5. Closeenginetopandensurethelatchclicksinplace.
Latch Release
Button
Figure10
Page 10
ENGLISH
Zodiac
®
MX8
Pool Cleaner
|
Owner’s Manual
Cleaner Vacuum Modes
TheMX8PoolCleanerisdesignedtooperatewithtwovacuumoptions:
1. Small debris cleaning mode (factory setting):Forvacuumingsmallerandheavydebris,suchassand,silt
andsmallstones.Thepoolcleanerissentfromthefactoryinthismode.
2. Large debris cleaning mode:(Figure11)Forvacuuminglargedebris,suchasleaves.Itisrecommended
thatyoureturnthecleanertosmalldebrisfactorysettingafterlargedebriscleaningiscomplete(Figure12).
WARNING
To avoid serious injury, make sure that the cleaner is disconnected from the hose and the suction pump used for the cleaner is turned
off prior to starting this operation.
Inlet adaptor
Front of cleaner
Front edge
Rear edge
Cleaner with the
inlet removed
Inlet adaptor
Front of cleaner
Front edge
Rear edge
Cleaner with the
inlet removed
Convert the pool cleaner to the large
debris cleaning mode:
1. Grasptheyellowinletadapterandinserta
fingerintotheadapterhole.
2. Liftuptherearedgeoftheinletadapterand
thenpullitoutofthevacuuminlet.
Convert the cleaner back to the small
debris cleaning mode:
- Placetheyellowinletadapterinthevacuum
inletofthepoolcleaner.Pushdownonthe
yellowinletadapteruntilboththefrontandrear
edgesclickintoplace.
Figure 11
Figure 12
Page 11
ENGLISH
Owner’s Manual
|
Zodiac
®
MX8
Pool Cleaner
IfyouexperienceaproblemwithyourMX8,pleasefollowthetroubleshootingstepsbelowtorestore
performance.Iffurtherassistanceisrequired,contactZodiacTechnicalSupportDepartmentat(800)822-7933.
Troubleshooting
Problem Solution
Cleanerdoesnotmoveormovesslowly. •Confirmthatthemaindrainisclosed.
•Checkwheelspeedtoverifyproperflow.Refertosection,"Checkfor
ProperFlow."
• Backwashfilterandemptypumpbasket.
•Checkfordebrisjammedinengine.Refertosection,“RemoveDebris
fromEngine”.
• Switchcleanertolargedebriscleaningmode.Refertosection,“Pool
CleanerVacuumModes”.
•Checkforairinsystem.Ifwaterlevelinpumpbasketdropsoryousee
excessiveairbubblesinthepump
basketorcomingfromthereturnlines,thereisairinthesystem.Check
hoseconnections,tightenallfittingsatpumpandchecko-ringatpump
basketforwear.
• Checktheflowregulatorvalvetomakesuretheinternalpistoncan
movefreely.
Cleanerpatterns,doesnotcoverentirepool. • Countwheelrotationstoverifyproperflow.Refertosection,“Checkfor
ProperFlow”.Adjustflowifnecessary.
•Ensurereturnlinefittingsaredirecteddownward.Addareturndiverter
ifnecessary.
•Makesurehoseisnotkinkedorcoiled.Layinsuntostraightenif
necessary.
•Verifyhosefloatispositionedapproximately9"fromcleaner.
• Observecleanerformorethanfive(5)minutesandensurethateach
drivetrackisperiodicallyreversingdirection.Ifitisnot,contactdealer
orservicecenterforhelp.
• Confirmyoumeasuredtheproperhoselengthforyourpool.
Cleanergetsstuckatsteps. • Observecleanerformorethanfive(5)minutesandensurethateach
drivetrackisperiodicallyreversingdirection.Ifitisnot,contactyou
dealerorservicecenterforhelp.
• Ensuretheswivelontopofthecleanerrotatesfreely.
• Countwheelrotationstoverifyproperflow.Refertosection,“Checkfor
ProperFlow”.Adjustflowifnecessary.
• Confirmproperhoselength.Shortenifnecessary.
Cleanerwon’tclimbwalls. • Countwheelrotationstoverifyproperflow.Refertosection,
“CheckforProperFlow”.Adjustflowifnecessary.
•Verifyhosefloatispositionedapproximately9"fromcleaner
Cleanerridingonitsside. • Verifyhosefloatispositionedapproximately9"fromcleaner.
MX8 Spare Parts
Explodedpartsdiagramsandlistofsparepartsisavailableat:www.ZodiacPoolSystems.com
Zodiac Pool Systems, Inc.
2620 Commerce Way, Vista, CA 92081
1.800.822.7933 | www.ZodiacPoolSystems.com
ZODIAC
®
is a registered trademark of Zodiac International, S.A.S.U., used under license.
All trademarks referenced herein are the property of their respective owners.
ZODIAC
®
es una marca registrada de Zodiac International, S.A.S.U., usada bajo licencia.
Todas las otras marcas registradas usadas aqui son propiedad de sus priopietarios.
ZODIAC
®
est une marque deposée de Zodiac International, S.A.S.U., utilisée sous licence.
Toutes les autres marques citées sont la propriété respective de leur propriétaire.
Zodiac Pool Systems Canada, Inc.
2115 South Service Road West, Unit 3, Oakville, ON L6L 5W2 Canada
1.888.822.400 | www.ZodiacPoolSystems.ca
©2013 Zodiac Pool Systems, Inc. H0343700 Rev E 1309
/