Smeg KSEC70X User manual

Category
Cooker hoods
Type
User manual
Consult the designs in the front pages referenced in the text by
alphabet letters. Closely follow the instructions set out in
this manual. All responsibility, for any eventual inconveniences,
damages or fires caused by not complying with the instructions
in this manual, is declined.
The cooker hood has an upper air duct B1 and an optional rear
air duct B2*, for external fumes exit.
Select the suitable air duct and apply the flange C supplied,
ensure to close the unused hole duct with tap D* supplied if
provided.
Caution! In some models the rear hole duct is not easily
accessible, even when the tap (if mounted) is removed, in this
case remove the plastic piece E1 or E2 that is blocking the hole
duct, by unwinding using pliers and cutter. Check that the filter/
suction selector (inside the cooker hood) G is in the suction
(A) position. In the case where it is not possible to discharge
the cooking fumes externally, the cooker hood may be used in
the filter version by fixing a carbon filter, the fumes and vapours
are recycled via the anterior grill placed above the control panel.
Check that the suction/filter selector is in the filter (F)
position.
The models provided without suction motor may function only
in the suction version and must be connected to a peripheral
suction unit (not supplied).
Installation - Do not tile, grout or silicone this appliance to the wall.
Surface mounting only. Do not fix chimney flue to furniture or fly
over shelves unless the chimney flue can be easily removed,
in case maintenance is ever required.The cooker hood must be
placed at a minimum distance of 60 cm from the cooking plane
for electric cookers and 75cm for gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater
distance, this has to be taken into account.
The cooker hood may be installed on the wall or on the base
of a cabinet; if supplied, use the hole gauge H to drill the correct
distance, otherwise lean the cooker hood on the wall or on the
base of the cabinet and mark the holes with a pencil.
Wall mounting - Insert the wall screw anchors J in the drilled holes
and the two K screws in the upper drill holes, remove the grill
and hook the cooker hood to the 2 screws, finally from the inside,
insert the third screw L and lock them all in.
Cabinet fixing - Affix the cooker hood with the 4 M screws from
inside the cabinet.
Electrical connection - The electrical tension must correspond
to the tension noted on the label placed inside the cooker hood.
Connect the electrical plug, where provided, to the an easily
accessible outlet in conformity with local standards in force.
Where an electrical plug is not provided (for direct connection
to electrical network) place a standards approved bipolar switch
with an aperture distance of not less than 3mm (accessible) from
the contacts.
Operation - The control panel is situated on the front of the cooker
hood and is equipped with various suction speeds. Use the
highest speed for situations of high level vapour concentration
in cooking. Always open the vapour collector N*. It is
advisable to switch on the suction at least 5 minutes prior to
cooking and leave it in operation for 15 minutes approximately
after cooking is terminated.
Maintenance - Prior to any maintenance operation ensure that
the cooker hood is disconnected from the electrical outlet.
Cleaning - The cooker hood should be cleaned regularly
internally and externally. For cleaning use a cloth moistened
with denatured alcohol or neutral liquid detergents. Avoid
abrasive detergents.
Failure to carry out the basic standards of the cleaning of the
cooker hood and replacement of the filters may cause fire risks.
Grease Filter  may be one of the following types:
Paper filter must be replaced once a month or if coloured on
the top side, when the coloration is evident via the holes in the
grill.
Sponge filter should be washed once a month and replaced
every 5/6 washes.
Metallic filter must be cleaned once a month with suitable
detergents either by hand or in dishwasher (65°C).
When washed in a dish washer, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
In order to remove the grease filter open the grill via the P hooks
and free the R1 or R2 stoppers.
The self-supporting metal filter does not include a support
grill, in order to remove the filter  pull the release springs P4
backwards and slide the filter downwards.
Attention! the metal filter may discolour if washed in dishwasher
but the filtering performance is unaltered.
Carbon Filter - it may be one of the following types:
Rectangular S1 or S2 or S3: to be replaced every 6 months
Mounting (S1 or S2) : insert the rear side T and hook further
to the front (U).
Mounting (S3): Remove the cover W by rotating the O knobs
to 90° , then close the cover. Proceed in the inverse for
dismounting.
Circular (V1-V2-V3-various models): to be replaced every
4 months.
Bayonet mount position the filter in the middle of the motor
protection grill covering ensuring that the reference to X1 or X2
or X3 on the carbon filter match the Y1 or Y2 references on the
conveyor, then turn clockwise; in case of dismounting turn
anticlockwise, if provided with a Z tape remember to gently lift
first.
Replacing lightbulbs 40W - Unscrew the damaged light bulb and
replace with an incandescent oval light bulb with a maximum
of 40W E14. Remove the grill in order to reach the light bulb area.
Replacing the hologen bulbs - Access the light compartment 
extract the lamp cover by levering it off with a small screwdriver
or similar tool.
Warning! Prior to touching the light bulbs ensure they are cooled
down. Replace the damaged light bulb. Only use halogen bulbs
of 20W max (G4), making sure you do not touch them with your
hands. Close the lamp cover (it will snap shut).
Caution - This appliance is designed to be operated by adults.
Children should not be allowed to tamper with the controls or play
with the appliance.
Do not use the cooker hood where the grill is not correctly fixed!
The suctioned air must not be conveyed in the same channel
used for fumes discharged by appliances powered by other than
electricity. The environment must always be adequately
aerated when the cooker hood and other appliances powered
by other than electricity are used at the same time. Flambé
cooking with a cooker hood is prohibited. The use of a free flame
is damaging to the filters and may cause fire accidents, therefore
free flame cooking must be avoided. Frying of foods must be
kept under close control in order to avoid overheated oil catching
fire. Carry out fumes discharging in accordance with the
regulations in force by local laws for safety and technical
restrictions.
INSTRUCTION ON MOUNTING AND USE
GB
* Not available on all models.
Egkatastash - O aporrofhthraV prepei na ecei mia
elacisth apostash apo thn epifaneia yhsimatoV 60 cm,se
periptwsh kouzineV hlektrikeV kai 75 cm se periptwsh kouzineV
ugraeriou h mikteV.
O aporrofhthraV
mporei na egkatastaqei ston toico h sth bash enoV
ntoulapiou, ean prouparcei,crhsimopoihse ton odhgo H na
anoixeiV opeV sthn kanonikh apostash, diaforetika
akoumphse ton aporrofhthra sto toicwma h sthn bash tou
ntoulapiou kai shmeiwse me ena molubi tiV opeV pou prepei na
anoixeiV.
Staqeropoihsh sto toicwma - Eishgage ta oupa toicou
J stiV anoigmeneV opeV kai duo bideV K stiV anwtereV opeV,
afairese thn skara kai gantzwse ton aporrofhthra stiV 2
bideV kai telika apo to eswteriko eishgage thn trith bida L
kai bidwseteV oleV.
Staqeropoihsh sto ntoulapi
Staqeropoihse ton aporrofhthra me 4 bideV M apo to
eswteriko tou ntoulapiou.
O aporrofhthraV kataskeuasthke me mia exodo aera anwterh
B1 kai me mia kata zhthsh opisqia exodo B2* gia thn exagwgh
twn kapnwn proV to exwteriko periballon..
Kane thn idanikh epilogh kai efarmose thn flantza C pou
corhghtai,kleise panta thn oph pou den crhsimopoihtai me
thn tapa D* pou corhghtai, ean problepetai.
Prosoch se orismena montela h opisqia oph exagwghV den
einai ameswV eucrhsth, akoma kai an bgaloume thn tapa (ean
ecei montaristei),sauth thn periptwsh afairese to plastiko
kommati E1 h E2 pou emfrassei thn oph suromeno,
bohqoumenoi me mia labida h me ena kofth. Elegce an o diakopthV
epiloghV aporrofhshV/filtrarismatoV (sto eswteriko
tou aporrofhthra) G einai sth qesh aporrofhshV (A).Se
periptwsh pou einai adunath h exagwgh twn kapnwn kai twn
atmwn tou yhsimatoV proV to exwteriko periballon,mporei
na crhsimopoihqei o aporrofhthraV tupou
filtrarismatoV montarontaVena filtro apo anqraka,oi
kapnoi kai oi atmoi anakuklwnontai dia mesou thV
mprostinhV skaraV pou ecei topoqethqei epanw apo ton pinaka
entolwn.Elegce an o diakopthV epiloghV aporrofhshV/
filtrarismatoV einai sth qesh filtrarismatoV(F).
Ta montela cwriV kinhthra aporrofhshV leitourgoun mono
se tupo aporrofhshV kai prepei na sundeqoun se mia
periferiakh monada aporrofhshV (den parecetai).
Hlektrikh sundesh - H tash tou diktuou prepei na
antistoicei sthn tash pou anaferetai sthn carakthristikh
etiketa pou brisketai sto eswteriko tou aporrofhthra.Ean
prouparcei to fiV sundese ton aporrofhthra se mia priza
sumfwnh me touV iscuonteV kanwneV topoqethmenh se eucrhsth
perioch.
Ean den prouparcei to fiV (amesh sundesh me to diktuo )
efarmose ena dipoliko diakopth nomimo me mia apostash
metaxu twn epafwn sto anoigma oci mikroterh apo 3mm.
Leitourgeia - O pinakaV elegcou ecei topoqethqei sthn dexia
metwpikh pleura kai ecei exoplisqei apo perissotereV dunameiV
aporrofhshV.Crhsimopoihse thn megisth dunamh
aporrofhshV se periptwsh carakthristikhV sugkentrw-
shV atmwn mageirematoV.Anoixe panta ton sullekth atmwn
N*.
Sumbouleuoumai na teqei se leitourgia h aporrofhsh 5 lepta
prin na xekinhsei to mageireuma kai na afeqei se leitourgia
meta apo to teloV tou mageirematoV akoma gia 15 lepta
peripou
Kaqarisma - oaporrofhthraV prepei na kaqarizetai
sucna eswterika kai exwterika.
Gia ton kaqarismo crhsimopoihse bregmeno pani me
kaqaristiko oinopneuma h me oudeteroa ugra
aporrupantika .Apofeuge proionta pou prokaloun
katastrofeV.
H mh thrhsh twn kanonwn kaqarismou tou aporrofhthra
kai thV antikatastashV kai kaqarismou twn filtrwn
apoferei kindunouV purkagiaV.
Sunthrhsh - Prin apo kaqe sunthrhsh aposundese ton
aporrofhthra apo to reuma.
Filtro lipwn-mporei na einai enaV apo touV akolouqouV tupouV
To filtro apo carti prepei na antikatasthtai mia fora
ton mhna h an einai crwmatismeno sthn epanw pleura otan o
crwmatismoV diafenetai apo tiV opeV thV skaraV.
To filtro apo sfouggari prepei na plenetai mia fora ton
mhna kai na antikatasthtai meta apo 5/6 plusimata.
To metalliko filtro prepei na kaqarizetai mia fora ton
mhna me idanika aporrupantika sto ceri h sto plunthrio
piatwn (65°C).
Gia na fqaseiV sto filtro lipwn anoixe thn skara dia meso
twn gantzwn R kai na to eleuqerwseiV apo tiV asfaleieV R1 h
R2
To autometajeromeno metalliko jiltro den ecei scara
uposthrigmatos,gia na to metakinhseis trabhxe to elathrio
xegantzwmatos P4 pros ta pisw kai bgale to filtro
metakinoumeno pros ta katw.
Prosoch! ean pluqei sto plunthrio piatwn to metalliko
filtro mporei na allaxei crwma alla h dikh tou ikanothta
filtrarismatos paramenei ametableth.
Filtro apo anqraka - mpo rei na einai enaV apo touV
akolouqouV tupouV:
Orqogwnio S1 h S2 h S3 : Antikatasthse kaqe 6 mhneV
Montarisma (S1 h S2):Eishgage thn opisqeia pleura T
kai gantzwse to emprosqen (U)
Montarisma (S3): metakinhse to kapaki W gurizontas
kata 90° ta ceroulia O.
Bale to strwmataki anqraka mesa ston eidiko cwro kai
staqeropoihse to gurizontas kata 90° to cerouli O,
xanakleise to kapaki.
Energhse kata thn antiqeth fora gia thn aposunarmologhsh
Kukliko (V1-V2-V3-diafora montela): antikatasthse
kaqe 4 mhneV
Asfalish tupou xifologchV topoqethseto sto kentro
san skepasma thV skaraV pou profulassei ton kinhthra me
epimeleia wste ta anaforika shmeia C1 h C2 h C3 sto filtro
anqraka na antistoicoun me ta anaforika shmeia U1 h U2
tou sullekth ,meta guriseto se wrologiakh fora .Se periptwsh
aposunarmologhshV gurise se antiwrologiakh fora .An
periecei thn glwssa Z qumhsou prwta na thn anashkwseiV
elafra.
Antikatastash thV lampaV
Xebidwse thn katastramenh lampa kai antikatasthse thn
me thn nea lampa max 40WE14.Afairese thn skara gia na
fqaseiV sthn upodoch thV lampaV.
Antikatastash lampas alogonou - Phgaine sto cwro
opou brisketai h lampa - bgale to prostateutiko kalumma
kanontas moclo me ena platu mikro katsabidi h me omoio
ergaleio. Prosoch! Prin aggixeis tis lampes
bebaiwsou oti einai krues.
Antikatasthse thn katastrammenh lampa.
Crhsimopoihse mono lampes alogones twn 20W to megisto (G4)
prosecontas na mhn tis aggixeisme ta ceria. Xanakleise to
prostateutiko kalumma (staqeropoihsh me klik).
ProeidopoihseiV
Mhn crhsimopoieiV pote ton aporrofhthra an den ecei
montarisqei orqa h skara O aeraV pou aporrofate den prepei
na katalhgei se agwgo pou crhsimopoihtai gia thn exagwgh
kapnwn apo suskeueV pou trofodotountai apo energeia
diaforetikh apo thn hlektrikh.Prepei panta na problepetai
enaV kanonikoV aerismoV tou cwrou otan enaV aporrofhthraV
kai suskeueV pou trofodotountai apo energeia diaforetikh
apo hlektrikh crhsimopoiountai sugcronwV Apagoreuete
austhra to yhsimo trofwn me tiV flogeV katw apo ton
aporrofhthra.H crhsh eleuqerhV flogaV einai
katastreptikh sta filtra kai mporei na prokalesei
purkagieV,giauto prepei na apofeugetai se kaqe periptwsh.To
thganisma prepei na ginetai katw apo suneceV elegco wste to
uperqermo ladi na mhn parei fwtia.Gia tecnikouV logouV kai
gia logouV asfaleiaV prepei gia thn exagwgh twn kapnwn na
akolouqeite oti problepetai apo touV kanonismouV tiV topikhV
autodioikhshV.
GR
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Smeg KSEC70X User manual

Category
Cooker hoods
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI