Pulsar RS2266GD Operating instructions

Category
Rack accessories
Type
Operating instructions

Pulsar RS2266GD is a 22U floor-standing rack cabinet designed for integrating various systems in medium and large enterprises. Its sturdy construction ensures a static load capacity of 800 kg and protects 19'' standard devices against mechanical damage. The cabinet features adjustable front and rear rack rails, ventilation holes for efficient cooling, and cable ducts for organized cable management. The included casters and leveling feet allow for easy positioning and stability.

Pulsar RS2266GD is a 22U floor-standing rack cabinet designed for integrating various systems in medium and large enterprises. Its sturdy construction ensures a static load capacity of 800 kg and protects 19'' standard devices against mechanical damage. The cabinet features adjustable front and rear rack rails, ventilation holes for efficient cooling, and cable ducts for organized cable management. The included casters and leveling feet allow for easy positioning and stability.

INSTALLATION GUIDE
ENGLISH
code: RS2266GD
Name: RACK cabinet, floor standing, ready-to-assemble 22U/600x600
IM RS2266GD
Edition: 2 from 18.10.2013
Supersedes: 1 from 20.11.2012
EN*
1. Intended use:
The RACK 19” cabinet enables integrating CCTV, AC, I&HAS, RTV, LAN, or other systems in medium and big companies. It
is intended for devices manufactured in enclosures of the 19'' standard. Due to the RACK cabinets, the devices are aesthetically
mounted and protected against mechanical damage.
2. Specifications:
SPECIFICATIONS
Mounting dimensions:
W=19", H=22U
External dimensions:
W=600, H=1166, D=600 [mm, +/-2]
Net/gross weight:
67 / 69 [kg]
Materials:
- RACK mounting rails: cold-rolled steel SPCC 2mm RAL 9004 - bolted
- horizontal mounting rails: cold-rolled steel SPCC 1,5mm RAL 9004 - bolted
- frame: cold-rolled steel SPCC 1,2mm RAL 9004 - welded
- front door: 5mm toughened glass / SPCC 1,2mm RAL 9004 - hinged
- side panel: cold-rolled steel SPCC 1,2mm RAL 9004 - removable
- rear door: cold-rolled steel SPCC 1,2mm RAL 9004 - hinged
Static load:
800 kg (with leveling feet)
Use:
inside, IP20
Notes:
- adjustable distance between front and rear RACK rails
- ventilation holes in the front door, top and bottom panel
- possible mounting of a 2-fan tray in the top panel - RAWP600
- cable ducts in the top and bottom panel
- 4 casters without locks and 4 leveling feet included
- possible assembly of a 100mm high plinth - RAC166
- lockable front door (2 keys in set)
- lockable rear door (2 keys in set)
- side panel - lock assembly possible - RAZB16
- the possibility of installing a set of RAPU-S grounding wires in the rack
- ready-to-assemble
Certificates, declarations:
RoHS
3. Structure of the RACK cabinet.
top panel
rear door
frame
RACK rail
horizontal rail
side panel
front door
bottom panel
2” caster without lock
leveling foot
4. Assembling instructions:
The free standing, ready-to-assemble RACK cabinet is delivered in 5 separate packages.
4.1) Lay two frames of the RACK cabinet (package 2/5 and 3/5)
Fig.1
4.2) Attach the bottom panel to the cabinet’s frames from the left, and the top panel from the right (package 1/5).
Bolt with screws with nuts (16pcs - package 1/5). Bolt the casters and the leveling feet into the bottom panel of the cabinet
(package 1/5).
Fig.2
4.3) Stand the RACK cabinet.
Fig.3
4.4) From the inside of the cabinet’s frames (at front and back), mount two cage nuts on ¼ and ¾ of cabinet’s height, accordingly
to the figure below.
Fig.4
4.5) In horizontal rails (package 1/5), mount two cage nuts at front and back, as shown in Fig.4.
back front
Fig.5
4.6) Mount the horizontal rails from the inside, as shown in Fig.6.
Fig.6.
4.7) Mount the RACK rails from the inside, as in Fig.7.
Fig.7
4.8) Mount the side panels, front and rear doors - Fig.8
Fig.8
MANUFACTURER
Pulsar K.Bogusz Sp.j.
Siedlec 150,
32-744 Łapczyca
Tel. 14-610-19-40, Fax. 14-610-19-50
e-mail: biuro@pulsar.pl
www.pulsar.pl , www.zasilacze.pl
WARRANTY
12 months from the date of purchase.
THE WARRANTY IS VALID only upon presentation of the item’s proof of purchase.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Pulsar RS2266GD Operating instructions

Category
Rack accessories
Type
Operating instructions

Pulsar RS2266GD is a 22U floor-standing rack cabinet designed for integrating various systems in medium and large enterprises. Its sturdy construction ensures a static load capacity of 800 kg and protects 19'' standard devices against mechanical damage. The cabinet features adjustable front and rear rack rails, ventilation holes for efficient cooling, and cable ducts for organized cable management. The included casters and leveling feet allow for easy positioning and stability.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI