Place the fi°ame lock between the fl°ame
extensions and the window sill as shown
(Fig. 8). Drive 3/4" (19 ram) locking
screws through the frame tock and into the sill
(FIG. 9). NOTE: '[b prevent window sill from
splitting, drill 1/8" (3 ram) pilot holes before
driving screws.
Cut _i)am seal and insert in the space
between the upper and lower sashes
(FIG. 13).
IfAC is Blocked by Storm
Drive 1/2" (13 ram) tocMng screws
through frame holes into window sash
(FIG. 10/11).
"Ii) secure tower sash in place, attach right
angte sash lock with 3/4" (19 mm) screw
as shown (FIG. 12).
Add wood as shown in FIG. 14, or remove storm
window be_i)re ah: conditioner is installed.
FIG. 14 [_SASH
BOARD
STORM WINDOW THICKNESS
FRAME AS REQUIRED,
OR OTHER 1 1/2" MIN FOR PROPER
OBSTRUCTION (38 ram) , PITCH TO
REAR A ON
ENTIRE SILL.
FASTEN WITH
NAILS OR
SCREWS,
If Storm Window Frame must remain, be sure the
drain holes or slots arc not caulked or painted
shut.Accumulated Rain Water or Condensation
must be allowed to drain out.
Removing AC From
* 2k_rn AC off, and disconnect power cord.
* Remove sash seal from between windows,
and unscrew safcD_ lock.
* Remove screws installed through frame and
fl°ame lock.
* Ctose (slide) side panels into frame.
* Keeping a firm ga°ip on air conditioner, raise
sash and carefully "rock" air conditioner
backward to drain any condensate water in
base of unit. Be careful not to spill aW
remaining water while lifting unit from
window: Store parts WITH air conditioner.