Q6SD-X

Westinghouse Q6SD-X, PPH2SD Product information

  • Hello! I am an AI chatbot trained to assist you with the Westinghouse Q6SD-X Product information. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Low
Voltage
Terminals
T2
DFT
TEST
T1
T2
C
Y
O
W2
R
DFT
E
C
Y
O
W2
R
E
DF1 DF2
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
9
8
1
7
6
5
4
3
2
9
8
1
7
6
5
4
3
2
L1L2
T1T2
C
R
S
R
C
S
T2
T1
N
G
L
C
T3
T4
T5
1
5
2
6
3
4
TO 208/230 VAC
POWER SUPPLY
9
8
1
7
6
5
4
3
2
9
8
1
7
6
5
4
3
2
COMPRESSOR
DUAL CAPACITOR
HEATER
PLUG
OUTDOOR
FAN MOTOR
DEFROST
SENSOR
REVERSING
VALVE
SOLENOID
ECONOMIZER
PLUG
B
TO INDOOR
THERMOSTAT
G
ECONOMIZER
PLUG
TO DISCHARGE
AIR SENSOR
3 AMP
FUSE
BLOWER
RELAY
BLOWER
MOTOR
TRANSFORMER
24V
240V
208V
COM
CCH
(IF EQUIPPED)
BLACK
YELLOW
RED
YE
YE
YE
OR
ORANGE
CONTACTOR
F
H
C
DEFROST
BOARD
BLUE
BLACK
ORANGE
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
NOTE: ONLY
REQUIRED IF NO
LOW PRESSURE
SWITCH
BLACK
BLUE
BLACK
BLACK
BLACK
208/230 VoltConvertible Packaged Heat Pump Single Phase 60Hz
WIRING DIAGRAM
NOTES:
1. Disconnect all power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150V to ground.
4. If any of the original wire as supplied with the furnace
must be replaced, it must be replaced with wiring
material having a temperature rating of at least 105°C.
5. For supply wire ampacities overcurrent protection, see
unit rating plate.
1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs en cuivre.
3. Ne convient pas aux installations de plus de 150 V
a la terre.
7107730
02/08
DEFROST BOARD OPERATION:
1 CLOSES DURING DEFROST. RAITNG: 1 A MAXIMUM
2 OPENS DURING DEFROST. 2 HP AT 230 VAC MAXIMUM
3 CLOSED WHEN Y” IS ENERGIZED. OPEN WHEN Y” IS DEENERGIZED.
PROVIDES “OFF” DELAY TIME OF 5 MIN WHEN “Y IS DEENERGIZED.
4 WITH DTF CLOSED AND Y” ENERGIZED, COMPRESSOR RUN TIME IS ACCUMLATED.
OPENING OF DFT DURING DEFROST OR INTERVAL PERIOD RESETS THE INTERVAL TO 0.
NOTE: See Installation
Instructions for wiring,
application, and
Information concerning
accessory Heat Kits and
other options.
WHITE
WHITE
RED
RED
WHITE
RED
RED
RED
WHITE
WHITE
RED
RED
RED
RED
WHITE
YELLOW
YELLOW
YELLOW
BLUEBLUE
YELLOW
BLACKBLACK
YELLOW
YELLOW
GRAY GRAY
GREEN
BLACK
GREEN
GREEN
GREEN
WHITE
BLUE
RED
ORANGE
ORANGE
GN WITH YE STRIPE
HIGH
PRESSURE
SWITCH
LOW PRESSURE
SWITCH
(IF EQUIPPED)
YELLOW
YELLOW
BROWN
BROWN
ORANGE
BROWN
¢710773/¤
/