Simplicity 030618-00 Installation guide

Category
Power generators
Type
Installation guide

This manual is also suitable for

Simplicity 030618-00 is a portable generator that provides backup power during outages or recreational activities. It's powered by a Briggs & Stratton engine and generates up to 3,000 watts of continuous power and 3,500 surge watts. With a 4-gallon fuel tank, it can run up to 10 hours at 25% load. It features electric start with recoil backup, automatic voltage regulation (AVR) for stable power, and a low-oil shutdown to protect the engine. It also includes wheel and support leg kits for easy mobility and stability.

Simplicity 030618-00 is a portable generator that provides backup power during outages or recreational activities. It's powered by a Briggs & Stratton engine and generates up to 3,000 watts of continuous power and 3,500 surge watts. With a 4-gallon fuel tank, it can run up to 10 hours at 25% load. It features electric start with recoil backup, automatic voltage regulation (AVR) for stable power, and a low-oil shutdown to protect the engine. It also includes wheel and support leg kits for easy mobility and stability.

Attach Negative Battery Cable (model 030620 only)
Your unit may be equipped with electric start capability but can be started
manually. If you choose not to use the electric start feature, you do not
need to connect the negative battery cable. The sealed battery on the
generator is pre–installed except for the negative (black) battery cable.
1. Cut off tie wrap securing loose end of negative (black) cable.
2. Using an 8 mm socket wrench, remove screw (K), lock washer (L)
and flat washer (M) on negative battery terminal.
6
3. Slide lock washer, flat washer and negative battery cable (N) over
screw as shown.
6
4. Reattach screw to negative battery terminal and tighten.
5. Verify that connections to battery and generator are tight and secure.
Move Generator to
Safe Operating Location
1. Move generator outside to a flat, level surface, in an area that will
not accumulate deadly exhaust gas. Engine exhaust contains
carbon monoxide, a poisonous gas that could kill you in minutes. You
CANNOT smell it, see it, or taste it. Operate ONLY outside far away
from windows, doors and vents. Install carbon monoxide alarms. DO
NOT run this product inside homes or garages, even if using fans or
opening doors and windows. Direct exhaust AWAY from windows,
doors, and vents.
7
2. To reduce the risk of exhaust heat or exhaust gases igniting nearby
combustible material, keep at least 1.5 m (5 ft.) clearance on all
sides of generator, including overhead.
Start Generator
1. Make sure unit is on a level surface. Disconnect all electrical loads
from the generator.
2. Turn the fuel valve (P) to the on (I) position.
8
3. Move choke lever (Q) to choke ( ) position.
9
4. For electric start (model 030620 only), turn and hold key in start
switch (R) to start (
) position until generator starts. DO NOT hold
key in start (
) position for more than 5 seconds, and pause for at
least 1 minute between starting attempts.
10
For manual start, push on/off switch (S) to on (I) position, grasp
recoil handle (T) and pull slowly until slight resistance is felt. Then
pull rapidly one time only to start engine.
11
5. Slowly move choke lever (Q) to run position ( ) as engine warms.
9
6. If engine does not start, refer to operator’s manual for detailed
starting instructions.
Plug in Items to be Powered
1. Let engine stabilize and warm up for a few minutes after starting.
2. Plug in and turn on the desired 230 Volt AC, single phase, 50 Hz
electrical loads.
13
NOTICE Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected to it. Refer to Do
Not Overload Generator section of Operator’s Manual.
Shut Down Generator
1. Turn OFF and unplug all electrical loads from generator panel
receptacles. NEVER start or stop engine with electrical devices
plugged in and turned ON.
2. Let engine run at no-load for several minutes to stabilize internal
temperatures of engine and generator.
3. For electric start (model 030620 only), turn key (R) to Off (0)
position.
10
For manual start, push on/off switch (S) to Off (0) position.
11
4. Move fuel valve (P) to Off (0) position.
8
5. To prepare for storage, refer to Operator’s Manual.
Unpack Generator
1. Set the carton on a rigid, flat surface.
2. Remove everything from carton except generator.
3. Open carton completely by cutting each corner from top to bottom.
4. Ensure you have all included items prior to assembly.
5. Leave generator on carton to install the wheels.
Attach Wheels and Support Leg
NOTICE Wheels and support leg must be attached prior to adding any
engine oil and fuel.
1. Tip generator so that engine end is up.
2. Slide a flat washer (A) over axle stud (B).
1
3. Slide a wheel (C) over axle stud (B).
1
NOTICE Be sure to install wheel with raised hub inboard.
4. Slide axle stud (B) through mounting bracket.
1
5. Insert retaining pin (D) through hole on axle stud.
1
6. Repeat steps 2 thru 5 to secure second wheel.
7. Line up holes in support leg (E) with holes in generator frame.
1
8. Attach support leg using four bolts (F) and four flange nuts (G).
Tighten with 10 mm and 13 mm wrenches.
1
9. Return generator to normal operating position (resting on wheels and
support leg).
Add Engine Oil and Fuel
NOTICE Be sure you have attached wheels and support leg prior to this
step.
NOTICE You MUST properly fill engine with oil before attempting to start
generator.
NOTICE DO NOT use unapproved gasoline such as E15 and E85. DO
NOT mix oil in gasoline or modify engine to run on alternate fuels.
1. Move generator outdoors to a flat, level surface.
2. Clean area around oil fill and remove yellow oil fill cap/dipstick ( ).
2
3. Using oil funnel (optional), slowly pour contents of both provided oil
bottles into oil fill opening to the Full mark (H) on dipstick.
3
4. Replace oil fill cap/dipstick and fully tighten.
5. Clean area around fuel fill cap ( ), remove cap.
4
6. Slowly add unleaded fuel to fuel tank. Be careful not to fill above
the red fuel level indicator (J). This allows adequate space for fuel
expansion as shown.
5
7. Replace fuel cap, and let any spilled fuel evaporate before starting
engine.
Items Included: Keys (model 030620 only) and Operator’s Manual (Not Shown)
© 2013 Briggs & Stratton Power Products Group, LLC. All rights reserved.
Every effort has been made to ensure that the information in this document is accurate and correct. However, we reserve the right to alter or otherwise improve the product and this document at any time without prior notice and without incurring obligation.
This generator is rated in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators) and PGMA (Portable Generator Manufacturers’ Association) standard PGMA G200 (Standard for Testing and Validating Performance of
Portable Generators).
Quick Setup Guide
Portable Generator
Have Questions?
Do not return to store. We can help.
Vist our web site BRIGGSandSTRATTON.COM
1
F
G
E
B
A
C
D
9
Q
10
R
80008111, Rev -
WARNING Damaged or overloaded electrical cords could overheat,
arc, and burn resulting in death or serious injury. ONLY use
cords rated for your loads. Follow all safeties on electrical
cords. Inspect cord sets before each use.
2
4
12
T
13
8
P
WARNING Failure to read and follow the operator’s
manual and all operating instructions could
result in death, serious injury, and/or property
damage.
WARNING Engine exhaust contains carbon
monoxide, a poisonous gas that could kill
you in minutes. You CANNOT smell it, see
it, or taste it. Operate ONLY outside far away
from windows, doors and vents. Install carbon monoxide
alarms. DO NOT run this product inside homes or garages,
even if using fans or opening doors and windows. Direct
exhaust AWAY from windows, doors, and vents.
WARNING Generator voltage could cause
electrical shock or burn resulting in death or
serious injury. DO NOT operate under wet
conditions.
WARNING Fuel and its vapors are extremely
flammable and explosive which could cause
burns, fire or explosion resulting in death or
serious injury. Turn generator engine OFF
and let it cool at least 2 minutes before removing fuel
cap. Let spilled fuel evaporate before starting engine.
Always allow space for fuel expansion.
WARNING Hot exhaust and reflective exhaust
gases could cause burns and fires resulting
in death or serious injury. Keep at least 1.5 m
(5 ft.) clearance from any combustibles or
structures, including overhead.
Items Needed: (Not Included)
• Carbon monoxide (CO) alarm(s) • Utility knife • 10 mm and 13 mm wrenches
• Unleaded fuel (minimum 87 octane)
5
J
7
E
X
H
A
U
S
T
(
C
O
)
Basement
Crawlspace
Garage
Attic
Entryway,
Porch
Only use OUTSIDE and
FAR AWAY from windows,
doors and vents.
Direct exhaust AWAY
from windows,
doors and vents.
DO NOT operate in any of the below locations
KEEP
FAR AWAY
Generator too
close to home and
exhaust directed
towards windows,
doors and vents.
CO Alarm
In Living Areas
E
X
H
A
U
S
T
(
C
O
)
6
N
M
L
K
3
H
11
S
12
  • Page 1 1

Simplicity 030618-00 Installation guide

Category
Power generators
Type
Installation guide
This manual is also suitable for

Simplicity 030618-00 is a portable generator that provides backup power during outages or recreational activities. It's powered by a Briggs & Stratton engine and generates up to 3,000 watts of continuous power and 3,500 surge watts. With a 4-gallon fuel tank, it can run up to 10 hours at 25% load. It features electric start with recoil backup, automatic voltage regulation (AVR) for stable power, and a low-oil shutdown to protect the engine. It also includes wheel and support leg kits for easy mobility and stability.

Ask a question and I''ll find the answer in the document