NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible
party who maintains the system.
MODEL S4
SUMP AND EFFLUENT PUMPS
INSTALLATION AND SERVICE MANUAL
Part # 23833A128 | © 2012 Pentair Pump Group, Inc. | 11/08/12
23833A128 11/08/12 2
SAFETY PRECAUTIONS
All Myers sump pumps are grounded to prevent
electrical shock. POWER CORD MUST BE
PLUGGED INTO GROUNDED TYPE RECEPTACLE.
A separate circuit breaker or fuse block should be
used for the pump and 15 amp circuit breaker or
fuse should be used.
Receptacle must be installed at least 4 feet
above floor level to prevent tampering by small
children and to be out of possible flooding range.
Be careful with power cord to prevent cutting or
pinching.
DO NOT USE AN EXTENSION CORD WITH SUMP
PUMP. DO NOT CUT OFF GROUND PIN OR USE
AN ADAPTER FITTING. DO NOT WORK ON PUMP
OR SWITCH UNTIL POWER CORD OR CORDS
ARE UNPLUGGED.
Sump basin must be vented in accordance with
local plumbing codes. These pumps are not
designed for and cannot be installed in locations
classified as hazardous in accordance with the
National Electric Code ANSI/NFPA 70.
CALIFORNIA PROPOSITION 65 WARNING:
This product and related
accessories contain chemicals known to the
State of California to cause cancer, birth
defects or other reproductive harm.
PUMP DESCRIPTION
The S4 is offered for either 115 volt or 230 volt–single
phase–60 hertz.
The S4 sump pumps can be used to pump any
basement drainage water. NOT TO BE USED FOR
SEWAGE WATER EXCEPT TO PUMP SEPTIC TANK
EFFLUENT.
The S4 can be used to pump septic tank effluent but
must be installed in separate tank or compartment at
the discharge side of the septic tank. NEVER INSTALL
PUMP DIRECTLY WHERE SLUDGE COLLECTS.
For septic tank pumping the automatic pumps should
be used with a junction box. The manual pumps
should be used with a junction box and an MLC level
control. When a junction box is used, cut off the plugs
on the pump cord and the MLC switch cord and strip
ends. The MLC switch must be connected in series
with one line. This provides a completely sealed
system for power cord and pump cord with no open
receptacles or taped connections that can cause
electrical failure.
The S4 sump pumps can be installed in any open
or closed type sump basin with a diameter of 12 to
18 inches. A polyethylene, fiberglass or concrete tile
basin may be used. If concrete tile is used, cement
should be poured in the bottom to give a smooth
surface free of stones.
PIPING
Pumps can be installed with ABS, PVC, polyethylene,
galvanized or copper pipe. Proper adapters are
required to connect plastic pipe to pump.
The S4 discharge is threaded for 1-1/2 inch pipe.
NOTE: DO NOT USE THREAD COMPOUND OR
OVERTIGHTEN DISCHARGE PIPE INTO PUMP
PLASTIC DISCHARGE FITTING.
A CHECK VALVE MUST BE USED IN THE
DISCHARGE LINE FOR ALL PUMPS. A shutoff
valve should be used with all S4 sump pumps.
Always install check valve with arrow on body in
the direction of flow.
AIR LOCKING
A sump pump is said to be air locked if water traps
air in the pump and the air cannot get out, thus
preventing pump from operating.
ALL MYERS SUMP PUMPS HAVE A SMALL AIR
VENT HOLE IN THE IMPELLER CHAMBER TO
LET OUT TRAPPED AIR. IF THIS HOLE BECOMES
PLUGGED, PUMP MAY AIR LOCK. THIS USUALLY
HAPPENS ON PUMPS THAT ARE USED MAINLY IN
THE WET SEASONS. IN SUMMER MONTHS, THE
PUMP MAY BE TURNED OFF AS SUMP WATER
DRIES UP. WHEN PUMP IS TURNED ON AGAIN AND
WATER COMES UP IN SUMP, THE AIR WILL TRAP IN
PUMP IF NOT VENTED.
AS A SECONDARY PRECAUTION IN INSTALLATIONS
OF THIS TYPE – 1/8" HOLE SHOULD BE DRILLED
IN THE DISCHARGE PIPE BELOW THE CHECK
VALVE. THE CHECK VALVE SHOULD BE 12 TO 18
INCHES ABOVE PUMP DISCHARGE. DO NOT PUT
CHECK VALVE DIRECTLY INTO PUMP DISCHARGE
OPENING.
STARTING PUMP – S4A (AUTOMATIC)
1. These pumps have an integral mechanical ball float
switch as shown on installation drawing.
2. The S4A1C is for 115 volts and S4A2C is for
230 volts. Plug cord into the proper voltage
GROUNDED RECEPTACLE. The 115 volt plug will
not plug into a 230 volt receptacle and vice versa.
3. Run water into sump until pump starts.
4. Allow pump to operate through several on-off
cycles to be sure operation is satisfactory.
23833A128 11/08/12
3
5. If shutoff valve is used in discharge line, be sure
valve is open.
NOTE: TETHER LENGTH OF SWITCH CORD MUST
BE A MINIMUM OF 3-5/8".
STARTING PUMP – S4M (MANUAL) USING
MFS SWITCH WITH SERIES PLUG
1. Install unit as shown on the installation drawing.
Secure ball float to discharge pipe with minimum
3-1/2 inches between float and cable tie.
2. The S4M1C is for 115 volts and the S4M2C is for
230 volts. Plug MFS switch cord series plug into
proper voltage GROUNDED RECEPTACLE.
3. Plug pump cord plug into back of switch cord
series plug.
4. Run water into sump until pump starts. The level
should be 12 to 13 inches above sump bottom.
5. Be sure gate valve in discharge line is open.
NOTE: TETHER LENGTH OF SWITCH CORD MUST
BE A MINIMUM OF 3-5/8".
USING THE S4M FOR
MANUAL OPERATION
The pump cord for these units can be plugged directly
into proper GROUNDED RECEPTACLE for continuous
pump operation.
CAUTION: THIS TYPE OF OPERATION SHOULD BE
USED ONLY FOR EMERGENCY USE OR WHERE
A LARGE VOLUME OF WATER IS TO BE PUMPED,
SUCH AS A FLOODED BASEMENT.
PUMP MUST NOT RUN CONTINUOUSLY OUT OF
WATER. DO NOT USE WITH EXTENSION CORD.
AUTOMATIC/MANUAL MODEL
The model S4 sump pumps can be changed from
one style, automatic or manual, to the other by only
interchanging the plug ends of the float control with
the manual plug. The ball floats must be tethered with
a cable clamp, as shown. DO NOT REMOVE THE
MOTOR CAP.
HOW MECHANICAL SWITCH
FLOAT OPERATES
This level control uses a mechanical switch sealed in a
polypropylene float cylinder. The switch is not position
sensitive; that is, it will operate regardless of position.
When level rises in the sump, the cylinder floats up
with the level. When the cylinder position is at an
angle of about 45°, the steel ball rolls over a detent
and activates the switch. This starts the pump motor.
As the sump level draws down, the cylinder floats
down and when it is again at an angle of about 45°,
the steel ball drops away, deactivating the switch and
the motor stops.
BE SURE CYLINDER FLOATS FREELY IN SUMP
BASIN WITHOUT TOUCHING THE BASIN WALLS.
ADJUST PUMP POSITION IN SUMP IF NECESSARY.
PUMP MOTOR
NEVER REMOVE MOTOR HOUSING OR UNSCREW
PUMP IMPELLER. Warranty on pump is void if motor
housing, impeller or seal have been removed. Any
repair on motor must be done by an authorized Myers
service center.
CLEANING FLOAT
If pump becomes inoperative because of
accumulation of trash on the float, remove pump from
sump and clean float.
1. Wipe all water and dirt from pump and float.
2. Be sure float operates freely after cleaning.
CLEANING IMPELLER AND VOLUTE CASE
1. Remove the 5 screws that hold the lower plastic
base to the plastic volute case.
2. Use screwdriver to separate the plastic parts. Use
care not to gouge a groove in the plastic. Pry in
several spots to loosen.
3. Remove loosened part and clean impeller and
volute passage.
4. Be sure impeller turns freely after cleaning.
5. Clean out holes in plastic pump base and wash
thoroughly before replacing.
6. DO NOT UNSCREW IMPELLER.
23833A128 11/08/12 4
Pump does not run or hum.
See A, B, C, D, E or F.
Pump runs but does not deliver
water.
See G, H, I, J K or L.
Pump runs and pumps out
sump but does not stop.
See M.
Pump runs but delivers only
small amount of water.
See I, J, K, L or N.
Fuse blows or circuit breaker
trips when pump starts.
See K, L, N, O or P.
Motor runs for short time then
stops. Then after short period
starts again. Indicates tripping
overload.
See K, L, N or P.
A. Line circuit breaker may be off,
or fuse, if used, may be blown
or loose.
B. Water level in sump may be too
low. Run in more water. Turn-
on level is 12 to 13" above
sump bottom for S4.
C. Pump cord plug may not be
making contact in receptacle.
D. If pump is using the series
cord plug, the two plugs may
not be plugged tight together.
E. Float may be stuck. Be sure
float operates freely in basin.
F. If all symptoms check OK,
motor winding may be open;
take to service center for
check.
G. Check valve may be installed
backward. Arrow on valve
points in direction of flow.
H. Discharge shutoff valve, if
used, may be closed.
I. Pump may be air locked. Start
and stop several times by
plugging and unplugging cord.
Check vent hole for plugging.
J. Pump head may be too high.
Pump cannot deliver water
over 24 ft. vertical. Horizontal
distance does not affect
pumping, except loss due to
friction.
K. Inlet holes in pump base may
be clogged. Remove pump
and clean out openings.
L. Impeller or volute openings
may be plugged or partially
plugged. Remove pump
and clean per maintenance
instructions.
M. Float is stuck in up position.
Be sure float operates freely in
basin.
N. Pump impeller may be partially
clogged with tar or paint,
causing motor to run slow,
resulting in motor overload.
O. Fuse size or circuit breaker is
too small. Must be 15 amps.
P. Defective motor stator; return
to an authorized Myers service
center.
TROUBLESHOOTING
SYMPTOMS SOLUTIONS
23833A128 11/08/12
5
REPAIR PARTS
Ref. No. Description Qty.
Part Numbers
S4A1C S4A2C S4M1C S4M2C
1 Cord, Electric, with Plug 1 21628B044 21628B043 21628B044 21628B043
2 Control, Level, with Plug Connector 1 21813B128 21813B128
3 Plug, 1/8" Pipe 1 05022A068 05022A068 05022A068 05022A068
4Wire with Terminals 1 09859A800 09859A800 09859A800 09859A800
5 Screw, Machine 1/4-20 x 7/8 Lg. 6 18475A003 18475A003 18475A003 18475A003
6 Cap, Motor (Not Stamped) 1 24431C000 24431C000 24431C000 24431C000
7 Ring, O, 5-1/2 x 5-1/4 I.D. x 1/8 1 05876A146 05876A146 05876A146 05876A146
8 Oil, Transformer (1 gal. in can) .375 gal. 11009A008 11009A008 11009A008 11009A008
9 Housing & Stator Assembly Includes: 1 24446C010 24446C011 24446C010 24446C011
Housing 1 24446C001 24446C001 24446C001 24446C001
Stator 1 21599B020 21599B021 21599B020 21599B021
Washer, SST, 1 x 33/64 x 1/32 2 05030A173 05030A173 05030A173 05030A173
Washer, Teflon®, 1 x 33/64 x 1/16 1 05030A163 05030A163 05030A163 05030A163
Rotor with Shaft 1 22821A001 22821A001 22821A001 22821A001
Plate, Bearing 1 24661B000 24661B000 24661B000 24661B000
10 Screw, S-T, #10 x 1/2 Lg. 2 09822A006 09822A006
11 Clam, Cable 1 17190A008 17190A008
12 Seal, 1/2" Shaft 1 21607A010 21607A010 21607A010 21607A010
13 Screw, Mach., Flat HD., #10-24 x 5/8" 4 07597A030 07597A030 07597A030 07597A030
14 Impeller 1 21542B000 21542B000 21542B000 21542B000
15 Sealant, Loctite® Grade 222 1 14550A005 14550A005 14550A005 14550A005
16 Case, Volute 1 24633D000 24633D000 24633D000 24633D000
17 Base 1 21543D000 21543D000 21543D000 21543D000
18 Clip 4 21609A000 21609A000 21609A000 21609A000
19 Screw, S-T, #10 x 1-3/4" 5 09822A040 09822A040 09822A040 09822A040
20 Plate 1 21544B000 21544B000 21544B000 21544B000
21 Plug, Manual 1 24448A000 24448A000
22 Washer, Plastic 1 05030A213 05030A213
23 Plug, Connector 1 24449A000 24449A000
Item Cord Length Volt Part Number
Control Switch
10' 115 218139130
20' 115 218139131
10' 230 218139132
20' 230 218139133
10' 115 216289041
20' 115 216289044
10' 230 216289042
20' 230 216289043
S4M1C & S4M2C
(MANUAL)
S4A1C & S4A2C
(AUTOMATIC)
23833A128 11/08/12 6
S4A TYPICAL INSTALLATION
23833A128 11/08/12
7
S4M TYPICAL INSTALLATION
1101 MYERS PARKWAY 490 PINEBUSH ROAD, UNIT #4
ASHLAND, OHIO, USA 44805 CAMBRIDGE, ONTARIO, CANADA N1T 0A5
419-289-1144 800-363-PUMP
WWW.FEMYERS.COM
Warranty Rev. 12/13
STANDARD LIMITED WARRANTY
Pentair Myers® warrants its products against defects in material and workmanship for a period of 12 months from the
date of shipment from Pentair Myers or 18 months from the manufacturing date, whichever occurs first – provided
that such products are used in compliance with the requirements of the Pentair Myers catalog and technical manuals
for use in pumping raw sewage, municipal wastewater or similar, abrasive-free, noncorrosive liquids.
During the warranty period and subject to the conditions set forth, Pentair Myers, at its discretion, will repair or
replace to the original user, the parts that prove defective in materials and workmanship. Pentair Myers reserves the
right to change or improve its products or any portions thereof without being obligated to provide such a change or
improvement for prior sold and/or shipped units.
Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of start-
up through the Pentair Myers website: http://forms.pentairliterature.com/startupform/startupform.asp?type=m.
Warranty is effective only if Pentair Myers authorized control panels are used. All seal fail and heat sensing devices
must be hooked up, functional and monitored or this warranty will be void. Pentair Myers will cover only the lower
seal and labor thereof for all dual seal pumps. Under no circumstance will Pentair Myers be responsible for the cost
of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the
factory or an authorized Pentair Myers service facility.
This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or
maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident
or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that
are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is
moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and
manufactured; (g) to any unit that has been repaired or altered by anyone other than Pentair Myers or an authorized
Pentair Myers service provider; (h) to any unit that has been repaired using non factory specified/OEM parts.
Warranty Exclusions: PENTAIR MYERS MAKES NO EXPRESS OR IMPLIED WARRANTIES THAT EXTEND BEYOND
THE DESCRIPTION ON THE FACE HEREOF. PENTAIR MYERS SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.
Liability Limitation: IN NO EVENT SHALL PENTAIR MYERS BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL,
INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER TO ANY PENTAIR MYERS
PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM IMPROPER
INSTALLATION. PENTAIR MYERS DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS WARRANTY, FOR
IMPROPER INSTALLATION. PENTAIR MYERS RECOMMENDS INSTALLATION BY PROFESSIONALS.
Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or
consequential damages and therefore such limitations may not apply to you. No warranties or representations at any
time made by any representatives of Pentair Myers shall vary or expand the provision hereof.
/