Commax DRC-UC/RF1 Series, DRC-2/3/4/5/6/7UC, DRC-3UC/RF1, DRC-6UC/RF1 User manual

  • Hello! I am an AI chatbot trained to assist you with the Commax DRC-UC/RF1 Series User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
DOOR STATION DRC-nUC/RF1
User Manual
Thank you for purchasing COMMAX products.
Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow
instructions to use a product exactly.
The company is not responsible for any safety accidents caused by abnormal operation of the product.
2
Contents
1.Overview ·································································································· 3
2. How to use ····························································································· 3
3. Method of using RF card key ······································································· 4
4. Wiring····································································································· 6
5. Installation ··································································································7
6. Part List ····································································································7
7. Specication ·······························································································8
8. RF-ID Model ·······························································································9
3
1. Overview
Notice
1.
DRC-nUC/RF1 is a Master unit which has functions to call or communicate with a house unit.
2.
“ n “ stands for the No. of house that DRC-nUC/RF1 can call.
DRC-nUC/RF1 : 1UC / 2UC / 3UC / 4UC / 5UC / 6UC are available.
2. How to use
FEATURES AND CAUTIONS
1.
The power supply of this product is DC12V
( Including LED lamp of name label etc.)
2.
If user answer the household phone when you call from the door
camera(entrance), you can talk.
3.
Please note that it makes call other household phone you don’t
want if you press other call button mistakenly.
4.
Please note that 3-way communication is possible when another
user turn on the monitor when you are talking with door camera
user on household video phone.
5.
If you want to open the door using a RF card key, please tag it to
this( ) point.
3.
Method of using RF card key
4
* Type of button
Button 1 : Master card registration button (For registration purpose) -> rear REGISTRATION button
Button 2 : Master Card registration button (For card deletion purpose) -> rear DELETE button
Button 3 : Deletion button / Front (Outer) Option button
1. How to register Master Card
1) Master card for Registration.
(1) LED slowly flickers with beep sound on pressing button 1.
(2) Tag the master card for registration on LED flickering.
(3) If registered normally, LED flickering and beep sound stops.
2) Master card for deletion
(1) LED flickers fast with beep bound on pressing button 2.
(2) Tag the master card for deletion on LED flickering.
(3) If registered normally, LED flickering and beep sound stops.
Remark
1.
Master card can be registered both registration/deletion purpose (1card/each purpose only)
2.
In case of new mater card registration, the previous master card information will be deleted
and new card information will be registered.
- Caution : You can use only mini type RF card by COMMAX
5
2. Door release card registration/deletion
1) Card registration
(1) On tagging the master card for registration, LED slowly flickers with beep sound.
(Entering registration mode).
(2) Beep sound comes out when door release card is tagged.
(3) In case more than 1 cards have to be registered, repeat above (2) procedure.
(4) Press button 3. when the registration finish.
2) Individual Card deletion
(1) LED flickers fast on tagging master card for deletion. (Entering Pre-Deletion mode).
(2) Press button 3. Then beep sound comes out. (Entering Individual deletion mode)
(3) After tagging the card which need to be deleted, LED flickering and beep sound stops.
(4) Repeat (1)~(3) procedure to delete other cards.
3) All cards deletion
(1) On tagging the master card for deletion, LED flickers fast
(Entering Pre-Deletion mode).
(2) Press button 3.(5seconds). Then, LED flickers faster with beep sound.
(Entering All cards deletion mode)
(3) Tag master card for deletion again. Then, LED gets turned off and all cards deletion will be processed.
After all cards information deleted, LED gets turned on with beep sound.
Remark
1) Maximum 2,046 cards can be registered.
2) In case of exceeding card registeration memory, beep sound comes out for 1.5 second.
3) Press button 3. to escape from registration/deletion mode while processing registration/deletion process.
4) Do not turn off the device until all cards deletion process is completed.
4.
Wiring
6
(1) DRC-1UC/RF1 (2) DRC-2UC/RF1
(3) DRC-3UC/RF1
5
(4) DRC-4UC/RF1
(5) DRC-5UC/RF1
(6) DRC-6UC/RF1
7
5.
Installation
Please refer to the below images regarding
the installation position of the product
6.
Part List
8
7.
Specification
Model
DRC-nUC/RF1
DC12V,1A
Wiring 4 Wires(Polarity)
Communication Hands-free(Duplex)
Min. Lux.
0.1Lux(UP TO 300mm From the Camera)
Light White LED(3pie) 2EA Built-In
Camera Angle
HORIZONTAL : 82°, VERTICAL : 66.5°
Angle
UP 13°, DOWN 13°
Camera Module C-MOS
Temperature
-20(tested up to -40) ~ +50, 95%
Dimension(mm)
DRC-4UC/RF1, 5UC/RF1, 6UC/RF1
DRC-1UC/RF1, 2UC/RF1, 3UC/RF1
130(W) x 250(H) x 50(D)
Diameter Φ 0.5
Dimension(mm)
Power source
142(W) x 315(H) x 50(D)
Distance
30m
Φ 0.65
50m
9
8. RF-ID Model
DRC-nUC/RF1 (‘n’ is the number of households what can be called)
13.56MHz
Antenna power range Under 47.5mV/m within 10 meter radius
Power DC 5V
Emission Type
A1D
Number of Channel 1 Channel
Modulation method
ASK
Communication method
Simplex Operation Method
Temperature
-20(tested up to -40) ~ +50, 95%
Frequency
Model Name
Printed In Korea / 2016 .10.105