12 13
- As the connecting method varies with the instruments, refer to the manual
supplied with the instrument.
- If necessary, you can connect the monitor to the REMOTE jack on the back of
your camera.
- Only connect the cable when the power is turned off.
- Set the 75Ω / Hi-Z selection switch as shown below if you have an intermediate
device.
VIDEO
1) Connection to Monitor
2) Connection to Power
Connect the adaptor to the power input connector
as shown in the figure right. The Standard voltage
for camera operation : DC 12V ± 10%, AC 24V±10%.
Power Input
Note
If you wish to use RS-485 connection, verify the proper polarity.
Connection
VIDEO
Dome Camera
3) Connection to RS-485
Using an RS485 connection you can control the OSD menu via the DVR
or system controller.
(1) Control via a PC
Using a RS-485 converter, It connects to RS-485 control cable outside camera
and serial cable
EX) SERIAL PORT OF THE PC(COM1) SERIAL CABLE RS-485
CONVERTER RS-485 CONTROL CABLE
(2) When controlling via a DVR or system controller connect the RS-485.
It connects the RS-485 control cable in the connection terminal of 485 control
boards which are connected with the DVR or System Controller.
→→
→
485 Control Board Connection Port RS-485 Control Port
(+) CONNECTION TERMINAL Brown (TRX+)
(- ) CONNECTION TERMINAL Blue (TRX-)
Item
Initial value
Camera ID
1
BAUD RATE
9600
UART MODE
8-NONE-1
RET PKT
ENABLE
ç RS-485 Communication parameters establishment initial value
Protocol : SAMSUNG
Baud Rate : 9600bps
Address : 1-255
When using a control system to operate the camera, please use the protocol:
SAMSUNG, PELCO-P or PELCO-D .
When use the RS485 control cable isolate the Drain wire.
-
-
Connection
NOTE
4) Connection to Alarm
Please see above RS485 connection picture. Normal Alarm output signal open,
and when motion detection operate, alarm output signal low to GND.
Dome Camera