COOKER HOOD
1 GENERAL
The model you have selected is a decorative cooker hood to be mounted on the wall.
A WALL MOUNTED HOOD is fixed to a straight wall.
It is a SUCTION hood which can also be used as a FILTERING hood.
A SUCTION HOOD extracts air, fumes and vapours from the inside environment and then expels them
outside. It is not necessary to use carbon filters for purifying.
A FILTERING HOOD extracts air, fumes and vapours from the inside environment, purifies them by
means of carbon filters and then emits the purified air into the same environment. In this case, the use
of carbon filters is absolutely necessary (SEE FIG. 1).
Carbon filters are available separately and can be purchased as optional accessories (SEE OPTIONAL
ACCESSORIES).
Each hood is pre-assembled at the factory.
The user must arrange for the correct mounting of the chimney, the carbon filters if required and the
fixing of the hood to the wall. Connection of the hood to the domestic electric supply must be carried out
by qualified personnel who use standard tools, methods and components.
Indications on how to proceed are given below.
2 AFTER PACKAGING HAS BEEN OPENED . . .
. . . you will find the following material and documentation:
• the hood and the height adjustable chimney;
• this instruction manual; a technical drawing with the dimensions and position of the support and
safety holes and the guarantee;
• a plastic bag containing: the corner bracket for fixing the extensible part of the chimney to the
ceiling; large screws with washers and pressure plugs for fixing the bracket; small screws for fixing
the chimney to the ceiling and to the hood;
• 2 sheet metal hooks, complete with: 2 screws with pressure plugs to fix the hood to the wall; 2
screws for height adjustment; 2 screws with corresponding pressure plugs and washers for safety
fitting to the wall.
3 BEFORE MOUNTING
Before mounting you should be aware of:
3.1) the power rating of the cooker:
- if it is below or equal to 7 kw (kilowatt), the hood should be mounted so that the minimum
distance between it and the top of the cooker is not less than 65 cms;
- if it is above 7 kw (kilowatt), the manufacturer recommends that the distance be increased
by 2,5 cms for each extra KW delivered by the cooker top.
DISTANCE in cms = 65 + 2,5 x (POWER in KW - 7)].
WARNING! If the user decides to install the hood at distances
below 65 cms, the manufacturer declines any responsibility for eventual damages
caused by the hood due to strong heat or damages to property or persons etc.
caused directly or indirectly by any type of malfunctioning breakdown or possible
fire (SEE FIG. 2).
3.2) arrange for a socket outlet or standard connection to the electric mains at a suitable distance;
if the use of a plug is required, and the feed cable is not provided with one, have a plug
installed as per standard procedures;
3.3) if the hood is used as a suction hood, it is necessary to make a hole towards the outside
(i.e. in the open air) for the scavenging of the fumes.
WARNING! It is absolutely forbidden for the user to connect the air
discharge of the hood, when used as a suction hood, to boiler chimneys, gas, fume
or vapour scavenging chimneys or any other duct, even only ventilation ducts,
which have been used or will be used for other devices. Moreover, it is not
permitted to connect the scavenging pipe with fumes which are issued in other
adjacent rooms or wellholes, particularly if they contain fire-fighting devices.
Any user who does not adhere to these instructions is risking his own life and the lives of
others. In this case, the manufacturer declines any responsibility (SEE FIG. 3).
If the previous conditions have been checked, the hole to be made on the wall and also the
scavenging pipe must be of the same diameter as the hood outlet duct.
3.4) If the hood is used as a suction hood, it is necessary for qualified personnel to make a hole
for ventilation on the outside wall.
If the cooker is gas, it is not advisable to use the hood at the same time as fireplaces,
furnaces, gas or other fuel stoves, or water heaters which burn up oxygen from the
environment in order to function, and in any case depression in the cooker area must be
below 4 Pa (0.04 mbar) and the room must be sufficiently aired.
If in doubt, national and international standards precisely indicate the rules for the state of art
installation of gas systems and for environment air change, to avoid the possibility of
incomplete combustions with the risk of poisonous fumes being emitted (SEE FIG. 4).
3.5) If the hood is to be used as a filtering hood, it is necesary to purchase the pair of carbon
filters (SEE ACCESSORIES). The mounting instructions will be given at paragraph 4.3.