ADTRAN 600E, TSU 600, TSU 600e User manual

  • Hello! I am an AI chatbot trained to assist you with the ADTRAN 600E User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
TSU 600 & 600e Systems
Preconfigured Plug-and-Play T1/FT1 Multiplexers for Voice or Data
Product Features
Pre-configured T1 multi-
plexers with factory
installed modules
Options for Nx data and
FXS, FXO and E&M voice
From 12 to 24 ports
per chassis
ADTRAN’s industry-
leading TSU 600 and
TSU 600e technologies
Embedded SNMP
management
TR-08 Mode 1 compliant
(unconcentrated)
Front panel, backlit LCD
Extensive network testing
and troubleshooting
T-Watch PRO
and Telnet
support for local and
remote units
Industry-leading North
American five-year
warranty
Preconfigured TSU 600
and TSU 600e
systems offer the functionality of ADTRAN’s
fully featured T1 multiplexers in pre-installed
and pre-configured equipment packages.
These systems utilize the TSU 600 or TSU 600e
chassis packed with multiple expansion cards
for high volume voice and data applications.
Available packages represent the most
frequently requested configurations of the
TSU 600 and TSU 600e multiplexers, with
expansion cards to support 12 data ports,
or 24 FXO, FXS or E&M voice ports.
The TSU 600 and TSU 600e chassis have
six expansion slots that accommodate various
ADTRAN
®
expansion cards to support user-
specific applications, including analog voice,
digital voice, DDS, Frame Relay, dial backup,
high-speed data and ISDN. Both units include
embedded SNMP functionality. The TSU 600e
adds an integrated 10Base-T interface to the
TSU 600 feature set, along with optional
support for internal, dual redundant power
supplies. Each hot-swappable power supply is
capable of supporting a fully loaded TSU 600e.
The flexibility of the TSU 600/600e multi-
plexer provides a clear migration path for
growing networks. Each chassis supports up
to 24 DTE interfaces. The user may combine
plug-in and plug-on modules in various
combinations. Single-port and dual-port
data modules support access to Frame Relay,
DDS or Basic Rate ISDN over T1 facilities.
Voice modules allow access to analog voice
circuits or a PBX. The TSU 600/600e supports
mixed-mode networks incorporating voice,
data and video.
The TSU 600/600e equipment packages
are factory-configured before shipping. For
ongoing configuration and management,
the TSU 600/600e and installed expansion
modules are fully SNMP compatible. The
TSU 600 communicates management infor-
mation via a SLIP (EIA-232) port; while the
TSU 600e offers the convenience of a 10Base-T
port for direct connection to the LAN. Both
units include Telnet functionality and a front
panel LCD for anual configuration.
ADTRAN offers two network management
software programs to support configuration
and management of the TSU 600/600e Series.
T- Wa tch PRO
is a Windows‚ 95 or NT‚
compatible program that facilitates easy
configuration and monitoring of all ADTRAN
host and remote devices. For HP OpenView
networks, ADTRAN offers ADVISION
, an
SNMP-based graphical user interface that
integrates seamlessly into a UNIX-based
enterprise-wide network management system.
Specifications subject to change without notice. ADVISION, T-Watch PRO, TSU 600
and TSU 600e are trademarks of ADTRAN, Inc. ADTRAN is a registered trademark
of ADTRAN, Inc. All other registered trademarks and trademarks mentioned in this
publication are the property of their respective owners.
Product Specifications
TSU 600 DP12 NX
TSU 600 multiplexer with six Nx56/64 V.35 Modules
and six Nx56/64 Plug-On Modules for a total of 12
data ports. Includes SNMP functionality.
TSU 600e VP24 FXS
TSU 600e multiplexer with six Quad FXS Plus
Modules for a total of 24 voice ports. Includes
SNMP functionality. TR-08 compatible.
TSU 600 VP24 FXS
TSU 600 multiplexer with six Quad FXS Plus
Modules for a total of 24 voice ports. Includes
SNMP functionality. TR-08 compatible.
TSU 600 DC VP24 FXS
DC powered version of the TSU 600 multiplexer with
six Quad FXS Plus Modules for a total of 24 voice
ports. Includes SNMP functionality. TR-08 compatible.
TSU 600e VP24 FXO
TSU 600e multiplexer with six Dual 2FXO Modules
and six Dual 2FXO Plug-Ons for a total of 24 voice
ports. Includes SNMP functionality.
TSU 600 VP24 FXO
TSU 600 multiplexer with six Dual 2FXO Modules and
six Dual 2FXO Plug-Ons for a total of 24 voice ports.
Includes SNMP functionality.
TSU 600 VP24 E&M
TSU 600 multiplexer with six Dual E&M/TO Modules
and six Dual E&M/TO Plug-Ons for a total of 24 E&M
ports. 2713 Hz loopback detection.
Includes SNMP functionality.
For more detailed specifications on the TSU 600 or 600e
multiplexers or the voice and data expansion cards
included in the Preconfigured TSU 600 Systems, please
call 800 9ADTRAN and request a copy of the TSU 600 &
600e data sheet (document number 61202076L1-8B), the
Nx56/64 Solutions data sheet (document number
61202054L1-8B), or the Analog Voice Modules data
sheet (document number 61200080L1#HS-8A).
TSU 600 & 600e Systems
Preconfigured Plug-and-Play T1/FT1 Multiplexers for Voice or Data
Ordering Information
Equipment Part #
TSU 600 1202076L2
TSU 600e 1202076L1
TSU 600 DP12 Nx 4200076L2
TSU 600e VP24 FXS 4202076L1
TSU 600 VP24 FXS 4200076L1
TSU 600 DC VP24 FXS 4200076L1#DC
TSU 600e VP24 FXO 4202076L3
TSU 600 VP24 FXO 4200076L3
TSU 600 VP24 E&M 4200076L5
MODULE 1
MODULE 2
MODULE 3
MODULE 4
MODULE 5
MODULE 6
CONTROL
/CHAIN
IN OUT
IN OUT MON NETWORK
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
O
I
5A/250V
CAUTION:
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
90-120 VAC
50/60 HZ.
Nx56/64 PORT X.1 Nx56/64 PORT X.2
V.35
D
J
N
T
X
BB
FF
LL
B
F
L
R
V
Z
DD
JJ
NN
C
H
M
S
W
AA
EE
KK
A
E
K
P
U
Y
CC
HH
MM
D
J
N
T
X
BB
FF
LL
B
F
L
R
V
Z
DD
JJ
NN
C
H
M
S
W
AA
EE
KK
A
E
K
P
U
Y
CC
HH
MM
Nx56/64 PORT X.1 Nx56/64 PORT X.2
V.35
D
J
N
T
X
BB
FF
LL
B
F
L
R
V
Z
DD
JJ
NN
C
H
M
S
W
AA
EE
KK
A
E
K
P
U
Y
CC
HH
MM
D
J
N
T
X
BB
FF
LL
B
F
L
R
V
Z
DD
JJ
NN
C
H
M
S
W
AA
EE
KK
A
E
K
P
U
Y
CC
HH
MM
Nx56/64 PORT X.1 Nx56/64 PORT X.2
V.35
D
J
N
T
X
BB
FF
LL
B
F
L
R
V
Z
DD
JJ
NN
C
H
M
S
W
AA
EE
KK
A
E
K
P
U
Y
CC
HH
MM
D
J
N
T
X
BB
FF
LL
B
F
L
R
V
Z
DD
JJ
NN
C
H
M
S
W
AA
EE
KK
A
E
K
P
U
Y
CC
HH
MM
Nx56/64 PORT X.1 Nx56/64 PORT X.2
V.35
D
J
N
T
X
BB
FF
LL
B
F
L
R
V
Z
DD
JJ
NN
C
H
M
S
W
AA
EE
KK
A
E
K
P
U
Y
CC
HH
MM
D
J
N
T
X
BB
FF
LL
B
F
L
R
V
Z
DD
JJ
NN
C
H
M
S
W
AA
EE
KK
A
E
K
P
U
Y
CC
HH
MM
Nx56/64 PORT X.1 Nx56/64 PORT X.2
V.35
D
J
N
T
X
BB
FF
LL
B
F
L
R
V
Z
DD
JJ
NN
C
H
M
S
W
AA
EE
KK
A
E
K
P
U
Y
CC
HH
MM
D
J
N
T
X
BB
FF
LL
B
F
L
R
V
Z
DD
JJ
NN
C
H
M
S
W
AA
EE
KK
A
E
K
P
U
Y
CC
HH
MM
Nx56/64 PORT X.1 Nx56/64 PORT X.2
V.35
D
J
N
T
X
BB
FF
LL
B
F
L
R
V
Z
DD
JJ
NN
C
H
M
S
W
AA
EE
KK
A
E
K
P
U
Y
CC
HH
MM
D
J
N
T
X
BB
FF
LL
B
F
L
R
V
Z
DD
JJ
NN
C
H
M
S
W
AA
EE
KK
A
E
K
P
U
Y
CC
HH
MM
CAUTION-RISK OF
ELECTRIC SHOCK
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
TELECOMMUNICATION WIRING.
ADTRAN, Inc.
Attn: Enterprise Networks
901 Explorer Boulevard
Huntsville, AL 35806
P. O. Box 140000
Huntsville, AL 35814-4000
256 963-8000 voice
256 963-8699 fax
256 963-8200 fax back
General Information
800 9ADTRAN
www.adtran.com
Pre-Sales
Technical Support
800 615-1176 toll-free
www.adtran.com/support
Where to Buy
877 280-8416 toll-free
www.adtran.com/where2buy
Post-Sales
Technical Support
888 423-8726
www.adtran.com/support
ACES Installation &
Maintenance Service
888 874-ACES
www.adtran.com/support
International Inquiries
256 963 8000 voice
256 963-6300 fax
www.adtran.com/international
For the regional office
nearest you, visit:
www.adtran.com/regional
Printed in the U.S.A.
64200076LX-8D February 2004
Copyright © 2004 ADTRAN, Inc.
All rights reserved.
ADTRAN is a TL 9000 3.0
certified supplier.
ADTRAN is a ISO 9001:2000
certified supplier.
MODULE 1
MODULE 2
MODULE 3
MODULE 4
MODULE 5
MODULE 6
CONTROL
/CHAIN
IN OUT
IN OUT MON NETWORK
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
O
I
5A/250V
CAUTION:
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
90-120 VAC
50/60 HZ.
CAUTION-RISK OF
ELECTRIC SHOCK
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
TELECOMMUNICATION WIRING.
DUAL E&M PORT X.2
PORT X.3 PORT X.4
DUAL
E&M
PORT X.1 PORT X.2
DUAL E&M PORT X.2
PORT X.3 PORT X.4
DUAL
E&M
PORT X.1 PORT X.2
DUAL E&M PORT X.2
PORT X.3 PORT X.4
DUAL
E&M
PORT X.1 PORT X.2
DUAL E&M PORT X.2
PORT X.3 PORT X.4
DUAL
E&M
PORT X.1 PORT X.2
DUAL E&M PORT X.2
PORT X.3 PORT X.4
DUAL
E&M
PORT X.1 PORT X.2
DUAL E&M PORT X.2
PORT X.3 PORT X.4
DUAL
E&M
PORT X.1 PORT X.2
MODULE 1
MODULE 2
MODULE 3
MODULE 4
MODULE 5
MODULE 6
CONTROL
/CHAIN
IN OUT
IN OUT MON NETWORK
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
O
I
5A/250V
CAUTION:
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
90-120 VAC
50/60 HZ.
CAUTION-RISK OF
ELECTRIC SHOCK
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
TELECOMMUNICATION WIRING.
MODULE 1
MODULE 2
MODULE 3
MODULE 4
MODULE 5
MODULE 6
CONTROL
/CHAIN
IN OUT
IN OUT MON NETWORK
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
O
I
5A/250V
CAUTION:
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
90-120 VAC
50/60 HZ.
CAUTION-RISK OF
ELECTRIC SHOCK
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
TELECOMMUNICATION WIRING.
MODULE 1
MODULE 2
MODULE 3
MODULE 4
MODULE 5
MODULE 6
CONTROL
/CHAIN
IN OUT
IN OUT MON NETWORK
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
O
I
5A/250V
CAUTION:
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
90-120 VAC
50/60 HZ.
CAUTION-RISK OF
ELECTRIC SHOCK
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
TELECOMMUNICATION WIRING.
DUAL FXO PORT X.2
PORT X.3 PORT X.4
DUAL
FXO
PORT X.1 PORT X.2
DUAL FXO PORT X.2
PORT X.3 PORT X.4
DUAL
FXO
PORT X.1 PORT X.2
DUAL FXO PORT X.2
PORT X.3 PORT X.4
DUAL
FXO
PORT X.1 PORT X.2
DUAL FXO PORT X.2
PORT X.3 PORT X.4
DUAL
FXO
PORT X.1 PORT X.2
DUAL FXO PORT X.2
PORT X.3 PORT X.4
DUAL
FXO
PORT X.1 PORT X.2
DUAL FXO PORT X.2
PORT X.3 PORT X.4
DUAL
FXO
PORT X.1 PORT X.2
CAUTION-RISK OF
ELECTRIC SHOCK
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
TELECOMMUNICATION WIRING.
MODULE 1
MODULE 2
MODULE 3
MODULE 4
MODULE 5
MODULE 6
P
W
R
A
P
W
R
B
CONTROL
/CHAIN
IN OUT
10 BASE T
IN OUT MON NETWORK
CAUTION:
MAINTENANCE TO BE
PERFORMED BY TRAINED
SERVICE PERSONEL ONLY
ALL EMPTY SLOTS MUST BE
COVERED WITH BLANK PANELS
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
O
F
F
O
N
90-120 VAC
50/60 HZ.
.7A MAX
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
O
F
F
O
N
90-120 VAC
50/60 HZ.
.7A MAX
DUAL FXO PORT X.2
PORT X.3 PORT X.4
DUAL
FXO
PORT X.1 PORT X.2
DUAL FXO PORT X.2
PORT X.3 PORT X.4
DUAL
FXO
PORT X.1 PORT X.2
DUAL FXO PORT X.2
PORT X.3 PORT X.4
DUAL
FXO
PORT X.1 PORT X.2
DUAL FXO PORT X.2
PORT X.3 PORT X.4
DUAL
FXO
PORT X.1 PORT X.2
DUAL FXO PORT X.2
PORT X.3 PORT X.4
DUAL
FXO
PORT X.1 PORT X.2
DUAL FXO PORT X.2
PORT X.3 PORT X.4
DUAL
FXO
PORT X.1 PORT X.2
MODULE 1
MODULE 2
MODULE 3
MODULE 4
MODULE 5
MODULE 6
CONTROL
/CHAIN
IN OUT
IN OUT MON NETWORK
O
I
5A/250V
CAUTION:
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
-48V@1A
+–
CAUTION-RISK OF
ELECTRIC SHOCK
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
TELECOMMUNICATION WIRING.
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
MODULE 1
MODULE 2
MODULE 3
MODULE 4
MODULE 5
MODULE 6
CONTROL
/CHAIN
IN OUT
IN OUT MON NETWORK
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
O
I
5A/250V
CAUTION:
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
90-120 VAC
50/60 HZ.
CAUTION-RISK OF
ELECTRIC SHOCK
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
TELECOMMUNICATION WIRING.
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
CAUTION-RISK OF
ELECTRIC SHOCK
SUPPLEMENTAL EARTH GROUND MUST BE
CONNECTED PRIOR TO CONNECTION OF
TELECOMMUNICATION WIRING.
MODULE 1
MODULE 2
MODULE 3
MODULE 4
MODULE 5
MODULE 6
P
W
R
A
P
W
R
B
CONTROL
/CHAIN
IN OUT
10 BASE T
IN OUT MON NETWORK
CAUTION:
MAINTENANCE TO BE
PERFORMED BY TRAINED
SERVICE PERSONEL ONLY
ALL EMPTY SLOTS MUST BE
COVERED WITH BLANK PANELS
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
O
F
F
O
N
90-120 VAC
50/60 HZ.
.7A MAX
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
O
F
F
O
N
90-120 VAC
50/60 HZ.
.7A MAX
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
DUAL FXS PORT X.2
PORT X.3 PORT X.4
DUAL
FXS
PORT X.1 PORT X.2
/