The Frigidaire FFHS2313LE side-by-side refrigerator is a feature-rich appliance designed to keep your food fresh and organized. With its adjustable temperature-controlled drawers, you can customize the storage environment for different types of food, ensuring optimal preservation. The humidity-controlled crisper drawers help maintain the freshness of fruits and vegetables, while the spacious freezer compartment provides ample room for frozen goods. The refrigerator also boasts an ice maker and water dispenser, offering easy access to chilled water and fresh ice.

The Frigidaire FFHS2313LE side-by-side refrigerator is a feature-rich appliance designed to keep your food fresh and organized. With its adjustable temperature-controlled drawers, you can customize the storage environment for different types of food, ensuring optimal preservation. The humidity-controlled crisper drawers help maintain the freshness of fruits and vegetables, while the spacious freezer compartment provides ample room for frozen goods. The refrigerator also boasts an ice maker and water dispenser, offering easy access to chilled water and fresh ice.

PERFORMANCE DATA
NO LOAD & NO DOOR OPENINGS AT MID-POINT
CONTROL SETTING
Type A with Run/Start Capacitor 65ºF (18ºC) Ambient 90ºF (32ºC) Ambient
Operating Time 32 to 40% 55 to 65%
Freezer Temperature 0º to 4ºF (-18º to -16ºC) -1º to 3ºF (-18º to -16ºC)
Refrigerator Temperature 34º to 39ºF (1º to 4ºC) 34º to 39ºF (1º to 4ºC)
Low Side Pressure (cut-in) 5 to 12 psig (34 to 83 kPa) 5 to 12 psig (34 to 83 kPa)
Low Side Pressure (cut-out) -2 to 2 psig (-14 to 14 kPa) -2 to 2 psig (-14 to 14 kPa)
High Side Pressure
(Last 1/3 of cycle)
90 to 115 psig
(621 to 793 kPa)
130 to 155 psig
(896 to 1069 kPa)
Wattage (Last 1/3 of cycle) 120 to 150 130 to 160
Amps (Running) 1.2 to 1.5 1.2 to 1.5
Base Voltage 115 vac (127 vac max) 115 vac (127 vac max)
Refrigerant Change 4.25 oz. (121 g)
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat Heater
Cut-In Cut-Out Watts Ohms
23’ & 26’ 25ºF (-4ºC) 47ºF (8ºC) 450 30
Electronic Timer - (ADC) Defrost 24 minutes every 6 to 72 hours of compressor run time.
CONDENSER FAN MOTOR
Watts RPM Amps
3.1 (Energy Star - Some models) 1100 CW Opposite Shaft .03 Running
8.0 2550 CW Opposite Shaft .07 Running
ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max) 60 Hertz
Thermostat Opens at 48ºF (9ºC) Closes at 15ºF (-9ºC)
Heater Wattage 165
ICE MAKER PLUG CONNECTIONS
Wire Number Wire Color Connect to:
1 Green/Yellow Ground
2 Yellow Water Valve
3 Black Line
4 Lt. Blue Neutral
SERVICE DATA SHEET
808662201
ICE & WATER - AUTOMATIC DEFROST
SIDE BY SIDE MODELS - R134a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons
should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord
before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original
position and properly secured.
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to
touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will
distort the plastic liner.
ICE MAKER INFORMATION
Test Cycling: Remove cover by inserting screw-
driver in notch at bottom and prying cover from
housing. Use screwdriver to rotate motor gear
counterclockwise until holding switch circuit is
completed. All components of ice maker should
function to complete the cycle.
Water Fill Volume: The water fill adjustment
screw will change the fill time. One full turn is
equal to 20cc (.68 oz.). The correct fill is 102 to
130cc (3.4 to 4.3 oz.). When a water valve is
replaced, the fill volume must be checked.
SERVICE MODE
Activate:
Press and hold FRZ UP then press FRZ DOWN 3 times within 6 sec. Input is recognized
once FRZ UP is released. Press FRZ UP or DOWN to change test.
Deactivate:
Press and hold FRZ UP for 5 seconds. Diagnostic mode will automatically deactivate after 5
minutes of inactivity.
Press FRZ UP or DOWN to change test.
Press FF UP or DOWN to change between sub tests.
View UI display for results of tests.
Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
Test Test Name Sub Test Test Description
1 Software
--- Display is blank when selecting test.
A Displays last 4 digits of software variant; record sequence.
B Displays last 4 digits of control and housing assembly part number; record sequence.
C Displays software test number.
2
Evaporator
Fan
--- Display is blank when selecting test.
A Turns on evaporator fan, displays “E”.
B Turns off evaporator fan, displays “_”.
3
FZ
Thermistor
--- Display is blank when selecting test.
A Flashes “1” if good, “SH” if shorted, and “OP” if open.
B
Displays current FZ temperature. If technician puts hand around thermistor, the
temperature will rise.
4
FF
Thermistor
--- Display is blank when selecting test.
A Flashes “1” if good, “SH” if shorted, and “OP” if open.
B
Displays current FF temperature. If technician puts hand around thermistor, the
temperature will rise.
5
Damper
Motor
Note: Evaporator fan will be on for the duration of this test to aide in evaluation of the damper.
--- Display is blank when selecting test.
A Damper opens, displays “0”. If there is a switch or motor error, flashes “4”.
B Damper closes, displays “_”. If there is a switch or motor error, flashes “4”.
C
If A or B did not display a “4” this test will display “_” and the motor will not run.
If “4” was displayed in test A or B this test displays “E”, and runs the motor
continuously. If motor movement is not heard, there is a problem with the
motor or motor circuit.
If motor is running, there is a problem with the damper switch or damper
switch circuit.
6 Defrost
--- Display is blank when selecting test.
A Turns on defrost heater, displays “d” if DTT is closed and “_” if DTT is open.
B Turns off defrost heater, displays “_”.
7
Compressor
and
Condenser
Fan
--- Display is blank when selecting test.
A Turns on compressor and condenser fan, displays “C”.
B
Turns off compressor and condenser fan, displays “_” .
Once compressor is turned off it cannot be turned on for 7 minutes. 7 minute
countdown is displayed in test A.
8 Display
--- Display is blank when selecting test.
A Turns on all segements of FF display, FZ display, and all LEDs.
9
Error
History Log
--- Display is blank when selecting test.
A
Displays maximum of 8 errors from the last 10 days. If there are no errors,
displays “-” on single digit and “- -” on dual digit.
B Flashes bottom and middle segments. Press and hold FF DOWN to erase history.
TEST 9 ERROR CODES
Error
Error History Log Codes
3 Open FZ Thermistor
4 Shorted FZ Thermistor
5 Damper did not move from close to open position in allotted time
6 Damper did not move from open to close position in allotted time
15 DTT Connector Out or Shorted DTT
23 User Interface Key Stuck Down
24 Open FF Thermistor
25 Shorted FF Thermistor
26 FZ High Temperature Alarm
27 FF High Temperature Alarm
33 Heater, Heater Circuit, Heater Wiring, or DTT Problem
ERROR CODES
Display
FZ FF
Flashing
OP --- Open FZ Thermistor
--- OP Open FF Thermistor
SH --- Shorted FZ Thermistor
--- SH Shorted FF Thermistor
Solid
HI --- FZ Temp. above 26ºF
--- HI FF Temp. above 55ºF
SPECIAL MODES
Display
FZ FF
Manual
Defrost
d F
Press and hold FRZ UP; then press
FF DOWN key 5 times within 5 sec.
Input is recognized when FRZ UP is
released. Same to deactivate.
Showroom
77 77
Press and hold FF UP; then press
FF DOWN 3 times within 5 sec.
Displays will flash “0” “0”. Press
FRZ UP within 5 sec. Requires
Power-on-Reset to deactivate.
Service No
Display
Press and hold FRZ UP; then press
FRZ DOWN 3 times within 6 sec.
Press and hold FRZ UP key for 5
sec. to deactivate. Automatically de-
activates after 5 minutes of inactivity.
TEMPERATURE/RESISTANCE CHART
FOR FRESH FOOD AND FREEZER THERMISTORS
°F kOHMS °F kOHMS °F kOHMS °F kOHMS
-10 11.75 11 60.48 32 32.51 53 18.27
-9 11.41 12 58.52 33 31.53 54 17.84
-8 11.01 13 56.94 34 30.74 55 17.34
-7 10.69 14 55.11 35 29.82 56 16.93
-6 10.32 15 53.34 36 29.07 57 16.39
-5 10.02 16 51.91 37 28.21 58 16.08
-4 96.79 17 50.25 38 27.51 59 15.64
-3 93.47 18 48.92 39 26.70 60 15.21
-2 90.80 19 47.37 40 26.04 61 14.86
-1 87.71 20 46.12 41 25.28 62 14.46
0 85.22 21 44.67 42 24.54 63 14.13
1 82.34 22 43.50 43 23.94 64 13.74
2 80.02 23 42.14 44 23.25 65 13.43
3 77.34 24 40.83 45 22.67 66 13.07
4 75.18 25 39.77 46 22.03 67 12.78
5 72.68 26 38.55 47 21.50 68 12.44
6 70.27 27 37.56 48 20.89 69 12.10
7 68.33 28 36.41 49 20.39 70 11.84
8 66.08 29 35.48 50 19.81 71 11.52
9 64.27 30 34.40 51 19.25 72 11.27
10 62.17 31 33.53 52 18.80 73 10.97
REFRIG. LIGHT
FF THERMISTOR
FRZ THERMISTOR
RL1
BLK
RED
AIR FILTER FAN
ICE & WATER CONTROL BOARD
NEUTRAL
LINE
DISPENSER HOUSING HEATER
1
J6
1
1
J2
6
1
PURPLE (CUBE)
BLUE/WHT (LINE)
LT. BLUE (AUGER)
RED/BLK (NEUTRAL)
TAN (WATER VALVE)
DISPENSER
LED
BLACK
WHT/GRY
BLK
WHT/GRY
TAN
TAN
TAN/BLK
TAN/BLK
WHT
WHT
RED
RED
J3
1
WATER DISP. SWITCH
NC
NO
NO
NC
COMM
COMM
ICE DISP. SWITCH
ELECTRO-MECHANICAL DISPENSER
RED/BLK (120 VAC)
ICE DISP. SWITCH
NO
NO
COMM COMM
NC
NC
WATER DISP.
SWITCH
PURPLE (AUGER)
TAN (WATER VALVE)
PTC STARTER WITH RUN CAPACITOR
CAPACITOR IS ONLY USED WITH
SOME P.T.C. MODELS
LT. BLU
RED
GRN/YEL
RUN CAPACITOR
START
RUN
OVERLOAD COMP.
MOTOR
PTC
STARTER
S S
6
5
C
M M
L
3
2
1
*
*
(LINE)
(NEUTRAL)
DAMPER ASSEMBLY
EVAP. FAN
COIL HEATER
DEFROST
THERM.
COND. FAN
GAMMA
CONTROL
M
J7
J10-1
J10-2
J10-3
J10-4
SEE
COMPRESSOR
WIRING
RED
GREEN
B
COMPRESSOR
CONTROL
RELAY
J1-9
J1-7
J1-1
J1-5
J6-1
J6-2
J1-4
J1-3
J1-8
J1-10
AUTO
ICE MAKER
SEE
DISPENSER ASS’Y
WIRING
I/M WATER VALVE
DISPENSER WATER VALVE
MAIN WATER VALVE
AIR
FILTER
GAMMA CONTROL
M
FF CONTROL
HOUSING
LIGHT
SEE
DISPENSER ASS’Y
WIRING
LT. BLUE
LT. BLUE
LT. BLUE
YEL/BLK
LT. BLUE
RED
BLU/WHT
TAN
LT. BLUE
BLUE
1
BROWN
BROWN
2
J7
J1
1 NEUTRAL
2 OPEN
3 LINE
BLACK
BLACK
BLACK
BLACK
YEL/BLK
YEL/BLK
GRN/YEL
GRN/YEL
RED/WHT
RED/WHT
ORG/WHT
BLUE
RED
RED
RED/BLK
YEL/RED
YEL/BLK
BLU/WHT
4 EVAP FAN
5 DAMPER
6 FAST ICE/FZ
DEFROST
ORN/WHT
7 THERM
8 FF DOOR
9 HEATER
10 FZ DOOR
LINE
FF NTC
FZ NTC
J10
COMP
PURP/WHITE
RED/BLK
RL1
J6
GREY
1
2
3
4
1
2
3
4
5
6
7
8
9
SW
ACTUATOR, ICE DOOR
MOTOR, AUGER
HEATER, ICE DOOR
MID-LEVEL LIGHT
CRISPER LIGHT
FRZR LIGHT
REFRIG. LIGHT
FREEZER LIGHT/
SAFETY SWITCH
DAMPER
MOTOR
GRN/YEL
LT. BLUE
LIGHT SWITCH
(REFRIG.)
ICE MAKER
LT. BLUE
LT. BLUE
YELLOW
YEL/RED
PURPLE
YEL/RED
AUGER
ASS’Y
FRZ
LIGHT
S2 S3 S4
S3
S1
NO NO NO NO NONC
NC NC NC NC
CUBE CRUSH
LIGHT
RESET LOCKOUT
CRISP.
LIGHT
MID-LEVEL
LIGHT
COND. FAN
COMPRESSOR
GROUND
CABINET
GROUND
YEL/BLK
LT. BLUE
SEE
COMPRESSOR
WIRING
PURPLE
LIGHT SWITCH
(FRZR)
RIBBED
NON-RIBBED
BLACK
LT. BLU
LT. BLU
YEL/BLK
TAN
YELLOW
YELLOW
WATER
DISPENSER
VALVE
BROWN
BROWN
WATER
VALVE
RED
RED/WHT
BLUE
GREEN
I/M
WATER
VALVE
GRN/YEL
ALL WIRE CONNECTIONS
MARKED BY “
o”SYMBOL.
DRAIN
TROUGH
DEFROST HEATER
DEFROST
THERM.
FRZR.
FAN
DIODES TO BE
POLARIZED AS SHOWN
SPLICE
DIODE
DIODE
REFRIG. LIGHT SWITCH
242300701 Wiring Diagram
  • Page 1 1
  • Page 2 2

Frigidaire FFHS2313LE Product information

Type
Product information

The Frigidaire FFHS2313LE side-by-side refrigerator is a feature-rich appliance designed to keep your food fresh and organized. With its adjustable temperature-controlled drawers, you can customize the storage environment for different types of food, ensuring optimal preservation. The humidity-controlled crisper drawers help maintain the freshness of fruits and vegetables, while the spacious freezer compartment provides ample room for frozen goods. The refrigerator also boasts an ice maker and water dispenser, offering easy access to chilled water and fresh ice.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI