AquaPower AQE 8/10, AQE 12 User guide

  • Hello! I am an AI chatbot trained to assist you with the AquaPower AQE 8/10 User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
17 West Street | West Hatfield, MA 01088 | Toll Free 800.582.2213 | Phone 413.247.3380 | Fax 413.247.3369 | info@aptankless.com | www.aptankless.com
1.5
1.0
High
0.75
Med
Lavatory Sink
Kitchen Sink
Flow
GPM
at 7.2 kW at 9.6 kW
AQE 12
Std.
Low
Low
Low
Med
Std.
High
Non-
Code
Std.
0.5
0.5
1.0
1.0
2.0
1.5
1.0 - 2.0
2.5
2.0 - 3.0
1.5
*Max. number of sinks that can be serviced by one unit
*5 *4
*2
1 Shower
Multiple Sinks
Utility/
Janitor
Sink
Recommendations for 240 V
units are correct if installed
with 240 V service.
Increase one model size if
unit will be installed with
208 V service.
Call Aqua Power® at 800.582.2213 if you
have any sizing questions, or an
out-of-the-ordinary situation. Aqua Power®
service representatives can make recom-
mendations on sizing, or provide assistance
with our water heaters, to both homeowners
and professional installers.
FL
Cool (Northern) Climate
Inlet water
45°F - 55°F
Cool (Northern) Climate
Inlet water
45°F - 55°F
Warm (Southern) Climate
Inlet water
55°F - 70°F
HI
AK
MB
ON
QC
PE
NS
NH
VT
MA
CT
RI
NJ
DE
MD
NB
ME
NY
PA
WV
VA
NC
KY
TN
SC
GA
MS
AL
MO
AR
LA
TX
FL
OH
IN
IL
ID
OR
WA
NV
MT
WY
UT
AZ
CA
NM
CO
IA
MN
ND
SD
NE
KS
OK
MI
WI
AB
SK
BC
*4 *3*3 *2
AQE Sizing Guide
Single or Multiple Point Tankless Electric Water Heater
240 V
Requires 60 A
circuit breaker
240 V
Requires 50 A
circuit breaker
240 V
Requires 40 A
circuit breaker
AQE 8/10
‡ AQE 8/10 is a single unit that is switchable at installation
via jumper for output at 7.2 kW (Stage 1) or 9.6 kW (Stage 2).
17 West Street | West Hatfield, MA 01088 | Toll Free 800.582.2213 | Phone 413.247.3380 | Fax 413.247.3369 | info@aptankless.com | www.aptankless.com
Model AQE 8/10
1
@ 7.2 kW AQE 8/10
1
@ 9.6 kW AQE 12
Item No. 612444 612444 612445
Phase
- 60/50 Hz 1
Voltage 240
V or 208 V 240 V or 208 V 240 V or 208 V
Wattage 7. 2 kW 5.4 kW 9.6 kW 7. 2 kW 12.0 kW 9.0 kW
Amperage draw 30 A 26 A 40 A 35 A 50 A 44 A
Required circuit breaker
size (double pole)
2
40 A 40 A 50 A 40 A 60 A 50 A
Required wire
size, (copper)
3
8 AWG 8 AWG 8 AWG 8 AWG 6 AWG 6 AWG
Minimum water ow to
activate unit
0.37 GPM
1.4 l/min
Volume of water in unit 0.13 gal / 0.5 l
Maximum inlet water
temperature
131°F / 55°C
Weight 5.9
lb / 2.7 kg
Dimensions (H x W x D) 14
3
/
16
” / 360 mm x 7
7
/
8
” / 200 mm x 4
1
/
8
” / 104 mm
Working pressure 150
psi / 10 BAR
Tested to pressure 300 psi / 20 BAR
Plumbing connections ½” NPT
1 Single unit, switchable between 7.2 kW and 9.6 kW at installation via jumper
2 This is our recommendation as the manufacturer. Check local codes for compliance if necessary. Tankless water heaters are
considered a non-continuous load
3 Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
AQE Series Technical Data
ISO 9001
CERTIFIED
The Aqua Power AQE series is tested and
certied by WQA against NSF/ANSI 372
for lead free compliance.
Conforms to ANSI/UL Std. 499
Certied to CAN/CSA E335-1 &
E335-2-35
/