17 West Street | West Hatfield, MA 01088 | Toll Free 800.582.2213 | Phone 413.247.3380 | Fax 413.247.3369 | info@aptankless.com | www.aptankless.com
Model AQE 8/10
1
@ 7.2 kW AQE 8/10
1
@ 9.6 kW AQE 12
Item No. 612444 612444 612445
Phase
- 60/50 Hz 1
Voltage 240
V or 208 V 240 V or 208 V 240 V or 208 V
Wattage 7. 2 kW 5.4 kW 9.6 kW 7. 2 kW 12.0 kW 9.0 kW
Amperage draw 30 A 26 A 40 A 35 A 50 A 44 A
Required circuit breaker
size (double pole)
2
40 A 40 A 50 A 40 A 60 A 50 A
Required wire
size, (copper)
3
8 AWG 8 AWG 8 AWG 8 AWG 6 AWG 6 AWG
Minimum water ow to
activate unit
0.37 GPM
1.4 l/min
Volume of water in unit 0.13 gal / 0.5 l
Maximum inlet water
temperature
131°F / 55°C
Weight 5.9
lb / 2.7 kg
Dimensions (H x W x D) 14
3
/
16
” / 360 mm x 7
7
/
8
” / 200 mm x 4
1
/
8
” / 104 mm
Working pressure 150
psi / 10 BAR
Tested to pressure 300 psi / 20 BAR
Plumbing connections ½” NPT
1 Single unit, switchable between 7.2 kW and 9.6 kW at installation via jumper
2 This is our recommendation as the manufacturer. Check local codes for compliance if necessary. Tankless water heaters are
considered a non-continuous load
3 Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
AQE Series Technical Data
The Aqua Power AQE series is tested and
certied by WQA against NSF/ANSI 372
for lead free compliance.
Conforms to ANSI/UL Std. 499
Certied to CAN/CSA E335-1 &
E335-2-35