Watts RDC24R Installation guide

Type
Installation guide

This manual is also suitable for

This Restraining Device Must Always Be
Connected When the Appliance Is in Service
The restraining device should be disconnected for move m e n t ,
such as, servicing or cleaning, o n ly after gas has been shut
off and the connector has been disconnected!
Reconnect restraining cable b e fo r e reconnecting the gas
connector and moving back to its original position.
Installation Instructions for
RESTRAINING DEVICE
(For Use with Castered Appliances)
Restraining Device Required per the Following Standards:
ANSI Z21.69/CSA 6.16 Gas Connectors for Moveable Gas Appliances
ANSI Z21.41/CSA 6.9 Quick Disconnect Devices
ANSI Z83.11/CGA 1.8 Commercial Gas Ranges
ANSI Z83.12/CGA 1.9 Commercial Gas Ovens
ANSI Z83.13 Commercial Gas Fryers
ANSI Z223.1/NFPA 54 National Fuel Gas Code Section 5.5.1.e
CSA - B149.1 Natural Gas and Propane Installation Code
Please refer to installation instructions tag on every connector for detailed
information, as specified in ANSI Z21.69/CSA 6.16
Note: The gas connector must be installed in accordance with the National Fuel
Gas Code (ANSI Z223.1/NFPA 54) and any State or Local Code requirements.
Dormont Manufacturing Company makes no warranty, representation or
condition of any kind, express or implied (including any warranty of merchantabili-
ty or of fitness) and none shall be implied by law. Dormont shall not be liable for
incidental or consequential damages.
Call 1-800-DORMONT (367-6668) for additional information
1 . R e s t r aining Device should be installed parallel (in line) with the gas
appliance connector.
2 . Attach the staple bra c ket (C) to a stud in the wall, using the four 1'' #10
s c r e ws (D) and the plastic anchors (E), if needed.
3 . Locate a stru c t u r al area (frame) on the rear side of the equipment that is in
line with the wall attachment. Drill a small hole 1/4'' (per manu f acturers’
recommendation). Please use caution when drilling hole, so that intern a l
components are not damaged.
4 . Thread the hex nut (G) and slide one washer (I) onto the eye-bolt (F).
Slide the eye-bolt through the drilled hole and place a washer (I) and the
nylon lock nut (H) onto the eye-bolt on the inside frame of the equipment and
tighten securely.
5 . Attach one of the spring-loaded hooks (B) to the mounted bra c ket on the wa l l
(Step 2) and the other to the eye-bolt (Steps 3 and 4).
N o t e : For adjustable restraining dev i c e s , the cable is manu factured to be
s h o r ter than the length of the gas connector.
6015 Enterprise Drive, Export, PA 15632
724-733-4800 FAX: 724-733-4808
w w w . d o r m o n t . c o m
D
1'' #10 Screws
(4)
E
Plastic Anchors
(4)
H
1/4'' Nylon Lock Nut
G
1/4'' Hex Nut
I
1/4'' x 1 1/4''
Washers
(2)
C
Staple Bracket
B
Spring Loaded Hook
A
Restraining
Cable
with Two
Snap Hooks
B
Spring Loaded Hook
F
Eye-bolt
A
F
B
B
C
Wall
Appliance
DM147A, REV. 5, 7/05
DM147A, Rev 5, 7-05 7/25/05 12:41 PM Page 1