LG LA150HYV2 LA150HYV2 Submittal

  • Hello! I am an AI chatbot trained to assist you with the LG LA150HYV2 LA150HYV2 Submittal. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Date:
JobName/Location:
PONo.:
Architect:
Engr:
GC:
Rep:
For:
File
A
pp
roval
Mech:
Resubmit
Other
Ta g#:
(Company)
(ProjectManager)
SingleZoneWallMountedArtCool™Premier
LA150HYV2
Performan ce:
Capacity(MinRatedMax,Btu/h)
3,07015,00021,000
SEER
24
EER
13.48
Cooling:
Heating:
Capacity(MinRatedMax,Btu/h)
3,07018,00025,200
HSPF
12.5
CoolingNominalTestConditions: HeatingNominalTestConditions:
Indoor:
80°FDB/67°FWB
Indoor:
70°FDB/60°FWB
Outdoor:
95°FDB/75°FWB
Outdoor:
47°FDB/43°FWB
Electrical:
MCA(A)
19
MOP(A)
25
Compressor(A)
14.5
FanMotor(A)
0.5
OutdoorUnit:
CoolingRatedAmps(A)
15.0
HeatingRatedAmps(A)
15.0
CoolingPowerInput(kW)
1.113
HeatingPowerInput(kW)
1.385
Piping:
LiquidLine(in,OD)
3/8
AdditionalRefrigerant(oz/ft)
0.38
MaxElevation(ft)
65.6
PipingLengt h(noadd'lrefrigerant,ft)
24.6
ControlsFeatures:
•24Houron/offmer
•4Wayautoswing
•Autochangeover
•Autorestart
•Builtinlowambient
operationto14°F
•Chaoswind
•Selfdiagnosis
•Sleepmode
•Sodryoperaon
•Ultraquietoperaon
•Coolingonlyfunction
•3MMicroProtectionFilter
•SmartACmodule
Page1of3
Forcontinualproductdevelopment,LGreservestherig httochang es pecificationswithoutnotice.
©LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lghvac.com
PowerSupply(V¹/Hz/Ø)
208230/60/1
VaporLine(in,OD)
5/8
OperatingRange:
OutdoorUnit:
Cooling(°FDB)
14118
Heating(°FWB)
1365
Cooling(°FWB)
5375
Heating(°FDB)
6086
IndoorUnit:
UnitData:
RefrigerantType
R410A
RefrigerantCharge(lbs)
4.19
Fan:
Notes:
1.Acceptableoperangvoltage:187V‐253V.
2.Pipinglengthsareequivalent.
3.SoundPressurelevelsaretestedinananechoicchamberunderISOStandard1996.
4.Allpower/communicaoncabletobeminimum18Americanwiregage(AWG),4
conductor,
stranded,shieldedorunshieldedwireandmustcomplywithapplicablelocalandnational
code.
Ifshielded,thewiremustbegroundedtothec hassisattheoutdoorunitonly.
5.SeeEngineeringManualforsensibleandlatentcapacies.
6.Powerwiringcablesizemustcomplywiththeapplicablelocalandnaonalcode.
7.Theindoorunitcomeswithadryheliumcharge.
8.Thisdata
israted0abovesealevel,with24.6ofrefrigerantlineanda0level
differencebetweenoutdoorandindoorunits.
9.MustfollowinstallaoninstruconsintheapplicableLGinsta llaonmanua l.
ODUType
Propeller
IDUType
CrossFlow
Motor/Drive
B rushlessDigitallyControlled/Direct
Dehumidification(pts/hr)
3.8
RefrigerantControl
EEV
HeatExchangerCoating
GoldFin™
ODUNetUnitWeight(lbs)
122
ODUShippingWeight(lbs)
131
IDUNetUnitWeight(lbs)
34
IDUShippingWeight(lbs)
38
FanSpeeds(Fan/Cooling/Heating)
6/6/6
Quantity(ODU+IDU)
1+1
Cooling,Max/H/ M/L(CFM)
741.5/565.0/423.7/317.8
ODUMaxAirFlowRate(CFM)
2119
Cooling( H /M/L/Sleep)±3dB(A) ³
47/42/37/29
ODUSoundPressure(Max)±3dB(A) ³
57
O
p
tionalAccessories
(
soldse
p
aratel
y)
:
•Condensatesensor
connection
•Defrostcontrol
•Dehumidifyingmode
•Hotstart
•Jetcool/Jetheat
•Selfcleaningindoorcoil
SB_SZ_WM_ArtCool_Premier_LA150HYV2_1 2_16
IndoorUnit(IDU)‐LAN150HYV2OutdoorUnit(ODU)‐LAU150HYV2
SEER‐SeasonalEnergyEfficiencyRatio EER‐EnergyEfficiencyRatio
HSPF‐HeatingSeasonalPerformanceFactor
MOP‐MaximumO vercurrentProtection MCA‐MinimumCircuitAmpacity
DryCon tactforthirdpartythermostat‐PDRY CB300
LGProgrammableThermostat‐PREMTB10U
TotalPowerInput:
Min/MaxPipeLength(ft)²:
9.8
/
98.4
Foracompletelistofavailableaccessories,contactyourLG representative.
PI485‐PMNFP14A1
LowAmbientWindBaffle(Coolingoperationto0°F)‐ZLABGP02A
Heating,Max/H/M/L(CFM )
776.9/600.3/459.0/353.1
IDUAirFlow
IDUSoundPressure
Heating(H /M/L) ±3dB( A) ³
47/42/37
JobName/Location:
Tag#:
Date:
PONo.:
SingleZoneWallMountedArtCool™Premier
Page2of3
Forcontinualproductdevelopment,LGreservestherig httochang es pecificationswithoutnotice.
©LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lghvac.com
OutdoorUnit(ODU)‐LAU150HYV2
SB_SZ_WM_ArtCool_Premier_LA150HYV2_1 2_16
JobName/Location:
Tag#:
Date:
PONo.:
SingleZoneWallMountedArtCool™Premier
IndoorUnit
(
IDU
)
‐LAN150HYV2
Page3of3
Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice.
©LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lghvac.com
SB_SZ_WM_ArtCool_Premier_LA150HYV2_12_16
/