MacroAir Technologies AIRSTAR User manual

Type
User manual
TM
AIRSTAR
Table Of Contents
1. Cautions And Safety
2. Package Contents
3. Tools Needed
4. Fan Clearance / Placement
5. I-beam Mounting
6. Glulam Mounting
7. Spanning Mount / Mount Assembly
8. Extention Assembly
9. Blades/ Blade Retainers
10. Blade Retainer Assembly
11. Wiring guide/ Cat5 B
Caution and Safety
pg 1.
READ AND FOLLOW THIS MAUAL BEFROE OPERATING THE FAN.
Read these safety practices before installing, operating or servicing the fan. failure to follow these
safety practices could result in death or serious injury.
Be certain to follow the instructions in this manual. If you do not understand the instructions please
call our Technical department for help.
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
- Read and understand this manual before installing or operating. Installation, adjustment, reapair,
maintenance must be performed by qualied personel.
- The user is responcable for compliance with all international and national electrical code
requirements with respect to grounding of all equipment.
- Many of the part of this unit operat at line voltage. DO NOT TOUCH.
-Install all covers before applying power or starting and stopping the unit.
DAMAGED EQUIPMENT
Do not operate or install any fans or fan Accesory that appears to be damaged.
Failure to folow these instruction can result in death, serious injury, or equipment damage.
MAINTENANCE AND SERVICE:
If the fan does not operate properly useing the procedures in this manual, BE CERTAIN TO
REMOVE ALL POWER TO THE UNIT and contact our technical department for futher assistance.
Keep all body clear of moving part at all times.
All electrical troubleshooting and repair must be done by a qualied technician and meet all
applicable codes.
Package Contents
Power Unit
Image of Hardware and Mount
Remote pg 2.
1. Socket set and ractchet (deep and short wall)
2. 3/8 allen key
3. Magnetic level
4. Phillips and Flat Head Screw driver
5. Network crimping tool (if standard connection will not work.)
6. Torque Wrench (Not Shown)
Tools Required
3.
1.
2.
4.
5.
pg 3
Roof Slope=
Rise/Run
Fan Diameter
Run=12"
Rise=?"
NO OBSTRUCTIONS IN THIS AREA
(15% OF FAN DIAMETER)
Total fan height
approximately19.5"
The extension lengths below are minimum recomendations only, based soley on roof
pitch and fan diameter. Other consideration must be evaluated when determining
extension requirements, such as placement of lights, sprinklers systems, HVAV systems
and so on. In addition, OSHA requirements state that fan blade must be a minimum of 10
feet (3.05 Meters) above the floor. Contact our sales department for assistance with fan
placment and extension selection.
Fan Clearance And Extension Guide
Slope
2/12 4/12 6/12 8/12
10/12
Roof Anlgle
9.5 18.4 26.6 33.7 39.8
Fan
Diameter
Recomended Length
Clearance
Zone Radius
8
1 ft 1 ft 2 ft 3 ft 4 ft
14.5"
10
1 ft
2 ft 3 ft 4 ft 5 ft
18"
12
2 ft
3 ft 4 ft 5 ft 6 ft
32.5"
pg 4
I-beam Mounting
I-Beam Assembly
Exploded View
For installations with I-beams use MacroAir I-beam
Kit (PN 60-50106-00). To properlly install mount be
sure to use hang mount along slope of the roof.
For ease of installation the Unistrut for our I-beam mount can be installed in two differant
congurations. Refer to images above for examples.
pg 5
Glulam Mounting
Glulam Assembly
Exploded View
Glulam Installation utilizes unistrut in conjunction with our Glulam bracket for installations
containing glulam beams.
Installation on Glulam beams will use MacroAir
Glulam Mounting Kit (PN 60-50108-00).
Installing the mount alonge the slope of the roof
will allow the proper leveling of the fan.
pg 6
Model of spanning mount
Loosely install the mount hardware prior to
installing fan. Once the fan is installed and level,
tighten mount hardware down.
Spanning Mount also utilizes
Unistrut for spanning mount
installations.
Power Unit Mount Exploded View
pg 7
Extension Assembly
Exploded View
When Extension is needed assemble between mount and power unit with provided hardware.
(refer to chart on pg 4 for size recomendations)
pg 8
While installing blades be sure to install the blade reatainer links by over lapping the
reatainers. Refer to image above for exploded view. Blade bolts must be torqued to 23
ft lbs.
Blade Retainer
Installation
pg 9
Blade Assembly
Image
This image represents the correct installation of the Blade and Blade reatainer
links.
pg 10
Cat5 B pinout chart
A coulpler may also be use
to extend the length of the
remote cable connection. In
the case where a long CAT5
cable is required please
follow the Cat5 B standard.
The Image above show how to
route cables through extension.
The Image above shows the cable from the top of
the Fan
Wiring
When useing an extension route cables
through extension. refer to the images above
pg 11
MacroAir
794 South Allen Street
San Bernardino, Ca 92408
p 909.890.2270
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

MacroAir Technologies AIRSTAR User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI