Vaisala HMD53 User manual

Category
Measuring, testing & control
Type
User manual

Vaisala HMD53 is a three-wire transmitter designed for duct mounting. It is commonly used in building automation applications to measure relative humidity and temperature. The transmitter has various output signal options, including 0...1V, 0...5V, 0...10V, and 0...20mA. The HMD53 is equipped with the Vaisala INTERCAP® sensor, which offers high accuracy and stability. It also features a removable 5-pole screw connector for easy electrical connections. Additionally, the transmitter has an optional current module that allows for 0...20mA output.

Vaisala HMD53 is a three-wire transmitter designed for duct mounting. It is commonly used in building automation applications to measure relative humidity and temperature. The transmitter has various output signal options, including 0...1V, 0...5V, 0...10V, and 0...20mA. The HMD53 is equipped with the Vaisala INTERCAP® sensor, which offers high accuracy and stability. It also features a removable 5-pole screw connector for easy electrical connections. Additionally, the transmitter has an optional current module that allows for 0...20mA output.

© Vaisala 2011. All rights reserved.
*M211386EN*
For warranty information, visit our Internet pages at:
www.vaisala.com/services/warranty.html
QUICK REFERENCE GUIDE
Vaisala INTERCAP® Humidity
and Temperature Transmitter
HMD53
Temperature compensated RH and T
transmitter for ducts in building
automation applications
0 … 100 %RH range
– ±3 %RH accuracy
Various output signal options
Uses the Vaisala INTERCAP®
sensor, no recalibration needed
when sensor is replaced
MOUNTING
The HMD53 humidity and temperature transmitter is a three-
wire transmitter. HMD53 is duct mounted, and the electronics
can be disconnected without dismantling the installation.
Mount the transmitter with two screws. Place the drilling
template on the duct surface and drill the holes as indicated.
100
100
82
82
Ø12
250
60
Figure 1 HMD53 Dimensions
ELECTRICAL CONNECTIONS AND
INSTALLATION OF THE CURRENT MODULE
Signal cables are connected to a removable 5-pole screw
connector. Make the connections according to Figure 2.
NOTE The trimmers on the component board are
reserved for factory use. Do not touch them.
The HMD53 transmitters can also be connected to an AC supply
without an external rectifier. However, when more than one
transmitter is connected to one AC transformer, a common loop
is formed and there is an increased risk of a short-circuit. To
avoid this, use a separate floating supply for each transmitter
(see Figure 3).
If several transmitters have to share one transformer, the phase
(~) must always be connected to U
s
connector in each transmitter
(see Figure 4).
INSTALLATION OF
THE CURRENT MODULE 18945HM
1. Take off the jumpers
2. Connect the module; note the
right direction!
3. Connect the power supply
OUTPUT SELECTIONS
0...1V
0...5V
0...10V
0...20mA
current
module
T
RH
RH
RH
RH
T
T
T
T
RH
1
1
1
1
23
4
5
current module 0...20 mA
U
U
U
U
Us
RH
out
T
out
GND
V/mA
DC/AC
power supply
V/mA
Figure 2 Electrical Connections
CONNECTION TO AN AC SUPPLY
HMD53 transmitter
Controller
VAC
VAC
Us
GND
signal
RH/T
GND
Us
RH/T
signal
HMD53 transmitter
Figure 3 The Recommended AC Connection
Visit our Internet pages at www.vaisala.com
Ref. M211386EN-A
H
M
D
53 tra
n
smitter
HMD53 transmitter
Controller
shared
commonline
VAC
GND
GND
Us
Us
RH/T
RH/T
signal
signal
Figure 4 Common Loop Formed in an AC Connection
– NOT RECOMMENDED
GROUNDING
Open the lid and mount the cable bushing set. If your transmitter
has a cable gland bushing (part no. 18941HM), do the grounding
according to Figure 2. When connecting the signal cable to the
transmitter housing, fold the cable braid between the brass disk
in order to achieve the best EMC performance.
CAUTION Do not leave the bare shield of the
connected wires so that it can short circuit
the electronics!
Note the following requirements for the signal cable:
- Use a cable with flexible wires, size 0.5 mm
2
(AWG20)
- Stranded wires recommended
- Use a cable with diameter 7 … 10 mm. If the cable
diameter is less than 7 mm, use a shrinking tube or
adhesive tape.
Cable
Braid
0.5 mm² (AWG 20)
stranded wires
recommended
D = Ø 7 ... 10mm
3
Brass
disks
25
Rubber
ring
Nut
Brass disks
140
165
Shielding tube
Braid
Figure 5 Signal Cable Grounding with Bushing 18941HM
ELECTRONICS
10528HM
18941HM
Glands
Lid
Screw terminal
Screws
Membrane filter
part no. DRW010525
Intercap sensor
part no. 15778HM
Stainless steel
sintered filter
part no. HM46670
Figure 6 Electronics, Accessories, Spare Parts
Removing and Reinstalling the Sensor Head
1.
Open the lid.
2.
Disconnect the screw terminal.
3.
Open the screws (2 pcs).
4.
Pull the sensor head out carefully.
5.
To reinstall, push in the sensor head.
6.
Reassemble in reverse order.
Replacement of the Intercap Sensor
If the INTERCAP® sensor is damaged, remove it and insert a
new one. Recalibration is not needed.
If the filter is dirty, replace it to ensure a maximum lifetime and
fast response for the sensor. Do not attempt to clean the filter.
TECHNICAL DATA
Relative Humidity
Measurement range
0 ... 100 %RH
Typical accuracy
Temperature range 0 ... +40 °C (+32 ... +104 °F)
0 ... 90 %RH ±3 %RH
90 ... 100 %RH ±5 %RH
Temperature range -20 ... 0 °C, +40 ... +60 °C
(-4 ... +32 °F, +104 ... +140 °F)
0 ... 90 %RH ±5 %RH
90 ... 100 %RH ±7 %RH
Humidity sensor Vaisala INTERCAP®
Stability ±2 %RH / 2 years
Response time at 20°C (+68 °F), 90% response 15 s
Temperature
Measurement range
-20 ... +60 °C (-4 ... +140 °F)
Output scale
-40 ... +60 °C (-40 ... +140 °F)
Accuracy
0 ... 40 °C (+32 ... +104 °F)
±0.4 °C (±0.72 °F)
-20 ... 0 °C, +40 ... +60 °C
(-4 ... +32 °F, +104 ... +140 °F)
±0.6 °C (±1.08 °F)
Sensor
Pt1000 IEC 751 Class B
General
Supply voltage depends on output signal
Output signal DC AC
0 ... 1 V 10 ... 35 V 9 ... 24 V
0 ... 5 V 14 ... 35 V 12 ... 24 V
0 ... 10 V 19 ... 35 V 16 ... 24 V
With optional current module
0 … 20 mA (
R
L
= 0 )
10 ... 35 V 11 ... 24 V
0 … 20 mA (
R
L
= 500 )
20 ... 35 V 17 ... 24 V
Power consumption @ 24VAC 12 mA typical
Operating temperature range
Electronics
-5 ... +55 °C (+23 ... +131 °F)
Probe
-20 ... +60 °C (-4 ... +140 °F)
Storage temperature range
-40 ... +60 °C (-40 ... +140 °F)
Maximum flow speed
50 m/s
Housing material
Cast aluminium
Probe material
Stainless steel
Housing classification
IP65 (NEMA 4)
Connections
Screw terminals, 0.5 ... 1.5 mm2
Included cable bushing for 7 ... 10 mm (PG9) 18941HM
Complies with EMC standards EN61326-1 and EN55022
  • Page 1 1
  • Page 2 2

Vaisala HMD53 User manual

Category
Measuring, testing & control
Type
User manual

Vaisala HMD53 is a three-wire transmitter designed for duct mounting. It is commonly used in building automation applications to measure relative humidity and temperature. The transmitter has various output signal options, including 0...1V, 0...5V, 0...10V, and 0...20mA. The HMD53 is equipped with the Vaisala INTERCAP® sensor, which offers high accuracy and stability. It also features a removable 5-pole screw connector for easy electrical connections. Additionally, the transmitter has an optional current module that allows for 0...20mA output.