LG UV48W.NL2R0 Owner's manual

Type
Owner's manual

This manual is also suitable for

2
TIPS FOR SAVING ENERGY
ENGLISH
TIPS FOR SAVING ENERGY
Here are some tips that will help you minimize the power consumption when you use the air
conditioner. You can use your air conditioner more efficiently by referring to the instructions
below:
• Do not cool excessively indoors. This may be harmful for your health and may consume more
electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air con-
ditioner is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block
the air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak
performance of your product
WARNING
It can result in serious injury or death when the directions are ignored
CAUTION
It can result in minor injury or product damage when the directions are ignored
WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• The product shall be installed according to the Wiring regulations of the corresponding coun-
try.
• The information contained in the manual is intended for use by a qualified service technician
familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment mal-
function, property damage, personal injury and/or death.
Installation
• Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.
There is risk of fire or electric shock.
• For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service
Center. Do not disassemble or repair the product. There is risk of fire or electric shock.
• Always ground the product. There is risk of fire or electric shock.
• Install the panel and the cover of control box securely. There is risk of fire or electric shock.
• Always install a dedicated circuit and breaker. Improper wiring or installation may cause fire or
electric shock
• Use the correctly rated breaker or fuse. There is risk of fire or electric shock.
• Do not modify or extend the power cable. There is risk of fire or electric shock.
• Do not install, remove, or re-install the unit by yourself (customer). There is risk of fire, electric
shock, explosion, or injury.
• Be cautious when unpacking and installing the product. Sharp edges could cause injury. Be
especially careful of the case edges and the fins on the condenser and evaporator.
• For installation, always contact the dealer or an Authorized Service Center. There is risk of
fire, electric shock, explosion, or injury.
• Do not install the product on a defective installation stand. It may cause injury, accident, or
damage to the product.
• Be sure the installation area does not deteriorate with age. If the base collapses, the air condi-
tioner could fall with it, causing property damage, product failure, and personal injury.
• Do not let the air conditioner run for a long time when the humidity is very high and a door or
a window is left open. Moisture may condense and wet or damage furniture.
!
!
!
3
ENGLISH
4
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
Operation
• Take care to ensure that power cable could not be pulled out or damaged during operation.
There is risk of fire or electric shock.
• Do not place anything on the power cable. There is risk of fire or electric shock.
• Do not plug or unplug the power supply plug during operation. There is risk of fire or electric
shock.
• Do not touch(operate) the product with wet hands. There is risk of fire or electrical shock.
• Do not place a heater or other appliances near the power cable. There is risk of fire and elec-
tric shock.
• Do not allow water to run into electric parts. It may cause There is risk of fire, failure of the
product, or electric shock.
• Do not store or use flammable gas or combustibles near the product. There is risk of fire or
failure of product.
• Do not use the product in a tightly closed space for a long time. Oxygen deficiency could
occur.
• When flammable gas leaks, turn off the gas and open a window for ventilation before turn the
product on. Do not use the telephone or turn switches on or off. There is risk of explosion or
fire
• If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect
the power supply cable. There is risk of electric shock or fire.
• Stop operation and close the window in storm or hurricane. If possible, remove the product
from the window before the hurricane arrives. There is risk of property damage, failure of
product, or electric shock.
• Do not open the inlet grill of the product during operation.(Do not touch the electrostatic filter,
if the unit is so equipped.) There is risk of physical injury, electric shock, or product failure.
• When the product is soaked (flooded or submerged), contact an Authorized Service Center.
There is risk of fire or electric shock.
• Be cautious that water could not enter the product. There is risk of fire, electric shock, or
product damage.
• Ventilate the product from time to time when operating it together with a stove, etc. There is
risk of fire or electric shock.
• Turn the main power off when cleaning or maintaining the product. There is risk of electric
shock.
• When the product is not be used for a long time, disconnect the power supply plug or turn off
the breaker. There is risk of product damage or failure, or unintended operation.
• Take care to ensure that nobody could step on or fall onto the outdoor unit. This could result
in personal injury and product damage.
IMPORTANT SAFETY INSTRUCTIONS
CAUTION
Installation
Always check for gas (refrigerant) leakage after installation or repair of product. Low refrigerant lev-
els may cause failure of product.
Install the drain hose to ensure that water is drained away properly. A bad connection may cause
water leakage.
Keep level even when installing the product. To avoid vibration or water leakage.
Do not install the product where the noise or hot air from the outdoor unit could damage the neigh-
borhoods. It may cause a problem for your neighbors.
Use two or more people to lift and transport the product. Avoid personal injury.
Do not install the product where it will be exposed to sea wind (salt spray) directly. It may cause cor-
rosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause
product malfunction or inefficient operation.
Operation
Do not expose the skin directly to cool air for long periods of time. (Don't sit in the draft.) This could
harm to your health.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a con-
sumer air conditioner, not a precision refrigeration system. There is risk of damage or loss of prop-
erty.
Do not block the inlet or outlet of air flow. It may cause product failure.
Use a soft cloth to clean. Do not use harsh detergents, solvents, etc. There is risk of fire, electric
shock, or damage to the plastic parts of the product.
Do not touch the metal parts of the product when removing the air filter. They are very sharp! There
is risk of personal injury.
Do not step on or put anyting on the product. (outdoor units) There is risk of personal injury and fail-
ure of product.
Always insert the filter securely. Clean the filter every two weeks or more often if necessary. A dirty
filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.
Do not insert hands or other objects through the air inlet or outlet while the product is operated.
There are sharp and moving parts that could cause personal injury.
Do not drink the water drained from the product. It is not sanitary and could cause serious health is-
sues.
Use a firm stool or ladder when cleaning or maintaining the product. Be careful and avoid personal
injury.
Replace the all batteries in the remote control with new ones of the same type. Do not mix old and
new batteries or different types of batteries. There is risk of fire or explosion
Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire. They may burn or
explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not
use the remote if the batteries have leaked. The chemicals in batteries could cause burns or other
health hazards.
• If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if
the batteries have leaked. The chemicals in batteries could cause burns or other health hazards.
!
5
ENGLISH
6
TABLE OF CONTENTS
ENGLISH
TABLE OF CONTENTS
2 TIPS FOR SAVING EN-
ERGY
3 IMPORTANT SAFETY IN-
STRUCTIONS
7 BEFORE USE
7 Preparing for operation
7 Usage
7 Cleaning and maintenance
7 Service
8 PRODUCT INTRODUC-
TION
8 Name and function of parts
8 What to do before operation
8 Operation Indication Lamps
9 Wireless Remote Controller
11 OPERATING INSTRUC-
TION
11 How to insert the Batteries
11 Wireless Remote Controller Mainte-
nance
12 INSTALLATION IN-
STRUCTIONS
12 Installer Setting -How to enter installer
setting mode
13 Installer Setting - Installer Setting
Code Table
14 Installer Setting - Setting Address of
Central Control
14 Installer Setting - Checking Address of
Central Control
15 OWNER'S INSTRUC-
TION
15 Cooling Mode - Standard Operation
15 Cooling Mode - Power Cooling
16 Heating Mode
17 Auto Changeover Mode
17 Auto Changeover Mode - Setting the
Mode Change Temperature
18 Auto Operation Mode
19 Dehumidification Mode
20 Fan Mode
21 Temperature Setting/Room Tempera-
ture checking
22 Airflow Setting
22 Celsius/Fahrenheit Switching
23 Timer
24 MAINTENANCE AND
SERVICE
25 Operation Tips!
25 When the air conditioner is not
going....
26 Troubleshooting Tips! Save time and
money!
26 Call the service immediately in the fol-
lowing situations
BEFORE USE
7
ENGLISH
Preparing for operation
• Contact an installation specialist for installation.
• Use a dedicated circuit.
Usage
• Being exposed to direct airflow for an extended period of time could be hazardous to your
health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
• Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves
or other heating devices.
• Do not use this air conditioner for non-specified special purposes (e.g. preserving precision de-
vices, food, pets, plants, and art objects). Such usage could damage the items.
Cleaning and maintenance
• Do not touch the metal parts of the unit when removing the filter. Injuries can occur when han-
dling sharp metal edges.
• Do not use water to clean inside the air conditioner. Exposure to water can destroy the insula-
tion, leading to possible electric shock.
• When cleaning the unit, first make sure that the power and breaker are turned off. The fan ro-
tates at a very high speed during operation. There is a possibility of injury if the unit’s power is
accidentally triggered on while cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
BEFORE USE
8
PRODUCT INTRODUCTION
ENGLISH
Name and function of parts
1 Indoor unit
2 Outdoor unit
3 Remote controller
4 Inlet air
5 Discharge air
6 Refrigerant piping, connection electric wire
7 Drain pipe
8 Ground wire
Wire to ground outdoor unit to prevent
electrical shocks.
What to do before operation
If your installation has a customized control
system, ask your LG dealer for the operation
that corresponds to your system.
1 Unit with remote controller
2 Unit without remote controller
(when used as simultaneous operation)
PRODUCT INTRODUCTION
1
3
4
6
5
4
7
2
8
Multi system
Pair system or Simultaneous operation system
A
B
1
2
1
1
Operation Indication Lamps
O
On/Off
: Lights up during the system operation.
Filter Sign
: Lights up after 2400 hours from the time of first operating unit.
Timer
: Lights up during Timer operation.
Defrost Mode
: Lights up during Defrost Mode or Hot Start operation.
(Heat pump type)
Forced operation
: To operate the unit when the remote control can't be used for
any reason.
PRODUCT INTRODUCTION
9
ENGLISH
Wireless Remote Controller
Cooling Mode
Auto Mode or Auto Changeover
Dehumidification mode
Heating Mode
Fan Mode
Cooling Model( ), Heat Pump Model( )
Operation Mode
2
1
5
9
7
10
12
13
14
15
17
16
11
3
4
6
8
VANE ANGLE Button
Used to set each vane angle.
FUNCTION SETTING Button
Used to set or clear Auto Clean, Smart Clean,
Electric heater or Individual vane angle control.
ON/OFF Button
Used to turn on/off the unit.
JET COOL Button
Speed cooling operates super high fan speed.
LEFT/RIGHT AIRFLOW Button (OPTIONAL)
Used to set the desired left/right(horizontal)
airflow direction.
UP/DOWN AIRFLOW Button
Used to stop or start louver movement and set
the desired up/down airflow direction.
ON TIMER Button
Used to set the time of starting operation.
SLEEP TIMER Button
Used to set the time of sleeping operation.
SET / CLEAR Button
Used to set/clear the timer.
Used to set the current time(if it input for 3sec.)
PLASMA Button (OPTIONAL)
Used to start or stop the plasma-purification
function.
ROOM TEMPERATURE SETTING Button
Used to select the room temperature.
OPERATION MODE SELECTION Button
Used to select the operation mode.
INDOOR FAN SPEED SELECTION Button
Used to select fan speed in four steps low,
medium, high and chaos.
ROOM TEMPERATURE CHECKING Button
Used to check the room temperature.
OFF TIMER Button
Used to set the time of stopping operation.
TIMER SETTING(Up/Down)/LIGHT Button
Used to set the timer.
Used to adjust the brightness.(if it is not time
adjust mode)
RESET Button
Used to reset the remote controller.
10
PRODUCT INTRODUCTION
ENGLISH
NOTE
!
For more details refer to the Wireless
Remote Control Accessory manual.
The actual product can be different
from above contents depending upon
model type.
CAUTION
• Aim at the signal receiver on the wired
remote controller so as to operate.
• The remote control signal can be re-
ceived at a distance of up to about 7m.
• Be sure that there are no obstructions be-
tween the remote controller and the sig-
nal receptor.
• Do not drop or throw the remote con-
troller.
• Do not place the remote controller in a lo-
cation exposed to direct sunlight, or near
the heating unit, or any other heat
source.
• Block a strong light over the signal recep-
tor with a curtain or etc. so as to prevent
the abnormal operation. (ex:electronic
quick start, ELBA, inverter type fluores-
cent lamp)
!
13
ENGLISH
INSTALLATION INSTRUCTIONS
Mode Override
This Function is only for Non-Auto Changeover H/P model.
Ceiling Height Selection
Our products provide variety of air volumes and capacities according to the selection of ceil-
ing heights.
Cooling/Heating performance is enhanced with relation to ceiling height.
- The highest/cooling heating performance and efficiency are provide at super high.
(Some noise may be generated according to the level height setting.)
Group Control
This function is only for group control. Please don’t set this function in case of non-group
control.
After setting Group Control of the product, turn off the power then turn it back on after 1
minute.
Auxiliary heater
This function is only applied to models with Auxiliary Heater function being activated.
Installer Setting - Installer Setting Code Table
Installer Setting Code Table
No. Function Function Code Setting Value Remote Controller LCD
0 Mode Override
0
0 : Set to Master
1 : Set to Slave
1
Ceiling Height
Selection
1
1 : Standard
2 : Low
3 : High
4 : Super High
2
Group Control
2
0 : Set to Master
1 : Set to Slave
2 : Check Master/Slave
Auxiliary heater
2
3 : Set to Auxiliary heater
4 : Cancel Auxiliary heater
5 :
Check Auxiliary heater Installation
Code Feel
2 Cold
1 Slightly cool
0 Neutral
-1 Slightly warm
-2 Warm
Please select the code
depend on your feeling.
SET/CLEAR
SET/CLEAR
Timer Sleep
Timer ON
Timer OFF
24
MAINTENANCE AND SERVICE
ENGLISH
Grille, Case and Remote Control
- Turn the system off before cleanining, To
clean, wipe with a soft, dry cloth. Do not use
bleach or abrasives.
The air filters behind the front grille should be
checked and cleaned once every 2 weeks or
more often if neccessary.
- Never use any of the followings:
Water hotter than 40°C.
Could cause deformation and or discol-
oration.
Volatile substances.
Could damage the surfaces of the air condi-
tioner.
- Remove the Air filters.
Take hold of the tab and pull slightly forward
to remove the filter.
- Clean dirt from the air filter using a vacuum
cleaner or washing with water.
If dirt is conspicuous, wash with a neutral
detergent in lukewarm water.
If hot water (40°C or more) is used, it may
be deformed.
- After washing with water, dry well in the
shade.
Do not expose the air filter to direct sunlight
or heat from a fire when drying it.
- Install the air filter.
NOTE
!
Supply power must be disconnected be-
fore cleaning the indoor unit.
CAUTION
When the air filter is to be removed, do
not touch the metal parts of the indoor
unit.
It may cause an injury.
!
Air Filters
B
e
n
z
e
n
e
S
C
O
U
R
I
N
C
L
B
A
R
G
E
S
I
N
N
E
R
Horizontal louver
Vertical louver
Air outlet vent
Air inlet vent
(Inlet grille)
Air filters
(Behind inlet grille)
MAINTENANCE AND SERVICE
MAINTENANCE AND SERVICE
25
ENGLISH
Do not overcool the room.
This is not good for the health
and wastes electricity.
Keep blinds or curtains closed.
Do not let direct sunshine
enter the room when the air
conditioner is in operation.
Keep the room temperature
uniform.
Adjust the vertical and hori-
zontal airflow direction to en-
sure a uniform temperature in
the room.
Make sure that the doors
and windows are shut tight.
Avoid opening doors and win-
dows as much as possible to
keep the cool air in the room.
Clean the air filter regularly.
Blockages in the air filter re-
duce the airflow and lower
cooling and dehumidifying ef-
fects. Clean at least once
every two weeks.
Ventilate the room occasion-
ally.
Since windows are kept
closed, it is a good idea to
open them and ventilate the
room now and then.
When the air conditioner is not
going....
When air conditioner is not going to
be used for a long time.
- Operate the air conditioner at the following
settings for 2 to 3 hours.
Type of operation: Fan operation mode.
(Refer to page “Fan Mode”.)
This will dry out the internal mechanisms.
- Turn off the breaker.
- Remove the batteries from the Remote Con-
troller.
Helpful information
The air filters and your electiric bill.
If the air filters become clogged with dust, the
cooling capacity will drop, and 6% of the elec-
tricity used to operate the air conditioner will
be wasted.
When the air conditioner is to be
used again.
- Clean the air filter and install it in the indoor
unit. (Refer to page “MAINTENANCE AND
SERVICE”.)
- Check that the air inlet and outlet of the in-
door/outdoor unit are not blocked.
- Check that the ground wire is connected cor-
rectly. It may be connect to the indoor unit
side.
CAUTION
Turn off the breaker when the air condi-
tioner is not going to be used for a long
time.
Dirt may collect and may cause a fire.
!
Operation Tips!
26
MAINTENANCE AND SERVICE
ENGLISH
Call the service immediately in the following situations
- Anything abnormal such as burning smell, loud noise etc. happen. Stop the unit and turn the
breaker off. Never try to repair by yourself or restart the system in such cases.
- Main power cord is too hot or damaged.
- Error code is generated by self diagnosis.
- Water leaks from indoor unit even if the humidity is low.
- Any switch, breaker (safety, earth) or fuse fails to work properly
User must carry routine checkup & cleaning to avoid unit’s poor performance.
In case of special situation, the job must be carried out by service person only.
The air conditioner
does not operate.
- Have you made a
mistake in timer op-
eration?
- Has the fuse blown
or has the circuit
breaker been
tripped?
The room has a pecu-
liar odor.
- Check that this is not
a damp smell ex-
uded by the walls,
carpet, furniture or
cloth items in the
room.
It seems that conden-
sation is leaking from
the air conditioner.
- Condensation occurs
when the airflow
from the air condi-
tioner cools the
warm room air.
Air conditioner does
not operate for about
3 minutes when
restart.
- This is the protector
of the mechanism.
- Wait about three
minutes and opera-
tion will begin.
Does not cool or heat
effectively.
- Is the air filter dirty?
See air filter cleaning
instructions.
- The room may have
been very hot when
the room air condi-
tioner was first
turned on. Allow
time for it to cool
down.
- Has the temperature
been set incorrectly?
- Are the indoor unit's
air inlet or outlet
vents obstructed?
The air conditioner op-
eration is noisy.
- For a noise that
sounds like water
flowing.
* This is the sound
of freon flowing in-
side the air condi-
tioner unit.
- For a noise that
sounds like the com-
pressed air releasing
into atmosphere.
-
This is the sound of
the dehumidifying
water being
processed inside the
air conditioning unit.
Crack sound is heard.
- This sound is gener-
ated by the expan-
sion/ constriction of
the front panel, etc.
due to changes of
temperature.
Remote control dis-
play is faint, or no dis-
play at all.
- Are the batteries de-
pleted?
- Are the batteries in-
serted in the oppo-
site (+) and (-)
directions?
Filter sign lamp (LED)
is ON.
- Cleaning the filter,
press the Timer but-
ton and button of
wired remote con-
troller at the same
time for 3 sec.
Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the malfunction persist,
please contact your dealer.
JET COOL
SET/CLEAR
SET/CLEAR.
6
ENGLISH
MUNDARIJA JADVALI
MUNDARIJA
2 ENERGIYA TEJASH
BO’YICHA
MASLAHATLAR
RALAMTASROK ADIQAH
7 FOYDALANISH OLDIDAN
3 TEXNIKA HAVFSIZLIGI
kilragroyyat aghsI 7
hsinaladyoF 7
hsitasrok tamzih av hsalazoT 7
8 USKUNA HAQIDA
UMUMIY MA’LUMOTLAR
8 Nomlar va qism vazifalari
8 Foydalanish oldidagi vazifalar
8 Boshqaruvning ko’rsatkich chiroqlari
9 Simsiz boshqaruv pulti
11 FOYDALANISH
UCHUN
QO’LLANMA
11 Batareyalarni almashtirish
11 Simsiz pultni ishlatish ko'rsatmalar
12 O’RNATISH UCHUN
KO’RSATMALAR
12 Vazifalarni belgilash Dastur vazifalariga
kirish
gninraltamziH hsaligleb inralafizaV31
vazifalari haqida jadval
yizakraM hsaligleb inralafizaV41
boshqaruv uchun manzilni kiritish
yizakraM hsaligleb inralafizaV41
inliznam naglitirik nuhcu vuraqhsob
tekshirish
15 Foydalanuvchi qo’llanmasi
15 Sovutish Standart operatsiya
15 Sovutish Kuchli sovutish
16 Isitish tartibi
17 Ishlash dasturi vazifalarining avtomatik
tarzda yonishi.
17 Ishlash dasturi vazifalarining avtomatik
adnaghsamlairalbitrat .ihsinoy adzrat
haroratni belgilash
18 Avtomatik dastur
19 Quritish dasturi
20 Ventilyatsiya dasturi
21 Vazifa berish dasturi /Honadagi haroratni
aks etishi
22 Havo oqimi yo’nalishini boshqarish
22 Havo haroratini Tselsiy / Farengeyt
darajasi
23 Taymer
24 TEXNIK HIZMAT
KO’RSATISH
25 Konditsionerning ishlash jarayonida
foydalanish bo’yicha maslahatlar
26 Nosozliklarni bartaraf etish bo’yicha
maslahatlar. Vaqt va pulni tejash!
.
27 Quyidagi holatlarda darhol hizmat
markazigaqo’ng’iroq qiling.
O'ZBEK TILI
10
USKUNA HAQIDA UMUMIY MA’LUMOTLAR
DIQQ AT
!
!
OGOHLANTIRISH
Ish boshlash uchun pultni qabul qiluvchi
signaliga qaratish lozim.
Pult signali 7 metr masofagacha qabul
qilinishi mumkin.
Pult va uskuna orasida hech qanday
to’siq yo’qligiga ishonch hosil qiling.
MB pultini otmang va tushirib yubormang.
MB pultini to’g’ridan to’g’ri tushadigan
quyosh nurlari ostiga, isituvchi moslama va
boshqa issiqlik manbaylari yonida
qoldirmang.
Tasodifiy ishlab ketish yoki noto’g’ri
buyurtma oldini olish maqsadida
moslamani signal to’g’risida qoldirmang.
Masala
n: Ele kt
ron tez yoqish.Inventor
turidagi ELBA chirog'i.
Qo’shimcha ma’lumot olish uchun MB
simsiz pultidan foydalanish bo’yicha
qo’llanmasiga qarang.
Modeliga qarab o’ziga hos vazifalarida farq
bo’lishi mumkin.
O'ZBEK TILI
Quritish dasturi
1 ON/OFF (Ochirish/Yoqish) tugmasini bosing.
Tovushli signal eshitiladi.
2 Mode (Dastur) tugmasini bosing va
“Degidratsiya” dasturini tanlang.
3 Ventilyatsiya aylanish tezligini belgilang.
Ventilyator aylanish tezligini quyidagi tartibda
amalga oshirish mumkin. Tugmani har
bosganingizda ventilyatorning aylanish tezligi
o’zgaradi.
FAN SPEED (Ventilyatorning tez tez
aylanishi)
Tanlov tugmasi orqali Quritish dasturini
tanlasangiz ichki qism havoni quritish
jarayonini boshlaydi u avtomatik tarzda
hona harorati asosida hona harorati va
oqimini belgilaydi. Bunday holatda
belgilangan harorat boshqaruv pulti
displeyda namoyon bo’lmaydi (haroratni
almashtirish imkoni yo’q)
Quritish dasturining ishlash jarayonida
havo oqimi hona haroratiga mos
ravishda
belgilanadi, shuningdek hattoki
zah honada ham sog’lom va qulay
sharoit hukmronlik qiladi.
O'ZBEK TILI
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79

LG UV48W.NL2R0 Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI