ELEMENT BRACKET CONVERSION
010
Page 1 of 1
• Element bracket kit# 506863 positions heating elements in
12x20 pan-style warmers.
• This kit replaces obsolete clips p/n 50397 and 50467.
PREPARATION
• Disconnect unit from electric power.
• Disassemble element pan from warmer.
• Remove and discard all existing element clips.
• On end panel away from element terminals, mark a line
1/2” (12.7mm) from top edge of panel. Locate and mark the
center of the panel.
• On end panel nearest element terminals, mark a line
5/32” (4mm) above centerline of element “keyhole” cutouts.
Locate and mark the center of the panel.
• Bend retaining tabs on brackets no more than 45º.
Each bracket has 2 tabs.
ASSEMBLY
• Attach the “U” shaped bracket to end panel away from element
terminals:
a. Center bracket on panel with the two bracket mounting
holes aligned with the 1/2” line.
b. Mark the location of the bracket mounting holes Drill a
1/16” diameter hole at each location.
c. Attach bracket to INSIDE of pan with provided drill-point
screws.
• Attach “I” shaped bracket to end panel nearest element
terminals:
a. Drill a 1/16” diameter hole at the at the intersection of the
centerline and the 5/32” line.
b. Attach bracket to INSIDE of pan with provided drill-point
screws.
• Install element on bracket.
• Bend retaining tabs to capture element.
NOTE:
Brackets locate element the proper distance from bottom of
pan, but allow element to expand and contract during heating
cycle. Be sure element is free to move laterally in bracket.
• Reassemble warmer and return to service.
CAUTION:
FIRE HAZARD
Disconnect from electric power
before servicing appliance.
CAUTION:
BURN HAZARD
Allow appliance to cool completely
before servicing.
Bend retaining tabs
no more than 45º.
45º
CENTERED
CENTERED
“I” SHAPED BRACKET
(FRONT)
“U” SHAPED BRACKET
(REAR)