Table of Contents
1.0Aboutyoursecuritysystem 5
1.1Firedetection 5
1.2Carbonmonoxidedetection 5
1.3Testingyoursystem 5
1.4Monitoring 6
1.5Cleaningandmaintenance 6
2.0Generalsystemoperation 7
2.1Integratedkeypad 7
2.2Panelindicators 7
2.3Integratedkeypadquickreference 11
2.4WirelessLCDkeypad 12
2.4.1Wirelesskeypadsymbols 12
2.4.2Wirelesskeypadquickreference 12
2.5Importantnotice 14
2.5.1Powersavemode 14
2.6Systemmodels 14
2.7Languageselection 14
3.0Arming/Settingthesystem 16
3.1Stayarming/setting 16
3.1.1Stayarming/settingontheintegratedkeypad 16
3.1.2Stayarming/settingonthewirelesskeypad 16
3.2Silentexitdelay 17
3.3No-entryarming/setting 17
3.4Awayarming/setting 17
3.4.1Awayarming/settingontheintegratedkeypad 17
3.4.2Awayarming/settingonthewirelesskeypad 18
3.5Quickarming/set 18
3.6Quickexit 18
3.6.1Quickexitonthewirelesskeypad 19
3.7Arming/Settingerrorsandexitfaults 19
3.7.1Arming/Settingerror 19
3.8Audibleexitfault 19
- 2 -
Table of Contents
3.9Alarmcancelwindow 20
3.10Bypasszones 20
3.11Forcearming/setting 20
3.12Troubles/openzonescancelarming/setting 20
4.0Disarming/unsettingthesystem 21
4.1Disarming/unsettingontheintegratedkeypad 21
4.2Disarming/unsettingonthewirelesskeypad 21
4.3Disarming/unsettingerror 21
5.0Usingwirelesskeys 22
6.0Useraccesscodes 23
6.1Accesscodes 23
6.1.1Supervisor/administrator 23
6.1.2Basic/standarduser 24
7.0Testingandresettingthesystem 25
7.1Fullsystemwalktest 25
7.2Engineer'sreset(WS912models) 26
7.3Remote(anti-code)reset(WS912models) 26
8.0Additionalfeatures 27
8.1Systemlockoutduetoinvalidattempts 27
8.2Burglaryverification 27
8.3Swingershutdown 27
8.4Firealarmverification 27
8.5User-enabledinstalleraccess 27
8.6Firmwareupdate 27
9.0Managingpartitions 28
9.1Partitions 28
9.1.1Singlepartitionoperation 28
9.1.2LoaninganLCDkeypadtoanotherpartition 28
9.2FireandCOzonetypes 29
10.0Emergencykeys 30
10.1Emergencykeysontheintegratedkeypad 30
10.2Emergencykeysonthewirelesskeypad 30
10.3Whenalarmsounds 30
- 3 -
Table of Contents
10.3.1Firealarmpulsedsiren(temporal3) 31
10.3.2Carbonmonoxide(CO)alarm 31
10.3.3Intrusion(burglary)alarm 31
11.0Viewingtroubles 33
12.0UsingZ-WaveDevices 36
12.1Z-WaveAllianceCertification 36
12.2AddingorRemovingaController 36
12.3ReplicatingaController 36
12.4ControllerLearnMode 36
12.5ChangingthePrimaryController 36
12.6AddingaDevice 37
12.6.1EditingorRemovingaDevice 37
12.7DeviceInteroperability 37
12.8Z-WaveAssociationGroups 37
12.9RespondingtotheBasicCommand 37
12.10Z-WaveReset 38
13.0Safetyinstructions 39
14.0Locatingdetectorsandescapeplan 40
14.1Smokedetectors 40
14.2Fireescapeplanning 41
14.3Carbonmonoxidedetectors 42
15.0Regulatoryagencystatements 43
16.0UKComplianceStatement 45
17.0EULA 46
18.0Referencesheets 49
18.1Systeminformation 49
18.2Servicecontactinformation 49
- 4 -
Chapter 1.0 About your security system
1.0 About your security system
Readthismanualcarefullyandhaveyourinstallerinstructyouontheoperationandfeaturesofyour
system.Allusersmustbefullyinstructedinitsuse.FillouttheSystemInformationpagewithall
ofyourzoneinformationandaccesscodes,andstorethismanualinasafeplaceforfutureref-
erence.
NOTE:Theiotegasecuritysystemincludesspecificfalsealarmreductionfeaturesandisclassified
inaccordancewithANSI/SIACP-01-2014ControlPanelStandard-FeaturesforFalseAlarm
Reduction.Consultyourinstallerforfurtherinformationregardingthefalsealarmreductionfea-
turesbuiltintoyoursystem,asthismanualdoesnotcoverallfeatures.
1.1 Fire detection
Ifyourinstallerenablesthisfeature,thissystemcanmonitorfiredetectiondevices,suchassmoke
detectors,andprovideawarningifafireconditionisdetected.Goodfiredetectiondependsonhav-
inganadequatenumberofdetectorsplacedinappropriatelocations.Thisequipmentmustbe
installedinaccordancewithNFPA72(N.F.P.A.,BatterymarchPark,QuinceyMA02269).Care-
fullyreviewtheFireEscapePlanningsectioninthismanual.
1.2 Carbon monoxide detection
Ifyourinstallerenablesthisfeature,thissystemcanmonitorcarbonmonoxidedetectorsand
provideawarningifcarbonmonoxideisdetected.RefertotheFireescapeplanningandCarbon
monoxidedetectorssectionsformoreinformation.
1.3 Testing your system
Thesystemtestactivatesa4-secondcheckofthesystemstatusLEDs,keypadLEDs,buzzer,and
siren.Itisapartition-basedtestandmustbedonewhenthesystemisdisarmed/unset.
Youcanperformasystemtestfromthewebportal.
Thefollowingeventshappenduringasystemtest:
lAllsystemstatusLEDsflashfor4seconds.
lAsystemtesttransmitstothemonitoringstation.
lThesystemchecksthebackupbatterylevel.
lThekeypadLEDsilluminatefor4seconds.
lThesystembuzzersoundsfor4seconds,orthepartitionbuzzerandsirensoundfor2
secondseachinseries.
Testyoursystemweeklytoensurethatitfunctionsasintended.Informyourmonitoringstation
whenyoubeginandendsystemtesting.
Aqualifiedservicetechnicianmusttesthouseholdfirealarmsystemsatleastevery3yearsin
accordancewithNFPA72.Itisyourresponsibilitytotestthesystemweekly,excludingsmoke
detectors.
Ifthesystemfailstofunctionproperly,callyourinstallationcompanyforservice.
- 5 -
Chapter 1.0 About your security system
1.4 Monitoring
Thissystemcantransmitalarms,troublesandemergencyinformation.Ifyouinitiateanalarmby
mistake,immediatelycallthemonitoringstationtopreventanunnecessaryresponse.
Notes:
lYourinstallermustenablethemonitoringfunctionbeforeitisfunctional.
lConsultwithyourinstallertodetermineifyoursystemisconfiguredwithacommunicator
delay.Acommunicatordelaypreventsareporttothemonitoringstationifthecontrol
panelisdisarmed/unsetwithin30-45secondsafteranintrusionalarmistriggered.Note
thatfire-typealarmsarenormallyreportedwithoutadelay.
lIfenabledandconfigured,youcancelanalarmafterthecommunicationdelaywiththe
alarmcancelwindow.RefertotheAlarmcancelwindowsectionformoreinformation.
lContactyourinstallertoverifythatyoursystemiscompatiblewiththeCentralStation
Receiverformatatyearlyintervals.
1.5 Cleaning and maintenance
Keepyouriotegainoptimalconditionbyfollowingallinstructionsincludedwithinthismanual
and/ormarkedontheproduct.Theend-userand/orinstallerareresponsiblefordisposingofused
batteriesaccordingtothewasterecoveryandrecyclingregulationsapplicabletothelocalmarket.
lCleantheunitbylightlydustingwithaslightlymoistenedcloth.
lDonotwipethefrontcoverwithalcohol.
lDonotusewateroranyotherliquid.
lDonotuseabrasives,thinners,solventsoraerosolcleaners(spraypolish)thatmayenter
throughholesandcausedamage.
lReplacethestandbybatteryevery3-5years.
Forothersystemdevicesorsensors,consultthemanufacturer’sliteraturefortestingandmain-
tenanceinstructions.
- 6 -
Chapter 2.0 General system operation
2.0 General system operation
Yoursecuritysystemincludesanintegratedalarmcontrolpanelandvarioussensorsanddetectors.
Thesystemisself-contained;thecontrolpanel,integratedkeypad,andstandbybatteryareall
housedwithintheunit.
Thesecuritysystemhasseveralzonesofareaprotection.Azoneisasensorordetectorthatcom-
municateswiththepanel.Asensorinalarmisindicatedontheintegratedkeypad,wirelesskeypad,
touchscreenkeypad,andbymessagesonthemobilephoneuserapplication.
2.1 Integrated keypad
Theiotegasystemincludesacapacitivetouchintegratedkeypadwith16keys:numbers0thru9,*,
#,Fire,Auxiliary,Panicemergencykeys,andshift(uparrow).
Duringpowerup,thenumberkeysilluminateinsequenceseveraltimes.Innormaloperation,the
keypadremainsoffwhennotinuse.Whenyouwaveyourhandincloseproximitytothekeypad,the
numberkeysilluminate.
1 2 3
4 5 6
7 8
0
*#
9
WS912-28 WS90X-XX
Notes:
lTheemergencykeysdonotilluminateunlessyoutaptheshiftkey.SeetheEmergency
Keyssectionformoreinformation.
lYoucanonlyusethekeypadforarming/setting,disarming/unsetting,andtheemergency
keys.Thesamefunctionsareavailablewhenswitchingbetweenpartitions.
2.2 Panel indicators
TheiotegasystemincludessevenLEDstatusindicators:
lFoursingle-colorLEDs
lThreemulti-colorLEDs(red,green,amber)
- 7 -
Chapter 2.0 General system operation
7654 123
89
WS912-28 WS90X-XX
Item Description
1 PowerLED
2 ReadytoArm/SetLED
3 Armed/SetLED
4 TroubleLED
5 WiFiSignalStrengthLED
6 CellularSignalStrengthLED
7 RemoteConnectionLED
8 Siren
9 Microphone
Power
Status LED Indication Description
 ON(green) ACpowerisconnectedtothesystem.
Flashing(green) SystemTest
AllstatusLEDsflashatthesametime.
OFF ThereisnoACpowertothesystem.
- 8 -
Chapter 2.0 General system operation
Ready to Arm/Set
Status LED Indication Description
ON(green) Thepartitionisreadytoarm/set.Therearenofire
orCOalarmconditions.
Flashing(green) SystemTest
AllstatusLEDsflashatthesametime.
ForceArm
Thesysteisreadytoarm/set,butForceArm-cap-
ablezonesareopen.
 WalkTest
Ready,Trouble,andArm/SetLEDsflashatthe
sametime.
 Thesystemisreadytoarm/set,butforcearmzones
areopen.
OFF Thesystemisnotreadytoarm/set.
AfireorCOalarmconditionispresent.
Armed/Set
Status LED Indication Description
ON(red) Thepartitionisarmed/set.
Flashing(red) ThepartitionisinAlarm.
NOTE:Silentalarmsorpanicsdonotflashthe
AlarmLED.
SystemTest
AllstatusLEDsflashatthesametime.
WalkTest
Ready,Trouble,andArm/SetLEDsflashatthe
sametime.
OFF Thepartitionisdisarmed/unset.
- 9 -
Chapter 2.0 General system operation
Trouble
Status LED Indication Description
ON(amber) Asystemtroubleispresent.
Flashing(amber)
[cadenceof500ms
On/500msOFF]
[*][2]TheTroublemenuisaccessed.
Flashing(amber)
[cadenceof250ms
ON/250msOFF/250ms
ON/750msOFF]
Thesystemisinthesecond-levelsubmenu.
Flashing(amber)
[cadenceof250ms
ON/250msOFF/250ms
ON/250msOFF/250ms
ON/750msOFF]
Thesystemisinthethird-levelsubmenu.
Flashing(amber) SystemTest
AllstatusLEDsflashatthesametime.
 WalkTest
Ready,Trouble,andArm/SetLEDsflashatthe
sametime.
OFF Systemtroublesarecleared.
WiFi Signal Strength
Status LED Indication Description
ON(green) Theradioisactivewithastrongsignalconnection.
ON(amber) Theradioisactivewithaweaksignalconnection.
ON(red) Thereisnosignal.
Flashing(green). TheradioisactiveinWiFiprotectedsetup(WPS)
modeforaccesspoint(AP)mode.
Flashing(amber) Z-Waveradioisactiveinlearnpairmode
Flashing(amber) SystemTest
AllstatusLEDsflashatthesametime.
OFF Theradioisinactiveornotconnectedtothenet-
work.
- 10 -
Chapter 2.0 General system operation
Cellular Signal Strength
Status LED Indication Description
ON(green) Cellularisactivewithastrongsignalconnection.
ON(amber) Cellularisactivewithaweaksignalconnection.
ON(red) Acommunicatorisinstalledbutthereisnosignalor
connection
Flashing(amber) SystemTest
AllstatusLEDsflashatthesametime.
OFF Acommunicatorisnotinstalledornotconfigured.
Remote Connection Status
Status LED Indication Description
ON(green) Thelinkisactivewithaserver.
Flashing(red) Thelinkactivatesbutfailstocommunicatewiththe
server.
Flashing(amber) SystemTest
AllstatusLEDsflashatthesametime.
OFF Thelinkisnotyetactivewithanyserver.
NOTE:IftheRemoteConnectionstatusLEDflashesred,theservermaybeundergoingmain-
tenanceorexperiencingtechnicaldifficulties.Restartingthepanelmayremedytheissue.Ifthe
problempersists,contactyourinstaller.
2.3 Integrated keypad quick reference
Usethefollowingtableforquickreferenceoftheintegratedkeypadoptions:
Action Enter
Arming/Setting and Disarming/ Unsetting
Awayarm/set [2](holdfor2seconds)+[AccessCode]ifthe[*]key
flashes.
Stayarm/set [1](holdfor2seconds)+[AccessCode]ifthe[*]key
flashes.
Disarm/Unset [AccessCode]
Abortarming/settingsequence [AccessCode]
System troubles
Silencetroubles [Anykey]or[*][2]+[Accesscode1]+[#]
Viewtroubles [*][2]+[Accesscode1]+[Troublecode]
Enable/DisableChime [*]+[4]+[AccessCode]ifthe[*]keyflashes.
1ForULlistedinstallations,youmustenteryouraccesscodetosilencetroublebeepsandviewsys-
temtroubles.
- 11 -
Chapter 2.0 General system operation
2.4 Wireless LCD keypad
Theiotegasystemsupportsthefollowingkeypadmodel:
WS9LCDWFx
x=4(433MHz),8(868MHz),9(912-919MHz)
WirelessAlphanumericLCDkeypad
2.4.1 Wireless keypad symbols
Status
LED Indication Description
Readyto
arm/set
ON(green) Thepartitionisreadytoarm/set.NofireorCO
alarmsarepresent.
Ifflashing,aForceArmtypezoneisopen.
Armed/set ON/flashing(red) Thepartitionisarmed/set.
Trouble ON(yellow) Asystemtroubleispresent.
Flashing Keypadlowbattery.
Power ON(green) ACpowerisconnectedtothekeypad.
2.4.2 Wireless keypad quick reference
Whenusingthewirelesskeypad,theiotegasystemusesshortcutkeystoaccessoptionsorfeatures.
Additionally,itusesamenu-basednavigationsystem.Usethescrollkeystonavigatethroughthelist
ofoptionscontainedwithinthecurrentmenu.
NOTE:Yourinstallermustenableandconfiguresomefeatures.
Action Press
Arming/Setting and Disarming/Unsetting
AwayArm/Set for2seconds+[AccessCode1]
StayArm/Set for2seconds+[AccessCode1]
Disarm/Unset [AccessCode]
Quickexit for2seconds
Abortarming/settingsequence [AccessCode]
Bypassing - All bypass commands begin with [*][1] + [Access Code1]
Bypassindividualzones [3-digitzone#]
Common functions
TurnchimeON/OFF for2seconds(+[AccessCode]ifconfiguredby
yourinstaller)
Changebrightness [*][6]+[Mastercode]+
Changecontrast [*][6]+[MasterCode]+
- 12 -
Chapter 2.0 General system operation
Action Press
Viewtroubles [*][2]+[Accesscode
2
]+
Viewalarms [*][3]+
Buzzervolume [*][6]+[MasterCode]+
Languageselection [*][6]+[MasterCode]+
WalkTest [*][6]+[MasterCode]+
SystemService [*][6]+[UserCode]+[5]
1Ifconfiguredbyyourinstaller
2ForULlistedinstallations,youmustenteryouraccesscodetosilencetroublebeepsandviewsys-
temtroubles.
- 13 -
Chapter 2.0 General system operation
2.5 Important notice
Asecuritysystemcannotpreventemergencies.Itisonlyintendedtoalertyouandyourmonitoring
station,ifapplicable,toanemergencysituation.Securitysystemsaregenerallyveryreliable,but
theymaynotworkunderallconditionsandtheyarenotasubstituteforprudentsecuritypracticesor
lifeandpropertyinsurance.Yoursecuritysystemmustbeinstalledandservicedbyqualifiedsecur-
ityprofessionals.Theseprofessionalscaninstructyouonthelevelofprotectionthathasbeen
providedandonsystemoperations.
2.5.1 Power save mode
WhenthepanelisinPowerSavemode,itissavingbatterylife.Theintegratedkeypadisnotturned
onuntilthereisaspecificreason,suchasahandwaveinfrontofthepanel,orthestartofanentry
delay.
Wheninitiated,thestatusindicatorsstayonfor30secondsbeforeturningoff.Inthismode,the
panelisstillfunctioning,butnothingisvisible.
NOTE:ForULlistedinstallations,theuserappandtouchscreenkeypadfunctionsarenotavailable
inthismode;therefore,youmustusetheintegratedkeypadorthewirelesskeypadtoarm/setordis-
arm/unsetthesystem.
2.6 System models
ThereferencetoWS900inthismanualcoversthefollowingmodels:
WS900-29* Alarmsystemwithtwo-wayaudiosupport,operatingin912-919
MHzband
WS900-19* Alarmsystemwithtwo-wayaudiosupport,operatingin912-919
MHzband
3G7090* 3GCellularAlarmCommunicator
LT7090* VerizonLTEOnlyCellularCommunicator
(*)ThesedevicesareUL/ULClisted.
NOTE:Two-wayaudiosupportwasnotevaluatedbyUL/ULC.
WS912-28 Alarmsystemoperatingin868MHzband
WS901-24EU Alarmsystemoperatingin433MHzband
WS901-14 Alarmsystemoperatingin433MHzband
3G7090-EU 3GCellularAlarmCommunicator
2.7 Language selection
Theiotegasupportsthefollowinglanguages,althoughnotallmaybeavailableonyoursystem:
lEnglish
lFrench
lSpanish
lPortuguese
- 14 -
Chapter 2.0 General system operation
lGerman
lDutch
lSwedish
lFinnish
lNorwegian
lDanish
lPolish
lItalian
lGreek
Availablelanguagescanbeselectedusingthetouchscreenkeypadorthewirelesskeypad.
- 15 -
Chapter 3.0 Arming/Setting the system
3.0 Arming/Setting the system
Youcanarm/setthesystemusingthefollowingoptions:
lIntegratedkeypad
lWirelesskeypad
lTouchscreenkeypad
lUserapp(OperationwiththeuserappwasnotevaluatedbyUL/ULC.)
lWirelesskey(RefertotheUsingwirelesskeyssectionforalistofUL/ULClistedcom-
patiblewirelesskeys.)
3.1 Stay arming/setting
Stayarming/settingprotectsonlytheperimeterofthepremisespermittingmovementinside.
NOTE:Toarm/setthesysteminStaymode,yourinstallermustenrollandconfigureatleastone
zoneasanInteriorStay/AwayoraDelayStay/Awaytypeofzone.
3.1.1 Stay arming/setting on the integrated keypad
1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindic-
atorison.
2. Enteryouraccesscodeanddonotleavethepremises.Thesystemautomaticallyignores
bypassedzonesandinitiatestheexitdelaycountdown.
Tocancelthearming/settingsequence,enteryouraccesscode.
Whenexitdelayisactive,theArmed/SetandReadyindicatorsturnonandthekeypadbeepsonce
persecond.Whentheexitdelayexpires,thesystemisarmed/setandtheReadyindicatorturnsoff
andtheArmed/Setindicatorstayson.
ForEN,whenexitdelayisactive,theReadyindicatorstaysonandthekeypadbeepsonceper
second.Whentheexitdelayexpires,thesystemisarmed/set,theReadyindicatorturnsoff,andthe
Armed/setindicatorturnson(ENonly).
NOTE:ForSIACP-01listedpanels,theStayarming/settingexitdelaywillbetwiceaslongasthe
Awayarming/settingexitdelay.
IfyoursystemisinstalledinaccordancewithSIACP-01StandardforFalseAlarmReduction,the
securitysystemarms/setsintheStaymodeiftheexitdelaytimeexpiresandtherewasnoexit.
Ifyouarm/setthesystemremotelywithoutexitdelay,thesecuritysystemarms/setsinAwaymode
only.
3.1.2 Stay arming/setting on the wireless keypad
Staymodepartiallyactivatesyouralarmsystembyarming/settingallperimetersensorsand
bypassingallinteriorsensors.
Toarm/setthesysteminStaymode,completethefollowingsteps:
1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindic-
atorison.
2. Enteryouraccesscode.
OR
- 16 -
Chapter 3.0 Arming/Setting the system
PressandholdtheStayfunctionkeyfor2secondsandenteryouraccesscode,ifrequired.
Ifzoneshavebeenbypassed,awarningappears.
Aftersuccessfullyinitiatingthearming/settingsequence,thefollowingeventsoccur:
lArmed/Setindicatorturnson.
lReadyindicatorremainson.
lExitDelaytimerbeginscountingdown.
Whentheexitdelaytimerexpires,arming/settingthesystem,thefollowingeventsoccur:
lReadyindicatorturnsoff.
lArmed/Setindicatorremainson.
lBypassorsystemindicatoractivates.
ForEN,Aftersuccessfullyinitiatingthearming/settingsequence,theReadyindicatorremainson
andtheexitdelaytimerbeginscountingdown.
Whentheexitdelaytimerexpires,arming/settingthesystem,thefollowingeventsoccur:
lReadyindicatorturnsoff.
lArmed/Setindicatorturnson.
lBypassorsystemindicatoractivates.
Tocancelthearming/settingsequence,enteryouraccesscode.
3.2 Silent exit delay
Ifthesystemisarmed/setinStaymodeorusingtheNo-entryarming/settingmethod,thekeypad
buzzerissilencedandtheexittimeisdoubledforthatexitperiodonly.(SIACP-01only).
3.3 No-entry arming/setting
No-entryarming/settingsetsthesysteminStayorAwaymodeaftertheexitdelayexpiresand
removestheentrydelay.
Notes:
lAllzonesprogrammedasDelayfunctionthesamewayasinstantzones.
lThisfeatureisonlyavailableonthetouchscreenkeypadanduserapp.
3.4 Away arming/setting
AwayModearms/setstheentiresystem,includingtheperimeterandinteriordevices.
3.4.1 Away arming/setting on the integrated keypad
Toarm/setthesysteminAwaymodeontheintegratedkeypad,completethefollowingsteps:
1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindic-
atorison.
2. Enteryouraccesscode.Exitdelaybegins.Exitthepremisesthroughadoorprogrammed
asentry/exittype.
Tocancelthearming/settingsequence,enteryouraccesscode.
- 17 -
Chapter 3.0 Arming/Setting the system
ForNA,whenexitdelayisactive,theReadyindicatorremainson,theArmed/Setindicatorturns
onandthekeypadbeepsoncepersecond.ForEN,whenexitdelayisactive,theReadyindicator
remainsonandthekeypadbeepsoncepersecond.Dependingonyoursystemconfiguration,you
have____secondstoexitthepremises.Yourinstallercanprogramthistime.
Thekeypadbuzzeremitsarapidpulsatingrateduringthelast10secondsoftheexitdelaytoindic-
atethatthetimeisexpiring.
ForNA,whentheexitdelayexpires,thesystemisarmed/set,theReadyindicatorturnsoffandthe
Armed/setindicatorstayson.
NOTE:InAwayMode,manuallybypassedzonesareloggedandcommunicatedtothemonitoring
station.
IfyoursystemisinstalledinaccordancewithSIACP-01StandardforFalseAlarmReduction,the
followingconditionapplies:Violationandrestoral,followedbyasecondviolationoftheentry/exit
zonebeforetheendoftheexitdelay,restartstheexitdelay.
3.4.2 Away arming/setting on the wireless keypad
Toarm/setthesysteminAwaymode,completethefollowingsteps:
1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindic-
atorison.
2. Enteryouraccesscode.
OR
PressandholdtheAwayModefunctionkeyfor2secondsandenteryouraccesscode,if
required.
Ifzoneshavebeenbypassed,awarningappears
Tocancelthearming/settingsequence,enteryouraccesscode.
NOTE:Yourinstallerconfigurestheexitdelaytime.
3.5 Quick arming/set
Ifenabled,youcanarm/setthesysteminStayorAwaymodewithoutenteringanaccesscodewith
theuserapporthefunctionkeyonthewirelesskeypad.
Ifdisabled,youmustenteryouraccesscodeforallmethodsofarming/setting.
NOTE:Thisfeatureisenabledbydefault.Contactyourinstallertodisablethisfeature.
3.6 Quick exit
Ifenabled,youcanusetheQuickExitfunctiontoavoiddisarming/unsettingandrearming/resetting
thesystemtoexitthepremises.Whenthesystemisarmed/set,thisfunctionallows2minutesto
exit.Whenthedoorisclosedafterexiting,theremainingexittimeiscancelled.
Notes:
lYourinstallermustenableandconfigurethisfeature.
lThisfeatureisnotavailableontheintegratedkeypad.
- 18 -
Chapter 3.0 Arming/Setting the system
3.6.1 Quick exit on the wireless keypad
TousetheQuickExitfunctiononthewirelesskeypad,completethefollowingsteps:
1. Whensystemisarmed/setandtheArmed/Setindicatorison,pressandholdtheQuick
Exitkeyfor2seconds..
2. Exitthepremisesbeforetheexitdelaytimerexpires.Afterexiting,thedelaytimeriscan-
celed.
3.7 Arming/Setting errors and exit faults
Yoursecuritysystemaudiblynotifiesyouofanyerrorswhenyouareattemptingtoarm/setthesys-
temorexitthepremises.
3.7.1 Arming/Setting error
Anerrortone(longbeep)soundsifthesystemisunabletoarm/set.Arming/settingerrorsoccur
underthefollowingconditions:
lTheaccesscodeisincorrect.
lThesystemisnotready,i.e.sensorsareopen.
lAtroubleconditionispresent.
lThesystemrequiresareset.
Ifyouenteravalidaccesscodeandthesystemisstillunabletoarm/set,amessageappearsonthe
keypad.Thefollowingtableliststhepossibleerrorsandactionstoclearthem:
Message Action
Sensor(s)Open(*)toBypass Press[*]toviewandbypass1theopensensors.
SystemTrouble(*)toView Press[*]toviewtroubles,thenpress[99]orscrolltotheTrouble
Acknowledgmentpromptandpress[*]tooverridethetroublecon-
dition.
ResetRequired Contactyourinstallertocheckandresetthesystem.Refertothe
Engineer'sresetsectionformoreinformation.
1Ifconfiguredbyyourinstaller.
Ensureallsensorsaresecureandthesystemisreadytoarm,thentryagain
3.8 Audible exit fault
Toreducefalsealarms,theaudibleexitfaultnotifiesyouofanimproperexitwhenarmingthesys-
tem.Iftheentry/exitdoorisnotsecurelyclosedduringtheprogrammedexitdelay,thesystem
soundsthealarmtoindicateanimproperexit.
Tocorrectanexitfault,completethefollowingsteps:
1. Re-enterthepremises.
2. Enteryouraccesscodetodisarm/unsetthesystembeforetheentrydelaytimerexpires.
- 19 -
Chapter 3.0 Arming/Setting the system
3. Ensureallsensorsaresecureandthesystemisreadytoarm/set.
4. RepeattheAwayarming/settingprocedure.
3.9 Alarm cancel window
Thereisaperiodoftimeinwhichyoucancancelthealarmtransmission.Whentheprogrammed
alarmtransmissiondelayexpires,cancelinganalarmsendsamessagetothemonitoringstation.
Whenthecancellationmessageissuccessfullytransmitted,thesystembeepssixtimes.
NOTE:
lYourinstallermustenableandconfigurethisfeature.
lForCP-01systems,alarmtransmissiondelaymustnotexceed45seconds.
3.10 Bypass zones
Usethezonebypassingfeaturewhenyouneedaccesstoaprotectedareawhilethesystemis
armed/set,orwhenazoneistemporarilyoutofservice,butyouneedtoarm/setthesystem.
Bypassedzonesarenotabletosoundanalarm.Asaresult,bypassingzonesreducesthelevelof
security.Ifyouarebypassingazonebecauseitisnotworking,callaservicetechnicianimme-
diatelytoresolvetheproblemandrestoreyoursystemtoproperworkingorder.
Ensurethatnozonesareunintentionallybypassedwhenarming/settingyoursystem.Zonescannot
bebypassedoncethesystemisarmed/set.Bypassedzones,exceptfor24-hourzones,areauto-
maticallyunbypassedeachtimethesystemisdisarmed/unsetandmustbebypassedagainbeforethe
nextarmin/setting,ifneeded.
Notes:
l24-hourzonescanonlybeunbypassedmanually.
lForULlistedinstallations,zonescanonlybebypassedmanually.
3.11 Force arming/setting
OpenzoneswiththeForceArmattributeenabled,suchasinteriorzones,donotneedtobe
bypassedtoarm/setthesystem.Notethatyoursystemmaybeconfiguredtorequireallopenzones
tobebypassed,andmayalsorequireanaccesscodetodoso.Checkwithyourinstaller.
IfForceArm-typezonesaresecuredwhilethesystemisarmed/set,theyfunctionasanynormal
zone.Thatis,iftheyareopenedwhilethesystemisarmed/set,analarmisgenerated.
TheReadyLEDflasheswhilethesystemisdisarmed/unsettoindicatethepresenceofopen,Force
Arm-typezones.
3.12 Troubles/open zones cancel arming/setting
IfTroubles/OpenZonesCancelArming/settingisdisabled,arming/settingcanproceedwhile
troublesarepresentandzonesareopen.However,thesystemgoesintoalarm/entrydelay(depend-
ingonthetypeofthezone)afterbeingfullyarmed/setiftheopenzonesarenotbypassed.
- 20 -
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

DSC WS912-28 User manual

Category
Security access control systems
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI