DSC WS912-28 User manual

  • Hello! I am an AI chatbot trained to assist you with the DSC WS912-28 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
intrusion
iotega Wireless Security and
Automation System
User Manual
 
WARNING:Thismanualcontainsinformationonlimitationsregardingproductuseandfunctionand
informationonthelimitationsastoliabilityofthemanufacturer.Readtheentiremanualcarefully.
Table of Contents
Table of Contents
1.0Aboutyoursecuritysystem 5
1.1Firedetection 5
1.2Carbonmonoxidedetection 5
1.3Testingyoursystem 5
1.4Monitoring 6
1.5Cleaningandmaintenance 6
2.0Generalsystemoperation 7
2.1Integratedkeypad 7
2.2Panelindicators 7
2.3Integratedkeypadquickreference 11
2.4WirelessLCDkeypad 12
2.4.1Wirelesskeypadsymbols 12
2.4.2Wirelesskeypadquickreference 12
2.5Importantnotice 14
2.5.1Powersavemode 14
2.6Systemmodels 14
2.7Languageselection 14
3.0Arming/Settingthesystem 16
3.1Stayarming/setting 16
3.1.1Stayarming/settingontheintegratedkeypad 16
3.1.2Stayarming/settingonthewirelesskeypad 16
3.2Silentexitdelay 17
3.3No-entryarming/setting 17
3.4Awayarming/setting 17
3.4.1Awayarming/settingontheintegratedkeypad 17
3.4.2Awayarming/settingonthewirelesskeypad 18
3.5Quickarming/set 18
3.6Quickexit 18
3.6.1Quickexitonthewirelesskeypad 19
3.7Arming/Settingerrorsandexitfaults 19
3.7.1Arming/Settingerror 19
3.8Audibleexitfault 19
- 2 -
Table of Contents
3.9Alarmcancelwindow 20
3.10Bypasszones 20
3.11Forcearming/setting 20
3.12Troubles/openzonescancelarming/setting 20
4.0Disarming/unsettingthesystem 21
4.1Disarming/unsettingontheintegratedkeypad 21
4.2Disarming/unsettingonthewirelesskeypad 21
4.3Disarming/unsettingerror 21
5.0Usingwirelesskeys 22
6.0Useraccesscodes 23
6.1Accesscodes 23
6.1.1Supervisor/administrator 23
6.1.2Basic/standarduser 24
7.0Testingandresettingthesystem 25
7.1Fullsystemwalktest 25
7.2Engineer'sreset(WS912models) 26
7.3Remote(anti-code)reset(WS912models) 26
8.0Additionalfeatures 27
8.1Systemlockoutduetoinvalidattempts 27
8.2Burglaryverification 27
8.3Swingershutdown 27
8.4Firealarmverification 27
8.5User-enabledinstalleraccess 27
8.6Firmwareupdate 27
9.0Managingpartitions 28
9.1Partitions 28
9.1.1Singlepartitionoperation 28
9.1.2LoaninganLCDkeypadtoanotherpartition 28
9.2FireandCOzonetypes 29
10.0Emergencykeys 30
10.1Emergencykeysontheintegratedkeypad 30
10.2Emergencykeysonthewirelesskeypad 30
10.3Whenalarmsounds 30
- 3 -
Table of Contents
10.3.1Firealarmpulsedsiren(temporal3) 31
10.3.2Carbonmonoxide(CO)alarm 31
10.3.3Intrusion(burglary)alarm 31
11.0Viewingtroubles 33
12.0UsingZ-WaveDevices 36
12.1Z-WaveAllianceCertification 36
12.2AddingorRemovingaController 36
12.3ReplicatingaController 36
12.4ControllerLearnMode 36
12.5ChangingthePrimaryController 36
12.6AddingaDevice 37
12.6.1EditingorRemovingaDevice 37
12.7DeviceInteroperability 37
12.8Z-WaveAssociationGroups 37
12.9RespondingtotheBasicCommand 37
12.10Z-WaveReset 38
13.0Safetyinstructions 39
14.0Locatingdetectorsandescapeplan 40
14.1Smokedetectors 40
14.2Fireescapeplanning 41
14.3Carbonmonoxidedetectors 42
15.0Regulatoryagencystatements 43
16.0UKComplianceStatement 45
17.0EULA 46
18.0Referencesheets 49
18.1Systeminformation 49
18.2Servicecontactinformation 49
- 4 -
Chapter 1.0 About your security system
1.0 About your security system
Readthismanualcarefullyandhaveyourinstallerinstructyouontheoperationandfeaturesofyour
system.Allusersmustbefullyinstructedinitsuse.FillouttheSystemInformationpagewithall
ofyourzoneinformationandaccesscodes,andstorethismanualinasafeplaceforfutureref-
erence.
NOTE:Theiotegasecuritysystemincludesspecificfalsealarmreductionfeaturesandisclassified
inaccordancewithANSI/SIACP-01-2014ControlPanelStandard-FeaturesforFalseAlarm
Reduction.Consultyourinstallerforfurtherinformationregardingthefalsealarmreductionfea-
turesbuiltintoyoursystem,asthismanualdoesnotcoverallfeatures.
1.1 Fire detection
Ifyourinstallerenablesthisfeature,thissystemcanmonitorfiredetectiondevices,suchassmoke
detectors,andprovideawarningifafireconditionisdetected.Goodfiredetectiondependsonhav-
inganadequatenumberofdetectorsplacedinappropriatelocations.Thisequipmentmustbe
installedinaccordancewithNFPA72(N.F.P.A.,BatterymarchPark,QuinceyMA02269).Care-
fullyreviewtheFireEscapePlanningsectioninthismanual.
1.2 Carbon monoxide detection
Ifyourinstallerenablesthisfeature,thissystemcanmonitorcarbonmonoxidedetectorsand
provideawarningifcarbonmonoxideisdetected.RefertotheFireescapeplanningandCarbon
monoxidedetectorssectionsformoreinformation.
1.3 Testing your system
Thesystemtestactivatesa4-secondcheckofthesystemstatusLEDs,keypadLEDs,buzzer,and
siren.Itisapartition-basedtestandmustbedonewhenthesystemisdisarmed/unset.
Youcanperformasystemtestfromthewebportal.
Thefollowingeventshappenduringasystemtest:
lAllsystemstatusLEDsflashfor4seconds.
lAsystemtesttransmitstothemonitoringstation.
lThesystemchecksthebackupbatterylevel.
lThekeypadLEDsilluminatefor4seconds.
lThesystembuzzersoundsfor4seconds,orthepartitionbuzzerandsirensoundfor2
secondseachinseries.
Testyoursystemweeklytoensurethatitfunctionsasintended.Informyourmonitoringstation
whenyoubeginandendsystemtesting.
Aqualifiedservicetechnicianmusttesthouseholdfirealarmsystemsatleastevery3yearsin
accordancewithNFPA72.Itisyourresponsibilitytotestthesystemweekly,excludingsmoke
detectors.
Ifthesystemfailstofunctionproperly,callyourinstallationcompanyforservice.
- 5 -
Chapter 1.0 About your security system
1.4 Monitoring
Thissystemcantransmitalarms,troublesandemergencyinformation.Ifyouinitiateanalarmby
mistake,immediatelycallthemonitoringstationtopreventanunnecessaryresponse.
Notes:
lYourinstallermustenablethemonitoringfunctionbeforeitisfunctional.
lConsultwithyourinstallertodetermineifyoursystemisconfiguredwithacommunicator
delay.Acommunicatordelaypreventsareporttothemonitoringstationifthecontrol
panelisdisarmed/unsetwithin30-45secondsafteranintrusionalarmistriggered.Note
thatfire-typealarmsarenormallyreportedwithoutadelay.
lIfenabledandconfigured,youcancelanalarmafterthecommunicationdelaywiththe
alarmcancelwindow.RefertotheAlarmcancelwindowsectionformoreinformation.
lContactyourinstallertoverifythatyoursystemiscompatiblewiththeCentralStation
Receiverformatatyearlyintervals.
1.5 Cleaning and maintenance
Keepyouriotegainoptimalconditionbyfollowingallinstructionsincludedwithinthismanual
and/ormarkedontheproduct.Theend-userand/orinstallerareresponsiblefordisposingofused
batteriesaccordingtothewasterecoveryandrecyclingregulationsapplicabletothelocalmarket.
lCleantheunitbylightlydustingwithaslightlymoistenedcloth.
lDonotwipethefrontcoverwithalcohol.
lDonotusewateroranyotherliquid.
lDonotuseabrasives,thinners,solventsoraerosolcleaners(spraypolish)thatmayenter
throughholesandcausedamage.
lReplacethestandbybatteryevery3-5years.
Forothersystemdevicesorsensors,consultthemanufacturer’sliteraturefortestingandmain-
tenanceinstructions.
- 6 -
Chapter 2.0 General system operation
2.0 General system operation
Yoursecuritysystemincludesanintegratedalarmcontrolpanelandvarioussensorsanddetectors.
Thesystemisself-contained;thecontrolpanel,integratedkeypad,andstandbybatteryareall
housedwithintheunit.
Thesecuritysystemhasseveralzonesofareaprotection.Azoneisasensorordetectorthatcom-
municateswiththepanel.Asensorinalarmisindicatedontheintegratedkeypad,wirelesskeypad,
touchscreenkeypad,andbymessagesonthemobilephoneuserapplication.
2.1 Integrated keypad
Theiotegasystemincludesacapacitivetouchintegratedkeypadwith16keys:numbers0thru9,*,
#,Fire,Auxiliary,Panicemergencykeys,andshift(uparrow).
Duringpowerup,thenumberkeysilluminateinsequenceseveraltimes.Innormaloperation,the
keypadremainsoffwhennotinuse.Whenyouwaveyourhandincloseproximitytothekeypad,the
numberkeysilluminate.
1 2 3
4 5 6
7 8
0
*#
9
WS912-28 WS90X-XX
Notes:
lTheemergencykeysdonotilluminateunlessyoutaptheshiftkey.SeetheEmergency
Keyssectionformoreinformation.
lYoucanonlyusethekeypadforarming/setting,disarming/unsetting,andtheemergency
keys.Thesamefunctionsareavailablewhenswitchingbetweenpartitions.
2.2 Panel indicators
TheiotegasystemincludessevenLEDstatusindicators:
lFoursingle-colorLEDs
lThreemulti-colorLEDs(red,green,amber)
- 7 -
Chapter 2.0 General system operation
7654 123
89
WS912-28 WS90X-XX
Item Description
1 PowerLED
2 ReadytoArm/SetLED
3 Armed/SetLED
4 TroubleLED
5 WiFiSignalStrengthLED
6 CellularSignalStrengthLED
7 RemoteConnectionLED
8 Siren
9 Microphone
Power
Status LED Indication Description
 ON(green) ACpowerisconnectedtothesystem.
Flashing(green) SystemTest
AllstatusLEDsflashatthesametime.
OFF ThereisnoACpowertothesystem.
- 8 -
Chapter 2.0 General system operation
Ready to Arm/Set
Status LED Indication Description
ON(green) Thepartitionisreadytoarm/set.Therearenofire
orCOalarmconditions.
Flashing(green) SystemTest
AllstatusLEDsflashatthesametime.
ForceArm
Thesysteisreadytoarm/set,butForceArm-cap-
ablezonesareopen.
 WalkTest
Ready,Trouble,andArm/SetLEDsflashatthe
sametime.
 Thesystemisreadytoarm/set,butforcearmzones
areopen.
OFF Thesystemisnotreadytoarm/set.
AfireorCOalarmconditionispresent.
Armed/Set
Status LED Indication Description
ON(red) Thepartitionisarmed/set.
Flashing(red) ThepartitionisinAlarm.
NOTE:Silentalarmsorpanicsdonotflashthe
AlarmLED.
SystemTest
AllstatusLEDsflashatthesametime.
WalkTest
Ready,Trouble,andArm/SetLEDsflashatthe
sametime.
OFF Thepartitionisdisarmed/unset.
- 9 -
Chapter 2.0 General system operation
Trouble
Status LED Indication Description
ON(amber) Asystemtroubleispresent.
Flashing(amber)
[cadenceof500ms
On/500msOFF]
[*][2]TheTroublemenuisaccessed.
Flashing(amber)
[cadenceof250ms
ON/250msOFF/250ms
ON/750msOFF]
Thesystemisinthesecond-levelsubmenu.
Flashing(amber)
[cadenceof250ms
ON/250msOFF/250ms
ON/250msOFF/250ms
ON/750msOFF]
Thesystemisinthethird-levelsubmenu.
Flashing(amber) SystemTest
AllstatusLEDsflashatthesametime.
 WalkTest
Ready,Trouble,andArm/SetLEDsflashatthe
sametime.
OFF Systemtroublesarecleared.
WiFi Signal Strength
Status LED Indication Description
ON(green) Theradioisactivewithastrongsignalconnection.
ON(amber) Theradioisactivewithaweaksignalconnection.
ON(red) Thereisnosignal.
Flashing(green). TheradioisactiveinWiFiprotectedsetup(WPS)
modeforaccesspoint(AP)mode.
Flashing(amber) Z-Waveradioisactiveinlearnpairmode
Flashing(amber) SystemTest
AllstatusLEDsflashatthesametime.
OFF Theradioisinactiveornotconnectedtothenet-
work.
- 10 -
Chapter 2.0 General system operation
Cellular Signal Strength
Status LED Indication Description
ON(green) Cellularisactivewithastrongsignalconnection.
ON(amber) Cellularisactivewithaweaksignalconnection.
ON(red) Acommunicatorisinstalledbutthereisnosignalor
connection
Flashing(amber) SystemTest
AllstatusLEDsflashatthesametime.
OFF Acommunicatorisnotinstalledornotconfigured.
Remote Connection Status
Status LED Indication Description
ON(green) Thelinkisactivewithaserver.
Flashing(red) Thelinkactivatesbutfailstocommunicatewiththe
server.
Flashing(amber) SystemTest
AllstatusLEDsflashatthesametime.
OFF Thelinkisnotyetactivewithanyserver.
NOTE:IftheRemoteConnectionstatusLEDflashesred,theservermaybeundergoingmain-
tenanceorexperiencingtechnicaldifficulties.Restartingthepanelmayremedytheissue.Ifthe
problempersists,contactyourinstaller.
2.3 Integrated keypad quick reference
Usethefollowingtableforquickreferenceoftheintegratedkeypadoptions:
Action Enter
Arming/Setting and Disarming/ Unsetting
Awayarm/set [2](holdfor2seconds)+[AccessCode]ifthe[*]key
flashes.
Stayarm/set [1](holdfor2seconds)+[AccessCode]ifthe[*]key
flashes.
Disarm/Unset [AccessCode]
Abortarming/settingsequence [AccessCode]
System troubles
Silencetroubles [Anykey]or[*][2]+[Accesscode1]+[#]
Viewtroubles [*][2]+[Accesscode1]+[Troublecode]
Enable/DisableChime [*]+[4]+[AccessCode]ifthe[*]keyflashes.
1ForULlistedinstallations,youmustenteryouraccesscodetosilencetroublebeepsandviewsys-
temtroubles.
- 11 -
Chapter 2.0 General system operation
2.4 Wireless LCD keypad
Theiotegasystemsupportsthefollowingkeypadmodel:
WS9LCDWFx
x=4(433MHz),8(868MHz),9(912-919MHz)
WirelessAlphanumericLCDkeypad
2.4.1 Wireless keypad symbols
Status
LED Indication Description
Readyto
arm/set
ON(green) Thepartitionisreadytoarm/set.NofireorCO
alarmsarepresent.
Ifflashing,aForceArmtypezoneisopen.
Armed/set ON/flashing(red) Thepartitionisarmed/set.
Trouble ON(yellow) Asystemtroubleispresent.
Flashing Keypadlowbattery.
Power ON(green) ACpowerisconnectedtothekeypad.
2.4.2 Wireless keypad quick reference
Whenusingthewirelesskeypad,theiotegasystemusesshortcutkeystoaccessoptionsorfeatures.
Additionally,itusesamenu-basednavigationsystem.Usethescrollkeystonavigatethroughthelist
ofoptionscontainedwithinthecurrentmenu.
NOTE:Yourinstallermustenableandconfiguresomefeatures.
Action Press
Arming/Setting and Disarming/Unsetting
AwayArm/Set for2seconds+[AccessCode1]
StayArm/Set for2seconds+[AccessCode1]
Disarm/Unset [AccessCode]
Quickexit for2seconds
Abortarming/settingsequence [AccessCode]
Bypassing - All bypass commands begin with [*][1] + [Access Code1]
Bypassindividualzones [3-digitzone#]
Common functions
TurnchimeON/OFF for2seconds(+[AccessCode]ifconfiguredby
yourinstaller)
Changebrightness [*][6]+[Mastercode]+
Changecontrast [*][6]+[MasterCode]+
- 12 -
Chapter 2.0 General system operation
Action Press
Viewtroubles [*][2]+[Accesscode
2
]+
Viewalarms [*][3]+
Buzzervolume [*][6]+[MasterCode]+
Languageselection [*][6]+[MasterCode]+
WalkTest [*][6]+[MasterCode]+
SystemService [*][6]+[UserCode]+[5]
1Ifconfiguredbyyourinstaller
2ForULlistedinstallations,youmustenteryouraccesscodetosilencetroublebeepsandviewsys-
temtroubles.
- 13 -
Chapter 2.0 General system operation
2.5 Important notice
Asecuritysystemcannotpreventemergencies.Itisonlyintendedtoalertyouandyourmonitoring
station,ifapplicable,toanemergencysituation.Securitysystemsaregenerallyveryreliable,but
theymaynotworkunderallconditionsandtheyarenotasubstituteforprudentsecuritypracticesor
lifeandpropertyinsurance.Yoursecuritysystemmustbeinstalledandservicedbyqualifiedsecur-
ityprofessionals.Theseprofessionalscaninstructyouonthelevelofprotectionthathasbeen
providedandonsystemoperations.
2.5.1 Power save mode
WhenthepanelisinPowerSavemode,itissavingbatterylife.Theintegratedkeypadisnotturned
onuntilthereisaspecificreason,suchasahandwaveinfrontofthepanel,orthestartofanentry
delay.
Wheninitiated,thestatusindicatorsstayonfor30secondsbeforeturningoff.Inthismode,the
panelisstillfunctioning,butnothingisvisible.
NOTE:ForULlistedinstallations,theuserappandtouchscreenkeypadfunctionsarenotavailable
inthismode;therefore,youmustusetheintegratedkeypadorthewirelesskeypadtoarm/setordis-
arm/unsetthesystem.
2.6 System models
ThereferencetoWS900inthismanualcoversthefollowingmodels:
WS900-29* Alarmsystemwithtwo-wayaudiosupport,operatingin912-919
MHzband
WS900-19* Alarmsystemwithtwo-wayaudiosupport,operatingin912-919
MHzband
3G7090* 3GCellularAlarmCommunicator
LT7090* VerizonLTEOnlyCellularCommunicator
(*)ThesedevicesareUL/ULClisted.
NOTE:Two-wayaudiosupportwasnotevaluatedbyUL/ULC.
WS912-28 Alarmsystemoperatingin868MHzband
WS901-24EU Alarmsystemoperatingin433MHzband
WS901-14 Alarmsystemoperatingin433MHzband
3G7090-EU 3GCellularAlarmCommunicator
2.7 Language selection
Theiotegasupportsthefollowinglanguages,althoughnotallmaybeavailableonyoursystem:
lEnglish
lFrench
lSpanish
lPortuguese
- 14 -
Chapter 2.0 General system operation
lGerman
lDutch
lSwedish
lFinnish
lNorwegian
lDanish
lPolish
lItalian
lGreek
Availablelanguagescanbeselectedusingthetouchscreenkeypadorthewirelesskeypad.
- 15 -
Chapter 3.0 Arming/Setting the system
3.0 Arming/Setting the system
Youcanarm/setthesystemusingthefollowingoptions:
lIntegratedkeypad
lWirelesskeypad
lTouchscreenkeypad
lUserapp(OperationwiththeuserappwasnotevaluatedbyUL/ULC.)
lWirelesskey(RefertotheUsingwirelesskeyssectionforalistofUL/ULClistedcom-
patiblewirelesskeys.)
3.1 Stay arming/setting
Stayarming/settingprotectsonlytheperimeterofthepremisespermittingmovementinside.
NOTE:Toarm/setthesysteminStaymode,yourinstallermustenrollandconfigureatleastone
zoneasanInteriorStay/AwayoraDelayStay/Awaytypeofzone.
3.1.1 Stay arming/setting on the integrated keypad
1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindic-
atorison.
2. Enteryouraccesscodeanddonotleavethepremises.Thesystemautomaticallyignores
bypassedzonesandinitiatestheexitdelaycountdown.
Tocancelthearming/settingsequence,enteryouraccesscode.
Whenexitdelayisactive,theArmed/SetandReadyindicatorsturnonandthekeypadbeepsonce
persecond.Whentheexitdelayexpires,thesystemisarmed/setandtheReadyindicatorturnsoff
andtheArmed/Setindicatorstayson.
ForEN,whenexitdelayisactive,theReadyindicatorstaysonandthekeypadbeepsonceper
second.Whentheexitdelayexpires,thesystemisarmed/set,theReadyindicatorturnsoff,andthe
Armed/setindicatorturnson(ENonly).
NOTE:ForSIACP-01listedpanels,theStayarming/settingexitdelaywillbetwiceaslongasthe
Awayarming/settingexitdelay.
IfyoursystemisinstalledinaccordancewithSIACP-01StandardforFalseAlarmReduction,the
securitysystemarms/setsintheStaymodeiftheexitdelaytimeexpiresandtherewasnoexit.
Ifyouarm/setthesystemremotelywithoutexitdelay,thesecuritysystemarms/setsinAwaymode
only.
3.1.2 Stay arming/setting on the wireless keypad
Staymodepartiallyactivatesyouralarmsystembyarming/settingallperimetersensorsand
bypassingallinteriorsensors.
Toarm/setthesysteminStaymode,completethefollowingsteps:
1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindic-
atorison.
2. Enteryouraccesscode.
OR
- 16 -
Chapter 3.0 Arming/Setting the system
PressandholdtheStayfunctionkeyfor2secondsandenteryouraccesscode,ifrequired.
Ifzoneshavebeenbypassed,awarningappears.
Aftersuccessfullyinitiatingthearming/settingsequence,thefollowingeventsoccur:
lArmed/Setindicatorturnson.
lReadyindicatorremainson.
lExitDelaytimerbeginscountingdown.
Whentheexitdelaytimerexpires,arming/settingthesystem,thefollowingeventsoccur:
lReadyindicatorturnsoff.
lArmed/Setindicatorremainson.
lBypassorsystemindicatoractivates.
ForEN,Aftersuccessfullyinitiatingthearming/settingsequence,theReadyindicatorremainson
andtheexitdelaytimerbeginscountingdown.
Whentheexitdelaytimerexpires,arming/settingthesystem,thefollowingeventsoccur:
lReadyindicatorturnsoff.
lArmed/Setindicatorturnson.
lBypassorsystemindicatoractivates.
Tocancelthearming/settingsequence,enteryouraccesscode.
3.2 Silent exit delay
Ifthesystemisarmed/setinStaymodeorusingtheNo-entryarming/settingmethod,thekeypad
buzzerissilencedandtheexittimeisdoubledforthatexitperiodonly.(SIACP-01only).
3.3 No-entry arming/setting
No-entryarming/settingsetsthesysteminStayorAwaymodeaftertheexitdelayexpiresand
removestheentrydelay.
Notes:
lAllzonesprogrammedasDelayfunctionthesamewayasinstantzones.
lThisfeatureisonlyavailableonthetouchscreenkeypadanduserapp.
3.4 Away arming/setting
AwayModearms/setstheentiresystem,includingtheperimeterandinteriordevices.
3.4.1 Away arming/setting on the integrated keypad
Toarm/setthesysteminAwaymodeontheintegratedkeypad,completethefollowingsteps:
1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindic-
atorison.
2. Enteryouraccesscode.Exitdelaybegins.Exitthepremisesthroughadoorprogrammed
asentry/exittype.
Tocancelthearming/settingsequence,enteryouraccesscode.
- 17 -
Chapter 3.0 Arming/Setting the system
ForNA,whenexitdelayisactive,theReadyindicatorremainson,theArmed/Setindicatorturns
onandthekeypadbeepsoncepersecond.ForEN,whenexitdelayisactive,theReadyindicator
remainsonandthekeypadbeepsoncepersecond.Dependingonyoursystemconfiguration,you
have____secondstoexitthepremises.Yourinstallercanprogramthistime.
Thekeypadbuzzeremitsarapidpulsatingrateduringthelast10secondsoftheexitdelaytoindic-
atethatthetimeisexpiring.
ForNA,whentheexitdelayexpires,thesystemisarmed/set,theReadyindicatorturnsoffandthe
Armed/setindicatorstayson.
NOTE:InAwayMode,manuallybypassedzonesareloggedandcommunicatedtothemonitoring
station.
IfyoursystemisinstalledinaccordancewithSIACP-01StandardforFalseAlarmReduction,the
followingconditionapplies:Violationandrestoral,followedbyasecondviolationoftheentry/exit
zonebeforetheendoftheexitdelay,restartstheexitdelay.
3.4.2 Away arming/setting on the wireless keypad
Toarm/setthesysteminAwaymode,completethefollowingsteps:
1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindic-
atorison.
2. Enteryouraccesscode.
OR
PressandholdtheAwayModefunctionkeyfor2secondsandenteryouraccesscode,if
required.
Ifzoneshavebeenbypassed,awarningappears
Tocancelthearming/settingsequence,enteryouraccesscode.
NOTE:Yourinstallerconfigurestheexitdelaytime.
3.5 Quick arming/set
Ifenabled,youcanarm/setthesysteminStayorAwaymodewithoutenteringanaccesscodewith
theuserapporthefunctionkeyonthewirelesskeypad.
Ifdisabled,youmustenteryouraccesscodeforallmethodsofarming/setting.
NOTE:Thisfeatureisenabledbydefault.Contactyourinstallertodisablethisfeature.
3.6 Quick exit
Ifenabled,youcanusetheQuickExitfunctiontoavoiddisarming/unsettingandrearming/resetting
thesystemtoexitthepremises.Whenthesystemisarmed/set,thisfunctionallows2minutesto
exit.Whenthedoorisclosedafterexiting,theremainingexittimeiscancelled.
Notes:
lYourinstallermustenableandconfigurethisfeature.
lThisfeatureisnotavailableontheintegratedkeypad.
- 18 -
Chapter 3.0 Arming/Setting the system
3.6.1 Quick exit on the wireless keypad
TousetheQuickExitfunctiononthewirelesskeypad,completethefollowingsteps:
1. Whensystemisarmed/setandtheArmed/Setindicatorison,pressandholdtheQuick
Exitkeyfor2seconds..
2. Exitthepremisesbeforetheexitdelaytimerexpires.Afterexiting,thedelaytimeriscan-
celed.
3.7 Arming/Setting errors and exit faults
Yoursecuritysystemaudiblynotifiesyouofanyerrorswhenyouareattemptingtoarm/setthesys-
temorexitthepremises.
3.7.1 Arming/Setting error
Anerrortone(longbeep)soundsifthesystemisunabletoarm/set.Arming/settingerrorsoccur
underthefollowingconditions:
lTheaccesscodeisincorrect.
lThesystemisnotready,i.e.sensorsareopen.
lAtroubleconditionispresent.
lThesystemrequiresareset.
Ifyouenteravalidaccesscodeandthesystemisstillunabletoarm/set,amessageappearsonthe
keypad.Thefollowingtableliststhepossibleerrorsandactionstoclearthem:
Message Action
Sensor(s)Open(*)toBypass Press[*]toviewandbypass1theopensensors.
SystemTrouble(*)toView Press[*]toviewtroubles,thenpress[99]orscrolltotheTrouble
Acknowledgmentpromptandpress[*]tooverridethetroublecon-
dition.
ResetRequired Contactyourinstallertocheckandresetthesystem.Refertothe
Engineer'sresetsectionformoreinformation.
1Ifconfiguredbyyourinstaller.
Ensureallsensorsaresecureandthesystemisreadytoarm,thentryagain
3.8 Audible exit fault
Toreducefalsealarms,theaudibleexitfaultnotifiesyouofanimproperexitwhenarmingthesys-
tem.Iftheentry/exitdoorisnotsecurelyclosedduringtheprogrammedexitdelay,thesystem
soundsthealarmtoindicateanimproperexit.
Tocorrectanexitfault,completethefollowingsteps:
1. Re-enterthepremises.
2. Enteryouraccesscodetodisarm/unsetthesystembeforetheentrydelaytimerexpires.
- 19 -
Chapter 3.0 Arming/Setting the system
3. Ensureallsensorsaresecureandthesystemisreadytoarm/set.
4. RepeattheAwayarming/settingprocedure.
3.9 Alarm cancel window
Thereisaperiodoftimeinwhichyoucancancelthealarmtransmission.Whentheprogrammed
alarmtransmissiondelayexpires,cancelinganalarmsendsamessagetothemonitoringstation.
Whenthecancellationmessageissuccessfullytransmitted,thesystembeepssixtimes.
NOTE:
lYourinstallermustenableandconfigurethisfeature.
lForCP-01systems,alarmtransmissiondelaymustnotexceed45seconds.
3.10 Bypass zones
Usethezonebypassingfeaturewhenyouneedaccesstoaprotectedareawhilethesystemis
armed/set,orwhenazoneistemporarilyoutofservice,butyouneedtoarm/setthesystem.
Bypassedzonesarenotabletosoundanalarm.Asaresult,bypassingzonesreducesthelevelof
security.Ifyouarebypassingazonebecauseitisnotworking,callaservicetechnicianimme-
diatelytoresolvetheproblemandrestoreyoursystemtoproperworkingorder.
Ensurethatnozonesareunintentionallybypassedwhenarming/settingyoursystem.Zonescannot
bebypassedoncethesystemisarmed/set.Bypassedzones,exceptfor24-hourzones,areauto-
maticallyunbypassedeachtimethesystemisdisarmed/unsetandmustbebypassedagainbeforethe
nextarmin/setting,ifneeded.
Notes:
l24-hourzonescanonlybeunbypassedmanually.
lForULlistedinstallations,zonescanonlybebypassedmanually.
3.11 Force arming/setting
OpenzoneswiththeForceArmattributeenabled,suchasinteriorzones,donotneedtobe
bypassedtoarm/setthesystem.Notethatyoursystemmaybeconfiguredtorequireallopenzones
tobebypassed,andmayalsorequireanaccesscodetodoso.Checkwithyourinstaller.
IfForceArm-typezonesaresecuredwhilethesystemisarmed/set,theyfunctionasanynormal
zone.Thatis,iftheyareopenedwhilethesystemisarmed/set,analarmisgenerated.
TheReadyLEDflasheswhilethesystemisdisarmed/unsettoindicatethepresenceofopen,Force
Arm-typezones.
3.12 Troubles/open zones cancel arming/setting
IfTroubles/OpenZonesCancelArming/settingisdisabled,arming/settingcanproceedwhile
troublesarepresentandzonesareopen.However,thesystemgoesintoalarm/entrydelay(depend-
ingonthetypeofthezone)afterbeingfullyarmed/setiftheopenzonesarenotbypassed.
- 20 -
/